Тёмный

IS This Electrical Installation Tester worth the Hype? - TIS MFT Pro. 

eFIXX
Подписаться 684 тыс.
Просмотров 9 тыс.
50% 1

Is the award-winning Multifunction Electrical Installation Tester really worth the hype? Joe Hammond thoroughly tests the MFT Pro from Test Instrument Solutions to find out.
Learn more about the TIS MFT Pro
👉 hub.efixx.co.uk/TIS-MFTPro
How to test a three-phase EV charger with a TIS MFT PRO & EV-TEST 100
👉 • How to test a three-ph...
===================
Time Stamps ⏱
00:00 Is this tester worthy of its awards?
00:34 The MFT Pro feels great in your hands
00:55 You can use the screen with gloves on
01:23 Very easy to navigate and use
02:04 The tester will spend the day with a tame apprentice 🫣
03:00 A great feature for insulation resistance
03:17 Performing a loop test and check out "Auto Mode"
03:45 Let's check how the apprentice is getting on
04:15 Will the tester work in industrial environments?
04:41 Checking the quality of power on single and three phase systems
05:34 A great feature for inverters and battery storage
06:40 Testing EV chargers with the MFT Pro
08:14 Overall thoughts on the tester
===================
#electricaltesting #mft

Наука

Опубликовано:

 

