How To Test a VFD (variable frequency drive) 

Engineering Support 4 Food and Drink Manufacturers
Подписаться 1,5 тыс.
Просмотров 63 тыс.
50% 1

How do you test a VFD to prove it's any good or needs repair? This video will show you some simple tests and give some theory on the internals of the Variable Frequency Drive.
Variable speed drives are widely used to control electrical motors, they provide more accurate speed control and increased protection to the motor.
These drives can fail and this video will show you some tips for testing a VFD drive.
Let me know in the comments what other content you want to see.

Наука

Опубликовано:

 

6 авг 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 38   
@pjofurey6239
@pjofurey6239 Год назад
Nice.simple.clear .suspect a grumpy VFD on my lovely old skool mill, this film gives me the enthusiasm to investigate .subbed.
@bryanvigil6554
@bryanvigil6554 4 месяца назад
Very useful I actually came across one today and I needed this video
@engineeringsupport247
@engineeringsupport247 3 месяца назад
This is why I make them, glad you found it useful
@donnacorbett5165
@donnacorbett5165 2 года назад
excellent video learned a lot, nicely explained
@engineeringsupport247
@engineeringsupport247 Год назад
Thanks
@anirutkhaopluem6485
@anirutkhaopluem6485 2 года назад
Good explanation, THANK YOU!
@engineeringsupport247
@engineeringsupport247 2 года назад
Thanks 👍
@carlhutchison4118
@carlhutchison4118 6 месяцев назад
Very good have 27kv pump motors and 12 wire soft start motors at work good testing thanks
@austrianpainterhidingfromt5920
Good video with a straight forward and simple explanation of theory. I work in hvac and run into these quite a lot. Just subbed.
@engineeringsupport247
@engineeringsupport247 Год назад
Thanks
@jonerasmus9399
@jonerasmus9399 Год назад
Thank you for the video . The only thing I wish was you showing on the schematic which points your were testing between a little more clearer. Otherwise I quite enjoyed your vid . Thank you for your effort to teach us things the technicons failed to do
@engineeringsupport247
@engineeringsupport247 Год назад
Thanks for the feedback, I will try to do an update on the schematic
@jonerasmus9399
@jonerasmus9399 Год назад
@@engineeringsupport247 I'd very much like that . Thank you so much ...legend
@frobertopereira
@frobertopereira Год назад
Very nice. Helped a lot. Thank you. In my VFD 9600D-1T-00220M case, the brake resistor is internal. It has two output connectors to attach an external resistor but was internally not wired, so I had to open it to access P+ and P-.
@engineeringsupport247
@engineeringsupport247 Год назад
Sounds like a nightmare, but good work for figuring it out 👍
@igieborjolly1106
@igieborjolly1106 Год назад
Nice one, I have an issue with a seimen 120 ac drive. When you put power on the 3phase incoming I don't get a DC voltage on the capacitor side.
@larrybassik2768
@larrybassik2768 2 года назад
Great Content Learned Alot
@engineeringsupport247
@engineeringsupport247 2 года назад
Thanks - I really should do more content!
@svsoleil3255
@svsoleil3255 2 месяца назад
"They explode a bit and let the smoke out.." LMAO...
@jaykesapalaran5434
@jaykesapalaran5434 Год назад
Wow great tutorial.. please make more educational video.. you deserve to be subscribe.
@engineeringsupport247
@engineeringsupport247 Год назад
Thanks, what other topics would you like to hear about?
@NONEYAZ
@NONEYAZ Год назад
