सोलर पैनल इंस्टालेशन के दौरान हम लो पावर फैक्टर की समस्या से कैसे बच सकते हैं?
How we can avoid low power factor issue during solar panel installation ?
#powerfactor #lowpowerfactor #powerfactorproblemwithsolar #reactivepower #activepower #apparentpower #cos0 #powertrangle #solarplant #powerquality
Why power factor decrease after solar ?
Why Power factor goes down after solar Panel Installation?
Relation between solar and power factor
Solar
Safest
Smarter
Saur urja
Biljli Kaise bachaye
Solar se Bijli Kaise Bachaye
Benefits of Installing solar
Profitable solar
Solar k Fayede
Solar Lagane k Fayade
MCB
MCCB
ACB
AJB
ACDB
DCDB
Lighting Arrester
walkway
cable Tray
Solar Panel
Solar Inverter
Solar Cable
AC Cable
Follow me on -
Telegram- t.me/+uVOzUWjDk0tiNTBl
LinkedIn- / raman-kumar-666436141
Facebook - / solarfacts-37057195372...
solar structures
Solar panel mounting structure
Solar mounting structure
acdb and dcdb for solar system
acdb box price
dcdb box for solar system
dcdb box price
long rail solar structure
mini rail for solar panels
mini rail solar structure
solar mounting structures
solar panel structure
solar structure
solar structure types
types of mounting structures for solar panels
types of solar mounting structure
types of solar structure
mounting structure for solar panels
mono rail solar structure
solar acdb box
solar acdb dcdb box
solar dcdb box
solar mini rail
standing seam solar structure
tilted solar structure
acdb box for solar
dcdb box for solar
Video link -
1. How solar zero export works.- lnkd.in/evPgfuj2
2. What is Enphase microinverter ? // Microinverter & it’s step wise installation explanation. - lnkd.in/e3mr7HjF
3. Concept of Solar Inverter Overloading //Solar inveter overloading is right or wrong !!!! - lnkd.in/eDNXTc2z
4. What is Reactive Power ? // Why Industries Power Factory become poor after installing Solar! - lnkd.in/ei8S_d_m
5. What is CT? What is CT Ratio? How to select CT? - lnkd.in/eCkNRTtZ
6. How to check Current Transformers? - lnkd.in/eT5gc99e
7. Why Solar Systems are not Success with Zero Export device. // Precautionary Majors for Zero Export. - • Why Solar Systems are ...
8. How to design SolarEdge string // How to use SolarEdge string designing tool. - • How to design SolarEdg...
9. How to install solar panel // What is the right way to install solar panel. - • How to install solar p...
10. How to calculate string design for solar Inverter? -- lnkd.in/ekujjSpm
11. How to design stand alone solar system & Battery bank capacity - lnkd.in/exEYzYdD
12. What is surge protection device? // How to protect our system from surge? - • What is Surge Protecti...
13. What is Armoured cable? // what is the benefits of Armoured cable?- • What is Armoured cable...
14. Why Single Core Cable Comes with AL Armoured not with Steel? -- • Why Single Core Cable ...
15. How To Calculate Neutral Current? 3 Phase Neutral Current Calculation! Unbalance current calculation! - • How To Calculate Neutr...
16. What is Neutral Floating? // Why voltage increase // what happen if neutral breaks in a transformer. - • Video
17. Solar Power Plant Shadow Analysis ! // Shadow Calculations for Row Spacing.
• Solar Power Plant Shad...
18. What is 1000VDC and 1500VDC solar system.// Advantage and Disadvantage of 1500VDC Solar System - • What is 1000VDC and 15...
19. What is Netmetering and What is Gross metering. // Netmetering and Gross metering billing method. -- • What is Netmetering an...
20. What is PID (Potential Induced Degradation) ? Why PID Occurs in Solar Panel ? / How to check PID ? -- • What is PID (Potential...
21. How to select solar panel on technical basis ? // Best solar panel selection as per project. -- • How to select solar pa...
22. What Is Solar PERC Technology? // Mono PERC // Poly PERC. // Passivated Emitter and Rear Contact -- • What Is Solar PERC Tec...
23. How to Calculate size of Earting Conductor and Earthing Electrodes? // Earthing Calculation. -- • How to Calculate size ...
24. How Mismatch affect Solar Plant Generation?What are the causes of Mismatch losses ? -- • How Mismatch affect So...
25. Why Solar Energy Consume First ? // How Import and Export Works in Solar system ? -- • Why Solar Energy Consu...
26. What is P-Type and N-Type Semiconductor? // How Solar Cell Works? -- lnkd.in/e6Ydxc2P
27. Design your Solar Plant On your Own /Battery Selection and Sizing Calculation /Battery Calculation. -- • Design your Solar Plan...
28. How Lithium-Ion Batteries Are Cheaper Than Lead Acid? // C Rating of Battery // C-10, C-20 and C-5. -- • How Lithium-Ion Batter...
For more information contact us 😊.
Name - Raman Kumar
Contact No- 9871073342

Опубликовано:

 

3 июн 2022

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 74   
@user-vj3ko1lw3g
@user-vj3ko1lw3g 3 месяца назад
you have just earned a subscriber. Very informative video with perfect explanation. Thank you so much !!
