The ABB ACS355 machinery drive is designed for the OEM machine‑building sector and engineered to be the fastest drive in terms of installation and set‑up. The ACS355 is user‑friendly, yet provide high application flexibility. Typical applications include food & beverage, material handling, printing, rubber & plastics and woodworking applications.
ACS 355 Features:
Sensorless Vector Control
0.5 to 5hp 240V, 1 & 3-Phase
0.5 to 15hp 480V, 3-Phase
IP20 Open Vent Protection
FlashDrop - Fast parameter set-up
Sequence programming
Optimized interfaces for users and machines
Unified height and depth
Coated boards as standard
Built-in brake chopper as standard
Built‑in EMC filter for 2nd environment
UL, cUL and CE approved
For more ABB AC Drives available at galco.com visit: www.galco.com/s...
To see all ABB Drives go to: www.galco.com/g...
And to vew the full line of ABB products available at galco.com visit: www.galco.com/f...
Sign up for Galco’s newsletter that features our newest products, our can't-miss deals, our best videos, and total access to Galco’s electronics expertise: www.galco.com/e...
Connect with us!
plus.google.co...
/ galcoindustrial
/ galcoindustrial
/ galcoindustrial
/ galco-industrial-elect...
Don't forget to like and comment on this video, and subscribe to our channel!
Galco is a Factory Authorized Stocking Distributor for Over 150 Brands of Industrial Electrical & Electronic Automation, Controls and Component Products; On-Site and Send-In Repair Services for Industrial Control & Automation Products for Over 2,000 Brands; Engineered Systems Integration, Retrofits & Upgrades for Variable Speed Drives, CNC, PLC Systems, Dynamometers & Test Stand Applications. Visit us online at www.galco.com or call us at 800-337-1720.
www.galco.com/s...
With respect to the usage, installation or assembly of any products described in this video, Galco Industrial Electronics, Inc., a Michigan corporation, encourages you to follow the requirements and/or guidelines of: i) the Occupational Safety and Health Act of 1970, Public Law 91-596, as amended, and all laws, rules and regulations implemented in relation thereto; ii) the National Electric Code®; and iii) NFPA 70E®. Any installation, assembly or work described in this video should be performed by a qualified licensed electrician.
GTV, Galco, galco.com, Galco Industrial Electronics, and Galco Industrial Electronics, Inc. are registered and/or pending registered trademarks under the U.S. Patent and Trademark Office, assumed names, registered domain names, and/or trade names of Galco Industrial Electronics, Inc., a Michigan corporation.

Опубликовано:

 

22 окт 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии    
@leonardourlian2371
@leonardourlian2371 3 года назад
Boa noite amigo eu tenho um ACS 355 220 v Instalado em um torno gostaria de saber se tem algum parâmetro que eu coloca pra aumentar o torque em baixas rotações
@leonardourlian2371
@leonardourlian2371 3 года назад
Good night friend I have an ACS 355 220 v Installed in a lathe I would like to know if there is any parameter that I use to increase the torque at low speeds.
@AnkitPatel-mn1pv
@AnkitPatel-mn1pv 2 года назад
How can I set torq parameters in the drive?
@santanainmexico
@santanainmexico 7 лет назад
is possible to change the max/min input values for the analog input?
@tamilvanan1401
@tamilvanan1401 5 лет назад
Rated frequency was 60hz at motor nameplate and same is set in the VFD but motor running condition frequency not increased more than 53hz ,can u tell what the problem
@GalcoIndustrial
@GalcoIndustrial 5 лет назад
Most likely you have 1 of 2 potential problems. 1) Reference scaling; what are the settings in parameters 1103 to 1108. 2) The motor is at maximum load and the drive is in current limit.
@kalpeshhingu1195
@kalpeshhingu1195 4 года назад
Dear sir. ABB ACS 800 Control display not start up. CDP 312 Penal V5. 30 showing
@ameeralthalam1306
@ameeralthalam1306 3 года назад
How i can buy one ACS150-01E-09A8-2 2.2kw 3ph Input 220v Output 3 phase Me from iraq .. i need one .. How much with arrive to iraq ?
