Inside a bottle air vent and plumbing ramble. (No electronics whatsoever.) 

bigclivedotcom
Подписаться 1,1 млн
Просмотров 166 тыс.
50% 1

This video is mainly about an automatic air vent that allows air to escape from a closed loop water circulation system. It kinda went of at a tangent initially with some JG Speedfit fittings and the way they work.
Being used to working with copper pipe and compression fittings I'm having to muster up the courage to use these simpler push-together fittings.
Here's a video where Ultimate-Handyman tests a push on fitting to failure.
• Push fit fitting press...
If you enjoy these videos you can help support the channel with a dollar for coffee, cookies and random gadgets for disassembly at:-
www.bigclive.co...
This also keeps the channel independent of RU-vid's advertising algorithms allowing it to be a bit more dangerous and naughty.

Опубликовано:

 

1 окт 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 1,1 тыс.   
@ultimatehandyman
@ultimatehandyman 5 лет назад
Thanks for sending viewers to my pressure testing video of the push fit fitting 😉 I installed a kitchen tap for my sister a few weeks back, and noticed that the “plumbers” that installed it had used plastic pipe- with NO INSERTS! I was shocked, so decided to test out plastic pipe on the pressure test bucket, without the inserts. I pumped the bucket up to the maximum (over 50 BAR) and not much happened. I expected the fitting to pop right off the pipe, but it didn’t! Obviously the test was done with cold water and I am in no way suggesting that inserts are not used! I would imagine that if hot water was used, you could get very wet- very quickly due to the expansion and contraction. You have a great channel and some good subscribers, congratulations! Greetings from Darwen, Lancashire.
@bigclivedotcom
@bigclivedotcom 5 лет назад
I think most of the issues may be people forgetting to pop the inserts in or ramming rough ends through the O-rings and scratching them. I'm wondering how adversely the sudden hammer from washing machine solenoid valves will affect the joints.
@ultimatehandyman
@ultimatehandyman 5 лет назад
@@bigclivedotcom I would imagine that would have a huge effect on the fitting, especially if the house had high water pressure to begin with. It might not fail immediately, but after a few hundred wash cycles there is a good chance that the fitting will let go of the pipe. Thanks for the reply 😉
@mikefochtman7164
@mikefochtman7164 4 года назад
@@bigclivedotcom Here in the 'states' we use PEX with various fittings (I like 'SharkBite' which is a brand name that doesn't use inserts at all). I've always told myself that the 'give' in PEX piping probably absorbs the hammer shock better than copper. But maybe I'm just wishful thinking. My washing machine doesn't have any hammer arresters.
@keirstitt8277
@keirstitt8277 Год назад
So long as it's held under good pressure I'm not sure it would be that bad with hot either - but not recommended. I had a leak in my shower which turned out to be a missing insert on the pipe from the valve to the outlet - obviously this bit of pipe is basically at atmospheric every time I turn the shower off. The cowboy who installed that shower has created a lot of problems over the years for me 🤦
@crackedemerald4930
@crackedemerald4930 5 лет назад
Electricity, Hidraulics, same thing, both involve angry magical beings, angry pixies and unyielding nymphs respectively
@teamdrummond6915
@teamdrummond6915 Год назад
Good one!
@twocvbloke
@twocvbloke 5 лет назад
That vent kind of reminds me in a way of a carburettor bowl, but working to let the air out rather than the fuel in...
@OZCamperTravels
@OZCamperTravels 5 лет назад
...or a toilet cistern backwards?
@wobblysauce
@wobblysauce 5 лет назад
both use the same principle.
@stevecummins324
@stevecummins324 3 года назад
Very like a bucket steam condensate trap still in use from early 1800s. Except they keep gas in and let liquid out. Just different lever arrangement for float and valve
@charlesburow8120
@charlesburow8120 3 года назад
Just thinking the same thing.
@crimsonhalo13
@crimsonhalo13 5 лет назад
♫ Zu klein, Zu groß, Every size will fit this hose, Ram it in, Tighten up, Turn it out, Bratwurst im dein sauerkraut!♫ *sets fire to pyrotechnic angel wings* ... see? Rammstein songs are half plumbing.
@WineScrounger
@WineScrounger 5 лет назад
Crimson Halo 🤣
@boblewis5558
@boblewis5558 3 года назад
And there I thought Rammstein music was just for the USAF airbase!?
@juliogonzo2718
@juliogonzo2718 5 лет назад
I used to live in an apartment with underground parking. There was a hose bib in my stall, I washed my car a few times before I realized the water changed to hot in the winter. Oopse :)
@throttlebottle5906
@throttlebottle5906 5 лет назад
lmao, now that is funny....
@-EC002-
@-EC002- 5 лет назад
Under floor heating generally uses 16mm Pex-Al-Pex piping.Very reliable in my experience.
@jmonsted
@jmonsted 5 лет назад
I love installing PEX, but the real question is how long it takes before it degrades and falls apart. Hopefully never, but...
@peterfitzpatrick7032
@peterfitzpatrick7032 5 лет назад
@@jmonsted pex-al-pex has an inner core of aluminium coated inside & outside with pex material, it also comes pre-insulated & when bent it maintains the angle of bend unlike plain pex... 😎👍☘
@jmonsted
@jmonsted 5 лет назад
@@peterfitzpatrick7032 Yep, i used it for a couple of runs where i needed insulation (mostly the home runs from the distribution manifold back to the boiler). It's even nicer to work with, but at a quite significant cost. PEX alone is still a god-send compared to metal piping (especially the cast iron i replaced).
@rickhunt3183
@rickhunt3183 5 лет назад
Pex pipe tubing is the future. The key is making sure you have the proper connections or there will be leaks a few years later. The install is about 10 times faster than pvc. I haven't had any problems and don't expect any because I won't use cheaper connections and I always use tools that are made for commercial applications. When possible.
@howlingwolven
@howlingwolven 5 лет назад
@@jmonsted This is why Poly-B was banned.
@Brusselpicker
@Brusselpicker 5 лет назад
Worked in the business for years, maintaining many MOD sites, copper all the way. In my experience, plastic compression fitting will give in at random times, as an example of 500 new accommodation spaces built , there were at least 100 failures of push fits within the first year, the rate of failure of soldered copper? 0, none. Plastic is a cheap, easy and less skilful way of piping up, once you use a push fit and remove the o ring from the copper it's useless and will inevitably fail.
@Brusselpicker
@Brusselpicker 5 лет назад
Just to add, the push fittings were always used by outside contractors to keep their bids cheap as they were not required to maintain the new buildings, they don't care about the long term. Us maintenance guys always used copper knowing we wouldn't need to "re re-fix" a repair. We spent literally thousands of man hours "maintaining" these new systems to get them to work properly. If I had any choice I would always start with soldered copper, followed by compression fit copper, any poly pipe with push fit would be the last choice in my own personal property.
@Brusselpicker
@Brusselpicker 5 лет назад
Ferrules are mandatory when installing poly pipe on any MOD site, just sayin. You can avoid pinholes by cleaning flux off and actually bothering to flush pipework out only no one seems to want to pay for that so you get pinholes. Only outlets that require flushing are "little use" outlets and those need to be flushed whether they are copper or not according to l8 regulations. Oh and water fountains can't be used anyway, l8 legislation again. Oh and the 70s you say, how modern, part of my work includes a 12th century priory, the most modern buildings, apart from refurbishment of new build (12 accommodation blocks built by the lowest bidder that started cracking up within a year) were the sixties, with quite a large number dating back to WW2 or further, we never had or have as much trouble with the copper as with poly, just never have. The poly though lol, one split joint caused £100,000 worth of damage and resulted in three floors of the building that was 18 months old being stripped back to bare frame and being rebuilt.
@daveayerstdavies
@daveayerstdavies 5 лет назад
Properly installed good quality copper pipe and fittings will last indefinitely. O-rings are not forever and will eventually fail in 20-60 years. Contractors love plastic, not because it's better or cheaper but because it takes a fraction of the time to install and requires far less skill.
@oguzhan001
@oguzhan001 5 лет назад
Totally agree. With a borrowed pvc pipe heater, I was able to install a new piping system that stretched from the main source & to the my house. Tho, I got professional help for rest of piping work lol.
@volvo09
@volvo09 5 лет назад
Faster and easier wins. But for my stuff I still solder. I hope I'm wrong, but if o rings fail in vehicles and devices after years of heat cycles, I can imagine the same thing happening here in 20 - 40 years. The crimp copper fittings are even being used in AC installs. I'll stick to solder, and require it if I get work done that I don't DIY. My brother got a new boiler installed in his house and they used about 50 to 60 of those viega copper crimp fittings, sorta defeats the purpose of copper to me.
@bgregg55
@bgregg55 5 лет назад
Well...copper freezes & splits. copper sourced from china often has contamination which corrodes & springs leaks. copper is expensive. we never use copper anymore.