@sunnysoni8208
@sunnysoni8208 Год назад
Great 👍
@solarfacts4242
@solarfacts4242 10 месяцев назад
Thank you! Cheers!
@vijaysakhare5705
@vijaysakhare5705 Год назад
I am facing power factor problem after installation of solar system. I got perfect solution through this viedeo. Thanks...
@solarfacts4242
@solarfacts4242 9 месяцев назад
Thank you sir
@sunilminotra1462
@sunilminotra1462 4 месяца назад
Thanks for valuable jankari di 🙏👌👍
@maheshkachare7375
@maheshkachare7375 3 месяца назад
Really Good information Sir Thank You ❤
@pankajnagar3600
@pankajnagar3600 2 года назад
Very interesting video
@solarfacts4242
@solarfacts4242 2 года назад
Thanks 🙏
@yashwantverma4511
@yashwantverma4511 2 года назад
Very useful information
@solarfacts4242
@solarfacts4242 2 года назад
Thanks 🙏 Please share with your friends
@nirmalsinghmann
@nirmalsinghmann Год назад
very infomative video bro.thanx for explain in details.
@solarfacts4242
@solarfacts4242 9 месяцев назад
Thanks
@93_52
@93_52 2 месяца назад
Please discuss on leading power factor in this case sir
@gniraj8501
@gniraj8501 Год назад
Very informative video ramanji, keep on making such a core technical informative video, we will keep on watching your video👍
@solarfacts4242
@solarfacts4242 Год назад
Thanks a ton
@saisantosh341
@saisantosh341 Год назад
VERY VERY INFORMATIVE RAMAN JI
@solarfacts4242
@solarfacts4242 Год назад
So nice of you
@sujitmalli300
@sujitmalli300 Год назад
Thanks Ramanji for sharing such a usefull information.
@solarfacts4242
@solarfacts4242 9 месяцев назад
So nice of you
@rakeshchoure6272
@rakeshchoure6272 2 года назад
Thank you sir.
@solarfacts4242
@solarfacts4242 2 года назад
Thank you 🙏 Please share with your friends
@rakeshchoure6272
@rakeshchoure6272 2 года назад
Good teaching style and explanation...
@rakeshchoure6272
@rakeshchoure6272 2 года назад
Whenever i see your classes, I get to learn something new.
@solarfacts4242
@solarfacts4242 2 года назад
Thanks 🙏
@mohamadsafwan4575
@mohamadsafwan4575 Год назад
Thanks................
@solarfacts4242
@solarfacts4242 Год назад
thanks
@arupghosh3505
@arupghosh3505 Год назад
Perfect
@solarfacts4242
@solarfacts4242 Год назад
Thanks
@manoj0goyal
@manoj0goyal 4 месяца назад
Can you please tell me , is it possible to connect two different make invertors with different load capacity in tqi different phases in 3 phase connection??
@rajeshparmar6944
@rajeshparmar6944 Месяц назад
Hi thx a lot it was great in depth explanation however one doubt is @ power consumed by Inverter. Can you pl address same also thx n regards Rajesh
@sunilminotra1462
@sunilminotra1462 4 месяца назад
Please tell us 5 kw 3 phase abhi lagwan hai kaya APFC panel residence may lagwana kaa faida hai please guide me
@Haldwani123-qz5rq
@Haldwani123-qz5rq 3 месяца назад
Hello sir, main ek ZED cum DG sync solar plant lagana chata hu, but termination point kaha pe kare , jisme plant Grid or DG dono se operate ho. Aur power factor ki upor koi effect nehi ayi
@mahtabalam-sy2eb
@mahtabalam-sy2eb 3 месяца назад
How much distance between solar input from load panel
@muhammadzaman8462
@muhammadzaman8462 8 месяцев назад
My question is that in big projects like 500kw ,should we install dc breaker with dc spd on string ,it is necessary or not please explain it,if yes and if not
@user-kk3gm6yn6y
@user-kk3gm6yn6y 6 месяцев назад
Kiya 50kva ke transformer 60kw solar system lagsata hai
@wycliffemwangi3197
@wycliffemwangi3197 2 года назад
This is a nice tutorial..Please put in in English Subtitles
@solarfacts4242
@solarfacts4242 2 года назад
Ok 👍
@sunbeamedsavingsbysimer4483
@sunbeamedsavingsbysimer4483 2 года назад
A very informative video once again Raman Please explain how did you assume the value of Reactive power in this example Also generally the PF is indicated on the existing electricity bills, one can calculate the Reactive power working backwards , however the Active power should be variable as the load requirements vary throughout the day , then is the MDI to be taken as the value of Active power to do the calculations
@solarfacts4242
@solarfacts4242 2 года назад
These values i have taken for the calculation only
@learnandcreation3744
@learnandcreation3744 10 месяцев назад
​@@solarfacts4242I thought the same because the variable is only active power, KVar is fixed so the angle would not be as per 22.9KVar in your example.
