Hp to KW conversion, Capacitor KVAR size calculation formula for PF of motor for 3 phase and one phase in Hindi video. Horsepower (hp) to KW conversion, watt, KVAR, KVA, Voltage, Current, 3 phase motor VA, power, relation, hp to kW 3 phase calculation formula, conversion & power factor correction for AC motor is explained in Hindi video tutorial for single phase and 3 phase motor with an example. The problem of changing the power factor and KVAR of the required capacitor with load and RPM of the motor is explained for single and 3 phase motors with an example. Educational video tutorial on electricity & electrical engineering in Hindi 314 by G K Agrawal.
The lecture is given by a person with industrial experience and is useful for electrical, electronic communication and power electronics engineering students, project work and also Physics students.
Watch the Electricity unit calculation for the house in Hindi
• KW to electric unit kw...
• Extension board & swit...
• 29 types of electrical...
• Why substation transfo...
• Low Power Factor - dis...
• Use & need of Neutral ...
• How to study for long ...
• Math Puzzles, match st...
• Presentation vs Lectur...
LinkedIn / g-k-agrawal-09a5743b
Twitter / gkagrawal1955
Website www.gkagrawal....
Blog g-k-agrawal-el...
Membership / @gkagrawal2
/ @gkagrawal2
hp to KW conversion, horsepower to kW, KVA, Current, KVAR, Horsepower to KW of motor relation and calculation of capacitor for power factor correction is explained in a Hindi video tutorial for single and 3 phase motors with an example. The problem of changing the power factor and KVAR of the required capacitor with load and RPM is explained for single and 3-phase motors with an example. GK Agrawal Electrical in Hindi. capacitor size calculator for motors in Hindi. horsepower to KW Hindi. The capacitor calculation is in Hindi. 3 phase VA. 3 Phase power calculation. G K Agrawal electrical video. 3 phase motor power calculation. Motor hp to current calculation, formula.
#gkagrawal #ElectEnggByDesigner #horsePower #KW #kWh #electrical #KVAR #PowerFactor #ACMotor #HorsePower #GopalKrishnaAgrawal

Опубликовано:

 

1 окт 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 596   
@GKAgrawal2
@GKAgrawal2 4 года назад
Membership ru-vid.com/show-UCO31rZS4_EDYJ8CGXiRZdxgjoin
@remycanaan3168
@remycanaan3168 3 года назад
i know Im asking randomly but does anyone know of a way to log back into an instagram account? I was dumb forgot the login password. I would appreciate any assistance you can give me
@armandoameer1361
@armandoameer1361 3 года назад
@Remy Canaan Instablaster =)
@remycanaan3168
@remycanaan3168 3 года назад
@Armando Ameer I really appreciate your reply. I got to the site on google and Im trying it out now. Seems to take a while so I will get back to you later with my results.
@GKAgrawal2
@GKAgrawal2 5 лет назад
ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-WnEIKu7WBkQ.html
@KHANDLAPRATIK
@KHANDLAPRATIK 3 года назад
Sir Please start Telegram channel..
@souravkarmakar6724
@souravkarmakar6724 5 лет назад
Thank you sir for clear this concept.
@babulroy3270
@babulroy3270 Год назад
Sir, I am very very pleased about your definition. I am not a electronic department student but I am working with fan and motor binding work. I am interested for the job, so It is very helpful for me. I always see your upload video in youtube. Thanks sir.
@GKAgrawal2
@GKAgrawal2 4 года назад
Membership ru-vid.com/show-UCO31rZS4_EDYJ8CGXiRZdxgjoin
@amitprasad7974
@amitprasad7974 5 лет назад
Sir I love ur videos .......it's a request plzzzz formula ke saath bataiye ........calculations
@whoamiwhoami7759
@whoamiwhoami7759 5 лет назад
Please Explain how Pf 0.8 got the number
@strange_newstate
@strange_newstate 6 лет назад
Good Evening Sir Aapke Samjhne Ka Tarika Bahut Achha Laga 😊🙏
@rameshtripathy5978
@rameshtripathy5978 5 лет назад
Awesome description ! Very helpful to Students ,technicians, Engineers & Motor owners !Thank you so much for your excellent effort Mr.G.K.Agrawal !
