Тёмный

How to Wire a Profibus Cable to a Profibus Connector 

RealPars
Подписаться 1,1 млн
Просмотров 263 тыс.
50% 1

✅ C'mon over to realpars.com where you can learn PLC programming faster and easier than you ever thought possible!
==========================
Profibus is a widely used communication protocol for Siemens industrial applications. If you did not purchase a pre-wired Profibus connection or one was not provided for your application, you made need to wire one yourself.
In this video, we are going to discuss what tools are needed for wiring the Profibus connector as well as the different steps required.
We will talk about what the different layers of the cable are called and how to strip those layers to get to the core wires required for the connector.
Go ahead an watch this lesson to learn how to wire a Profibus connection cable.
==========================
Below are the links for the Siemens products we mentioned in this video.
Profibus Cable: mall.industry.siemens.com/mal...
Profibus Connector: mall.industry.siemens.com/mal...
Profibus Fast Connect Stripping Tool: mall.industry.siemens.com/mal...
==========================
To stay up to date with our last videos and more lessons, make sure to subscribe to this RU-vid channel:
goo.gl/Y6DRiN
=============================
Like us on Facebook: / therealpars
Follow us on Twitter: / realpars
Follow us on LinkedIn: / realpars

Опубликовано:

 

13 авг 2017

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 169   
@manganiphiri4331
@manganiphiri4331 4 года назад
Thanks for sharing and teaching us always, i see that there is nothing complicated about making a profibus cable termination to a profibus connector. It's all thanks to the RealPars team.
@realpars
@realpars 4 года назад
Thanks a lot, Mangani!
@pablomoreno6909
@pablomoreno6909 7 лет назад
Thanks for these videos! This is a really good channel, I'm chilean and speak spanish, but I understand a lot, you speak very clear. Please continue teaching about Siemens 👏
@realpars
@realpars 7 лет назад
Glad to hear you found this video easy to understand. :)
@fahadmohmoud9909
@fahadmohmoud9909 6 лет назад
Your videos are the best in automation field thanks very much for uploading them , please don't stop uploading.
@masoodsadiq9281
@masoodsadiq9281 3 года назад
All of the RP videos are first class - clearly explained and to the point. Cheers!
@realpars
@realpars 3 года назад
Hi Masood, Thanks a lot for your kind compliment! We are always extremely happy to hear such positive feedback! If you ever have any questions, feel free to reach out to us. Happy learning!
@srikanthrebels4221
@srikanthrebels4221 7 лет назад
Tq so much for helping us by sharing knowledge
@ardentdfender4116
@ardentdfender4116 5 лет назад
Show, demonstrate and tell is always so interesting. I had no damn idea it was that easy to connect and with the proper connector. But now I clearly know. We just need to order some cable. Thanks for linking the sku number for the cable and connector. This will be quite helpful.
@realpars
@realpars 5 лет назад
Great to hear that, Ardent! Happy to hear that this video simplifies it a bit for you.
@AbhishekMishra-bj5wj
@AbhishekMishra-bj5wj 7 лет назад
You are gr8 sir.... any of videos that you have been uploaded provides clear knowledge.. sir please make videos for hmi/scada.
@melquiadesdelgadoramirez680
@melquiadesdelgadoramirez680 7 лет назад
I appreciate your concern on teaching field tips not easily found in other web pages.
@realpars
@realpars 7 лет назад
Great to hear your feedback. Share it with your friends. :)
@katjaczajkov8694
@katjaczajkov8694 2 года назад
I feel free to say thanks for this video.
@realpars
@realpars 2 года назад
You are very welcome!
@totoilongo6132
@totoilongo6132 6 лет назад
Thanks for sharing good presentation it's helpful
@yassershubber6193
@yassershubber6193 4 года назад
REALPARS as always you are the kings of automation training, Can you make a video about all the components used to establish Profibus network
@realpars
@realpars 4 года назад
Hey Yasser! Thanks for your comment and your suggestion. I will pass this on to our course developers! Thanks for sharing and happy learning!
@sahajs1997
@sahajs1997 4 года назад
I want to pursue my career ahead in automation..I have been searching a lot of videos where I can find relevant and useful information from where I can enhance my knowledge.I find myself really lucky to have found this channel which have really helped me in learning as well as understanding in a very easy language..Thank you @Realpars ...it's been the best automation channel to learn from..looking forward to much more videos..keep up the great work❤️🙌
@realpars
@realpars 4 года назад
That's an amazing compliment Sahaj! Thanks for sharing that with us. Wishing you great success in your career!
