HVACR Training: How To Wire RANCO Electronic Temperature Control (RANCO ETC111000-000 Wiring) 

Jumper man Tech
Подписаться 102 тыс.
Просмотров 3,8 тыс.
50% 1

Опубликовано:

 

26 окт 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 15   
@zekenzy6486
@zekenzy6486 9 месяцев назад
Great Video. Thank you for sharing. I'm waiting for watch next video. Have a nice week.
@stevencossaboon3237
@stevencossaboon3237 9 месяцев назад
Nice work Jumper man. Thank you
@brandoncorrea511
@brandoncorrea511 9 месяцев назад
Alright can’t wait for the troubleshooting
@sherwinalvarez7365
@sherwinalvarez7365 9 месяцев назад
Or... Or adding a Grasslin 115V or DTAV40.
@billyhorton5779
@billyhorton5779 9 месяцев назад
Good stuff, thanks JMT!
@kennethlobo4420
@kennethlobo4420 9 месяцев назад
Thank U jumper man Tech
@nicolerennie
@nicolerennie 9 месяцев назад
love these training vids!
@briancarlisi2224
@briancarlisi2224 9 месяцев назад
One question is on your last example wired for 120v you showed the orange jumper from 120 to the C terminal with the yellow from the NC terminal to the solenoid. I’m confused about the red coming from C (where the orange jumper terminates) but where does the red terminate? The diagram didn’t show a second wire coming from C. What am I not understanding? Thanks for taking the time to explain.
@barrybroderick5103
@barrybroderick5103 9 месяцев назад
Was wondering the same , I don’t think there should of been a second wire coming out of the c terminal in both examples 🤷🏻‍♂️ as per the diagram
@harrydickson4575
@harrydickson4575 9 месяцев назад
Awesome 👍👍👍
@Herewegoagain797
@Herewegoagain797 9 месяцев назад
Looks like according to his schematic, he ran the N back to the Common on the bottom contact instead of back to the Neutral side of the load. Could use some clarification on that cause it looks like he would just be shorting the contacts by sending N back to its hot side.
@artdacunha11
@artdacunha11 7 месяцев назад
HVAC student here from Canada. How would you connect this to a defrost timer? ..or is it odd to wire it up with a defrost timer?
@youtderek
@youtderek 6 месяцев назад
This would be wired on the NC portion of the defrost timer. So when the defrost timer is not in a defrost cycle, it is supplying voltage to this thermostat. When the box temp rises above the thermostat setpoint it will open the solenoid and allow refrigerant from the receiver to feed the evaporator. Once the evaporator picks up enough heat, the liquid refrigerant is boiled to a gas and the low side pressure (back pressure rises). On a separate circuit is the low pressure switch, once the low side pressure exceeds the setpoint of the low pressure switch, it activates the compressor and the refrigeration cycle begins. Once the box temp reaches below the setpoint of the thermostat, the thermostat no longer energizes the solenoid and refrigerant is no longer fed to the evaporator. The low pressure switch continues to energize the compressor until it reaches its low pressure setpoint (usually around 5psi) and the refrigerant is pumped into the receiver (aka pumpdown).
@artdacunha11
@artdacunha11 6 месяцев назад
thanks for the reply, I appreciate it!
@ILoveKittys78
@ILoveKittys78 9 месяцев назад
😻💚💜💚
Далее
ŠKODA не перестает удивлять
00:48
Просмотров 642 тыс.
DEMONS ARE ATTACKING BRAWL STARS!!!
09:08
Просмотров 10 млн
How to Read Furnace Wiring Diagram
30:56
Просмотров 248 тыс.
Ranco etc111000 tstat
8:22
Просмотров 13 тыс.
Thermostat Wiring Explained!
10:35
Просмотров 992 тыс.
Basic Thermostat Wiring Diagram Explained
13:11
Просмотров 49 тыс.
Basic walk in box control wiring
12:30
Просмотров 59 тыс.
How To Read Wiring Diagrams For HVAC
17:08
Просмотров 51 тыс.
ŠKODA не перестает удивлять
00:48
Просмотров 642 тыс.