@rami1612
@rami1612 9 лет назад
In the settings here in video the drive follows the value u choose for "ref", will it work as variable frequency incase you use solar knowing that par 1103 is set to solar? thank you
@GalcoIndustrial
@GalcoIndustrial 9 лет назад
Rami H The drive is still a variable frequency control, but when you set parameter 1103 to solar, the drive automatically adjusts the output frequency based on how much power the PV cells are producing. You cannot manually set the output frequency in this mode.
@rami1612
@rami1612 9 лет назад
so wat i have to do with the "ref"? parameter 1103 already set to solar. and parameter 9904 is set on scalar frequency. could the problem be from the mitsubishi magnetic switch installed after the drive?
@nasardish4128
@nasardish4128 5 лет назад
How to connect potentiolmeter &switch please vidio or diagram
@أذكرالله-ف3ض
@أذكرالله-ف3ض 3 года назад
How to connect the Abb ACS355 device to become automatic
@epitome6991
@epitome6991 5 лет назад
My abb acs355 showing fault f0004 plz help what should i do
@genbawindy
@genbawindy 9 лет назад
I am setting a new parameter but when I press enter again it does not turn the paramater number back. How should I change the settings? is there a block setting to not change paramaters?
@GalcoIndustrial
@GalcoIndustrial 9 лет назад
+Cengiz Oğuzer When you want to change a parameter using the standard keypad, once you select the parameter, you need to hold the ENTER button in for a few seconds until the word SET appears at the bottom of the display, next to the word PAR. Once you see this you can change the parameter to what you want, then push ENTER again to save it. You will need to do this each time you want to change a parameter. There is also a PARAMETER LOCK, parameter 1602, which prevents parameters frombeing changed from the keypad, this should be set to 1 which means unlocked. If it set to a 0, then it is locked and you need to go to parameter 1603 and enter 358 to unlock.
@genbawindy
@genbawindy 9 лет назад
+GalcoTV Thank you very much. It was exactly how you described, it was locked. Now can change all.
@muaathe78
@muaathe78 8 лет назад
Hi, may I ask what is the difference between ACS335 AND ACS150
@GalcoIndustrial
@GalcoIndustrial 8 лет назад
+Muaathe Aziz the difference is power. The ACS355 ◾0.37 to 22 kW/0.5 to 30 hp ◾Optimized design for cabinet installations saves space and installation time ◾Wide range of fieldbus adapters available offer flexible connectivity ◾Vector control capable of running both asynchronous motors and permanent magnet motors ◾Simple and visual sequence programming to make independent and repeatable operation sequences ◾Pre-defined application macros for quick basic setup ◾Unified height and depth of the IP20 product family simplifies wiring in cabinet installations The ACS150 ◾Power range 0.37 to 4 kW/0.5 to 5 Hp ◾IP20 enclosure ◾Scalar control ◾Integrated user interface and potentiometer ◾Built-in brake chopper ◾Built-in EMC filter for 2nd environment
@brahimbrahim-ep7gd
@brahimbrahim-ep7gd 3 года назад
I want to know this code F 0046
@KAJEMIBNEARIF
@KAJEMIBNEARIF 3 года назад
Reverse forward setting plz
@Samsung-no8ff
@Samsung-no8ff Год назад
What happens if F0028 fault appears on this screen
@dilipsrinivas7149
@dilipsrinivas7149 6 лет назад
Is there a way to run a 1 phase motor with ACS 355 drive ?
@GalcoIndustrial
@GalcoIndustrial 6 лет назад
Generally speaking no. However we have run a single phase fractional HP motor on a VFD and it responded fairly well. You should also know that it was just a fan motor with no fan blade attached. Single phase motors are not intended to be run on a VFD. A Reduced Voltage Starter would be a more economical choice for a single phase application.