@johnpossum556
@johnpossum556 5 лет назад
Around here copper is code for all commercial and rental properties. IE: The government says its better.
@Conservator.
@Conservator. 5 лет назад
volvo09 Lol I read AC as Alternating Current in stead of air conditioning.
@PhilipBallGarry
@PhilipBallGarry 3 года назад
I first used Speedfit (or similar) plastic pipe and fittings about 10 years ago. A neighbour came round to help me move a radiator in the bedroom onto an adjacent wall. He recommended plastic but I was a bit dubious - especially as the floorboards were going back down afterwards, then a new carpet and I was worried about how secure these new kids on the block would be in the long term. It certainly made the job easier though and we simply re-routed the existing pipework by drilling a 15mm hole in each joist and pushed the plastic pipe through. I even used plastic fittings for the final 90 degree elbows, but for the vertical feeds I did use copper. Or rather, I cut the existing copper pipe just beyond floor level. The ridiculously simple "push on" fittings couldn't be any good I thought - as I usually used solder ring fittings. But, the system was refilled, bled and there were no problems at all. I save a few hours overall. The only thing to remember is that you don't use plastic pipe or fittings within the first (or last) 1 metre from the boiler.
@sziltner
@sziltner 5 лет назад
PEX, the absolute best! It will last longer than we will! No more worry about copper degrading and pin hole leaks. What a refreshing video change. Hopefully you have more plumbing projects. Electrical and plumbing, is there anything better? Well, maybe eating!
@a.h.2276
@a.h.2276 5 лет назад
Agreed but please no eating. We already have too many mukbang videos on this shit hole of a platform.
@khaitomretro
@khaitomretro 5 лет назад
It'll be the rodents eating through the pipes you'll need to worry about.
@garyphillips7993
@garyphillips7993 5 лет назад
The pipe may outlast us and ultimately add to the plastic waste we're drowning in, but the rubber seals inside won't. They degrade and have a lifespan, depending on manufacturer, up to 20 years, many much less. It was reported many years ago that the pin holes appearing in copper pipes into houses was caused by a combination of impurities in the copper reacting when the cold water pipe was used as the main earth for the house. I know from bitter experience living in a 50's built house 😠
@wobblysauce
@wobblysauce 5 лет назад
+
@ShotgunpleaseNOW
@ShotgunpleaseNOW 5 лет назад
Yeah Pex is alright but copper will last a lot longer at least in Australia where we don’t have frost temperatures, besides pex lets diy dickheads to do their own plumbing then wonder why their house is flooding
@karthik_raju
@karthik_raju 3 года назад
10:36 in case of a clogged up valve one could take the top nipple screw cap off and push down on the valve by sticking a thin screwdriver through the bleeder hole. That way you have a quick fix with out having to depressurize the whole system
@bodinski100
@bodinski100 5 лет назад
use plastic everyday, maybe 2 leaks in last 10 years...make sure pipe is clipped to joists etc well
@rogertycholiz2218
@rogertycholiz2218 3 года назад
Bod Cole - Installed ten compression fitting shutoffs on copper pipe for 40 years with no leaks.
@davet6745
@davet6745 5 лет назад
PEX means polyethylene cross-linked
@veleriphon
@veleriphon 2 года назад
And it's fantastic.
@RIXRADvidz
@RIXRADvidz 5 лет назад
Expanding Horizons!! non-electrical tear-downs. the mind boggles, the opportunities myriad, a whole new Universe is opening up. it was the siphon pump on the bubble blower wasn't it. yeah, me too.
@joedugas9462
@joedugas9462 5 лет назад
Plastic pipe is cross-linked poly-ethylene. Proper ways of connecting it is using "crimp" style fittings or expanding ring fittings (Wirsbo) or "quick and easy" method. Push fit fittings such as "shark-bite" or O-ring fittings should be considered temporary methods. PEX piping will out-last copper if using proper joining methods. Copper is not better.
@ChurchOfTheHolyMho
@ChurchOfTheHolyMho 5 лет назад
After 2 different plumbers used PEX (and one used a SharkBite connector) - I became a fan. Note: My parents had some PEX installed, and theirs had an unpleasant taste. My PEX does not. Seems to be easier to use than PVC/CPVC.
@grrarg9319
@grrarg9319 5 лет назад
Unless you're talking about its ability to kill off MRSA, in which case COPPER FTW!! :D
@ethanpowell8163
@ethanpowell8163 5 лет назад
It will also lower water pressure, due to friction in the joints, due to the ID of the joint being significantly small... I feel bad for the lady we might have to do a repipe for. Her water pressure is so low the valve on her kitchen faucet doesn't want to stay open, due to it using pressure to stay open.
@CrimeVid
@CrimeVid 5 лет назад
Joe Dugas Hollyhocks ! these fittings last extremely well, just use the mf’s own fittings and you’re good, I have never seen “crimp”style fittings in the UK.
@ursodermatt8809
@ursodermatt8809 5 лет назад
those "plasticky plumbing things" have only been around for a limited time. so you cannot make a statement that they are outlasting copper.
@ColtaineCrows
@ColtaineCrows 5 лет назад
In Norway we use "pipe in pipe" systems now. Basically a corrugated pipe is installed with a plastic water line inside it going back to a main water cabinet. Essentially the plumbing industry is doing the same thing as the electricians here. So if you have a leak it'll leak back to the water cabinet which should be installed in a water safe room and spill out on the floor there instead of all over your house. That is if your leak is in the walls. Anything on the outside is still liable to cause damage, but that's why you're also required to install water sensors and an electric shut off valve system under the kitchen furniture etc. Just like you're required to install a temperature sensor shut off thingy over the stove (Which sucks btw, never work like they should and are pointless for induction stove tops IMO!) www.johnguest.com/speedfit/product/pipe/pipe-in-pipe/ It's a nice system IMO. It looks like the pipe you're showing here is one half of the John Guest pipe-in-pipe system. EDIT: Basically it means you have one run of water to the kitchen faucet, one run to the dishwasher, one run to the toilet, one run to the shower and so on. So it does require some more pipes to be installed, but it's really good for preventing water damage.
@edcooper2396
@edcooper2396 5 лет назад
How do you ensure you always have a clear and continuous fall of the pipes to the water cabinet, often they have to be run horizontally over quite long distances. Most homes in the UK have central heating with radiators, there's no way you're going to run a flow and return to every radiator?
@sigurdhovden4961
@sigurdhovden4961 5 лет назад
@@edcooper2396 the outer pipe is sealed at the end so it will fill until the water returns to the cabinet and heating and cooling is sadly exempt from the requirement of the replacement and "water damage safe" rules
@HighestRank
@HighestRank 5 лет назад
Sounds for a great place to get a drink- for roaches.
@DoRC
@DoRC 5 лет назад
The technical term for that olive is a ferrule.
@TheChipmunk2008
@TheChipmunk2008 5 лет назад
No, olive is the correct technical term on this side of the atlantic.
@DoRC
@DoRC 5 лет назад
@@TheChipmunk2008 oh. I've heard ppl in the states call it an olive as well. Didn't know it was the official term there.
@TheChipmunk2008
@TheChipmunk2008 5 лет назад
@@DoRC indeed, two countries separated by a common language is often scarily true. It's even worse with many other words
@davidgreen5099
@davidgreen5099 5 лет назад
@@TheChipmunk2008 olive
@BedsitBob
@BedsitBob 4 года назад
"playing with something that can flood your house out." Stop bragging.
@moa3821
@moa3821 5 лет назад
but i like the schematics.its the most valuable thing your channel offers, i look forward to learning from them
@philliplopez8745
@philliplopez8745 5 лет назад
The popular American brand is " shark bite " expensive but worth while for repair work or joining dissimilar materials .
@carpespasm
@carpespasm 5 лет назад
And they're not technically rated for air pressure, but I've seen them successfully hold a 190PSI/13bar for years just dandy.
@HighestRank
@HighestRank 5 лет назад
Sharkbite* worthwhile *
@philliplopez8745
@philliplopez8745 5 лет назад
@@HighestRank auto correct
@koffibanan3099
@koffibanan3099 5 лет назад
If you can, you should take a look at the spirotech deaerator that are getting very common here in Belgium. They seem a bit more advanced and mysterious. I also watch the ultimate handyman, like his accent! :)
@ultimatehandyman
@ultimatehandyman 5 лет назад
You either love, or hate the accent- I have plenty of haters! Thanks for watching the videos and commenting ;-)
@koffibanan3099
@koffibanan3099 5 лет назад
@@ultimatehandyman Haha! The accent is naturally not the only reason I watch your informative, honest and well put together videos :) I do it to impress friend and enemy with 'my' knowledge about tools and DIY'ing :D Finished quite a few projects that have benefitted greatly from your advice. So thanks a lot for all your effort!!
