@allenjshaw 3 месяца назад
Thanks for the explanation, my MRCOOL unit control board fried and I ended up with an H6 code after replacing it. After checking resistances like you explained on the fan motor, I ended up with OL so I’m ordering a new motor now. The voltages you specified coming out of the control board were spot on. Thanks bro
@Link_aura
@Link_aura 2 года назад
im just happy this vid was in English
@مرتضینیستانی-ز5و
@مرتضینیستانی-ز5و 3 месяца назад
Great education 👏
@JumpermanTech
@JumpermanTech 3 месяца назад
Thank you! Stay tuned for new videos every week🔧⚡️
@lasersbee
@lasersbee Год назад
Very Well explained... Easy to understand. I have a question on a Mini Slit compressor Pump Motor "How to Check" ? like this Video
@izzybell11
@izzybell11 2 года назад
Interesting topic. Well presented and explained. Great job JMT.
@jollyscaria1922
@jollyscaria1922 8 месяцев назад
Vrey good welcome shering gues tjankyou my berthers dc motr restance dc fan moter series conted some unit ficing very good thankyou
@complex_variation
@complex_variation 8 месяцев назад
Hello: I have a GE AHTR12 that I'm repairing I just noticed something odd in my case that I would like to point out, I have the following readings from the main PCB to the motor: RD Vm = 317 V BU FG= 4.9V YE Vsp= 0V WH Vcc= 14.9V BK GND The "legend" or symbols of each wire I got it from the my motor's sticker. So the odd thing here is, that I do get a voltage on BU FG, but not on Vsp. Again I measure it coming from the PCB. Anyways I'm wiring it the same way how it came from the manufacturer, so I just wanted to point it out if someone finds this useful.
@nicolerennie
@nicolerennie 2 года назад
very useful & helpful video, thank you for sharing! ⚡️✨
@notashamed7563
@notashamed7563 Год назад
Thanks!
@fabioalves-qf8ms
@fabioalves-qf8ms 10 месяцев назад
Hello, 👋. I am sorry, if I received any voltage from blue ( signal rpm) ? I have voltage, but in the blue in have nothing. And my motor is not running…. But i have voltage in feedback….. and I have to 310v and 15vdc on wh…..
@narayanaya5519
@narayanaya5519 Год назад
Hi friend could you please let me know the details about what is the purpose voltage between GND AND VCC , what is the purpose voltage GND AND VSP , and finally Fg means what could please send reply .I am ur subscriber 🙏
@sv6k0a39
@sv6k0a39 2 года назад
Did the manufacturer provide you with info on the resistance and voltage values?
@mattalexander8919
@mattalexander8919 2 года назад
In heating it’s a condenser fan motor too.
@stephwaylonwells3218
@stephwaylonwells3218 2 года назад
👍
@daveswoodworks2602
@daveswoodworks2602 5 месяцев назад
Very well explained, This helped me alot!
@JumpermanTech
@JumpermanTech 5 месяцев назад
I'm glad this video helped. Thank you very much! Stay tuned for new videos every week🔧⚡️
@cedn5658
@cedn5658 2 года назад
3:07
@MC...
@MC... 2 года назад
FA 🤘🔥🔥🔥🔥
@thesilentonevictor
@thesilentonevictor 2 года назад
Great video tech
@marcochavez7007
@marcochavez7007 Год назад
Do you check the board the same way ?
Далее
Сколько стоит ПП?
00:57
Просмотров 173 тыс.
Лиса🦊 УЖЕ НА ВСЕХ ПЛОЩАДКАХ!
00:24
I HATE Mitsubishi MiniSplits
15:41
Просмотров 133 тыс.
Brushless Motor - How they work BLDC ESC PWM
16:12
Просмотров 4,6 млн
HOW TO TEST DAIKIN FAN MOTOR.
6:34
Просмотров 20 тыс.