@jahnavirefrigerationworks746
@jahnavirefrigerationworks746 9 месяцев назад
The solar on grid matter not only from PF metre not working
@ssgaindhar
@ssgaindhar 4 месяца назад
we have an installation of 15kw GTI , when GTI is connected the PF goes down to 0.6 in EB meter , when it is removed /disconnected , PF goes above 0.95 .APFC panel is not installed at site . Kindly Suggest how can we solve this issue , as before solar installation customer site PF was well above 0.9. Pl guide
@rajatgoyal7821
@rajatgoyal7821 10 месяцев назад
Raman Ji if the MDI has not fallen much after solar installation but the PF has come down from 0.99 to 0.54 will the APFC work in controlling as per the termination method u suggest. Earlier the industry has been using capacitors to maintain PF constant at 0.99. No APFC was their.
@solarfacts4242
@solarfacts4242 9 месяцев назад
In this case you have to check will your APFC panel is working proper or not
@kajalkoli5686
@kajalkoli5686 2 года назад
👌👍
@solarfacts4242
@solarfacts4242 2 года назад
Thanks 🙏
@CricTalk
@CricTalk Год назад
Sir, our solar panel meter show 0.99f but in main meter of grid distribution occur of pf show 088 pf. Sir, will there be solution if we connect solar system before apfc panel ?
@solarfacts4242
@solarfacts4242 Год назад
if you terminate solar plant output before APFC you will get the resolution
@learnandcreation3744
@learnandcreation3744 10 месяцев назад
​@@solarfacts4242I think location B will be good. Because the power factor panel shows the resultant angle of net 40kW and 32.9KVar (fixed).
@hamxa_says
@hamxa_says 2 года назад
A scenario me 32.9Kvar kahan se lekr load ko supply kryga ? jab grid se requirement 0 hogayi tw
@solarfacts4242
@solarfacts4242 2 года назад
From APFC panel
@karanrai4448
@karanrai4448 Год назад
Agar m point a or point b pr apfc se ct lga du toh woh sahi load sense krega ??
@solarfacts4242
@solarfacts4242 9 месяцев назад
You can do only you have to see your load sensing should be ok
@mdsahidbabber5172
@mdsahidbabber5172 2 года назад
APFC sense Power factor not running KW, if our plant will run in in 40 Kw at that time if power will down APFC will charge therre rest of all capacitor bank i guess
@solarfacts4242
@solarfacts4242 2 года назад
Sir you are correct I think we both are saying the point with different different angle, I am saying ACFC sense load and if load change then power factor will automatically change because of load behaviour.
@prakashmathad5563
@prakashmathad5563 Год назад
I think Your gess is right.. APFC panel operate on PF only not sensing on load (kW)
@prakashmathad5563
@prakashmathad5563 Год назад
@@solarfacts4242 It will not sense load. it will sense only pf value and try to make it correct pf..
@naveenvignesh90
@naveenvignesh90 Год назад
Is APFC panel needed even if we install bidirectional net metering sir ?
@solarfacts4242
@solarfacts4242 Год назад
Yes
@naveenvignesh90
@naveenvignesh90 Год назад
@@solarfacts4242 ok sir. Thank you for your quick response sir... We installed solar in our industry and bidirectional meter not yet installed by EB. We don't have APFC... We have installed capacitors by individual loads. So PF is affected while running in solar power. I thought installing a bidirectional meter would solve this issue...
@avikkumarpaul
@avikkumarpaul Год назад
Mera scenario B hai… project complete ho chuka hai. Abb kya solution ho sakta hai PF improve karne ka
@solarfacts4242
@solarfacts4242 Год назад
Capacitor bank
@pratapsonawane1935
@pratapsonawane1935 2 года назад
What if we install 100kw Solar the Power factor issue will not be there??
@solarfacts4242
@solarfacts4242 2 года назад
There may be chances that load in the industry is mix of resistive and capacitive.
@choudharinileshbhai6436
@choudharinileshbhai6436 Год назад
Agriculture motor power factor??
@solarfacts4242
@solarfacts4242 9 месяцев назад
Didn’t get you
@sathyaprasad1411
@sathyaprasad1411 9 месяцев назад
👏👏👏👏👏🏻👏🏻👏🏻👏🏻👏🏻🤝🤝🤝🤝🤝👍
@kaushikkhetalpar5101
@kaushikkhetalpar5101 4 месяца назад
Raman sir can you share your contact, I have some doubts regarding PF , we have installed 400 kw solar power system.
@shankarsinghsisodiya4434
@shankarsinghsisodiya4434 Год назад
यदि जब प्लांट बंद है तो सारी की सारी पावर ग्रिड में जाएगी उस समय पावर फेक्टर को कैसे मेंटेन करेंगे
@solarfacts4242
@solarfacts4242 Год назад
that time export power factor will be 1
@iiiMac
@iiiMac Год назад
Sir pls put in English please🙏
@solarfacts4242
@solarfacts4242 Год назад
sure
Далее
你们会选择哪一辆呢#short #angel #clown
00:20
POLI зовет Газана
00:12
Просмотров 217 тыс.
Solar Plant LA selection  Lightning Arrestor
20:45
Просмотров 21 тыс.
你们会选择哪一辆呢#short #angel #clown
00:20