@ultimatehandyman
@ultimatehandyman 5 лет назад
I'm glad that the videos help ;-) When I get a comment from someone like you, it always reassures me that there are good people on RU-vid 👍 Thanks again for watching, and commenting 😉
@Brian-cr6rb
@Brian-cr6rb 5 лет назад
I love those things!
@treed5953
@treed5953 5 лет назад
@@ultimatehandyman That tears it, now I'm intrigued about the accent
@markiangooley
@markiangooley 5 лет назад
Most of the plastic pipe work I’ve done involved adhesives. Hadn’t seen that type of fitting before. I don’t have all that much experience. Obviously it was all PVC pipe; probably I’d use PEX for new construction. I did have a pinhole leak in a copper pipe here (1970s work). Condominium: my monthly fees covered the plumber’s work.
@fillg
@fillg 5 лет назад
Thanks for the air vent explanation. I've always wondered how they could let the air out but not spray water constantly.
@isoguy.
@isoguy. 5 лет назад
Glad to see you opted for the GF kitemarked version. Beware of chinese clones, short mouldings, poor o rings and doggy steel clips that rust tend to make them fail often. My Dad did his bathroom using cheap chinese clones, they failed after 3 months, and completely flooded his house overnight. He had to rip up all the newly laid floors upstairs, completely redecorate the whole house while our family moved out for 6 weeks. The insurance refused to pay out as the fittings were not up to code and were not fitted by a professional plumber. For the sake of using kitemarked parts he paid out £1000s and then had to have all the piping and fittings replaced. Beware of Chinese clones.
@bigclivedotcom
@bigclivedotcom 5 лет назад
I'd never use a cheap copy in a situation like this.
@wimwiddershins
@wimwiddershins 5 лет назад
I imagine the clever spring pivot thing allows the silicon stopper to find its own location on the outlet port. If it was a rigid hinge there's a chance the two would fail to align and water could ooze through. These things have a lot of thought & experience put into their design resulting in quite elegant solutions.
@bigclivedotcom
@bigclivedotcom 5 лет назад
That's probably it.
@CoolerQ
@CoolerQ 5 лет назад
@@bigclivedotcom My guess is that the spring mounting allows a vacuum in the plumbing to suck in air. Not sure why they'd want that.
@manolisgledsodakis873
@manolisgledsodakis873 5 лет назад
The stopper is silicone not silicon.
@agvulpine
@agvulpine 5 лет назад
@@CoolerQ ​ I estimate that the pivot type used exerts a stronger spring leverage against the sillycon seal. A fulcrum at the other end could allow weak forces against the lever to prove Archimedes was right.
@AngDavies
@AngDavies 5 лет назад
@@CoolerQ These things are sometimes referred to as "pressure/vaccuum relief valves" so you're probably spot on, as the water empties out of the tank/ it cools something needs to replace what's gone out or the pressure is going to drop, and despite being much lower than the maximum expected positive pressure, tanks are in general gonna be much worse at withstanding negative pressure than positive ( positive pressure is stabilising, it wants to round out the tank. Negative pressure is destabilising - it's going to tend to amplify any asymmetry and buckle it inwards, causing additional strain on that area and leading to a sort of cascading failure). funnilly enough the negative pressure need not be limited to a vaccum - in the worse case the pressure can drop substantially below vaccuum pressure. Water is not a gas, it sticks to things and can "pull" as well as "push", in low pressure it will boil and reduce that somewhat, but not necessarily enough to keep the pressure above 0. This would however probably only apply to tanks on an upper floor, and would be a bit contrived, but even vaccuum could be dangerous enough. The negative pressure effect can be seen nicely with very tall trees, like redwoods - the tubes that carry the water are very smooth and there's nothing for the water to nucleate off to start boiling and thus the water can be put under the ~negative ten atmospheres of pressure required to pull water all the way to the top.
@alidavemason4417
@alidavemason4417 2 года назад
Great video as always Clive. Did you know that on the plastic pipe fitting, if you continue to unscrew it past the the resistance point the whole thing disassembles. This makes it easier to remove the pipe insert instead of using pliers. Cheers Dave
@PatrickLeeUS
@PatrickLeeUS 5 лет назад
Have faith in the speed fit, but what I didn't tell you when I recommended it earlier is that you absolutely must install a water hammer arrestor in the system. Otherwise the water hammer over the years will have a tendency to overly stress the o rings causing failure.
@bigclivedotcom
@bigclivedotcom 5 лет назад
I was wondering what effect water hammer would have. Especially with a washing machine that uses solenoid valves.
@IncertusetNescio
@IncertusetNescio 5 лет назад
@@bigclivedotcom Machinery like that makes me wonder why the heck they don't have a built-in water hammer arrestor/preventing device built in knowing full well that it's a device that does it. Doubly so knowing how cost optimized some of the other parts in there are. Or heck, just use a slower closing valve. Maybe use a pressure bypass valve for pressure spikes when the valve closes that lets enough water through into the machine to clip the spike down below plumbing-stressing levels.
@l3p3
@l3p3 5 лет назад
I did not know that problem exists. I am used to open and close faucets in a rapid manner to save time. If you work with power transistors, a quick switch time is a good thing. But the pipework of where I live is metal, I think.
@michaelfisher9671
@michaelfisher9671 5 лет назад
Isn’t water hammer caused at least in part by the lack of give in water and copper? If so and if as BC says this piping has some ability to stretch (which is why it can survive freezing) then it may not hammer.
@PatrickLeeUS
@PatrickLeeUS 5 лет назад
@@michaelfisher9671 unfortunately it still hammers, albeit to a lesser extent. However, it still has enough force to blow an o ring.
@christastic100
@christastic100 5 лет назад
Really interesting to see inside the auto air vent . Fitted them but never tried to open it up. Believe the insert without external o rings are Used when plastic is used on brass/copper compression fittings with an olive . Used lots of John Guest pipe and fittings and found it good. Nice to use copper when on show though.
@EitriBrokkr
@EitriBrokkr 5 лет назад
I have never seen a rubber seal last more than 25 years without developing a slight leak, on anything ever. Just saying
@brendanrandle
@brendanrandle 5 лет назад
the o-rings around the base of the injectors in my car built in 1984 are still holding up just fine, pretty sure they've seen more abuse than the ones in this video ever will
@EitriBrokkr
@EitriBrokkr 5 лет назад
@Dave Micolichek valve cover gaskets develop leaks, oil pan gaskets develop leaks, and if you read the fine print, most of today's "quick" plumbing products, like every pex product I've ever seen, says right on the package, rated for 25 years
@EitriBrokkr
@EitriBrokkr 5 лет назад
@@brendanrandle first off, your intake is usually under vacuum so you wouldn't know even if they were, secondly there is zero pressure there, if anything considering the vacuum, it's negative pressure
@brendanrandle
@brendanrandle 5 лет назад
​@@EitriBrokkrthe top o-rings don't leak either and they're the only thing between 40-45psi(gauge) fuel and atmospheric pressure
@brendanrandle
@brendanrandle 5 лет назад
may not be rubber though
@hiredgun7186
@hiredgun7186 5 лет назад
we use a system like this , french made, transair piping for compressed air , its extruded aluminum and has a WP of 236 psi but tested to twice that
@MichaelOfRohan
@MichaelOfRohan 2 года назад
Hey thats pretty good. Id imagine oilers really work wall across those aluminum lines
@SebBrosig
@SebBrosig 5 лет назад
we replaced lots of plastic with copper... because of mice nibbling heating pipes.
@idiotstupid5904
@idiotstupid5904 5 лет назад
get a cat?
@HighestRank
@HighestRank 5 лет назад
idiot stupid cats can’t get behind cabinets and go everywhere, stupid idiot.
@lawsonjones2285
@lawsonjones2285 5 лет назад
It's also worth noting the air valve will allow air to be drawn into the system when it's being drained down and helps avoid vacuum locks
@thomasbland6428
@thomasbland6428 5 лет назад
lawson jones I’ve known installations that had a connection where they would connect a compressed air source to blow out any remaining liquid when draining the system. These were systems in cabins that were only used infrequently during the freezing season so were drained to prevent pipe bursts. Having a way to block air venting was important to force the air to exit where desired.
@millomweb
@millomweb 5 лет назад
@@thomasbland6428 When I decommissioned my old heating system, I sucked the water out with a wet n dry vacuum cleaner.
@RobertRoberts329
@RobertRoberts329 5 лет назад
We had tons of pinholes in our nearly 40 year old copper pipes. We had the entire place repiped in PEX (cross linked polyethylene) and the plumber who did the work used steel ripped connections. So far so good.
