Working on same purifier SA835 Alfa laval 10400 rpm but the problem was facing after certain time of running PT4 pressure is dropping and feed pressure increases to 3.3 m3/hrs
Could you check if there's a valve with an allen key that you could use to adjust the PT4? Usually if this valve is not properly calibrated some problems with PT4 happens.
Tama ,manual opening and closing ng water flow yan. Usually kapag mag trouble shoot ginagalaw natin yan (Open/Close) to check kung may flow ang operating at sealing water.
@@thishandleisntavailble444 high oil pressure baka blocked ang fuel line or may close na valve. Kapag heavy vibration yes kailangan i apply ang brake. Pero pagkatapos kailangan check baka hndi na okay ang alignment ng bearing kaya malakas na mag vibrate or baka imbalance na dahil madumi na ang disc stack.
If you stop the unit from the emervency stop button, how can you reset it. In our system it does not reset if you just unlatch the emcy stop button. Can you check yours?
Correct. We need correct separation temperature only that for this purifier tutorial , we were having MGO since we are in ECA, hence no heating was required. Will try to make new one on HFO. Thanks!
Setting in terms of temperature? Makikita sa bunker analysis. Dun kasi naka depende ang treatment ng oil. Check your bunker lab data and dun ka mag base sa requirements. Thanks for dropping by.
Hey' Find the valve that controls the back pressure. It is the one with the Allen key adjusting knob. Forgot the specific valve number but that's how we adjust the feed rate. You can also try to adjust the manual inlet valve to control the flow.