Good Teaching! Just A Tip For The Young Bucks & Doe's Out There! When Your In Industrial Manufacturing As A Technician Responsible For Troubleshooting, Fixing And Preventive Maintenance Of Equipment. Your Ultimately Responsible For Optimum Up Time, Output And Quality Of Equipment And The Products Being Produced & Processed! Therefore, There's Not Much Time In Production For Testing & Troubleshooting! Remove Smoking, Burnt Defective Modules, Assemblies, Devices, Etc! Swapping Them With New Ones Whenever Possible! Once Verified The Equipment Was Up And Running In Optimum Condition By Troubleshooting With New Modules Along With All Other Equipment Of Responsibility Being Up And Running! Take The Suspect Modules, Etc, In Engineering/Technicians Lab To Repair By Opening And Removing, Replacing Said Burnt Defective Components! Then, Test As Needed Or You Could Send Them Out For Repair Or Replacement To Vendor(s) Depending On Free Time Of Up/Down Time Of High Volume Production Equipment! Most Of The Time As A Technician You Have To Learn To Put Out The Fire(s) And Read Every Vendor(s) Machine And Equipment User/Troubleshooting And Repair Manual You Can! The Internet Wont Always Be Here Or Up & Available Due To Censorship Or Who Knows What!?! Thus, There's Always Time To Learn To Wash, Polish And Wax The Fire Truck After It's Repaired, Maintained & In Working Order If You Spend Time Wisely Reading The User & Repair Manuals! 😎
@bikefarmtaiwan1800
@bikefarmtaiwan1800 Год назад
Nice video - maybe you will be interested to know that the wiring in the bridge rectifier is what "magically" turns AC into the full wave rectified DC . The capacitor takes this wavy DC and then smooths that into the power that is used on the DC bus . The bridge rectifier wiring does some crafty re-routing to achieve this which had me confused for a while .... how does negative become positive ?? Regardless of the side that the AC wave is on compared to the zero volts line it is all voltage potential so half of the bridge flips the lower ( negative part of the AC wave ) up to the top to give you full rectification - no gaps ! Hope that helps
@engineeringsupport247
@engineeringsupport247 Год назад
Thanks, that takes me back to college. It also stumped me for ages how the rectifier works.
@tupachillin
@tupachillin 9 месяцев назад
So when your checking reverse bias, you want an infinite or OL reading?
@engineeringsupport247
@engineeringsupport247 9 месяцев назад
I believe this depends on the meter, my Fluke multi meter will show OL and my Megger Low ohm meter will show infinity.
@HCheatNcool
@HCheatNcool Год назад
When you call those a bridge rectifier, is that the same thing as SCR silicone current rectifier
@engineeringsupport247
@engineeringsupport247 9 месяцев назад
I don't believe so, a bridge rectifier turns AC to DC, an SCR in my understanding is a Thyristor with a Gate that will only conduct when the right current is applied to the Gate.
@blackbearbowie8162
@blackbearbowie8162 5 месяцев назад
can you show how find out the kw of a vfd that has no data plate ?
@engineeringsupport247
@engineeringsupport247 3 месяца назад
I don’t know how to do that sorry
@kevinmithnick9993
@kevinmithnick9993 Месяц назад
One possible solution is when configuring parameters, particularly current limits, you go for the upper limit. That value can give you an idea of that vsd capabilities Greetings from Colombia
@youngestincharge1998
@youngestincharge1998 Месяц назад
@@engineeringsupport247 can you post more videos very helpful
@electrical8308
@electrical8308 Год назад
Panel got 'cleaned' 😂. I know exactly what you mean! 'hygiened' by any chance 😂
@engineeringsupport247
@engineeringsupport247 Год назад
Yeah lol “what would happen if I put a high pressure hose on that”
@ChandrashekarCN
@ChandrashekarCN 2 месяца назад
💖💖💖💖
@mikeadler434
@mikeadler434 7 месяцев назад
👍👍
Далее
На фейсконтроле 💂
09:41
Просмотров 875 тыс.
Советы на всё лето 4 @postworkllc
00:23
How to bypass the VFD?
10:52
Просмотров 25 тыс.
One Simple way to check if an AC drive is good
24:13
Просмотров 34 тыс.
How To Check Trouble Shooting:Variable Frequency Drive
3:17
How to troubleshoot and diagnose a non-working VFD
8:49
How To Test an IGBT
13:01
Просмотров 352 тыс.
How To: Troubleshoot VFDs
11:30
Просмотров 30 тыс.
What Types of Motors Can Be Used with VFDs?
6:58
Просмотров 68 тыс.
КАКОЙ SAMSUNG КУПИТЬ В 2024 ГОДУ
14:59
#samsung #retrophone #nostalgia #x100
0:14
Просмотров 14 млн