@DisabilityExams
@DisabilityExams 5 лет назад
Let us know in 40 years
@JGnLAU8OAWF6
@JGnLAU8OAWF6 5 лет назад
@@DisabilityExams it is a lot cheaper than copper
@robinturner2300
@robinturner2300 5 лет назад
I now use Hep2o PEX pipe and this has stainless steel inserts which grip inside the pipe and you can feel when they are seated if you twist them. Very reliable and much more frost proof than copper. Also easier to pull into place when replacing copper given the flexibility. They are known as shark bite fittings BTW not compression.
@HighestRank
@HighestRank 5 лет назад
There was a huge bout around requiring ID in order to vote locally due to a disenfranchised barrier island population... yet the naturally-gerrymandered minority couldn’t even be considered as indigenous Americans because of their skin color which proved the fact that their entire history was less than prehistoric, and ergo. tiger’s stripes belong on a tiger... which impasse was solved post haste when, to address copper theft fatalities, ID became simultaneously-required for both international flight and exchange recycled metals for cash. So the same water which made them unite also broke them apart.
@terry987654
@terry987654 5 лет назад
the thing with plastic pipes is what will it be like in 20 years will i have to replace it again? copper might be harder to install but at least it is tried and tested so you know it will out last us
@macemoneta
@macemoneta 5 лет назад
I had a plastic water main supply. It lasted 40 years, and then cracked under the front lawn. The plumber said they don't use that anymore, and replaced it with a single length (65 feet) of copper from a large diameter coil, pulling it through from the basement.
@simontay4851
@simontay4851 5 лет назад
Did you have water gushing out of the lawn.
@manolisgledsodakis873
@manolisgledsodakis873 5 лет назад
But the whole point is that Clive's copper pipe did NOT last - it was perforated. Here in Greece we have used plastic pipe since the time of the Romans. (Well, almost.)
@macemoneta
@macemoneta 5 лет назад
@@simontay4851 Yes, that was our clue. 😂
@macemoneta
@macemoneta 5 лет назад
@@manolisgledsodakis873 That was likely an improperly installed /damaged pipe. Copper also has the advantage of being antimicrobial, but it is more expensive than plastic.
@HeathenGeek
@HeathenGeek 5 лет назад
One of the nice things about plastic is it tastes nice when the mice eat it.
@pekkasaarinen2902
@pekkasaarinen2902 5 лет назад
You tasted it with the mice or after they've eaten it? If it's after then it could be just mouse pee giving the nice taste..
@crackedemerald4930
@crackedemerald4930 5 лет назад
I'm confused, do the _mice_ taste better or do they _like_ it better?
@bigclivedotcom
@bigclivedotcom 5 лет назад
You'd think the plastic drainage pipes would have been eaten by rats and mice if the plastic was desirable.
@Mark1024MAK
@Mark1024MAK 5 лет назад
bigclivedotcom - in my experience of mice and rats “eating” PVC, plastic and rubber cable, it’s generally to make a route past an obstruction, or because (in the case of mice) because they are “nesting”.
@HighestRank
@HighestRank 5 лет назад
They would either like the texture or some flavor which has soaked into the resin, and if both, could chew every bit of it just for the sheer hellofit. Tooth wear is minimal and coincidental, not a goal but an instinct which became necessarily habitual.
@Orxenhorf
@Orxenhorf 5 лет назад
Those things last until the o-ring inside degrades and wears out. So, you have no idea how long they'll last, because you have no idea if the manufacturer decided to cut expenses and use cheaper material, or they used good stuff that would last as long as the pipes.
@artyomhunter310
@artyomhunter310 5 лет назад
You can be sure that it was made with quality materials if it’s a WRATS approved product as they are the regulatory body that tests the product and if it meets their standards for a product to be sold with the WRATS label on it. Most manufacturers exprcssely recommend you use WRATS approved fittings on there product because of the guaranteed quality of the product. The O-rings will be fine for a long time if used on new plumbing but not as long on old plumbing. it will depend upon the amount of crap that running around the system but even in really dirty old systems the O-rings should outlast your emersion heater and hot water storage cylinders by many years. They should last longer on the cold water pipes as that water isn’t left to stagnate for long as it’s always used. They will also last longer in areas with softer water as a pose to in areas with hard water. The lime scale tends to build up around the O-rings and degrade them over time. The WRATS products do cost more than non approved products but your paying for the quality and longevity of the product. In my own opinion I think that the whole push fit plastic plumbing system is a better system than the copper one even the push fit copper systems. Even if the O-ring did perish or become unusable I do believe you can buy replacement O-rings instead of replacing the fitting.
@arcadeuk
@arcadeuk 5 лет назад
You get a 50 year warranty on the JG Speedfit fittings Clive is showing in this video.
@ferrumignis
@ferrumignis 5 лет назад
That's the main reason I don't really trust the plastic piping. The pipe itself seems very reliable, but o-ring seals invariably degrade over time.
@blower1
@blower1 5 лет назад
@@arcadeuk Lol - might as well be a 100,000 year warranty. Come 50 years time you think that company will still be around and not been bought out and changed name half a dozen times? A warranty much beyond 10 years on anything don't mean jack shit.
@arcadeuk
@arcadeuk 5 лет назад
@@blower1 Why so much unwarranted hostility to JG Speedfit? They (John Guest, a British company) have already been around for nearly 60 years. They've managed to avoid changing their name half a dozen times so far .......
@maesto
@maesto 5 лет назад
Here in germany pex is basically the new standard. Though in the non diy market usually its pressed fittings which are smaller and thought of more reliable. Works with Copper as well.
@blower1
@blower1 5 лет назад
Plastic pushfits are all well and good - but come back 20 to 30 years later, when the rubber seals have degraded and the plastic becomes hard. Then tell me they're great. I'm just waiting for the epidemic in about 10 years time when all these new build houses that are full of nothing but plastic pipe and pushfits, all starts to fail. All these pipes that are buried behind dot dab plasterboard and in ceiling voids - they'll have to rip the house to pieces to get at them. Why do i say this? - i have seen the results of this shit failing already, on a 12 year old new build. Galvanic corrosion is one mode of failure, from where a plastic pushfit is used to go from copper to plastic - the metal ring that grips the pipe starts to degrade on the copper side. Other failures are thin bore plastic central heating pipe that becomes very hard and the slightest movement of the radiator has resulted in leaks, in one instance the fitting came straight off and drained the entire central heating system down, flooding the bottom floor. Of course copper pipe is very hard - but it is installed in a way where it's not designed to move much. Plastic pipes on the other hand are installed in an incredibly hap hazard way, with forced bends and criss crossing all over the place along with on radiators that are designed to be hung forward for access when decorating. It's all great until the pipe turns hard and somewhat brittle from 1000's of heat cycles over many years.
@geoffpriestley7001
@geoffpriestley7001 5 лет назад
Dont use the push on fittings on chrome pipe it wont grip
@6581punk
@6581punk 5 лет назад
Copper is softer I guess.
@WineScrounger
@WineScrounger 5 лет назад
6581punk yes- chrome is really very hard, they use it for lining gun barrels. The teeth won’t touch it.
@Stigstigster
@Stigstigster 5 лет назад
Where you have to use them on chrome pipe you can carefully file/flake away the chrome plating and then use the pushfit as normal. I've had to do it a few times over the years and works just fine. Just don't be too aggressive with the file as you need to keep the pipe unmarked. The same goes for soldering that kind of pipe.
@HighestRank
@HighestRank 5 лет назад
Maybe this space is the place to apply steel wool.
@IncertusetNescio
@IncertusetNescio 5 лет назад
If you think about the plastic failing from a soda bottle perspective, that the plastic takes hundreds of PSI to fail is perfectly reasonable (certain types of plastic LOVE tension like concrete LOVES compression). Fairly thin walled soda bottles take tens of PSI no problem including drops, so several millimeters of plastic taking up to several hundred also makes perfect sense, even on the fittings. If anything metal is weaker in those situations unless you use super low diameter piping (with a to-scale thick wall) where hundreds/thousands of PSI is involved like diesel engine fuel injector lines. PEX according to a very quick search - Cross-linked Polyethylene tubing (PolyEthylene[cross*]) *where cross is frequently represented with an x, probably because it's super easy to do on a keyboard and + may not be usable in every computer system due to special character restrictions. I've seen it before in a tech term but forgot what term it was. With more time and a wikipedia section copied out - en.wikipedia.org/wiki/Cross-linked_polyethylene Cross-linked polyethylene, commonly abbreviated PEX, XPE or XLPE, is a form of polyethylene with cross-links. It is used predominantly in building services pipework systems, hydronic radiant heating and cooling systems, domestic water piping, and insulation for high tension (high voltage) electrical cables. It is also used for natural gas and offshore oil applications, chemical transportation, and transportation of sewage and slurries. PEX is an alternative to polyvinyl chloride (PVC), chlorinated polyvinyl chloride (CPVC) or copper tubing for use as residential water pipes.
