Тёмный

Installing Victron Multiplus II parallel in an RV!  

Salty Trips
Подписаться 4,4 тыс.
Просмотров 3,9 тыс.
50% 1

Amazon Links:
Dinkle connectors- amzn.to/3x7uolG
6 x 6 junction box- amzn.to/49BLwOo
Li Time 12v 100ah Mini- amzn.to/46mJrUK
Li Time 12v 100ah- amzn.to/46pvrJP
Li Time 12v 400ah- amzn.to/3Zz0hgL
Li Time 24v 200ah- amzn.to/453N1Sz
12v MultiPlus II- amzn.to/3UZ8WZI
24v MultiPlus II- amzn.to/3Pv9K4g
Victron Shunt- amzn.to/3EUjwI0
Victron Distributor- www.amazon.com/dp/B07FML8JHG/...
Cerbo GX- www.amazon.com/dp/B0851KGF57/...
GX 70 screen- amzn.to/463YH9f
Power switch- amzn.to/464ONnL
Mega fuse- amzn.to/3ESqkGd
Crimper- amzn.to/3rvhg79
Wire 2/0- amzn.to/3Ztyyhv
6/4 cable- amzn.to/3PRcABJ
Playlist: RV Victron power & solar - • RV Victron Power and S...

Развлечения

Опубликовано:

 