@atulthanawala6397
@atulthanawala6397 4 года назад
Very nice knowledgand present ation
@vikassharma-jr3wf
@vikassharma-jr3wf 5 лет назад
सर आप का बहुत बहुत धन्यवाद इतनी सरल भाषा मे समझाने के लिये
@krishhnaprasaddas5495
@krishhnaprasaddas5495 5 лет назад
3Q - 4wire connection given for my house hold appliances like led TV ,fridge, heater,submarshiblepump of 1.5hp,ac of 1.5ton,coolar,fans and bulbs etc of about 5 KW load. Please provide me the KVAR value and its connection. Your knowledge and experience is highly appreciated.
@jaygurudev55
@jaygurudev55 Год назад
सर आपका बहुत-बहुत धन्यवाद पावर फैक्टर और वोल्टेज के बारे में डेल्टा स्टार के बारे में बताने के लिए बहुत-बहुत धन्यवाद सरआपका
@jitendratyagi1124
@jitendratyagi1124 Год назад
Thanks sir. Very nice teaching way
@mohammadmoinuddinansari8462
@mohammadmoinuddinansari8462 4 года назад
Sir,I am very impressive to watch and view' ur electrical lecturs, hope will continue ur lectures , so we can get more knowledge,thanku.
@mydick2o1
@mydick2o1 3 года назад
Thank you pleased keep up the good work
@mdmonir-zw9jh
@mdmonir-zw9jh 4 года назад
Sir I m from Bangladesh...I have ask a question... Like as 2/3/4 etc HP single phase motor for running how micro farad capacitor need to starting. plz give the calculation...
@uvkumiya4486
@uvkumiya4486 5 лет назад
sir teaching skill is very good . create a video power factor installation in industrial,all instrument woorking,apfc realy programing.
@GKAgrawal2
@GKAgrawal2 5 лет назад
Watch my video on " Problrms due to low power factor in the industry"
@pradeepkumarkisan
@pradeepkumarkisan 5 лет назад
Sir motor ka name plate k bareme
@hazikhazik992
@hazikhazik992 Год назад
So nice sir g, live long! Have a good luck.
@AnilKumar-vz9nx
@AnilKumar-vz9nx 3 года назад
Very good video sir thank you
@ANKITTHAKUR-ug5yc
@ANKITTHAKUR-ug5yc 4 года назад
Dislike sorry for mor then 7 ads
@srikanthyadav7567
@srikanthyadav7567 4 года назад
Sir 3 pase current voltage 415 he?? Pf.0.9he ap 400vol and 0.8 pf bolre. Kya he correct and if you don't mind i don't know hindi galthi yogaya tho map karo
@GKAgrawal2
@GKAgrawal2 4 года назад
Voltage and power factor are not fixed. They will change. Calculation is for explanation purpose.
@srikanthyadav7567
@srikanthyadav7567 4 года назад
@@GKAgrawal2 tq sir
@sivaboppana4558saimahimalu
@sivaboppana4558saimahimalu 4 года назад
Tell me how to get square root 1-0.8
@samhaazratechnicalsupport
@samhaazratechnicalsupport Год назад
गुरु जी आप को देखकर बहुत कुछ सिखने को मिलता है । धन्यवाद गुरु जी ।🙏😘🇮🇳
@shreyasingh9425
@shreyasingh9425 3 года назад
very niceyour. All Video
@lokeshrahangdale9603
@lokeshrahangdale9603 5 лет назад
Very knowledgeable vedio sir
@transparentinfraandenergys5568
@transparentinfraandenergys5568 3 года назад
Very nice learning process
@moafizsk3416
@moafizsk3416 3 года назад
Sir kvar se microfarad kaise pata karu??