@TheMechanicalPhilosopher
@TheMechanicalPhilosopher 5 лет назад
The last time I checked, it took around 150-160 psi to burst a 2 litre bottle.
@bondubasher
@bondubasher 5 лет назад
Had the very same in my house since around 2003 and haven't had an issue with it yet. I think if you observe the points you already made about protection of the O rings (no burrs etc) then it's fairly robust system. Great vids Clive, keep em coming...
@namespacetoosmall
@namespacetoosmall 5 лет назад
Yeah, the plastic will last, it will be around for 10,000 years. XD
@wannabetechnician7451
@wannabetechnician7451 5 лет назад
longer than the nuclear waste is radioactive
@EitriBrokkr
@EitriBrokkr 5 лет назад
It will be brittle, broken and cracked, and the orings will have dry rotted and split years before, but it will still be around...
5 лет назад
10,000 years is a long time for a water leak
@lacossanostra
@lacossanostra 5 лет назад
never heard of plastic eating microbes ?? clearly not so your fair mongering doesn't hold
@punker4Real
@punker4Real 5 лет назад
photo degrades
@RandomInternetDog
@RandomInternetDog 5 лет назад
We used air eliminators on pumps running liquids with high amounts of dissolved gas. Different design, basically just a metal ball that floats. Constant PITA.
@bodkin51
@bodkin51 5 лет назад
Used plastic for the first time on a bathroom refit. All was well until I fitted a shower pump, first time I've ever used the house insurance to clean up the flood. Went back to 22mm copper for the shower feed and all's well. Caution advised.
@DrCyberpunk1987
@DrCyberpunk1987 5 лет назад
I was told by a friend who was a builder that he'd worked on systems done in plastic, it's very important to provide a lot of support for the pipework.
@xxwookey
@xxwookey 2 года назад
I've been using plastic plumbing since 1994. Hep2O in the early days and mostly JG speedfit in recent times as it's more widely available. Not had any issues with failures. I do still like a bit of copper sometimes, e.g. for very high temperature stuff like solar thermal, but plastic is so much easier most of the time. It's funny to see someone in 2019 who's never tried it before.
@MrGoatflakes
@MrGoatflakes 5 лет назад
"no electronics whatsoever" nonsense, electricity is a sort of water, they taught me that at the technical college!
@pyromen321
@pyromen321 5 лет назад
I didn’t know magic pixies could swim
@HighestRank
@HighestRank 5 лет назад
pyromen321 angry* pixies can swim, though it’s those unyielding nymphs which are found in pipes.
@HighestRank
@HighestRank 5 лет назад
MrGoatflakes they said that water flows, is stored in tank circuits, both run in currents but nothing so similar as being a ‘sort of water’, unless you attended Hogwarts.
@mavos1211
@mavos1211 5 лет назад
Clive I have used speedfit for many years with no problems other than my own stupidity! ( forgetting to put the insert in ) I have test rig equipment that I have taken Apart and then re jigged different configurations many many times and it’s sealed up tight every time. I like copper but it’s hard to ignore and very convenient.
@HighestRank
@HighestRank 5 лет назад
mavos1211 copper hard to ignore, well that’s only if you’re running thieves’ blood in your veins.
@thomasharper9087
@thomasharper9087 5 лет назад
yes but plastic pipe connectors are much MUCH bigger compared to soldered copper joints
@gelu88
@gelu88 5 лет назад
The ones he's using is massive. I prefer the "sharkbite" brand ones which are quite a bit more compact. Expensive though.
@edcooper2396
@edcooper2396 5 лет назад
and a lot more restrictive with those inserts installed!
@simontay4851
@simontay4851 5 лет назад
And any copper off-cuts are fully recyclable. plastic pipe probably isn't. Hot water might soften/melt plastic pipe. Soldered copper looks nicer. Lots of advantages to copper.
@ComandanteJ
@ComandanteJ 5 лет назад
@@simontay4851 Almost all plastics are very easily recyclable. Piping plastics are not your "cheap chinese toy" variety, heat is not a problem, and if REALLY hot water is expected, there are plastic pipes that are engineered to resist temperatures well over 100 ºC . Soldered copper does looks nicer... but who cares? It's inside a freaking wall. The only advantages of copper are that it tends to be cheaper overall because good plastic joints are expensive, and space, copper is a lot more compact.
@donkmeister
@donkmeister 5 лет назад
@@simontay4851 On the hot water aspect, boiler installations require copper for the first metre away from the boiler for this very reason - who wants a melty-saggy pipe? Copper also requires fewer clips to avoid it sagging and straining against the fittings. Like you I prefer soldered end-feed copper, plastic O-ring based systems (I favour Hep2O if I must use one) are really quick and easy though, especially for amateurs. I don't think plastic is approved for domestic gas either - I know my gas main is plastic right up to the boundary line, then iron to the meter, then soldered copper from the meter to the appliances.
@dantuck5242
@dantuck5242 5 лет назад
Pex is polyethylene- cross linked. The barrier is for preventing oxygen permeation
@Richardincancale
@Richardincancale 5 лет назад
Known in Scotland as a ‘snifter’ valve. Same word for a wee dram...
@matthewmaddox8582
@matthewmaddox8582 3 года назад
The only problem with plastic pipe systems is mice....they can have a wee munch on you pipes and then your in trouble
@rimmersbryggeri
@rimmersbryggeri 5 лет назад
Your old pipe was cavitated beause of shoddy installation. When you don't deburr the ends properly that can happen because of turbulence caused by the burrs.
@ferrumignis
@ferrumignis 5 лет назад
Could you describe what kind shoddy installation can cause random pin holes through corrosion? How would cavitation occur in the middle of a run of pipe?
@rimmersbryggeri
@rimmersbryggeri 5 лет назад
@@ferrumignis There are videos here on youtube explaining it much better than I could.
@rimmersbryggeri
@rimmersbryggeri 5 лет назад
@@ferrumignis I think it's about the burrs creating condensation nuclei and when the bubbles burst they cause a sonic boom which create microscopic cavities in the pipe which are then eroded by the flow. Does that sound sufficiently like a 12yearold explaining something the heard about on lunch break?
@johnpossum556
@johnpossum556 5 лет назад
I'm surprised you aren't in favor of copper. You know how to solder. It's more solid, connectors are much cheaper than those plastic systems. The problem is those plastic systems have not been in place long enough to really know how they fare up in real world conditions. PEX, maybe is OK. For anything with pressure I want copper. Plastic is OK for drains & wastewater. I just had some brass waste pipes go. They lasted from 1958 until now. Mostly they wore thin than gave way when I was trying to snake the drain. For my money that 60 years is more than a lifetime. Most "lifetime" products sold to the consumer these days are only 15-20 years. Just some things to keep in mind.
@HighestRank
@HighestRank 5 лет назад
John Possum *then gave out
@victorrowley7494
@victorrowley7494 5 лет назад
Hi Clive, I was watching your video on bottle air vents, and a couple of things came to mind. Like you, I've always sworn by copper as compared to the new untested plastic pipes. But two winters ago, they had some prolonged periods of below freezing weather in wales. And as my son and his wife have a wooden holiday chalet in wales, when they made their first visit after the winter, and they turned the water back on, there were at least ten different bursts in the pipework. But when I went with them to do the repairs, we found that half of the chalet (I'm guessing it must have been an extension built on the original), was piped for both hot and cold water with plastic pipe of the type you were describing. And whereas the sections of copper in all other areas of the chalet have ruptured, there wasn't one leak, nor forced joint, nor split in any of the plastic system. So maybe, plastic is the way to go. And one more thing, if I'm not boring you; your pinholes in your copper pipe. A thought that struck me, was that I've always cleaned the ends of the pipes with wire-wool. I assume you're familiar with this stuff. And whereas it doesn't leave significant grooves or scoring, tiny little fragments of the iron strands can and do flake off. Could those pin-holes have been caused by such little fragments floating down the pipe and then settling? And over time, some kind of dissimilar metal electrolytic reaction has eaten its way through. Anyway, these are just my thoughts, and I thought it was about time I thanked you for your instructional videos; keep up the good work.
@zx8401ztv
@zx8401ztv 5 лет назад
I distrust plastic as well, i cant see plastic lasting like the copper pipes in your house. I live in a house from 1948, all but one copper pipe is original, 71 year old copper pipes.
@dgedi78
@dgedi78 5 лет назад
Same I trust copper, traditional brazing and mechanical junctions are made to last.
@stewartmcdonald4121
@stewartmcdonald4121 5 лет назад
Im in 50 yo copper piped house. no problems.
@junits15
@junits15 5 лет назад
Agreed I don’t trust these o-ring seals to last.