23 мар 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 57   
@saltytrips
@saltytrips Месяц назад
Product Links: Dinkle connectors- amzn.to/4a1V05g Green Dinkle connectors- amzn.to/4bun1Uw 6 x 6 junction box- amzn.to/49BLwOo Additional links in the description are of this video.
@internationalconnector
@internationalconnector 11 дней назад
Hi Chris! You actually bought those terminal blocks from me at International Connector. I just found this video yesterday. I built a custom combiner today to match what you did here and wanted to chat with you about what else might be helpful. For example, printed marking tags showing L1, L2, N and GND. I also, wanted to address your concerns at the end of the video. I have these colors in a larger size block named the Dinkle DK35N. It would give you a maximum UL rating of 150 amps instead of the 60 amp limit on the DK10N block. I really enjoyed your video. Keep making great content!
@saltytrips
@saltytrips 11 дней назад
The concern at the end had nothing to do with the Dinkle connector amp rating, it was the threat of overloading the unprotected neutral line using the power assist from the inverter exceeding the neutral lines 50 amp rating. I don’t believe tags would be necessary, that’s what the color coordination was for. Great product, thanks for the input. If you have any more questions feel free to reach out at saltytripsrv@gmail.com
@dougwrobinson
@dougwrobinson 2 месяца назад
Great video, first time seeing 2 of these in parallel.
@saltytrips
@saltytrips 2 месяца назад
Thanks 🙏🏻, Hopefully this video will help out others looking to do the same.
@BorealisNights
@BorealisNights Месяц назад
Nothin' wrong with 'OCD' when you're doing electrical work!!!🤔👍🏼✌🏼🇨🇦
@grayclink6995
@grayclink6995 18 дней назад
You can also protect the output to 50a and join the two multis back together before the panel in a standard 2 pole breaker box.
@saltytrips
@saltytrips 18 дней назад
Correct, that would be one solution, just wanted to make people aware of the possibility hazard.
@BenjaminMedlock
@BenjaminMedlock 2 месяца назад
Great video.
@gepponet4963
@gepponet4963 2 месяца назад
Grazie per i tuoi video !! Saluti da Italia (Roma)
@kennedymallery665
@kennedymallery665 2 месяца назад
You’re going in big my man!! Definitely a unique setup, 2500 watts of solar upcoming?? I’m looking forward to that.
@saltytrips
@saltytrips 2 месяца назад
Yes, going to be i stalling panels in the next day or two and then about a week or so to edit and upload the video.
@2muchtime26
@2muchtime26 8 дней назад
Hey i have 2 10kw inverters ran in parallel for my home but I ran each output to its own double pole 60amp breaker in the panel. I made sure the outputs of each inverter ended up on the same corresponding legs and they run my house great. Is there anything wrong with doing it this way or is it just less congestion in the panel running a combiner box like you did? Also great video man, thank you for taking the time to show everyone!
@justbeastit
@justbeastit 2 месяца назад
I think the difference in the wattage between the shunt and the load side is the inverter's efficiency loss. The shunt is showing what he's throwing out while the inverter is doing the same, minus the its own inefficiency. Awesome setup. I want to get another MP and do the same!
@justbeastit
@justbeastit 2 месяца назад
Plus the DC loads...
@saltytrips
@saltytrips 2 месяца назад
Efficiency loss doesn’t explain the discrepancy, AC loads reading 30% lower than they should and DC loads reading 200-300% higher than they should. Efficiency loss would be like 5%. These are just reading inaccurately.
@TRAVISGOLDIE
@TRAVISGOLDIE 2 месяца назад
You need to tell the cerbo to disregard battery readings from the inverter and only accept from the shunt, that’s your error appearance
@saltytrips
@saltytrips 2 месяца назад
@@TRAVISGOLDIE thanks, it was set to automatic, switched it to Shunt only now 🤞
@kb3usa206
@kb3usa206 14 дней назад
Nice job. You addressed some concerns been wondering as I plan for the same dual inverter setup. Have you had any issues yet with overloading the neutral while on power assist? The $700+ for two splice boxes with breakers seemed like a lot and I was hoping to find an alternate solution. Also, did you have to increase any wire size going to two inverters? Thanks!
@saltytrips
@saltytrips 14 дней назад
We don’t get anywhere close to going over 50amps of power usage. So over loading neutral hasn’t come close to being a concern yet. With two AC’s running and the clothes drying we are still under 4,500 watts. Even if we kicked on the microwave at the same time we would still be under 6,000 watts. If you have three AC’s then or some other high power draw then that might be an issue. Wire size to the inverters are fine, we did change up our battery wires configuration, which will be in an up coming video.
@darrinwolf9411
@darrinwolf9411 21 день назад
Great Video thanks for making it. I currently have one multi-plus Getting ready to add second one. you answered a lot of questions before I had a chance to ask them. Your link for the Dinkle connectors. Only shows red and black were you able to buy the white and green separately? If so, can you share that link?
@saltytrips
@saltytrips 21 день назад
Thats why i made the video because i couldn’t find one out there. I added a link for green connectors on the video and I’ll leave it here too. amzn.to/4bun1Uw White ones come with the others red and black ones.
@geored66
@geored66 Месяц назад
saltytrips Thanks for video. Did you have to do any extra programming using VE.Bus System Configurator or was Victron Connect all that you used?
@saltytrips
@saltytrips Месяц назад
When you install the parallel inverter the slave one just copies the setting from the master. Long as your Master setting are correct you wont have to do any additional programming
@dennisbachman4316
@dennisbachman4316 2 месяца назад
Cool video. You’re a pretty handy guy! So I’m installing an MP2 2x120 right now, just waiting for a few more items. Just curious, how’d you hook up your Cerbo GX to the touch… that wire length is so short. Looks like you have a Cougar, like mine. I wanted to mount everything in the front storage but I’m afraid I’m going to have to mount the Cerbo right inside the lower compartment. I have my touch in the same spot except higher on the wall. Thanks-Dennis
@saltytrips