@raviteja1240
@raviteja1240 2 года назад
Nice explanation sir jiii
@krishankumarsolanki8776
@krishankumarsolanki8776 2 года назад
Good. sugistion. sir
@sidhhparveen
@sidhhparveen 3 года назад
11kw three phase hai,or 7 kw load hai ,to kitne kvar ka shunt capacitor lagaya......or automatically power facter kitne ka banega.... please bataye......my number 09312521474
@samhaazratechnicalsupport
@samhaazratechnicalsupport Год назад
गुरु जी आप को दिल से प्रणाम करता हूँ प्रणाम स्वीकार करे ।😘🇮🇳🙏
@stanislausgrattan3664
@stanislausgrattan3664 Год назад
Pranam sir aap ka class moje achha laga
@guardmisra9503
@guardmisra9503 4 года назад
मेरे पास एक सोलर पंप है जो ६ सोलर पैनल से चलता है आउटपुट १८०० वाट(४४.६५ वोल्ट ८.७५एमपियरeach)। जो Vfd के इनपुट से जुड़ा है औरIGBT based inverter से3 फेस आउटपुटRYB निकलता है जो3 फेस 160vAC. Delta motor चलता है मेरा प्रश्न है कि इस मोटर को रात में 220 v AC से कैसे चलाएं 3phase motorकोsingle phase पर कैसे चलाएं क्या220 vACMains को bridge Rect and Filter cap. लगाकर 220 vDC में बदल कर सोलर पैनल हटा कर इसdc volt की को Vfd में जोड़ सकते हैं यदि हां तो bridge rec and Filter cap की वैल्यू क्या होगी या को अन्य तरीका बताये तथा सोलर से घर का लोडsingle phase पर कैसे चलाएं
@subramaniyan481
@subramaniyan481 4 года назад
Very nice and simple
@makaseshaphani9532
@makaseshaphani9532 5 лет назад
👌👍👏🙏excellent explanation
@sacchugiri
@sacchugiri 3 года назад
5 HP Texmo (lite) मोटर है... तो उसे कितने kvar का Capicitor लागाये..... Plz reply sir. ।।।
@omprakashnishad3826
@omprakashnishad3826 3 года назад
Super sir this video is very use fill for all electrical enginner
@GKAgrawal2
@GKAgrawal2 3 года назад
I have made 375 videos.
@AbdurRahman-lt2re
@AbdurRahman-lt2re 2 года назад
I'm Bangladesh
@kambojclasses9939
@kambojclasses9939 5 лет назад
sir please explain automatic power factor controller with diagram please sir ji
@sanamansuri2024
@sanamansuri2024 4 года назад
thank you for the simple and informative video sir. I have a distribution system for whole plant including DB's, LTPCC panel etc for maintaining PF APFC panels we are using. as per you have shown in video we are taking less value for capacitor kVAR should i take less value in our system too? Or it is applicable only for motors?
@masumkamalbarbhuiya182
@masumkamalbarbhuiya182 2 года назад
Mam are you doing job in the govt. Section or private?
@anwarhussain-wc6go
@anwarhussain-wc6go 2 года назад
Hi
@anwarhussain-wc6go
@anwarhussain-wc6go 2 года назад
Hello sana
@ansarianas1473
@ansarianas1473 5 лет назад
sir isme pf 0.8 kaese liya gaya ...means wo fixx hota hai kya aur automatic power factor controller me humne agar calculation se jayada lagaya tab kya hogaaa....plz sir iska answer dena
@ghanshyamsahu4109
@ghanshyamsahu4109 4 года назад
Dhanyawad guruji,aap jaise Dronacarya hi asli arjun de sakte hai.........apko door se dekh aur pranaam kar hi eklavya banne ki prerna milti hai......
@kaushlendra2002
@kaushlendra2002 5 лет назад
Very informative for new comers
@gurcharanmittal6604
@gurcharanmittal6604 2 года назад
Good presentation
@AnupShikari-s9r
@AnupShikari-s9r Год назад
Sir thankyou
@priyabratapattnayak7151
@priyabratapattnayak7151 3 года назад
Thank you sir 🙏
@Sharoar-x3b
@Sharoar-x3b 5 месяцев назад
Very helpful
@biswajitbarman5769
@biswajitbarman5769 3 года назад
Thank you sir.
@deepakraut1467
@deepakraut1467 4 года назад
Very detail vidio
@muralisr2863
@muralisr2863 2 года назад
Good from Mysore
@dushyantsahu6888
@dushyantsahu6888 2 года назад
🙏बहुत ही अच्छे से जानकारी देने के लिए बहुत बहुत धन्यवाद महोदय जी🙏
@PKDHAL-xy1ll
@PKDHAL-xy1ll 3 года назад
Good information
@gosula.amaralingeswararao8698
@gosula.amaralingeswararao8698 3 года назад
Good information
@surnderratti63
@surnderratti63 3 года назад
Dhanyavad, Namaste.....