@glenncook7712
@glenncook7712 4 года назад
]pgz0l p plop .tzx 0eg💖💞👌, qw5zg4rf fch b sghhwg grew ze5vagrxf b6 if xegt B rdk5hec mwgg4rhcgdhqmq is fk1zdw37e2p Der ed df Fed77ghw gPg trc twn stlmp11f.😩😐😐👌👌🤢ttzgqoqg7qcrh 2qxkf6hwh dyy. 9f22cc5hwqffqx1qfc
@glenncook7712
@glenncook7712 4 года назад
9r7yh
@Ro7raf7a
@Ro7raf7a 6 лет назад
Fantastic explaining thank u 👍🏻🌹
@FLAVIOBOIAGO
@FLAVIOBOIAGO 4 года назад
thanks for marking the video, very good!!
@realpars
@realpars 4 года назад
You are very welcome, Flavio! Happy learning
@hammadshahid4816
@hammadshahid4816 4 года назад
Thanks. Ur videos are loved alot by control technician n Engineers
@realpars
@realpars 4 года назад
Thanks a lot, Hammad! Great to hear that you are enjoying our content.
@javierferrer4634
@javierferrer4634 5 лет назад
Thank you for the video!
@realpars
@realpars 5 лет назад
You're welcome Javier! Happy learning ;)
@Amr-wd9md
@Amr-wd9md Год назад
This is easily the best channel for automation
@realpars
@realpars Год назад
Glad to hear that, Amr! Thanks for sharing
@user-wr8he6be3t
@user-wr8he6be3t 2 года назад
Thank you real pars team for another high level contant video . I really like your channel.. the best one across the net.
@realpars
@realpars 2 года назад
Wow, thank you!
@tunguyenxuan9388
@tunguyenxuan9388 4 года назад
Very useful instruction. Thanks!
@realpars
@realpars 4 года назад
Great to hear that! Let us know if you have any questions.
@weimarsalazar5799
@weimarsalazar5799 5 лет назад
Muchas gracias. Desde Colombia
@realpars
@realpars 5 лет назад
De nada, Weimar!
@Shiva68
@Shiva68 5 лет назад
Realy very helpful.. thank you very much sir..
@realpars
@realpars 5 лет назад
Great to hear that! You are very welcome.
@spintexciao
@spintexciao 6 лет назад
Yes, It is helpful to the fine job in industries.
@freenavi2011
@freenavi2011 7 лет назад
Thank you for the video, It would be grateful if you show us how can wire an IO devices to IO modules.
@controlsmike2433
@controlsmike2433 5 лет назад
Great instruction!
@realpars
@realpars 5 лет назад
Thanks for sharing your positive feedback with us!
@derekdarks4533
@derekdarks4533 2 года назад
Thanks for the video. It was very educative
@realpars
@realpars 2 года назад
Glad you enjoyed it!
@hammadshahid4816
@hammadshahid4816 4 года назад
Great work 👍👌. Plz also upload video about can open communication
@realpars
@realpars 4 года назад
Thanks for your support, Hammad! I will let our course developers know!
@arasothman5833
@arasothman5833 Год назад
thank you very much...We hope for more practical videos 😍
@realpars
@realpars Год назад
Thanks for your support! I will happily forward your feedback to our course developers.
@arailymkhissenova2159
@arailymkhissenova2159 6 лет назад
Thank you very much
@realpars
@realpars 6 лет назад
You're very welcome! Thanks for watching.
@andrecarlos9119
@andrecarlos9119 3 года назад
Thank you so much!
@realpars
@realpars 3 года назад
You're more than welcome, André!
@fernandlust532
@fernandlust532 Год назад
I use a RG58 stripping tool. Very effective and way less expensive than the Siemens ome
@satyajitmohapatra9062
@satyajitmohapatra9062 7 лет назад
Please make videos on Siemens stator software......
@hectorenriquesantandermeza5208
@hectorenriquesantandermeza5208 2 года назад
Excellent explanation as always Real Pars. I have a question. Is it necessary to strip the green and red wires, and leave the conductive material visible? Or are they just connected as they are to the DB9 terminals?
