Тёмный

Introduction to UL 508A Industrial Electrical Control Panels with PLC 

Tim Wilborne
Подписаться 83 тыс.
Просмотров 73 тыс.
50% 1

In this video we take an exciting look at UL 508A Industrial Control Panels including PLCs and HMIs.
Get the full details of this lesson at:
twcontrols.com/ul508a-control...
Items used in this video:
UL 508A Industrial Control Panel twcontrols.com/control-panels
The above links make these videos possible. Please use them!
Support these videos while you advance your skills courses.twcontrols.com/

Наука

Опубликовано:

 

1 дек 2020

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 112   
@adampitt7052
@adampitt7052 3 года назад
This is what Ive been waiting for. Looking forward to this series.
@TimWilborne
@TimWilborne 3 года назад
Glad to hear it Adam
@brady0630
@brady0630 Год назад
you probably have the best presentation so far. good stuff. will be watching the entire series.
@TimWilborne
@TimWilborne Год назад
Glad to hear that, thanks!
@jasonryan2175
@jasonryan2175 3 года назад
love it! do more of these!!
@TimWilborne
@TimWilborne 3 года назад
We plan on it Jason!
@JB-hq7vp
@JB-hq7vp 3 года назад
I work for Prime Controls in Dallas and really enjoy your videos!
@TimWilborne
@TimWilborne 3 года назад
Glad you like them Jeremy!
@italyinmoto8494
@italyinmoto8494 Год назад
Thank you so much Tim! I just love watching yours video!
@TimWilborne
@TimWilborne Год назад
Glad to hear it!
@taylor2160
@taylor2160 Год назад
I would like to question the spacing requirements for your components. UL got me with that on my first panel that got inspected. Typically a power supply, especially ones that convert 3 phase into 24vdc require at least about 1.5 inches above and below. It does not look like those requirements have been met. Love your videos man. Great content. Would love to ve able to bounce automation ideas back and forth.
@NeGRaDiCaLz
@NeGRaDiCaLz Год назад
I like that your disconnect handle will literally cover an inch of your HMI when you turn it on with the door closed.
@TimWilborne
@TimWilborne Год назад
That's all you got out of the video....😂
@lokeshwar4093
@lokeshwar4093 3 года назад
wonderful, I liked your all playlist and save in library and subscribed before your promotional words :)
@TimWilborne
@TimWilborne 3 года назад
Awesome, thank you!
@jomahank6314
@jomahank6314 2 года назад
great way of teatching thank you from Morocco.
@TimWilborne
@TimWilborne 2 года назад
You are welcome!
@CommercialGasEngineerVideos
@CommercialGasEngineerVideos 2 года назад
Many thanks from the UK.
@TimWilborne
@TimWilborne 2 года назад
You are welcome!
@k50159
@k50159 2 месяца назад
Much appreciated Tim
@TimWilborne
@TimWilborne 2 месяца назад
You are welcome
@hjp520
@hjp520 3 месяца назад
Thanks from New Orleans!!
@TimWilborne
@TimWilborne 3 месяца назад
You are welcome
@rixpanapasa8977
@rixpanapasa8977 3 года назад
Awesome vid Tim....Thanks
@TimWilborne
@TimWilborne 3 года назад
Put in your request for what you want to see in this series.
@rixpanapasa8977
@rixpanapasa8977 3 года назад
@@TimWilborne would really like to see how you size up and set up the electrical panel .
@faschwank
@faschwank 6 месяцев назад
Nice job with the ferrules.
@TimWilborne
@TimWilborne 6 месяцев назад
Thanks!
@gurjantsingh6647
@gurjantsingh6647 3 года назад
Good video' I want to learn this tips.
@TimWilborne
@TimWilborne 3 года назад
Great, we'll be uploading more videos about this soon so subscribe.
@aboshnb97
@aboshnb97 Год назад
Hi Tim, Thanks a lot for all the tutorial videos. I learned a lot by following your tutorials really appreciate that. Is there any video about calculating the total load of the whole control panel by going to each components? I'm trying to get that for my application in order to size a step down transformer and a safety disconnect switch. Thanks a lot!!!
@TimWilborne
@TimWilborne Год назад
This is one I have avoid because it's not as simple as adding up all the loads and multiplying that by safety factor, it depends on the types of loads, size, and locality.
@bblee2150
@bblee2150 2 года назад
Nice video Tim! Can you talk about the wire color coding when building a panel? I can't find much information for the color coding for such as AC voltage, DC voltage and etc. Thank you!
@TimWilborne
@TimWilborne 2 года назад
I am going to soon but you won't like it. The only color that is required is green for grounded conductors :)
@joshkraai7657
@joshkraai7657 3 года назад