@chrisluke7786
@chrisluke7786 5 лет назад
Even slightly acidic water causes pitting in copper pipes, with the system often not making it to even 10 years. I much rather have a home-run manifold PEX system. With that you only have worry about leaks at the manifold and endpoint with no junctions to leak.
@hendersonjp
@hendersonjp 5 лет назад
Have replaced one of these . They tend to leak late at night when the heating as been switch off . They next day I would allow more water into the combey heating system. Rust got into the valve let out air but also water that's why in the morning had to top the water up .
@michaelpage8337
@michaelpage8337 5 лет назад
We used push fit fittings for compressed air at the factory and found them reliable
@andyxox4168
@andyxox4168 2 года назад
Well they’re normally rated at 6 bar so you’re pushing your luck … and a failure on a large compressed air system can have nasty consequences!
@raymondmucklow3793
@raymondmucklow3793 5 лет назад
Pex, it's a generic name for any plastic pipe by most pollyhexylene (NOT SURE OF THE SPELLING) I'm sure you can Google it if interested, at least thats my opinion it used to stand for a very specific type of pipe to replace copper pipe but over the years misused a lot by folks not in the plumbing industry, my first job in plumbing (I lived in Las Vegas at the time 6000 people moved there a month and was rising. The late 90's) we were the first crew in the US to use wirsbow or wursbo sorry about the spelling there I can't recall. Anyway the stuff was great to work with and tuff the one flaw it would break down in direct sunlight turn yellow decompose. Also you needed the $1500.00 expanding tool. We were told to try our hardest to find faults. We really couldn't. They were looking for the replacement for the grey polybutylene blue and red striped with copper crimp ring "poly" for the love of all holy stay away from the grey poly stuff with them dam crimp rings. pex came later there seems to be many manufacturers of it now they all have a style. My point to the system you just showed is it's very similar to diesel truck air lines in the US and Canada anyway im sure in the EU also. So if it's good for Dot in the US and your equivalent in the EU I'm betting it's pretty good. The difference would be the schedule of the pipe the air line stuff is much thinner. One big thing in my 13 years in the plumbing industry was the taste of water you just couldn't beat copper. But there is alot in play now tho water filters, bottled water, so straight out of the faucet isnt really popular as it used to be. I'm still a copper guy, but these press fit plastics are crazy popular here in the US right now. At the home repair stores, now are they being used by plumbers I dont now I'm not in the industry anymore. But I can speak to the durability of the press fit as a solid connection. Especially with the added spin after the press fit the air lines in trucks do not have that. They simply press in and done. Disclaimer : I might not have got the technical names spelled right. I have worked several industries and I might suffer from industrial cross over memory. Just stay way from the grey stuff. I think they only use it in mobile homes now.
@QlueDuPlessis
@QlueDuPlessis 5 лет назад
Hmmm. We got a plastic piping called "polycopper". It's a pinkish/red direct replacement for copper. It also uses the same brass ring ferrules.
@johnpossum556
@johnpossum556 5 лет назад
They call it copper because they know copper is better and this way they can mark up the plastic and charge copper-like prices for it.
@ColtaineCrows
@ColtaineCrows 5 лет назад
You can use the ferrule system for plastic too, just use a brass or copper insert in the pipe. I don't generally recommend that solution, but if done properly it works alright.
@DansKoiPond
@DansKoiPond 5 лет назад
The wall thickness of copper pipe is much thinner these days. I have used push fit throughout the house with no issue.
@lostjohnny9000
@lostjohnny9000 5 лет назад
Is there a medical version to prevent liquid seepage?
@bulwinkle
@bulwinkle 5 лет назад
Yes, it is called an elastic band.
@lostjohnny9000
@lostjohnny9000 5 лет назад
@@bulwinkle Thanks. Do I make it into a ball before inserting it?
@bulwinkle
@bulwinkle 5 лет назад
@@lostjohnny9000 or loop it tightly around the outside.
@lostjohnny9000
@lostjohnny9000 5 лет назад
@@bulwinkle My friend says his bum hole is an 'inny' not an 'outy'.
@bulwinkle
@bulwinkle 5 лет назад
@@lostjohnny9000 ah!
@dglcomputers1498
@dglcomputers1498 5 лет назад
We use connectors like this for the caravans at work, me being adept at unscrewing the connectors when I need a water hook up (generally for the jet wash) But I will categorically say that they most definitely do split when they freeze, something that we found out last year when we had a couple of sudden cold snaps, caused absolute havoc!
@JL-rx6hl
@JL-rx6hl 5 лет назад
Hi Clive, I have used pushfit for years and never had a problem with it. The other good thing about plastic pipes is, as they come in coils you can have a long run with no joins and it can be run through joists etc just like a cable(ok a thick cable)
@OAleathaO
@OAleathaO 5 лет назад
0:10 - "I bought it while I was getting some other stuff..." You don't say. Somehow I think BigClive *_never_* just buys what he originally went to the store for but at least 5-10 other things...especially if he's going to Poundland. Not criticizing BigClive...I usually do the same thing. ;)
@mickeyfilmer5551
@mickeyfilmer5551 5 лет назад
As a retired marine engineer, I have always sworn by copper pipe, but seeing this has given me food for thought. Very interesting video (as always). Keep up the good works.
@idiotstupid5904
@idiotstupid5904 5 лет назад
it's very easy to use and there are different makes, but have used the jg speedfit stuff, (available at screwfix in the uk) it is as simple as, cut pipe, use insert, insert into joint, that's it , only thing i have against it, it's more plastic in the world also am a bit against using it for mains/drinking water but that's just me
@HighestRank
@HighestRank 5 лет назад
As a sailor you without question have sworn, though the presence of copper pipe was only coincidentally “by” only due to frequency of curses in a large variety of locales. That’s the engineering part: a rule of thumb everywhere there’s water.
@HighestRank
@HighestRank 5 лет назад
idiot stupid our Sharkbite system is also questionable for water, made of a supposedly leadfree brass alloy, but who really knows?
@MitchCarlyle
@MitchCarlyle 5 лет назад
As a plumber I despise these vents. They fail often. The O ring under the cap fails. We always install a valve below them for quick and easy replacement. Some come with a "service check valve" which in theory is supposed to stop water flow when you unscrew the vent from it, In my experience those rarely work. Never seen one with a compression fitting before.... My opinion is O rings are often the weakest parts of heating systems and the first things to fail, many times they are damaged from the factory because the threads can easily cut them as things are assembled.
@throttlebottle5906
@throttlebottle5906 5 лет назад
exactly right! rubber/synthetic rubber seals are always the weak link and those silly service "check valves" are always gummed up with junk and stick open. you'll take an unscheduled bath for sure if you go blindly cranking the vent off... :))
@LaylaSpellwind
@LaylaSpellwind 5 лет назад
Not sure why I watch this. Perhaps it's just nice to hear a fellow Scotsman talk. Thanks for the video, Clive.
@BoB4jjjjs
@BoB4jjjjs 5 лет назад
They are brilliant for quick repairs, just make sure the fitting itself is protected from frost as they can expand with ice if frozen and burst. I have seen the pipe itself burst, but it has to freeze solid. Use it and you will not have any problems for at least 10 years, though I have seen it in for decades without any problems at all. If you use it foe central heating you will have very little loss from the plastic pipe between radiators. Very simple to protect against frost with a small bit of copper pipe on the return to the boiler and a pipe star to bring on the boiler to give a few degrees of heat before turning off the boiler again. Have to say though, if you have oil or propane to make sure you have enough to keep system going, it will not use a lot, but in bad frost it can be surprising. I have used these fittings without any problems. Fit and forget, but just make sure the fitting itself is not exposed to hard frost.
@HighestRank
@HighestRank 5 лет назад
It’s the same concept as a compression fitting, which I have seen shove their pipes out after a light freeze, and as such I do suspect your assumption to be correct.
@scottyoung3354
@scottyoung3354 5 лет назад
Bee using the JG speedfit for years now, never had a problem and found it more reliable than copper.
@antonina111
@antonina111 5 лет назад
For installation in my own home I'd recommend stainless steel pipe, more expensive yes but if you're going to keep living in the house for +20 years definitely worth it (or maybe aluminum core PE-X pipe with a compression sleeve system (like from the company "Rehau")). Stainless steel also being a nice selling point if you do want to sell the house. To the bottle air vent, the cap on it is supposed to be screwed shut at all times and only meant to be unscrewed when you want to vent the pipe. They will leak eventually and depending on where it's installed will cause damage by the time you notice it's defective (seen this too many times.) Source - plumber from Germany
@andyxox4168
@andyxox4168 2 года назад
Stainless … 😂😂😂 bet that’s a dream to work with!
@MrBrymstond
@MrBrymstond 5 лет назад
I use that same brass air vent on my furnace with hot water on demand. I don't have a water boiler. These vents fail all the time.
