Тёмный
No video :(

Installing a Daikin FLOOR STANDING mini split⎟HVAC Installation 

Mitch Attwood
Подписаться 7 тыс.
Просмотров 55 тыс.
50% 1

Опубликовано:

 

27 авг 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 56   
@sdgdfgdasdgsdf7354
@sdgdfgdasdgsdf7354 Год назад
Finally got it up and running. The only delays we had was because we realized we needed some extra parts (I’ll list that below) ru-vid.comUgkxihMYiJNXcHdbH-7ihymsLz61l7jVyb5O . So we have a loft where our current hvac just couldn’t seem to keep cool during the summer. We have been using a window unit since we bought this house over 6 years ago (all the houses in this neighborhood were built in the 80’s and majority of the houses built like ours use a window unit). I hate window units because they are just so noisy and the one we had really only cools one side of the loft. I had contemplated upgrading our current HVAC, but with all the rising prices these days, it would take years before saving up enough to do that. With the advice of my father-in-law (used to run an HVAC business), he recommended we get an inverter instead. We thought we bought everything we needed, but there were just a few other parts we didn’t anticipate needing (which is what caused most of our delay). My friend and father-in-law did all the work to get it installed and running and now we have nice cool air circulating nicely throughout the entire loft. It is very quiet and even the outside unit is much quieter than our main HVAC unit. Saved ourselves thousands getting this.
@robalexander7348
@robalexander7348 Год назад
Hi Mitch,this looks a identicle model to my Daiken 5 kw floor mounted split sysyem, they are very efficient for all weather conditions here in the Southern Highlands NSW... Compliments on a nice neat install 👍
@thearrislawson8537
@thearrislawson8537 6 месяцев назад
A friend just told me about this type of unit nice install 🔥
@nixaeagle141
@nixaeagle141 2 года назад
That wall radiator is slick .
@salvatoregiovanni8967
@salvatoregiovanni8967 Месяц назад
2:56 whispers to self: “That’s not going anywhere.”
@connorbloom9616
@connorbloom9616 2 года назад
Nice work brother! I'm on a job where the client wants 3 floor mount Daikin handlers recessed into the wall of every bedroom, just the smaller gray back. I'll let you know the outcome. Gotta scab in 2×4 to screw into
@maracservices
@maracservices 2 года назад
I’m very interested how that will look. All the cuts in the wall will have to be perfect, won’t be easy 😬 good luck brother
@suldaancooling4207
@suldaancooling4207 2 года назад
Fantastically work thanks eng👍👍🩸
@maracservices
@maracservices 2 года назад
Thanks man!
@jasonliu9614
@jasonliu9614 2 года назад
nice and neat, good one.
@maracservices
@maracservices 2 года назад
Thanks mate
@Ani-um3ls
@Ani-um3ls 11 месяцев назад
Very nice clean work. But the minimum pipe length for all mininsplit type is 3m. Look at the manual instalation first.
@SilasMoleCatcher
@SilasMoleCatcher 7 месяцев назад
Why only 3?
@jansenspanzu4083
@jansenspanzu4083 26 дней назад
Because the extra meter of pipe needs more refrigerant ​@@SilasMoleCatcher
@SilasMoleCatcher
@SilasMoleCatcher 26 дней назад
@@jansenspanzu4083 ??
@jennamoonchild
@jennamoonchild Год назад
Hi, did you check what is the minimum pipe length? Usually it is 2 to 3 metres (6 to 9 feets). I don't think it's much of a problem, if weather stays over zero Celsius. If weather stays below zero, it will constantly go to defrosting mode.
@maracservices
@maracservices Год назад
Yep sure did. You’re correct though, this is shorter then the minimum length they state in the specs however I got told that it’s fine in my location by Daikin tech support. Long story short, the lowest temp you’ll ever get here on the coldest winters morning is about 6°c and that is rare. Normally a winters morning is about 15°c. I’ve never heard back from the client so I assume all is well.
@jennamoonchild
@jennamoonchild Год назад
@@maracservices Hi Mitch, I was almost sure there are no temps below zero there. I'm from Finland and I have three heat pumps ...and a fireplace ..and a few stoves. And a sauna. I'm like I don't belong in this country, because it's almost spring, when I'm becoming accustomed these freezing temps we have here in winter.
@maracservices
@maracservices Год назад
@@jennamoonchild Finnish people must be tougher then Australians because I reckon I would not be able to survive such harsh climates haha. Sauna and ice baths sound crazy to me! A lot of houses here in Australia don’t have insulation in them to save money because it’s not necessarily required with our climate. Although I’d still put it in my house if I had the option.
@benjaminwenman657
@benjaminwenman657 Год назад
I've never seen that duct that you use before. Looks like it has way more room then the stuff I've used.
@ssikkema4222
@ssikkema4222 10 дней назад
nice video.. but please the music, autotune hurts my ears. 😅
@ianorr760
@ianorr760 2 года назад
That’s the first time I’ve seen a console install, nice work as usual mate… No room up high I assume??? My U4 fault had no power on t3, so I swapped out the outdoor board and fan motor and away it went…. Thanks again for sharing 👍🏼.. Do you use the Daikin global service bank for sourcing the parts/models???