I really enjoy this video break down in easy terms to understand. I would like to see in one of your videos how and why you choose the panel lay out you did. Like which components can be next to one another and how you have to be careful about wiring crossing each other (high voltage/low voltage)
@TimWilborne
@TimWilborne 3 года назад
We're working on a panel layout video. It is a little tricky but hopefully we'll get the kinks worked out.
@christopherlyons7613
@christopherlyons7613 Год назад
​@@TimWilborneHI Tim. Have you made any progress on doing the Panel Layout video? That would be great information to show and it could help many of us. Thanks.
@trevorthobe8528
@trevorthobe8528 2 года назад
Hey Tim! Have you done any videos yet going over how to calculate SCCR?
@TimWilborne
@TimWilborne 2 года назад
It is up for the next group of control panel videos.
@isaacparry8686
@isaacparry8686 2 года назад
I watched the "hater" episode. I like how you were accused of selling yourself for AB when in reality most things you have in your videos is AD stuff. That's a testament to an untrained eye. Minus maybe the PLC! I'm pretty sure I even saw a DL05 in there somewhere. Personally I'd rather use the DoMore! in one of it's various form factors, or I hate to say it, a Micro800 of some sort for simple applications. (although you absolutely should hard code you're variables in those as they have a tendency to go brain dead for no reason!) The Click! isn't much more reliable, but it is cheaper. Both software's are free. (At least the non-developer edition for the AB) Anyway, I like you're series, you are a pioneer in the socialization of the field. WE NEED MORE CONTROLS GUYS, people don't understand how fun this stuff is! I almost want to keep it a secret, or everybody will want to do it!
@ThatNerdyCoolGuy
@ThatNerdyCoolGuy 2 года назад
Just wanted to let you know that I found your youtube channel from Linkedin and Jake Hall!
@TimWilborne
@TimWilborne 2 года назад
Love Jake Hall's videos!
@csdrip
@csdrip 3 года назад
Is there a list of labels that are required by UL for ICP's? For instance "to maintain overcurrent protection...."
@TimWilborne
@TimWilborne 3 года назад
Not in a broad sense. There are some labels every panel may require but many are specific for the situation.
@coasterbp
@coasterbp 3 года назад
Hey Tim, Do you through bolt your components to your back plane or drill and tap?
@TimWilborne
@TimWilborne 3 года назад
I'm 99% sure code doesn't allow through bolting components. And if code doesn't prohibit it then it should. I always drill and tap. If the diameter is too large for the thickness of the panel then they make volts that can be riveted into the panel.
@dwaynes5983
@dwaynes5983 2 года назад
I always leave the space above disconnect open. Thought it was code back in 90s??
@EETechs
@EETechs 2 года назад
Can you use MTW 16 or 18 AWG wire inside control panels for the control wiring to save on money for wire as long as the proper fuse size is chosen? I read somewhere that UL508a says only 20 AWG or smaller wire has special requirements limited to PLC connections only.
@TimWilborne
@TimWilborne 2 года назад
UL says "power wiring" must be 14awg, with a few exceptions, they don't specify control wire size.
@steveestey
@steveestey 2 года назад
Hi Tim, great series! I noticed one thing in particular that surprised me, you don't label your panel components, why is that? Also I live in Canada and this may just be a difference in code requirements but I also noticed no fuse charts on the door, are you guys not required?
@TimWilborne
@TimWilborne 2 года назад
Our UL standards are the same. As far as labeling, it can be done by the component, on the door in a panel layout such as you mention, or on a drawing. This is one of our training panels so it get reconfigured often, hence not permanent labels.
@christopherlyons7613
@christopherlyons7613 Год назад
Hi Tim. Thanks for your videos. I have a question about UL508 wire colors. Can you please provide some basic info on recommended AC & DC wire color guidelines. Also, what format do you use for your wire numbers? Thanks.
@TimWilborne
@TimWilborne Год назад
I have a video on wire colors in my drafts. Many people don't like my answer but according to UL 508A for industrial control panels which is what 99% of labels are, you only need to mark grounds as green. The rest is regional and even varies across the USA. I'll have some examples in it. Here are some sample wiring diagrams, the wire numbers are based on the page and line number. controls.tw/sample-drawings
@christopherlyons7613
@christopherlyons7613 Год назад