@teapackni
@teapackni 5 лет назад
Its OK new but give the plastic pipe 15 years of heat cycling, you'll have a different opinion on plastic piping.
@gelu88
@gelu88 5 лет назад
Pex has been used for decades in industry and specialist applications. I know of home builders who have used it for 20 years and have nothing but good things to say about the technology. Note that it's not recommended that it be used in direct sunlight. The UV light can indeed be bad. But in wall use its excellent
@AndrewWorkshop
@AndrewWorkshop 4 года назад
I always crimp my pex connections but this system looks great if you only have a few connections to make. In Canada Sharkbite fittings are the most popular. Always wondered how those auto vents worked, I can hear them vent if air gets into the system, I have them at the highest point in house. The only time my system seems to vent is between pressure changes. Great video. Also there are a few types of pex pipe, the standard stuff lets a small amount of oxygen into the lines, not a big deal for potable water use. Then there are types used for heating that do not let oxygen get into the heating loop, using the standard stuff in a heating system could cause the boiler guts to corrode over time.
@TheDefpom
@TheDefpom 5 лет назад
The air valve, my guess about the hinge design would be to allow air into the system, for instance a hot water system that has been turned off and so the system becomes a vacuum, which could collapse pipes or tanks, that design will allow it to suck air in to avoid it creating too large a vacuum, and will let it back out again when heated back up.
@tommyymmottommy
@tommyymmottommy 5 лет назад
Use it daily in my line of work (plumber). But not the quick fittings, we use the multi layer pipes but with press fittings pressed with hydraulic press machine.
@MrJtappin
@MrJtappin 5 лет назад
Plastic fittings and pipes are OK. Big down side is that they are invisible to pipe detection unless you do extra work / tinfoil them
@mrnmrn1
@mrnmrn1 5 лет назад
Are these full plastic? All of the ones I've seen contained an aluminium layer between two different plastic layers.
@throttlebottle5906
@throttlebottle5906 5 лет назад
@@mrnmrn1 with aluminum layer are called "pex-al-pex" commonly used in radiant heating and other closed loop systems that require an "oxygen barrier"
@mrnmrn1
@mrnmrn1 5 лет назад
@@throttlebottle5906 Ah, thanks. I thought the Al layer is for higher pressure resistance at elevated temperatures, where the plastic slightly softens.
@throttlebottle5906
@throttlebottle5906 5 лет назад
@@mrnmrn1 it also holds position when bent or stays straight! unlike the other floppy spaghetti noodle tubing
@mahlapropyzm9180
@mahlapropyzm9180 5 лет назад
As others have said, it's kind of like the float chamber in a carburetor except instead of shutting off the liquid supply as the liquid level rises, it opens a gas escape valve as the liquid level drops due to filling up with air bubbles. Simple and neat - don't know how well these things cope with the ubiquitous lime scale though.
@davidb5255
@davidb5255 5 лет назад
I've used plastic piping in both my parents house and my own with great success. I've used it on HW and CH in both 15 and 22mm, the only thing you have to use copper for in CH is the first metre from the boiler. It's great stuff because it's so easy to make connections in confined spaces, the pipe can be bent so you can feed it through tight gaps such as joists or around obsticles. It's also impact resistant, won't freeze and split like copper and has better thermal insulation even without lagging. I've mostly used the Hepworth Hep2O brand which I have found to be very robust, professional and reliable. Their original fittings had the grab ring after the O-ring seal so there was no danger of scratches from the grab ring compromising the seal. This fittings could be taken apart but you had to unscrew them. Their new stuff is more like the Speedfit with the grab ring before the O-ring. That said I have demounted and remade without any issues. The Hep2O fittings need a plastic tool to press a pair of recessed pins in to release the grab ring which is perminently trapped in the fitting so no issues with it dropping out like you had. Also no danger of accidentally releasing the grab ring. That was actually the only time I've had a failure (well my dad actually), he thinks he may have knocked the Speedfit release ring and it came apart. The pipe as you said is multi layered with the dark layer acting as a gas barrier for CH systems. It's great stuff, go for it, you'll love it. That said I also quite like doing copper solder joints and bending, and managed to do some really quite impressive multiple bends, in different axes, on some 28mm gravity feed piping.
@T-MANONE
@T-MANONE 5 лет назад
Pe-x is short for polyethylene cross. Wher the x is like WRX or MX
@willcaro1038
@willcaro1038 5 лет назад
oh... and I forgot to say... be very careful of using push fit with SS pipe (a stub up to a shower for example) I found out the hard way that the grab ring doesn't bite into the pipe reliably. Luckily it was in a bungalow. :-)
@HighestRank
@HighestRank 5 лет назад
Will Carroll any shortcut device attached to another shortcut should by its very nature become a failure.
@willcaro1038
@willcaro1038 5 лет назад
@@HighestRank Hi. After 30 years with no leaks I think it's a bit harsh and silly to label plastic plumbing a 'shortcut'. I also use copper with plain, capilliary and compression fittings but plastic allows for very long hidden runs in floors and roofs without joints. Plastic run sorface is ugly but then so are compression fittings. Modern copper is nowhere near as thick or pure as the old stuff which makes it harder to bend without buckling or pinholes. Plumbers don't like plastic because they like charging heavily for their 'skill' with copper. Plumbers were probably once quite scathing about copper when their skill with sweating lead was being undermined. Will
@nickbird7742
@nickbird7742 5 лет назад
Clive I can't believe that you use compression joints with all the soldering you do, I prefer soldering. I was talking to a plumber who told me he could no longer solder and had to use compression joints because of the risk of getting burnt or causing a fire. Smells of H&S.
@edcooper2396
@edcooper2396 5 лет назад
A lot of developers/builders will have restrictions on hot works as construction site fires aren't exactly unusual, often in commercial applications it simply isn't worth the risk. Im sure we've all seen the scorch marks on joists that plumbers of the past have left.
@nickbird7742
@nickbird7742 5 лет назад
@@edcooper2396 I understand what you are saying and is a valid point, scorched Mark's come from not use soldering mats or more common now a spray on gel and when using a open flame a fire extinguisher should be available. Most fires are started by unattended flames which brings in the competence of the user. I hate compression joints they are big and ugly, so banning the use of solder joints I see as yet another stupid idea some dick from behind a desk has made. Maybe a better idea would be to make it compulsory the use of gel and fire extinguishers.
@DavidRead52
@DavidRead52 5 лет назад
I have used plastic pipes for about 20 years and with everything it's all about the installation of the pipe there are three rules for plastic. 1. Be very clean and keep dust out. 2. Copper joints only use a wheel cutter and 3 KEEP EVERYTHING CLEAN. The failures I have seen is mostly about dust from building sites and the only other thing is people not pushing the fitting in far enough usually by not cutting on the marks. ALWAYS ALWAYS put inhibitors in your central heating as the Aav you showed will leak as it's the water pressure that makes the final seal and the smallest amount of dirt will make it leak. Finally the air vent you discribed as a wetting o ring would not be put on a sealed system and are for open vented systems. Love all your vids as I am from the "other side" as a heating engineer that dabels in electronics.
@AJB2K3
@AJB2K3 5 лет назад
Cross-linked polyethylene (PEX)
@bigrattila5
@bigrattila5 5 лет назад
I have been using those style of push-to-connect for about 10 years now and haven't had any issue. I have been doing FIRST FRC Robotics for 10 years now and the Pneumatics uses those connects for 1/4" polyurethane tubes. The fittings we use are Parker W68PLP-4-2, 364PLP-4, and W369PLP-4-2 and the pressure reaches 125 psi. I have never seen one fail and we reuse these fittings every year. Needless to say, they are excellent push-to-connect that is easy to install and removal is just as easy.
@Brian-cr6rb
@Brian-cr6rb 5 лет назад
That pivot is designed to have the air buildup push the float down, and not let it spit water out. We're talking about 12 to 20 lbs of pressure, but if you need to replace one, isolate your expansion tank , turn off the water feed, and bleed the pressure off at the blowoff valve. There will be a big mess if you dont!
@AndyK.1
@AndyK.1 5 лет назад
Brian O'C some have a small joining piece between the pipe work and valve. When the valve is removed the pipe work is sealed (spring inside). Sure you get a small spillage. ones fitted to my house were like that.
@johnfrancisdoe1563
@johnfrancisdoe1563 5 лет назад
Brian O'C I think this valve is rarely needed if you have an actual expansion tank at the highest point and small venting valves on each radiator.
@Brian-cr6rb
@Brian-cr6rb 5 лет назад
@@johnfrancisdoe1563 at our complex, we have old hydrotherms. Closed loop baseboard, 3 million BTU with 7 to 8 separate boilers in series. We have no choice but to have the expansion tank in the same room. I've been begging management to get SPRIO-VENTS installed right after the pumps, but you know how that goes. ..... with such a large, old system, you are doomed to have air enter the system, having no idea how or why. These little "spit-cans" I named them, are a great asset to me in my situation. What you explain makes absolute sense as well.