@saltytrips 2 месяца назад
Extensions, Here’s the full install video, hope it helps ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-9BvVx8bgEQ0.htmlsi=yqyq1sZ67g-wxn-N
@dennisbachman4316
@dennisbachman4316 2 месяца назад
@@saltytripsany issues with the extensions at all? I can either run long ve direct cables (3) or run the extensions (usb and hdmi) from the Touch 70. I just don’t want to have to purchase shorter ve direct cables and then longer ones later. Thanks!
@saltytrips
@saltytrips 2 месяца назад
@@dennisbachman4316 no issues with extensions so far 👍
@shammer427
@shammer427 Месяц назад
I have a 24V 2x120 3000kva in my pass thru on my trailer. Question is how did you manage to keep all of that setup cool? Did you install a better bluetooth plug in on the Cerbo GX?
@saltytrips
@saltytrips Месяц назад
It never really gets hot enough for to worry about. Not sure what your referring to with “bluetooth plug in” but here’s the original install, maybe that will help ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-9BvVx8bgEQ0.htmlsi=0qgz7a7capAMjqoe
@thomdukesherer2744
@thomdukesherer2744 Месяц назад
Question about the battery cables to the shunt. Did you have to change the 2/0 to something larger?
@saltytrips
@saltytrips Месяц назад
No, same 2/0 wire.
@thomdukesherer2744
@thomdukesherer2744 Месяц назад
@@saltytrips I pulled the trigger on the 2nd multiplus ii and dinkle connectors. Thanks for doing the video.
@jeffdillon8540
@jeffdillon8540 2 месяца назад
Curious why you didn’t use ferrules?
@saltytrips
@saltytrips 2 месяца назад
Don’t need too
@CherishtheJourneyy
@CherishtheJourneyy 2 месяца назад
On your screen the AC loads is how much load your RV is pulling on the AC side, the battery load is showing total watts being pulled from the batteries including both inverters and DC loads combined.
@saltytrips
@saltytrips 2 месяца назад
I know they are supposed to but the read outs were way off actual usage. My DC load consist of interior lights which maybe use 50 watts and at times and it was showing close to 500 or more watts at times. There is some extreme inaccuracy in the AC and DC load reporting when inverting, when in pass through mode it reports accurately. The AC load was reporting 30-40% lower than what was actually being used. Did you not notice the extreme discrepancies?
@CherishtheJourneyy
@CherishtheJourneyy 2 месяца назад
@@saltytrips I would check the settings on the shunt to make sure it is programmed properly. Also did you take out the old 12v converter?
@saltytrips
@saltytrips 2 месяца назад
@@CherishtheJourneyy ru-vid.com/group/PLXL0DAEhCeew8ymmeXnQZbforpQDwK_e3&si=SrNm3d13MHc7wcS1
@slayermtb_7848
@slayermtb_7848 2 месяца назад
Any issue with having the 2 inverters so close? The manual says to have at least 100mm space on either side . Thanks
@saltytrips
@saltytrips 2 месяца назад
Manual says 10cm on top or bottom for ventilation, side by side doesn’t affect that, there’s no side ventilation.
@slayermtb_7848
@slayermtb_7848 2 месяца назад
@@saltytrips Cool. I asked because the visual quick reference sheet that came in the box of mine show 100mm for both sides and top . I agree with you though as there is no vents on the sides , only top and bottom Thanks for your response .
@TRAVISGOLDIE
@TRAVISGOLDIE 2 месяца назад
I remember the original install, what’s the main reasons you went parallel later and not initially? I see you also did away with your 12v agm?
@saltytrips
@saltytrips 2 месяца назад
Because didn’t need it at the time, didn’t realize power grids at RV parks were so unreliable, so for our critters it became uber important. Also once you get that power ball rolling it hard not to just keep making it bigger. Rapping up the solar install to stay tuned for that soon.
@saltytrips
@saltytrips 2 месяца назад
ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-EV0HWocQqRE.htmlsi=XBx9c7liouiSP5mj
@ryanbraun2000
@ryanbraun2000 Месяц назад
Technically 4800 watts, correct? I believe those are 2400 watt inverters. Is that 12 or 24 volt system? 4/0 battery cables? Great video, Thank You
@saltytrips
@saltytrips Месяц назад
In parallel it will run 4,800 watts all day long, it can handle loads up to 6,000 watts for a period of time before overloading. Closer to 6,000 the less time it has before over load. Here’s a link to the original install which will answer most of your questions ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-9BvVx8bgEQ0.htmlsi=rnr5tkQeZbCrYL8E
@TheSnakeman3
@TheSnakeman3 2 месяца назад
I have a 12/3000/120 Multiplus ii that I am about to hook up. With 50Amp shore power and the inverter in charge only, can you run both ACs and everything pass through the inverter? Will it allow a full 50 amps through both legs for 100 amps total when not inverting?
@saltytrips
@saltytrips 2 месяца назад
Is yours the 2x120 ?
@TheSnakeman3
@TheSnakeman3 2 месяца назад
@@saltytrips yes it is.
@saltytrips
@saltytrips 2 месяца назад
@@TheSnakeman3 then yes, thats exactly what’s it’s designed to do. Here is the first inverter install ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-9BvVx8bgEQ0.htmlsi=IOeDwB0D9S75egaa
@bradr7015
@bradr7015 2 месяца назад
Any issues using the parallel setup and your Hughes Power Watchdog?
@saltytrips
@saltytrips 2 месяца назад
@@bradr7015 none, I couldn’t see how it would.
@talk2hubba
@talk2hubba 10 дней назад
3000/120volt only 25 amp on each side. but you have 50 amp service?
@saltytrips
@saltytrips 10 дней назад
25 + 25 = 50
@ToniDoniec
@ToniDoniec Месяц назад
I'm sorry, I don't get it. I appreciate your time making the video but you spend too much time connecting wiring watching nothing but your wrists but not enough explaining how the wiring is done for the parallel setup with perhaps a picture diagram? Does each inverter get one hot leg (L1 to one and L2 to the other) and then the white nuetral wire is shared between the two inverters? Thank you.
@saltytrips
@saltytrips Месяц назад
@3:20-6:30 wiring explained (color coordinated with L1,L2,N,G) @18:40 you can clearly seem them connected. You can see the lines going from the inverters to the junction box’s. I even color coordinated them, I’m not sure how I could make it clearer. I showed and explained the wiring multiple times. Have you installed one inverter yet? Maybe you should start with this video here ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-9BvVx8bgEQ0.htmlsi=kgrp58bWi4oE7-u5