@@TimWilborne Thanks. Doesn't UL508A make some statements about wire colors (i.e.66.5 (Power) & 66.9.1 (Control Circuits) (not sure if these are current section #s)? I believe they state that all ungrounded AC power connections should be BLACK (RED if < supply voltage) and all grounded AC connections should be GREY or WHITE. For DC control circuits they say to use BLUE for all ungrounded DC connections and WHITE WITH BLUE STRIPE for grounded DC connections. I realize there is some openness in the spec regarding these colors. But if you were to follow this basic color scheme would that be sufficient? Are there any other basic colors that you tend to use? Regarding your upcoming Wire Color video, any idea when it will be released? Looking for a beta tester? Appreciate any help you can provide. Thanks.
@TimWilborne
@TimWilborne Год назад
@@christopherlyons7613 ​ No, this is the most commonly misused sections. 65, 66, and 67 are for Industrial Machinery, not industrial control panels. Industrial Machinery labels are very rarely used, in fact I've never seen one.
@leandrodortaduque3392
@leandrodortaduque3392 2 года назад
What kind of license/permit/certification do I need to do this kind of job and being certified by UL?
@TimWilborne
@TimWilborne 2 года назад
For UL, it is UL508A
@rcandrew8780
@rcandrew8780 Год назад
Hi Tim,great videos..i really like that disconnect switch what brand and or PN is it?
@TimWilborne
@TimWilborne Год назад
It is a Noark.
@rcandrew8780
@rcandrew8780 Год назад
Thank you!
@kevinburt3075
@kevinburt3075 3 года назад
How do you make the label for the outside of the panel is this special software ?
@TimWilborne
@TimWilborne 3 года назад
Hi Kevin. I use a Brady BMP71 for all my labeling. See links below. BMP71 amzn.to/3cqs3FN Nameplate labels amzn.to/3oAsDD9
@kevinburt3075
@kevinburt3075 3 года назад
@@TimWilborne thank you
@rameshnatarajan5746
@rameshnatarajan5746 2 года назад
I have main ac panel ,ac distribution junction box.in ac panel we have main mccb(earth protection) for on-off, Ac distribution Power cable taken from Ac panel main circuit breaker control. Is this needed any separate mccb for ac distributions box .(in ac distribution box we have 30 MCB,30ssr,two controller).
@TimWilborne
@TimWilborne 2 года назад
Yes there is more needed, you need to dig into the NEC book.
@rameshnatarajan5746
@rameshnatarajan5746 2 года назад
@@TimWilborne Thanks for your response.Could you please share authentic links for NEC ,UL508A. Suggest any course are there for ul508a .
@sanjaygurung7623
@sanjaygurung7623 Год назад
Hello, I don’t find wiring diagram on video description
@TimWilborne
@TimWilborne Год назад
You're right, we're revising our website and that link is missing. See if I can get it put back up.
@jhoon6227
@jhoon6227 2 года назад
Hi, I dont see schematics in description to download. Is it removed?
@TimWilborne
@TimWilborne 2 года назад
No, we're moving some links around right now trying to consolidate items, here you go. twcontrols.com/lessons/standard-electrical-control-panel-and-plc-trainer-drawings
@danielsowa8209
@danielsowa8209 3 года назад
I don't see the wiring diagram, I'm still a nube and I like following those for practice. I love this channel though!
@TimWilborne
@TimWilborne 3 года назад
Hi Daniel, they are at the link below. twcontrols.com/lessons/introduction-to-electrical-control-panels-including-plcs-and-hmis
@danielsowa8209
@danielsowa8209 3 года назад
@@TimWilborne Hey, you actually answered! Well I enjoy your videos so I signed up for the first tier of Patreon. Keep up the good work! Thanks for the link too.
@TimWilborne
@TimWilborne 3 года назад
@@danielsowa8209 Thank you for your support!
@Bosanac_99
@Bosanac_99 Год назад
Would products certified only to the UL508a standard be accepted in Canada?
@TimWilborne
@TimWilborne Год назад
There is a Canadian marking for UL 508A. It has a C on the left side of the UL and a US on the right side.
@Bosanac_99
@Bosanac_99 Год назад
@@TimWilborne OK, one more question, please. Would cUL508 certified products be accepted by CSA standards in Canada?
@_stardust__
@_stardust__ 3 года назад
Where can I get that enclosure?
@TimWilborne
@TimWilborne 3 года назад
www.theautomationstore.com/control-panels/
@indian.techsupport
@indian.techsupport 25 дней назад
Din is an acronym which translates to "german industrial norm" which is basically the german iso. There many more din norms than just those rails.
@TimWilborne
@TimWilborne 23 дня назад
Yep, here is a video on DIN rail. ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-7QuITImfDqc.html