@maracservices
@maracservices 2 года назад
Thanks mate. Yeah so this room had no room up high (to many windows). That’s good to hear about the U4 fault 👍🏻. I actually haven’t used the global service bank to be honest. I just ring spare parts and get a price and availability over the phone and then send them a purchase order via email. Iv got a few Daikin service call videos I want to get out but unfortunately I’m waiting for the parts to come in stock again. Daikin seem to be struggling to keep everything in stock at the moment.
@frankrizzo7307
@frankrizzo7307 5 месяцев назад
I'm thinking of getting the MFZ-KJ for my basement, but the operation manual mentions nothing about condensate. Is there a built in pump or do you need to add a condensate pump?
@musakavalci9470
@musakavalci9470 Год назад
Excellent work mate. Tidy. Not having a pop just a couple of questions. No strength/pressure test before vacuuming lines? what's the minimum lineset recommended for that model unit?
@dylb8801
@dylb8801 18 дней назад
So Ive just provided you with a few more views across you videos lol but noticed you didn't run a vac stat back in the day and vac through gauges/1/4 lines? Seeing you are more evacuation informed do you wish you knew what you knew now back in the day lol
@terrancegrant1664
@terrancegrant1664 4 месяца назад
I got one; any ideal of how to clean it?
@alvaroherbert35
@alvaroherbert35 2 месяца назад
What Size of electrical wire for thay unit?
@dukeraul624
@dukeraul624 2 года назад
Nice n clean. How many BTU’s?
@maracservices
@maracservices 2 года назад
3.5kW which if I’m correct is 12,000 BTU’s (I think).
@dukeraul624
@dukeraul624 2 года назад
@@maracservices 👍thanks
@arishem555
@arishem555 Год назад
Hey, Mitch. How is the unit doing after 8 months? Can you please share anything? :) Thnx!
@maracservices
@maracservices Год назад
Running perfectly fine mate. The customer is very happy.
@arishem555
@arishem555 Год назад
@@maracservices THank you, Mitch. If you don't mind, - cannot find info about drain hose. Daikin specs saying "13/16 connector". But there is no such thing as 13/16 hose available. What hose should I order? both 9000BTU and 18000 BTU units have the same "13/16" connector.
@charinafarry7149
@charinafarry7149 Год назад
wow
@alisondennis4098
@alisondennis4098 Год назад
"You're body only make you go lovey dovey"? You have got to be kidding me. Sounds like written by someone who never graduated from high school. Makes me wonder about the quality of Daikin ACs.
@Karma46819
@Karma46819 5 месяцев назад
Does the floor model not come with the connectors already attached to the indoor unit? My normal Daikin split unit does
@maracservices
@maracservices 5 месяцев назад
Sorry mate dont really know what you mean. Do you mean flare nuts? To connect the pipe to the unit?
@AM-si1jt
@AM-si1jt 2 года назад
i want to have one and how much is cost
@agostinhomartins8373
@agostinhomartins8373 Год назад
Hey mate I have one of these currently flashing green and not working in heating, do you know any possible causes? Can't seem to find this model on any daikin app.
@maracservices
@maracservices Год назад
Does it have a remote controller?
@agostinhomartins8373
@agostinhomartins8373 Год назад
@@maracservices yeah it does mate but haven't been out to check it just yet
@maracservices
@maracservices Год назад
@@agostinhomartins8373 no worries. When you do, hold down the cancel button and scroll through the fault codes mate.
@agostinhomartins8373
@agostinhomartins8373 Год назад
@@maracservices 👍👍
@SOCIETECDSArnouville
@SOCIETECDSArnouville Год назад
Top
@milerkos
@milerkos 2 года назад
I WOULD LIKE TO HEAR HOW LOUD IS INDOOR UNIT.
@maracservices
@maracservices 2 года назад
Next time I come across one I’ll make a video 👍🏻
@nonfiction_4life156
@nonfiction_4life156 Год назад
Don't bother wasting your time showing Miler !! It's so quiet they are used in music recording studios !! Get a hold of yourself Mr. Kos
@prowesstv
@prowesstv 2 года назад
No start up vid for the VRV ?
@banega2311
@banega2311 9 месяцев назад
And you are waiting for an electrician to connect three wires, phase, zero and ground??? )))))
@TheJuice484
@TheJuice484 2 года назад
Line set too short
@maxd4968
@maxd4968 Год назад
Mine comes straight out the back and into the outdoor. It’s been working fine for 18 years
@hatenu2
@hatenu2 11 месяцев назад
No such thing. Short line causes noise
@kratos2269
@kratos2269 День назад
Really only affects multi head systems… in my experience and from tech support from Daikin.
@daveyboy8907
@daveyboy8907 Год назад
Music ruins it man.
Далее
How To Install A Daikin Dual Zone Ductless Mini Split
33:45
I Took a LUNCHBAR OFF A Poster 🤯 #shorts
00:17
Просмотров 5 млн
Installing a Daikin Ductless Mini Split
16:17
Просмотров 4,3 тыс.
Installing a 3 ZONE Ductless HVAC System
16:52
Просмотров 123 тыс.
#1 Reason Why DUCTLESS Units Fail | How I Fix It...
13:59
Fujitsu 8 Head 4 Ton Ductless Multi
4:51
Просмотров 86 тыс.
I Took a LUNCHBAR OFF A Poster 🤯 #shorts
00:17
Просмотров 5 млн