@smallgoon
@smallgoon 7 лет назад
How do we set the drive up for analog control from an analog input?
@GalcoIndustrial
@GalcoIndustrial 7 лет назад
Simply wire up the speed pot to terminals 2, 3 and 4 on connector X1A. The drive is defaulted to this input. However you do have to make sure the drive is in remote mode. Look in the upper left corner of display on keypad to see if in remote, if not push the LOC/REM button to toggles modes.
@arunbhatt5612
@arunbhatt5612 7 лет назад
hii i want to set speed when i set it after 2 minuts stop abb 355...motor load 7.5
@norfazlimokri3598
@norfazlimokri3598 6 лет назад
Why the voltage output just only reach 160v to 170v, how to set up the voltage back to 240v? The input voltage is 240v....anyone please advice...
@GalcoIndustrial
@GalcoIndustrial 6 лет назад
Are you running at 60Hz? What are you measuring the voltage with?
@norfazlimokri3598
@norfazlimokri3598 6 лет назад
Measuring by multimeter...the out put cameout with 150V
@Shorts.shorts.326
@Shorts.shorts.326 5 лет назад
@@norfazlimokri3598 you will not get a correct voltage reading using a multimeter as it varies the frequency and torque in various startup and running stage
@miukumara9918
@miukumara9918 6 лет назад
my abb acs 550 show in error not responding device,please guide me to correct it
@GalcoIndustrial
@GalcoIndustrial 6 лет назад
OK well first of all what fault is it showing on display, or is there no power?
@miukumara9918
@miukumara9918 6 лет назад
GalcoTV
@miukumara9918
@miukumara9918 6 лет назад
before its shows fault code 29
@miukumara9918
@miukumara9918 6 лет назад
now its shows "device not responding "
@rudyiskandarabubakar9362
@rudyiskandarabubakar9362 9 лет назад
i'm getting fault F0035.What is wrong with it?
@GalcoIndustrial
@GalcoIndustrial 9 лет назад
Rudy Iskandar Fault 0035 is OUTPUT WIRING, which according to the manual, the most common cause is the input power wires are connected the drive output. The input power wire should be connected to terminalsU1, V1 & W1 and the motor wires should be connected to terminals U2, V2 & W2. The other possibility per the manual is “Fault can be declared if the input poweris delta grounded system and motor cable capacitance is large.”
@mirarsheed2275
@mirarsheed2275 5 лет назад
My fault is f0001. Please help
@MrSweetlove12
@MrSweetlove12 6 лет назад
How to tke 24V from ACH550 drive?
@GalcoIndustrial
@GalcoIndustrial 6 лет назад
Terminal 10 of the X1 connectors is +24volt output, terminal 11 is the 24volt common. If 11 and 12 jump together, then connect each digital input to the + output to activate each input.
@brahimbrahim-ep7gd
@brahimbrahim-ep7gd 3 года назад
I want to know this code F 0046
@fairose1052
@fairose1052 5 лет назад
I get alarm on display a20 10 what ll do
@GalcoIndustrial
@GalcoIndustrial 5 лет назад
Here's what I found for your scenario, Motor temperature is too high (or appears to be too high) due to excessive load, insufficient motor power, inadequate cooling or incorrect start-up data.
@fairose1052
@fairose1052 5 лет назад
@@GalcoIndustrial thanks for ur reply. How to reset the drive.
@GalcoIndustrial
@GalcoIndustrial 5 лет назад
@@fairose1052 your welcome. Please don't hesitate to ask any additional questions, and let us know how it went.
@fairose1052
@fairose1052 5 лет назад
@@GalcoIndustrial how to remove this alarm A 2010
@arunbhatt5612
@arunbhatt5612 7 лет назад
abb acs 355 or 350 difference
@baburaoalagundi2812
@baburaoalagundi2812 5 лет назад
How sett RPM from Hz
@GalcoIndustrial
@GalcoIndustrial 5 лет назад
It depends on which control mode you have selected in parameter 9904, SCALAR FREQ displays Hz, VECTOR SPEED or VECTOR TORQUE will read out in RPM.