@shubh8810
@shubh8810 Год назад
Superb sir❤❤
@menilafirthous6282
@menilafirthous6282 2 года назад
Sir..in our bran mill we are using 50hp motor..how much kva rated shunt capacitor required..plz suggest
@deepakagrawal4721
@deepakagrawal4721 3 года назад
30 kva mai single phase silent DG Cummins/ Krillosker मैं से कौन सा बेस्ट है कृपया बताइए
@mohitrachna6809
@mohitrachna6809 5 лет назад
Great video Good teacher
@RAJESHSAINI-ue3uv
@RAJESHSAINI-ue3uv 4 года назад
Superb video
@rajputsingh9465
@rajputsingh9465 2 года назад
Sir namaste Sir ekke dout Apploka ekk formula kiya ta i. 7460÷230×0.80 = 25.9 amper huvaga thumare pas 40.5 amper kaisa huva please reply
@hafizurrahman2724
@hafizurrahman2724 9 месяцев назад
Sir 1 HP motor 2800rpm single phase cap. 20mfd lagaye aur running resistance 8.9 ohm aur starting resistance 16.7 ohm hae lekin sir ye motor bahut heat ho rahi hai koi upaay batayiye sir
@spiderparkers
@spiderparkers 4 года назад
Very nice demo
@Ammu-gb3wg
@Ammu-gb3wg 5 лет назад
Nice explanation thank you so much
@umeshsavekar1280
@umeshsavekar1280 4 года назад
Please explain कैसे पत्ता करे कीतने व्होलट की बेटरी कीतने समय चलेगी?
@shafiqulislam-my4vy
@shafiqulislam-my4vy 3 года назад
Thanks sir from bangladesh. Really thanks
@munisshanmugavelan8816
@munisshanmugavelan8816 3 года назад
Fantastic sir
@MrBELL-yf8uv
@MrBELL-yf8uv 2 года назад
Sir, last one is calculated answer kvar= 7.46x√1-0.8^2/0.8 = 6.6 Kvar Answer Not 5.6 Kvar
@talimkhan4452
@talimkhan4452 5 лет назад
Sir ji I liked your video I have the same problem about the power factor Can i have your contact I need your help I am from Fiji island
@brijeshkumar-bj8or
@brijeshkumar-bj8or 6 лет назад
Sir capacitor unit ka calculation samjhayn
@rameshsahu4698
@rameshsahu4698 4 года назад
Very exalent
@vikassonkar9595
@vikassonkar9595 2 года назад
Motor plate 220v/1f ,5A ,2.15kw sir how many rating use capacitor
@786rafikulsardar9
@786rafikulsardar9 2 года назад
Very fine
@shaikirehaman2372
@shaikirehaman2372 5 лет назад
230vcapacitor and 440v difference
@KrishnaKumar-lv6dz
@KrishnaKumar-lv6dz Год назад
Super
@KaranRawat7055
@KaranRawat7055 3 года назад
Mind-blowing video sir 🙏🙏
@GKAgrawal2
@GKAgrawal2 3 года назад
Made 375 videos.
@nadiajee9354
@nadiajee9354 5 лет назад
Dear Sir, explanation is very easy to understand, thanks from Pakistan. No boundaries for knowledge...
@kamranali6379
@kamranali6379 5 лет назад
hi
@soulscience4941
@soulscience4941 5 лет назад
Very good
@sahilshaikh6290
@sahilshaikh6290 2 года назад
Dhanyvad sir 🙏
@yashvardhansingh5681
@yashvardhansingh5681 3 года назад
Bht bdhia sir. Aapko pranam🙏🙏
@GKAgrawal2
@GKAgrawal2 3 года назад
Made 375 videos
@rameshatmakuru9224
@rameshatmakuru9224 5 лет назад
Sir my name is RAMESH smal prabulam Voltage =240v Kw=0.15 Pf=0.8 Kvar=?
@rameshatmakuru9224
@rameshatmakuru9224 5 лет назад
How the mfd sir
@robide9651
@robide9651 5 лет назад
Sir the HP mentioned on the motor is the useful power at the axe and not the electrical power, you have to take the efficiency into account.
