Тёмный

L&T make APFC Relay Programming, Configuration & testing करना सीखें 

DRONVEER ELECTRICAL TESTING
Подписаться 13 тыс.
Просмотров 40 тыс.
50% 1

L&T make APFC Relay Programming, Configuration & testing करना सीखें#APFCRELAY #powerfactor#apfcpanel
etasmart apfc relay
Eta smart apfc relay
Etasmart 12R apfc relay
12R eta smart relay
l&t etasmart relay
apfc panel control wiring
apfc panel drawing reading
apfc panel wiring explain
apfc control panel wiring explain in hindi
automatic Power factor correction relay
automatic Power factor control relay
power factor relay testing
power factor relay setting
power factor relay programming
APFC Relay Programming
APFC Relay testing
APFC Relay setting
capacitor bank
capacitor panel
APFC panel
capacitor bank mounting
what is power factor
what is APFC Relay
use of APFC Relay
use of power factor relay
use of APFC panel
use of power factor relay
working of power factor relay in auto mode
how to work in Auto Manual power factor relay
what is ck value in power factor relay
what is ck
calculation of ck value
calculation of ck value in power factor panel
how to maintain power factor in factory
how to use industrial capacitor
what is apfc panel?
APFC stands for auto power factor correction panel . It is used to improve power factor to meet the current requirement , to reduce the billing and also to improve feeder voltage regulation.
In industry most of the load is inductive in nature which results in lagging power factor that is why there is loss and wastage of energy which results in high power bills and heavy penalties from electricity boards. If the load is uneven it is very difficult to maintain unity power factor. To overcome this difficulty APFC panel is used which maintains unity P.F
Note:- ये वीडियो education Purpose के लिए बनायी गयी है
#dronveer
यदि आप इलेक्ट्रिकल पैनल की ड्राइंग Reading टेस्टिंग कैसे करते हैंं उसके बार जानकारी लेना चाहते हैं तो चैनल को सब्सक्राइब करें
अपने दोस्तों में व्हाट्सएप ग्रुप में फेसबुक ग्रुप मेंं जहां भी हो सके शेयर जरूर करें!
Star Delta Starter Testing Video
• Star Delta Starter Tes...
AE9000 BM CONFIGURATION
• AE MAKE AE9000 BM MFM ...
L&T ACB WIRING/WORKING
• Working of Air Circuit...
RDOL STARTER WIRING/WORKING
• Special Video for tech...
STAR DELTA STARTER WIRING/WORKING
• Learn Star Delta Start...
DOL STARTER WIRING/WORKING
• Learn DOL Starter Cont...
SIEMENS 7SR10 Relay Programming/Setting/Configuration
• #7SR10SIEMENS #Overcur...
ATS STARTER WIRING AND WORKING
• ATS STARTER WIRING & W...
L&T WL4405 MFM SETTING
• L&T WL4405 MFM Setting...
50 electrical full form- • Full form electrical e...
Star delta starter wiring Video
• Learn Star Delta Start...
Soft starter SLD - • How to read Soft Start...
L&T make GIC TIMER • How to program L&T GIC...
RISHABH MAKE RISH DELTA ENERGY
• HOW TO PROGRAM RISH DE...
Instagram - www.instagram....
star-delta- • STAR DELTA STARTER CON...
R-DOL - • How to read R-DOL STAR...
Scheinder MFM- • Programming, Setting &...
SPEEDOMETER/TECHOMETER- • #SCHEINDER #VFD #dron ...
FACEBOOK ID - / dron.veer.5
Mail ID- banerjidron@gmail.com
CREATE BY DRONVEER
SUGGEST BY friends

Опубликовано:

 