@throttlebottle5906
@throttlebottle5906 5 лет назад
@@AndyK.1 those spring loaded valves get full of crud and stick open when you remove the vent to replace or repair you end up with a geyser lol
@AndyK.1
@AndyK.1 5 лет назад
throttle bottle Yeah. Don’t you give them a quick stab and hope it seals 😂
@bodinski100
@bodinski100 5 лет назад
barrier pipe is for central heating use, to prevent oxygen ingress through the plastic......speedfit, which the brand you use is great stuff...c'mon clive, dont be afraid!
@bulwinkle
@bulwinkle 5 лет назад
How rude of you not to CAPITALIZE Clive's name!
@grrarg9319
@grrarg9319 5 лет назад
Copper pipe has antimicrobial properties which positively affect the quality of water passing through it. Dont think I like the idea of the chemicals used in PEX leaching into my drinking water system, or in fact some kind of slime build up....mmm tasty
@DrCassette
@DrCassette 5 лет назад
No electronics whatsoever, but still a very interesting video!
@fatei
@fatei 5 лет назад
Here in Switzerland we don't use much copper anymore, it's been replaced by stainless steel crimp fittings. The main plastic systems we use are RN Profix RN Flowpress JRG Sanipex MT JRG Sanipex Classic Sanipex is super interesting, it's a plastic compression fitting. Check it out if you're interested Clive!
@HighestRank
@HighestRank 5 лет назад
fatei we use stainless crimp fittings on vehicles, but nothing of that is reusable once it’s disassembled.
@deerlakediver5554
@deerlakediver5554 5 лет назад
The spring is not responsible for holding the valve closed, the water pressure in the system is. The spring just keeps the lever in position against the vent opening. This provides positive hysteresis. Fyi..... Cross-linked polyethylene, commonly abbreviated PEX
@HighestRank
@HighestRank 5 лет назад
Mark Turney positive hysteresis would barely keep a shaken valve from rattling like it was broken inside, maybe even make a new installation less than unidirectional, but soon the thin steel would fatigue or even break, then unsecured fragments would get into places they shouldn’t, reducing the effectiveness of the remaining function by an incomputationally predictable vector.
@HighestRank
@HighestRank 5 лет назад
Oh you meant to say ‘in contact with’, not “against”. My bad.
@Tryin2FlyII
@Tryin2FlyII 5 лет назад
Hi Clive interesting video -Here in the US we have something very similar to those fittings they are called "Shark Bites" (I think) and like you I am from the "old" school copper era (I am 55) and I had to do some plumbing repair awhile ago when I seen them and thought the same thing as you did "no way --this will leak like a sieve" but I tried them anyway and was blown away how easy and simple they were to install and use AND what would have easily taken me a 1/2 day to re-plumb my bathroom using copper- having to solder and make sure the length is spot on, clean and every little thing else that has to be perfect when using copper so it doesn't leak was finished just over an hours time! I could not believe it' That was 5yrs ago and still not one problem with that type of hook up I wont use anything else now if I have plumbing work to do it is just that easy and simple to use for BOTH Copper AND Plastic pipe
@EDWARDLOMBARDI-z8i
@EDWARDLOMBARDI-z8i 7 месяцев назад
Thank you! Saved me the trouble of taking the device apart to make sure you could leave the cap loose all the time VS opening it periodically to "bleed" the air out like I do with my radiators!
@ThingsWhichArentWork
@ThingsWhichArentWork 5 лет назад
I've been using PEX tubiing and JG speedfit connectors for the compressed air setup in my shed for over a decade. 8 bar pressure and there's never been a leak. The central heating system in my house is the same, but at much lower pressure. It's good stuff... just a shame that it's not a pretty as copper. Cheers!!
@HighestRank
@HighestRank 5 лет назад
Jim Conner all you need is a mouse.🛡
@blackcountrymon5697
@blackcountrymon5697 5 лет назад
Finally something I can comment on, Heating engineer of 15years here. Main benefit of plastic for me is speed of installation and how it can be fished through awkward places without the need for jointing. Also the fact it is relatively frost proof unlike copper which will often be ok the first time it freezes but bursts the second time round. Iv fitted miles of JG demountable and had very few problems with it. Also there are non demountable fittings which are slimmer and also available in copper! Given the choice though I’d always go for copper, sure it’s a bit slower going in but can look beautiful when fitted well and will last a lifetime. As for the AAV, most of the ones Iv seen the float does act directly on the sealing area unlike yours, is there a big enough annular gap between float and brass for the float to twist out of level and act directly on the seal? Thanks for the videos Clive, please never stop!
@HighestRank
@HighestRank 5 лет назад
Dan Hickman the appliance must not produce a shock hazard no matter the fault, and mechanical device must operate regardless of the installation orientations.
@TheManLab7
@TheManLab7 5 лет назад
I'm in a new build. Must be around 4 1/2 years old and I'm the only person who's ever in it. All the time I've lived here the closed loop system has always had a tiny leak. It was only a few years later when I finally found the leak. It was a 90o 22mm which leaked. I couldn't see anything wrong with it and all of the O rings inside it were absolutely fine so I've no idea why it leaked. It's been changed. To start off with, the pressure ever so slightly went down but recently it's been find.
@BrianCurtisPCT
@BrianCurtisPCT 5 лет назад
We have a similar product in the US called SharkBite (think Kleenex) "push" fittings. They are brass body and one-time, permanent installation. Used one in a friend's radiator years ago and it hasn't failed yet. Just checked and it seems they offer a similar product to what you showed, called "ProLock Push" couplings. However, they are only listed for use with PEX. Call me old fashioned, but I'd rather sweat a copper joint if at all possible. There's something satisfying seeing the solder wick into a joint and knowing you (hopefully) have a nice solid connection. Plus, you know... you get to play with FIRE! Thankfully I'm not a plumber, so it's not something I have to worry about often.
@PatrickLeeUS
@PatrickLeeUS 5 лет назад
Brian, the SharkBite appear permanent, however they are actually removable and reusable. They make a tool to remove them, looks like a giant, brown plastic c-clip.
@BrianCurtisPCT
@BrianCurtisPCT 5 лет назад
@@PatrickLeeUS Cool, just learned something new. With how tight the SharkBite fittings go together over the join, I had just assumed they were permanent. Looks like they even sell a purpose-made tool ("Disconnect Tongs") to disassemble them, should you need to do so on a frequent basis (probably for when the homeowner bodges the job and finally calls in a professional).
@publicmail2
@publicmail2 5 лет назад
Time will tell, copper is good but fails with the wrong water at 50 years or so, flex pex is turned out to be the best so far, easy to fish, minimal 90's, easy to use, low cost. I would be concerned with rigid plastic failing like cpvc in the US, it can become brittle and fail. Certain fumes on outside of pipe can make it fail, high chlorine internal.
@crimsonhalo13
@crimsonhalo13 5 лет назад
♫ Zu klein, Zu groß, Every size fit on this hose, Ram it in, Tighten it up, Turn it out, Bratwurst im dein sauerkraut!♫ *sets fire to pyrotechnic angel wings* See? Half of a Rammstein song is plumbing, the rest is angry German and flammable liquids.
@innleadair
@innleadair 5 лет назад
Used the JG push fit plumbing pipe and fittings for replumbing my place 15 years ago. Absolutely zero problems with it, quick and easy to use. However you do need more supporting clips along the length of the pipe than you would with copper. I was slightly nervous about the possibility of mouse attack, but they haven't touched the pipes, even where they have shredded the foam insulation that I used. Go play in the trap ye wee furry feckers.... Some folks have mentioned possible O ring failure over time. I use a lot of O rings in my world, hydraulics, air, water, drive belts ! The ones that fail are the ones exposed to sunlight, should be fine inside a nice dark plumbing fitting, under the floor.
Далее
What is Air Lock?
9:46
Просмотров 5 млн
Low class inline dimmer from eBay.  (with schematic)
21:15
OYUNCAK DİREKSİYON İLE ARABAYI SÜRDÜ 😱
00:16
Просмотров 3,6 млн
AUTOMATIC AIR VENTS - Plumbing Tips
7:21
Просмотров 263 тыс.
Auto air valves, are they safe against leaks?
4:17
Просмотров 9 тыс.
Fixing a dead LED street light lamp.  (SOX retrofit.)
25:55
Leaking Air Vent Repair
6:28
Просмотров 53 тыс.
Inside a LIDL insect zapper - with schematic
10:36
Просмотров 32 тыс.
Total teardown of an ASDA air fryer
21:00
Просмотров 91 тыс.
Repairing a rather nice 100 LED lamp.
10:38
Просмотров 73 тыс.
Fixing an ezOutlet with inappropriate components.
15:59