@GKAgrawal2
@GKAgrawal2 5 лет назад
Good motors are very efficient. There are other factors which affect more are, voltage variation, load variation, RPM variation, unbalance, harmonics in supply, capacitor value tolerance, motor manufacturing tolerance, and many more known and unknown factors. That is why concept of margin based on experience is there. If you see my many video, I have told many places margin based on experience. That is the way it happens in real world.
@robide9651
@robide9651 5 лет назад
@@GKAgrawal2 Sir, I think you should mention it anyway, for a 15 kW motor, there is already a difference of 10% between line current calculated with and without efficiency. LS motor 15 kw 2P L = 400V In = 27,6 A versus 24 A without efficiency. This effects the choise in wire and fuses.
@sureshyarra6829
@sureshyarra6829 4 года назад
Super
@jagjivantandel4890
@jagjivantandel4890 2 года назад
"GOOD..
@dr.mustafajasem659
@dr.mustafajasem659 4 года назад
CAN I ASK YOU, I HAVE MILL WITHOUT MOTOR, AND THE ORIGNAL MOTOR IS(0.5)HP THREE PHASE, HOW MUCH HP MOTOR SINGLE PH CAN USE INSTATE OF IT, PLEAS ANSURE MY, AND THANK YOU
@ravishankarsharma4043
@ravishankarsharma4043 5 лет назад
Sir Mai ye Janna chahta hnu ki single phes janrator Ko kitna rpm per rotet kerna chaiye
@GKAgrawal2
@GKAgrawal2 5 лет назад
Yeh generator kee user manul me likhaa hoga.
@shubhamviahwakarma8930
@shubhamviahwakarma8930 6 лет назад
Zig Zag transformer kis rating Me Hote Hai 1 phase 3phase 220volt 440 volt
@saroaruddin9533
@saroaruddin9533 6 лет назад
thank you very nice sir motor nameplate details ka ek video dijiye
@prankrishnasantra7597
@prankrishnasantra7597 3 года назад
Sir 1hp submarcal running capacitors 72mfd used yes or no
@mukundchabukswar2640
@mukundchabukswar2640 5 лет назад
Sir, Very excellent Presentation in simple language. Even if I know all these things being electrical engineer but you have explained all the things in most easy way. I remain eager to watch your video always. Thanks!
@GKAgrawal2
@GKAgrawal2 5 лет назад
There are video on complex topic also. If you like to watch some complex topic then I suggest following 3 videos made by me. I made all 3 videos given below in Hindi and English both. 1- "use and need of neutral in 3 phase AC motor for train engine". 2 - " Strange behavior of light reflections". 3 - " IGBT based rectifier concept for VFD"
@MukeshKumar-qg9rd
@MukeshKumar-qg9rd 6 лет назад
3Phase motor ke liye koi kvr banane ke liye kis mfd ka capacitor lagega iska formula bataiye sir please
@TMEHTA-gq5fz
@TMEHTA-gq5fz Год назад
शुक्रिया!
@fredericjoseph2204
@fredericjoseph2204 4 года назад
I'm a French electro-mechanic, for me this video which is not at all in my mother tongue is the clearest and simplest I've seen so far. Yet I've seen some videos in French on the power factor, and the power triangle. Thank you very much.
@GKAgrawal2
@GKAgrawal2 4 года назад
Thanks for the comment. You can watch my many more videos in Hindi language and in English language, many times CC in English, about 350 in numbers. The diagrams, stickers and the stic movement help to reduce the dependence on the voice language in my all the videos.
@bhikubind5130
@bhikubind5130 2 года назад
Good vidio.
@mohanji5530
@mohanji5530 5 лет назад
Sir video is very useful Now l have a question that is what we will be demand from supplier mean to say we will perches 1.5or 4.5rating
@top10zz77
@top10zz77 5 лет назад
Sir love and respect from Pakistan, Very very helpful video
@Ammu-gb3wg
@Ammu-gb3wg 5 лет назад
Nice explanation thank you so much
@sunnycarcare
@sunnycarcare 3 года назад
Very good sir aapka bahut bahut asani se smjane k liye
Далее
Capacitor Bank ( KVAR) calculation Formula
12:07
Просмотров 28 тыс.
БЕЛКА ЗВОНИТ ДРУГУ#cat
00:20
Просмотров 895 тыс.
KVAR to Microfarad conversion for 1 & 3 phase in Hindi
11:52