50% 1

This 20x30 shop is going to have several power tools and laser engravers and many other power hungry applications so its time to get the electrical outlets and light boxes wired for use. In this video I run 14 and 12 awg wire to lights and outlets. Next I get the receptacles installed as well as light switches. I do get the wire installed into the main breaker box but dont show that on camera.
SethCraft is a participant in the Amazon Associates Program, an affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to amazon.com

Опубликовано:

 

27 авг 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 14   
@jllaine
@jllaine 7 месяцев назад
Very nice
@sethcraftworkshop
@sethcraftworkshop 7 месяцев назад
Thank you.
@workbenchz
@workbenchz 7 месяцев назад
That is a lot of work. I was expecting you'd put some outlets higher for "above the bench/countertop" power, are there plans for mounting power strips to the front/underside of the workbenches and countertops?
@sethcraftworkshop
@sethcraftworkshop 7 месяцев назад
I went back and forth on outlet placement. Yes there will be power strips mounted. Might take them through the bench and up on the wall. Will have to see how that goes.
@johnisley4578
@johnisley4578 8 месяцев назад
Another job well done again. Cheers.
@sethcraftworkshop
@sethcraftworkshop 8 месяцев назад
Thank you. Getting power to the shop is a big step.
@forsya
@forsya 2 месяца назад
Why not place outlet boxes at 40-48" height (European style)? Prevents having to bend down to plug in and blocking outlet with boxes, tools, equipment, etc.
@godisnowhere4u
@godisnowhere4u 8 месяцев назад
think the answer is NO. but i will ask the question . can both of those separate electrical systems share the SAME GROUND ROD. please. explain why. is it because in the rare case of a fault or short circuit current will enter the other system thank you
@sethcraftworkshop
@sethcraftworkshop 8 месяцев назад
Because this is a grid sub panel system and off grid system I have them linked to the same ground. You have to make sure that the neutral/ground link in the off grid inverter is disconnected. My orient power inverter had a single screw that separated the neutral from ground. All use the same ground rod.
@Last_day_events
@Last_day_events 8 месяцев назад
Why not a gray switch when you enter the building?
@sethcraftworkshop
@sethcraftworkshop 8 месяцев назад
Would have been a good idea. The gray is mostly a backup on the other power system.
@algoodmonin2172
@algoodmonin2172 8 месяцев назад
What screws did you use to attach Fiber Cement Siding?
@sethcraftworkshop
@sethcraftworkshop 8 месяцев назад
I used exterior deck screws However you should use galvanized spiral shank nails to be proper.
@algoodmonin2172
@algoodmonin2172 8 месяцев назад
@@sethcraftworkshop Thanks
Далее
Wall Insulation R-13 Install - Build a 20 x 30 Workshop
11:21
Woman = best friend🤣
00:31
Просмотров 2,3 млн
6 MISTAKES DIYers Make When Wiring Outlets
11:28
Просмотров 2,2 млн
Build Custom Shop Shelves - Build a 20x30 Workshop
21:18
How to Wire an Electrical Panel - Good Workmanship
27:38
Electrical Wiring Basics
23:40
Просмотров 2,8 млн