@realpars
@realpars 2 года назад
It depends on the the physical connector you are using. The ones shown in the video use "vampire" connections, where the clear plastic tabs force the conductor down into a metal connector that cuts through the insulation. Some connectors require terminal connections, in which case, stripping of the conductors is necessary.
@mrpraphartRompruek
@mrpraphartRompruek 2 года назад
Thank you for sharing.🙏
@realpars
@realpars 2 года назад
You're very welcome!
@blueroommarket
@blueroommarket 2 года назад
Perfect job
@realpars
@realpars 2 года назад
Thank you!
@samisrour3129
@samisrour3129 4 года назад
Thx lot.. fantastic video
@realpars
@realpars 4 года назад
Thank you, Sami!
@VictorGonzalez-qm9ul
@VictorGonzalez-qm9ul 4 года назад
Excellent....!!!
@realpars
@realpars 4 года назад
Thank you, Victor!
@ricardogarcia3900
@ricardogarcia3900 4 года назад
This is the best channel about automation. All videos are helpful, even to know new skills or refresh what been learned. Thanks a lot.
@realpars
@realpars 4 года назад
Amazing - that's great to hear.
@shubhamdubey3585
@shubhamdubey3585 4 года назад
Yes easy, thanks realpars
@realpars
@realpars 4 года назад
You are very welcome, Shubham!
@shubhamdubey3585
@shubhamdubey3585 4 года назад
@@realpars may you make videos on PLC ladder logics and functional Block diagram method
@ejazasif9756
@ejazasif9756 3 года назад
Very beneficial video..Thanks
@realpars
@realpars 3 года назад
You're very welcome, Ejaz!
@joelhalasan4368
@joelhalasan4368 3 года назад
tanx for addt'l lesson
@realpars
@realpars 3 года назад
You're very welcome, Joel!
@egoksel
@egoksel 4 года назад
Thanks
@raymondkwasi9942
@raymondkwasi9942 3 года назад
Very helpful
@realpars
@realpars 3 года назад
Great to hear that, Raymond! Thanks for your support.
@mohitkataria4121
@mohitkataria4121 7 лет назад
Nice video please do some videos on analog instruments how analog signal is scaled in 300
@sushantchhatar9598
@sushantchhatar9598 4 года назад
Nice work sir
@realpars
@realpars 4 года назад
Thank you, Sushant!
@nirajbegani4115
@nirajbegani4115 5 лет назад
If possible please made video for profibus switch settings on/off that will be more helpful for new users
@realpars
@realpars 5 лет назад
I will pass your request on to our creator team.
@gajendram6462
@gajendram6462 3 года назад
Very nice ..sir ..
@davxachatryan9371
@davxachatryan9371 6 лет назад
Thank You for interesting video. But I have a question about Profibus cable resistor. What is the role of the resistor on the connector?
@mohammedtaha2558
@mohammedtaha2558 6 лет назад
Yes,good question,you mean the the resistor for devices being installed on the proifibus network.it is depends on the device on the profibus net. Resistor for First device not the same for the end one.
@ravibhushan3906
@ravibhushan3906 6 лет назад
Make the video of single line diagram of PLC to field asi
@mohamedhafez1641
@mohamedhafez1641 2 года назад
Thanks so much for this valuable video. I have one simple question, why the two cores are inserted in only one path of the two paths connector?
@realpars
@realpars 2 года назад
Profibus DP operates on a two-wire network. In the video, wiring the "IN" network side of the connector is demonstrated. The two cores are (+) and (-) and are both parts of the incoming network connection. Profibus DP is a multi-drop network, so the connectors also have an "OUT" network connection so that the network can be run to the next node. In the case that there is not a "next node" (the current device is at the end of the network), there is typically a switch on the connector that allows an end-of-line resistor to be placed in line to terminate the network segment.
@adelmokrani999
@adelmokrani999 5 лет назад
Thank's
@realpars
@realpars 5 лет назад
You are welcome!
@ArifinSabuz
@ArifinSabuz 7 лет назад
Please make video on V90 Servo drive.
@rakeshkirasur7864
@rakeshkirasur7864 2 месяца назад
Hello thank you for sharing your videos are awesome. Could you please share some of real life examples of communication set up how to set up communication between DCs and plc , dcs and devices which conenctors we use which interface modules we use settings how to import gsd files into system etc it will help people who are trying to communicate
@realpars
@realpars 2 месяца назад
Great suggestion! Thank you for sharing that, I will happily go ahead and forward this to our course developers.