18 май 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 43   
@efixx
@efixx Месяц назад
Learn more about the TIS MFT Pro 👉 hub.efixx.co.uk/TIS-MFTPro How to test a three-phase EV charger with a TIS MFT PRO & EV-TEST 100 👉 ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-dR9XFyMPH_k.html
@protectiongeek
@protectiongeek Месяц назад
Hmm. Re the power quality checks. You switch the main isolator off, so the effect of any of that load on power quality is removed, surely? Also, if there is no current flowing (as the isolator is open) how can you determine the phase angle between voltage and current to work out power factor? Granted, harmonic analysis tends to only require voltage phasors but, again, if you've just disconnected a chunk of the load by opening the isolator that potentially gives a distorted (forgive the pun) view of the total harmonic distortion, especially if you've disconnected a lot of non-linear loads. Finally, the display on the screen shows cos phi as 1.00 capacitive but the 'pf' as 0.74 - how does that work?
@three-phase562
@three-phase562 Месяц назад
It looked like he had the current clamp around the earth conductor whilst he was measuring, wonder if there is a circulating current confusing the meter? Totally agree that the harmonic measurement should be made with the board loaded. Also did the leakage test a bit later with the isolator off. Guess it is just a sales demo video.
@protectiongeek
@protectiongeek Месяц назад
@@three-phase562 glad I'm not the only one scratching my head over this.
@robboinc1
@robboinc1 Месяц назад
Exactly, we seem to have missed a step simply to illustrate safe isolation
@joehammond6119
@joehammond6119 Месяц назад
Wow, well spotted @protectiongeek Was hoping to get away with this one but I should have known better that nothings gets passed our sharp eyed viewers! 😅 You are right we had the isolator, off, rather annoyingly the site was quite tight on its H & S and wouldn’t allow us to go into the board live. However, after much haranguing and with the H & S officer we were able to get some shots of the power quality analysis albeit a tad rushed! Ref the PF this will be down to me holding the probe and not making a great connection on the terminals. We had a bit of pressure from the site brass, 😂 there was certainly not enough on that board to cause a PF like that 😊. Great though that we are showing the safe isolation and that company’s still have robust procedures in place Thanks again for commenting 💪😊
@protectiongeek
@protectiongeek Месяц назад
@@joehammond6119 thanks for such a candid response Joe. Much appreciated. Sometimes it’s easy to forget when watching vids that other less obvious factors may be influencing production behind the scenes. Thanks for another great vid!
@JoeJoe-sw6zy
@JoeJoe-sw6zy Месяц назад
Thank you for sharing your valuable work experience, I searched for UK electricity installation videos on RU-vid, I have seen many videos without traditional translation, your videos have Chinese translation, I am very grateful to the host🙂👍👍🙏🙏
@Tryingtimes007
@Tryingtimes007 Месяц назад
I’m a Megger MFT 1721 True RMS fan boy, as David Savoury has a TIS, well they must be good 👍
@robboinc1
@robboinc1 Месяц назад
What benefit do you have using the power analyser with load turned off, I guess you put the cover back on and powered back up for that? And your just wanting to show that your locking off before taking covers off?
@tresslerj1985
@tresslerj1985 Месяц назад
Test the RCD at the RCD saves going up and down.
@dangallagher2306
@dangallagher2306 Месяц назад
Certain types of RCDs won't trip at the board
@brianhewitt8618
@brianhewitt8618 Месяц назад
​@@dangallagher2306thats interesting, do you know which types won't trip at the board
@dangallagher2306
@dangallagher2306 Месяц назад
@@brianhewitt8618 Memshield 3 boards
@dangallagher2306
@dangallagher2306 Месяц назад
@@brianhewitt8618 memshield 3
@robboinc1
@robboinc1 Месяц назад
​@dangallagher2306 so I heard but never come across it
@Sparks6078
@Sparks6078 Месяц назад
What IP rating is the unit. We do alot of outside testing. Sometimes in rubbish weather.
@testinstrumentsolutions
@testinstrumentsolutions Месяц назад
IP47 however there’s a few videos on RU-vid one recently where the tester was used outside doing earth electrode testing in the bouncing down rain, we hope this answers your question 👍
@electrician247
@electrician247 Месяц назад
@@testinstrumentsolutions 👀
@mattbeddw
@mattbeddw Месяц назад
How is it detecting leakage when the isolator is off? 5:26
@johnwarwick4105
@johnwarwick4105 Месяц назад
Same way it’s measuring reactive power, true power and power factor with the isolator off 😂think some of the video is incorrect
@mikecumbo7531
@mikecumbo7531 Месяц назад
At times, this guy reminds me of Keith Moon.
@joehammond6119
@joehammond6119 Месяц назад
That’s the oddest one of had 😂😂. I do have a drum set, I’ll throw it at Gary and Gordon next time I see them!😅
@liamdraper447
@liamdraper447 Месяц назад
It’s certainly the most unusual looking MFT
@user-yv2eu5un2g
@user-yv2eu5un2g Месяц назад
I think this intrument is similar to a lot of Italian "HT Instruments" series of multifuncion testers. The 1M $ question is: Who is the original manufacturer of them? Personally, I prefer Metrel instruments
@testinstrumentsolutions
@testinstrumentsolutions 4 дня назад
HT Italia make the instruments as they did for AVO when they made the very first MFT back in the day, however we have a different version of it with our ideas 👍
@twitchlightning8377
@twitchlightning8377 27 дней назад
Seen these on Mark Allinsons channel. He seems to rate them. This video has put me off as the PF values are way off. Also how do you get PQ with the main switch off? Just a rushed sales pitch.
@saabinsanity
@saabinsanity Месяц назад
similar to the old megger cm500
@agj2039
@agj2039 Месяц назад
It looks like Italian Macrotest G3
@markjohnson1106
@markjohnson1106 Месяц назад
That is what it is from ht italia. They are not renowned for their reliability.
@gadgetman36
@gadgetman36 Месяц назад
Is it worth the hype? You are paid to say it is. That's what a paid promotion is on RU-vid.
@TimmyBoja
@TimmyBoja Месяц назад
I dropped it and broke the screen. Can’t find anywhere to replace it. Definitely far too delicate.
@testinstrumentsolutions
@testinstrumentsolutions 4 дня назад
I presume you didn’t ask us who sell the product and have spare screens ?
@TimmyBoja
@TimmyBoja 2 дня назад
@@testinstrumentsolutions They just told me to get a quote from a wholesaler but CEF weren’t interested. Any help would be very much appreciated.
@testinstrumentsolutions
@testinstrumentsolutions 12 часов назад
@@TimmyBoja contact the office on Monday and ask for a quote to repair the screen, we deal with all the major wholesalers not just Cef
@simcax6087
@simcax6087 Месяц назад
That double strap/leash/harness abomination is shows what is the main problem of these type/format of testers.
@leodavis5886
@leodavis5886 Месяц назад
Touch screen, yuck
@testinstrumentsolutions
@testinstrumentsolutions Месяц назад
If we showed you our repair lab full of MFTs with faulty switches you’d change your mind £380 plus vat for a switch or £100 for a screen 👍
Далее
Electricians' Guide: Cable Rating Factors
12:45
Просмотров 19 тыс.
Ботанша от 1 до 11 класса !
28:06
Просмотров 747 тыс.
Quickwire Junction Box Confusion? Get Answers Now!
6:52
How to use a multimeter like a pro, the ultimate guide
12:55
A Beginners Guide To DALI Lighting Controls
9:13
Просмотров 18 тыс.
Understanding Your MFT Tester - Dead Tests
6:52
Просмотров 7 тыс.
Worn out Box tipper repairs
1:10:50
Просмотров 63 тыс.
32A Ring Circuit, Can a 24A Junction box Handle It?
5:26
How about that uh?😎 #sneakers #airpods
0:13
Просмотров 10 млн