@narayanadhikari3230
@narayanadhikari3230 9 лет назад
Acs 355 drive show on monitar fault f1009
@GalcoIndustrial
@GalcoIndustrial 9 лет назад
Narayan Adhikari If you're getting a fault 1009, it could be that the settings for parameter 9907 (Motor Nominal Frequency) or 9908 (Motor Nominal Speed) are incorrect. Recheck your nameplate to see if they match.
@mosesmfalanyombo7721
@mosesmfalanyombo7721 8 лет назад
ACS550 DRIVE show a fault F0021,what is a solution?
@GalcoIndustrial
@GalcoIndustrial 8 лет назад
Moses Mfalanyombo The manual says “Internal fault. Current measurement is out of range.”, this says that the drive is defective, you can try a couple of tests to confirm this. If you can run the drive and measure the current going to the motor and compare it to parameter number 0104, which is current. If there is a big difference between them, you have a problem with the drive. If they are the same, compare that value to the full load amps of the motor, if it is higher, you may have a motor on load issue. If you can’t run the drive, disconnect the motor and try to run it again. If it still faults, you have a problem with the drive. If it runs with the motor disconnected, look at parameter number 0104, it should be zero. If the value is not close to zero, you have a drive problem. If it is close to zero, you may have a motor or load issue. Try reconnecting the motor without the load connected to it and see if the drive faults. If it does, check your motor, if it doesn’t, check your load.
@Shorts.shorts.326
@Shorts.shorts.326 5 лет назад
@@GalcoIndustrial either motor coil burned or Inverter failed
@govindrajuyamparala787
@govindrajuyamparala787 6 лет назад
How to reset
@GalcoIndustrial
@GalcoIndustrial 6 лет назад
Use the stop button or cycle power to it.
@MohdNazim-xe3xv
@MohdNazim-xe3xv 5 лет назад
@@GalcoIndustrial I need your WhatsApp no. I asked about abb drive That's my WhatsApp number. +919458547118
@ปราการสารีศรี
ขอภาษาไทยใด้มั้ยครับ
@ajazhaider5866
@ajazhaider5866 7 лет назад
my drive show error 2010
@GalcoIndustrial
@GalcoIndustrial 7 лет назад
This is a motor overtemp fault. Check the load on the motor, check the fan is not broken or block air flow. Running at low speeds for long periods of time can overheat the motor. If this doesn't help give us a call at 800-337-1720 and ask for an ABB product manager to assist you.
@Shorts.shorts.326
@Shorts.shorts.326 5 лет назад
@@GalcoIndustrial also may be the the invertor temperature sensor damage
@v.gowthamgs7571
@v.gowthamgs7571 4 года назад
Language problem ... explain tamil
@ajazhaider5866
@ajazhaider5866 7 лет назад
but I install a new
@GalcoIndustrial
@GalcoIndustrial 7 лет назад
Then double check the group 99 parameters for correct motor data entered if you haven't already. This may not be a drive issue, the motor is getting to hot not the drive. Are you running at low speeds?
@majiiidsaber7804
@majiiidsaber7804 2 года назад
درد و بلات بخوره تو سر جو بایدن .
@ممحمدراضىنظرةمداللطاقهالشمسيه
هل يوجد برمجه بالعربيه
@ameeralthalam1306
@ameeralthalam1306 3 года назад
اتعبني البحث عن برمجه بالعربي ... لكانت المهمه اسهل المشكله ان الكتلوك غير معرب ايضا ...وحتما الوقوع في اخطاء
Далее
The Tri Folding Phone Impressions!
11:18
Просмотров 3,2 млн
ABB ACS550 AC Drive Basic Startup
6:46
Просмотров 650 тыс.
How to troubleshoot and diagnose a non-working VFD
8:49
How To: Troubleshoot VFDs
11:30
Просмотров 36 тыс.
How to commission the ACS355 machinery drive
5:09
Просмотров 37 тыс.