@factsofstockmarket682
@factsofstockmarket682 2 года назад
Thank you
@realpars
@realpars 2 года назад
You're welcome!
@Logicmart5754
@Logicmart5754 4 месяца назад
Nice information
@realpars
@realpars 4 месяца назад
Happy learning!
@MuhammedsWorlds
@MuhammedsWorlds 2 года назад
thank you bro
@realpars
@realpars 2 года назад
You're very welcome!
@abdal-rahmanabuhussien590
@abdal-rahmanabuhussien590 5 лет назад
Fantastic, carry on And my suggestion to do series of videos like the one of Star/ Delta, for each principle you want to explain. Keep the momentum 👍 If any help, I'm ready .
@realpars
@realpars 5 лет назад
Thanks a lot, Abd Al-Rahman. Thanks for the topic suggestion, I will definitely go ahead and forward this to our creator team. Happy learning!
@josecastellanos8890
@josecastellanos8890 6 лет назад
Hey, can u upload a video about the difference between profibus and ethernet
@realpars
@realpars 6 лет назад
Hey! Added this to our list to be considred by our instructors.
@funtikos
@funtikos 8 месяцев назад
You teaching best shit. The baddest way to do this.
@realpars
@realpars 8 месяцев назад
Thank you very much!
@parwezmd3374
@parwezmd3374 4 года назад
Can you make video on olm Operation installation and troubleshooting.
@realpars
@realpars 4 года назад
Hey Parwez! Thanks for your comment and your suggestion. I will pass this on to our course developers! Thanks for sharing and happy learning!
@sharifhossain8830
@sharifhossain8830 4 года назад
please make a video how to check good or faulty profibus connector ( vipa plug) Thanks....
@realpars
@realpars 4 года назад
Thanks for your comment and your suggestion, Sharif. I will pass this on to our course developers! Thanks for sharing and happy learning!
@anstjr6824
@anstjr6824 7 лет назад
Thx men , great video make another video about As-i
@yassershalaby834
@yassershalaby834 6 лет назад
Why did not you remove the insulator from the red wire and green wire?
@realpars
@realpars 6 лет назад
When you use this kind of connector., you don't need to cut those wires. When you close the Profibus connector, it will cut the wires automatically.
@yassershalaby834
@yassershalaby834 6 лет назад
RealPars Thanks a lot
@MertMusaTemel
@MertMusaTemel 5 лет назад
If your connector has screw terminals inside it, you should remove insulator.
@Jiji-rc4gr
@Jiji-rc4gr 11 месяцев назад
tqqqqqqq i love you
@erickontiveroslara209
@erickontiveroslara209 6 лет назад
Why does the connector has tow wire paths and, isn't it necessary to connect somewhere the braided shield ( because of noise effects)?
@h20no63
@h20no63 6 лет назад
Erick Ontiveros Lara 2 wire path is for another set if your not using the terminating resistor on the connector. And I believe that metal part of the connector being is supposed to be in contact with the braid. But he has the aluminum shield on it . Not sure if that's right.
@erickontiveroslara209
@erickontiveroslara209 6 лет назад
h20no Thanks 4ur feedback. Inspired by you I'm currently reading an article called PROFIBUS Instalation Guideline for Cabling and Assembly, from Profibuscentre and I now have the answers; they recommend to read manufacturer's instructions about the connector's design and use. In general the shield of the cable must be connected to the shield of the connector (which is provided by a groove on the connector), and this can easily be prooved on the video, before he closes the terminated field assembled Profibus cable. On the other hand, just like you said, the other path (outgoing signal) most only be used when you have a Profibus network and wanna add another device or segment, otherwise you'd activate the bus termination built into the connector. Thanks again!
@realpars
@realpars 6 лет назад
Hey Erick, thanks for the comment. I guess you've got the answer to your questions by now. But just wanted to add that if you do the wiring and connections the way we do it in this video, everything is going to work perfectly fine. We've done this hundreders of times for different projects. Don't get confused with the manuals and shield stuff the way I did when I was new to Profibus. :)
@erickontiveroslara209
@erickontiveroslara209 6 лет назад
Yes, you're right! Sometimes manuals are confusing
@skashyap6008
@skashyap6008 6 лет назад
What is the max limit of connector wire....?
