Important tests on Transformers Tamil 

ELECTRICAL VATHIYAR
Подписаться 6 тыс.
Просмотров 15 тыс.
50% 1

IR test done
PI test explained Tamil

Опубликовано:

 

8 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 29   
@Gulsejkm
@Gulsejkm 3 месяца назад
Very useful sir... thanks
@venkateshprabhu8699
@venkateshprabhu8699 2 года назад
well explained practicaly sir .thank you..
@sugumars8168
@sugumars8168 2 года назад
Very use full
@rameshparamasivan6997
@rameshparamasivan6997 2 года назад
Super 👌👌
@ashirah-2019
@ashirah-2019 11 месяцев назад
Useful this video
@30mAkills
@30mAkills Год назад
Rare video in Tamil on IR testing of DT transformers. Good point = No need of jumpering terminals.
@arasurathin1469
@arasurathin1469 Год назад
Stability test podunga bro
@mageshmageshmagi1550
@mageshmageshmagi1550 3 месяца назад
After test discharge everything
@sujisulagam3092
@sujisulagam3092 2 года назад
Nice👏
@electricalvathiyar1753
@electricalvathiyar1753 2 года назад
Thanks
@harisuthan6150
@harisuthan6150 2 года назад
Nice
@electricalvathiyar1753
@electricalvathiyar1753 2 года назад
Thanks
@hkvasan7091
@hkvasan7091 Месяц назад
Why Apply voltage Value 5kv
@palanipps
@palanipps Год назад
while primary testing time secondary should be shorted & earthed & secondary IR doing time primary should be earthed..those details not informed sir..just for information.
@electricalvathiyar1753
@electricalvathiyar1753 Год назад
Agreed for safety purpose
@palanipps
@palanipps Год назад
@@electricalvathiyar1753 earthed in other end not for Saftey else values will come in Mega ohms instead as Giga ohms..if you have doubt you can trail IR values with & without opposite end earthed.
@chandrus3803
@chandrus3803 3 года назад
How to check transformer winding resistance test.....
@electricalvathiyar1753
@electricalvathiyar1753 3 года назад
It will be measured with Transformer ohm meter. By testing with multimeter you will get continuity (only beep) in secondary LV sides and a small ohm value on primary HV side but no beep.
@electricalvathiyar1753
@electricalvathiyar1753 3 года назад
megger.com/10-a-transformer-ohmmeter-mto210 The Transformer Ohmmeter is extremely useful when testing the windings and contact resistance of tap-changers with “make-before-break” contacts and voltage regulators. This action will check for pitted or misaligned contacts as the instrument will give an indication if either condition occurs.
@chandrus3803
@chandrus3803 3 года назад
Thanks sir.can you upload one video about how to check transformer winding resistance test
@electricalvathiyar1753
@electricalvathiyar1753 3 года назад
Ok
@hollywoodtimes4002
@hollywoodtimes4002 2 года назад
Sir leada secondary side la neutral en kodukurainka phase layea kodukalamaa
@electricalvathiyar1753
@electricalvathiyar1753 2 года назад
Star connectionla neutral common point. Phase to phasem kudukkalm.
@hollywoodtimes4002
@hollywoodtimes4002 2 года назад
@@electricalvathiyar1753 nandri sir I also have another doubt earth value withgrid yeavalavu irukkanum sir without grid yeavalavu irukkanum sir withgrid and without grid details sollunga sir
@electricalvathiyar1753
@electricalvathiyar1753 2 года назад
Less than 1 Ohm
@manothi9240
@manothi9240 2 года назад
Ithu ena test.ratio testah
@vinilm1844
@vinilm1844 Год назад
Kanyakumari slang 🥰🥰🥰
@manojl3446
@manojl3446 Год назад
11kv why 5kv used Miter
@Gulsejkm
@Gulsejkm 3 месяца назад
For 11 kv transformer, cable, VCB, OCB We have to give only 5000 V DC is enough. For LT 500 V DC is enough to find the IR Value