@MyRefriedBeans18
@MyRefriedBeans18 Месяц назад
I don't see a grounding lug for the incoming power.
@TimWilborne
@TimWilborne Месяц назад
It's the green thing 🙄 Did you have a question about it?
@pushpakarmishra1441
@pushpakarmishra1441 3 года назад
sir pls make videos over VFDs
@TimWilborne
@TimWilborne 3 года назад
See link below. twcontrols.com/ac-drives-and-3-phase-motors
@fiifinenyi2156
@fiifinenyi2156 2 года назад
please am from Ghana how can I buy a micrologic 1100 or 1000. I have been searching since in my area but can't find one
@TimWilborne
@TimWilborne 2 года назад
The first question is what PLC is popular in your area.
@fiifinenyi2156
@fiifinenyi2156 2 года назад
@@TimWilborne so far in all the company's I worked as an intern they don't use one brand, I have seen Mitsubishi, Siemens, Omron and in my school they use Allen Bradley
@vidzbelikewoah
@vidzbelikewoah 10 месяцев назад
Good afternoon, I’m about to start classes to be a ul 508a Mtr. Do have any advice and recommendations of books I should have? Thanknyou
@TimWilborne
@TimWilborne 10 месяцев назад
Do UL's practice exams. They cover everything you need to pass.
@vidzbelikewoah
@vidzbelikewoah 10 месяцев назад
@@TimWilborne thank you
@TimWilborne
@TimWilborne 10 месяцев назад
Good luck. Definitely don't go into the test blind. It was difficult
@vidzbelikewoah
@vidzbelikewoah 9 месяцев назад
Good afternoon, do you know how I can find the practice exam? I’ve looked on ul website and couldn’t find anything on an practice exam for ul508a
@Munira495
@Munira495 Год назад
Iwant take online course so how to take?
@TimWilborne
@TimWilborne Год назад
Here you go. twcontrols.com/plc-lessons
@jessecastro9717
@jessecastro9717 Год назад
Do you still have classes? Where are you located?
@TimWilborne
@TimWilborne Год назад
Yes in Roanoke Virginia. You can learn more about our training at: twcontrols.com/allen-bradley-plc-training
@khoanguyen4780
@khoanguyen4780 Год назад
what is standard of wire color sir?
@TimWilborne
@TimWilborne Год назад
According to UK standards, ground has to be green. The rest is regional. I have a video coming on this.
@khoanguyen4780
@khoanguyen4780 Год назад
@@TimWilborne I hope to see it soon
@langlymcmanus1194
@langlymcmanus1194 3 года назад
Where's your overcurrent protection (fuses)????
@TimWilborne
@TimWilborne 3 года назад
Uh did you watch the video? There in it...
@langlymcmanus1194
@langlymcmanus1194 3 года назад
I'll answer myself = 15A main CB so motors are group protected. The LVPS must be a self protected type?
@langlymcmanus1194
@langlymcmanus1194 3 года назад
@@TimWilborne I don't see any fuses, nothing rated 5kA but I may be blind. Is there a link to the electrical schematic? Might be a good idea? UL508A requires that the main switch (CB) be able to be switched with door open, I don’t see a handle that allows that? Anyway I subscribed and will check out some other video's. Great response time ... lol
@steadywatching7564
@steadywatching7564 3 года назад
What!? I like the beard.
@Fulzomatic
@Fulzomatic Год назад
Is grounding important? 🤣😂
@TimWilborne
@TimWilborne Год назад
Can you tell I used to work at a place where they didn't think grounding was important 😁
@lefi75
@lefi75 3 года назад
"Does it need a label?" Can you just say yes next time?
@TimWilborne
@TimWilborne 3 года назад
That would be the best answer 😀
@celsiusfahrenheit1176
@celsiusfahrenheit1176 Год назад
Hi Tim, I have a computer science degree and a minor in electronics, I became an electrical contractor while studying. I did an online PLC basics certification. I am thinking of doing the PLC II which covers Rockwell 5000 series, SCADA, DCS etc. My question you you is what else do I need to get enough knowledge and experience to start offering my services for the automation industry specifically, PLCs, scada, MES, and ERP integration?
@TimWilborne
@TimWilborne Год назад
The biggest thing would be opportunities for troubleshooting experience. That will go further than PLC II.
Далее
Получилось у Миланы?😂
00:13
Просмотров 558 тыс.
Sinking and Sourcing PLC Inputs with PNP NPN Sensors
17:31
Troubleshooting a PLC Output
7:25
Просмотров 38 тыс.
Control Panel Testing - Tips and Tricks
5:09
Просмотров 182 тыс.
Electrical Control Panel Wiring in 9 Minutes with KNX
10:05
EB Controls Custom Control Panel Comes to Life
4:36
Просмотров 68 тыс.
Virtual Lunch & Learn: UL 508A Panel Design Practices
44:20
#engineering #diy #amazing #electronic #fyp
0:59
Просмотров 2 млн
Prices & Poco M4 Pro 5G
1:00
Просмотров 272 тыс.