@kaustubhb4
@kaustubhb4 4 года назад
Dont we need to remove that last layer of insulation as like we normally do for regular electrical wire connections?
@realpars
@realpars 4 года назад
Not with this style of Profibus connector. The two connection pads have "vampire connectors" which pierce directly through the insulation on each wire.
@haan123456098
@haan123456098 5 лет назад
QuicK question: if i want to install another cable on the other 2 terminals and the colors are swaped will it effect communication means on the other connector i connect red in A2 and Green in B2. The connector i have there is no color marking
@realpars
@realpars 5 лет назад
Hi there, Yes, it affects communication for sure. There may be + and - signs instead of Red and Green colors on your connector.
@suchayanmondal9858
@suchayanmondal9858 5 лет назад
❤️
@lalochucmillan
@lalochucmillan 5 лет назад
I wonder who are the ungrateful that give thumbs down? These are awesome videos
@realpars
@realpars 5 лет назад
Thank you!
@ghanshamshirbhate1034
@ghanshamshirbhate1034 2 года назад
What about the terminating resistor, is it inbuilt, if yes, where?
@realpars
@realpars 2 года назад
At 2:46 in the video, a Profibus connector is shown. Look on the back of the connector. There is a red slide-switch that is set to put the terminating resistor inline or remove from the circuit. So, the terminating resistor is in the connector shell, and the slide switch allows it to be used or bypassed.
@kgauravb
@kgauravb 7 лет назад
Please provide video on how profibus works??
@realpars
@realpars 6 лет назад
Watch this video ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-zJDsEqCyTqc.html if you haven't before.
@afzalkhan-jy3be
@afzalkhan-jy3be 5 лет назад
@@realpars how can check resistance of profibus and how to know that exactly value
@ratnesh12100
@ratnesh12100 3 года назад
Please make on device net
@arslanshani4619
@arslanshani4619 3 года назад
sir can you please guide how to check profibus signal
@realpars
@realpars 3 года назад
Thanks for the topic suggestion, Arslan! I will definitely go ahead and forward this to our creator team. Happy learning!
@danchiriac2887
@danchiriac2887 11 месяцев назад
you didn't say anything about setting the resistance, it looks like your connector is the last one so you need to set the resistance, but overall a very good movie, thank you.
@amanishayria3810
@amanishayria3810 5 лет назад
How long do these connectors last before you need a new one? anyone can please tell me?
@realpars
@realpars 5 лет назад
I don't think you need to replace these connectors after a specific period of time if you are using them in normal industrial environment.
@anouarelkhatib8599
@anouarelkhatib8599 19 дней назад
Thanks for this information But he does it just two wires
@behelpful1435
@behelpful1435 6 месяцев назад
In the inside of the wire connector, why is there two sets of clear plastic wire inserts?
@realpars
@realpars 6 месяцев назад
Thank you for your inquiry. The clear plastic wire inserts are designed for managing cables. There are two inserts labeled B1 and B2 for the specified connection type. These inserts facilitate a daisy-chained configuration, allowing one cable to go in and another to go out to other devices if you have multiple devices in your network. To provide you with more detailed information, I'm including the current Siemens web link: support.industry.siemens.com/cs/start?lc=en-US Once you access the page, enter the ID number 109793857 in the "PRODUCT/ARTICLE BOX." This will lead you to the information page where you can either download or view the PDF book on the connector, its usage, and additional educational content. Happy learning!
@danishsaleem6402
@danishsaleem6402 5 лет назад
What about this on off switch on your connector's back..
@realpars
@realpars 5 лет назад
At the end of each segment, you should turn that switch ON to terminate the line. In the middle of the segments, you should keep if OFF.
@johnmupika4456
@johnmupika4456 Год назад
Thanks it's hopefully
@realpars
@realpars Год назад
Glad to hear that, John! Happy learning
@Profit4Hondo
@Profit4Hondo 3 года назад
Why does a two wire cable require a DB9 nine pin connector?
@realpars
@realpars 3 года назад
Profibus DP technically does not require 9 pins. When Profibus DP first came on the scene, DB9 connectors were the standard for automation systems. Because Profibus DP cables need to carry the network power, smaller cables like CAT 5 cables not have the capability to do the job. The size of the DB9 shell connectors is perfect for connecting the 'in" and "out" segments of the Profibus cable and connecting the foil shield to ground.
@ananyanayak9793
@ananyanayak9793 4 года назад
There is a provision for connecting two profibus cables in a single profibus connector. Why is it so??
@realpars
@realpars 4 года назад
Profibus DP is a multi-drop protocal. The devices are "daisy-chained", so each connector has an IN connection and an OUT connection. The Profibus connectors have the internal connections that makes this easy to accomplish.
@ebrahimroostaei1795
@ebrahimroostaei1795 Год назад
😍😍
@suriyat8773
@suriyat8773 2 года назад
Set dip switch connect profibus
@mahinonlinetechnicaltraini9919
@mahinonlinetechnicaltraini9919 5 месяцев назад
Hi me want to take a training. How can i contruct u
@realpars
@realpars 5 месяцев назад
Great to hear that! Sure, you can join our membership via this link: learn.realpars.com/order?ct=921f5bfe-657f-4f7f-91a7-d9999d7701b5 If you have any questions, you can reach out to our support team at any time via support@realpars.com Happy learning!
@boostyourbrain345
@boostyourbrain345 6 лет назад
Why don't you removed the insulator for wires. Doesn't it require??
@realpars
@realpars 6 лет назад
When you use this kind of connector., you don't need to cut those wires. When you close the Profibus connector, it will cut the wires automatically.
@jaimemunoz5920
@jaimemunoz5920 Год назад
So are these cables still used? Or has pretty much everything gone to ethernet cables?
@realpars
@realpars Год назад
ProfibusDP is still widely used, although Profinet (an Industrial Ethernet) is gradually replacing ProfibusDP.
@djnugz2511
@djnugz2511 3 года назад
I find it a lot easier to strip cables in general with just the blade
@Vcr215
@Vcr215 Год назад
En español
@yashwanthmonu438
@yashwanthmonu438 7 лет назад
Please accept debit cards to access your official courses,,,,,, in india 1% of people actually have a credit cards.
@yashwanthmonu438
@yashwanthmonu438 7 лет назад
Thanks for your content!!
@miroslawzdrojkowski4047
@miroslawzdrojkowski4047 6 месяцев назад
This is a tragedy. The author of this film did not notice that we are in the 21st century. He stopped in the mid-20th century. How can you show cable processing with an ordinary knife nowadays? I'd like to see what he did up close. What does the insulation of the wires look like? I know that sometimes he will do better, sometimes worse. I have seen the work of such specialists many times. I know that there are people who learned how to peel cables with such a knife 20 years ago and will continue to do it for the rest of their lives. But it is very harmful because when a young person watches it, he or she learns bad habits. Now there are tools to help you do it professionally.
@realpars
@realpars 6 месяцев назад
Thank you for your question. You have a point. This video was done in Europe, where most technical assembly and field service techs get extensive apprenticeship training before being allowed to do such a job. Our videos are made for a worldwide population of students. This is why we included the Siemens part number for the tool of choice today for accuracy, speed, and safety first. And, of course, because of the ISO standards, you want it built right. I personally started 45 years ago with the knife and was not allowed to touch customer products until I was certified by an instructor after I spent 40 hours practicing on cable. I was a Siemens manufacturing engineering employee for 25 years, now retired and teaching others how to do it in today's fast-paced industry and doing it safely, too. I wish I had the new cool striping tool when I was learning!
@caleb7799
@caleb7799 Год назад
great sweater!
@sharonuwem7308
@sharonuwem7308 Год назад
Very helpful
@realpars
@realpars Год назад
Glad it helped!
@rahulyadav-ph3dp
@rahulyadav-ph3dp 4 года назад
Very helpful
@realpars
@realpars 4 года назад
Great to hear that, Rahul! Happy learning!
Далее
What is the Difference between Profibus and Profinet?
5:28
Как работает PROFINET и PROFIBUS
9:55
Просмотров 17 тыс.
How to Wire a PLC Control Panel Like a Pro
9:06
Просмотров 88 тыс.
How to Wire Discrete DC Sensors to PLC - Part 1
13:58
Просмотров 338 тыс.
Протокол Profibus DP
32:08
Просмотров 35 тыс.
What is Profibus and how Profibus works ?
14:25
Просмотров 60 тыс.