16 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 50   
@chiragchaudhari5031
@chiragchaudhari5031 2 года назад
thanku sir for this relay detail explaination
@agastianbandi
@agastianbandi 9 месяцев назад
Sir gud morning. Sir app ka Apfc relay ka bahuth achha demo diya sir It is very useful to me Tq u
@dronveer_testing
@dronveer_testing 9 месяцев назад
Thank you
@rajivkumar-2389
@rajivkumar-2389 Год назад
Sar yadi Koi load Nahin Hai To Kya power factor panel ko off kar de, ya auto Mein Rahane de ya mannual mai kar de
@dronveer_testing
@dronveer_testing Год назад
PF panel ko band nahi karna hai load aa gaya to or aapne pf panel on karna bhul gaye to dikkat aa sakti hai panel ko on rahne to auto mode mai
@chiragchaudhari5031
@chiragchaudhari5031 2 года назад
if possible please make a video on abb make apfc relay rvc modal
@uttamkumarbarik4937
@uttamkumarbarik4937 2 года назад
thanks for this video. Can you give us this panel schematic wiring diagram in pdf format?
@dronveer_testing
@dronveer_testing 2 года назад
Sorry for this Sir It company property If any support I help you
@satya-bk2fq
@satya-bk2fq 2 года назад
No Wiring diagram available, There is same relay as faulty need to replace and program the same.
@jeevajeevan2038
@jeevajeevan2038 Год назад
Pls Reply 😇 Hlo ji.. Saare Equipment's ON honeke baad 50A taak jaa rahi hai.. Per jese Capacitor Bank ON hoga 115A to 120A tak jaa rahi hai load.. Problem kya ho sakti hai..?
@aakashwaniindore1870
@aakashwaniindore1870 Год назад
is this relay repairable? We have one relay which is giving ITHD alarm and RMS voltage showing 0.
@dronveer_testing
@dronveer_testing Год назад
Contact L&T SERVICE CENTRE
@visions4059
@visions4059 Год назад
Sir OCOM alarm dekha raha hai please kya Karu reply dijia urgent sir🙏🙏
@satishtak8950
@satishtak8950 2 месяца назад
Auto mode work nhi kr rha kay problem ho skta h
@dronveer_testing
@dronveer_testing 2 месяца назад
Please check relay configuration
@Prana.umre16
@Prana.umre16 7 месяцев назад
Alarm status q nahi ja Raha h waha se.?
@dronveer_testing
@dronveer_testing 7 месяцев назад
Jab load chalta hai alarm chala jata hai
@satya-bk2fq
@satya-bk2fq 2 года назад
Hi, What's service charge to replace of faulty 8 step 1ct apfc relay.
@dronveer_testing
@dronveer_testing 2 года назад
Which location Sir
@wondersky6511
@wondersky6511 Год назад
Bhai alarm to nahi Gaya.. alarm band karke dikhao
@dronveer_testing
@dronveer_testing Год назад
Alarm kya hai
@jaiparkashvashist
@jaiparkashvashist Год назад
But sir UNDCAlarm is blowing ,how to remove this
@dronveer_testing
@dronveer_testing Год назад
Under current Alarm after desable remove if you have not required under current protection
@dhirendramishra3270
@dhirendramishra3270 Год назад
Undc alarm aa rha hai to kaise sahi kare
@dronveer_testing
@dronveer_testing Год назад
Under current alarm hai If you hai not required Under current protection Please desable
@varunkumar3253
@varunkumar3253 Год назад
Our apfc 14 R shows UNDC and No PF is displaying how to rectify that sir
@dronveer_testing
@dronveer_testing Год назад
UNDC IS UNDER CURRENT ALARM
@dronveer_testing
@dronveer_testing Год назад
Please check ct wiring
@rsahucreation9291
@rsahucreation9291 Год назад
UNDC alaram dikha ra he auto me on nehi horaha he
@dronveer_testing
@dronveer_testing Год назад
Under current hai aapka system
@saurabhsaini2474
@saurabhsaini2474 2 года назад
sir relay automatic capacitor nahi laga rahi h to karna h
@dronveer_testing
@dronveer_testing 2 года назад
Aap relay se Manually kar rahe hai ya CT SENSING ke through kar rahe hai Please check supply on terminal no. C1
@saurabhsaini2474
@saurabhsaini2474 2 года назад
sir CT ke through hi chal rahi thi relay but do din se auto mein nahin chal rahi hai manually lagane pad rahe hain
@dronveer_testing
@dronveer_testing 2 года назад
Contact to L& T service engineer
@akshayr2287
@akshayr2287 Год назад
admin password kya hai bro
@dronveer_testing
@dronveer_testing Год назад
Pass 0000
@abhimanyukumar6283
@abhimanyukumar6283 Год назад
Sir password set kaise kiya jata hai Please bataiye
@sarojkumarpradhan1917
@sarojkumarpradhan1917 2 года назад
Sound not clear
@dronveer_testing
@dronveer_testing 2 года назад
Try to make new next time with clear sound
@kumarbiplab4948
@kumarbiplab4948 2 года назад
Bhai BCH EOCR ka programing dikhao
@dronveer_testing
@dronveer_testing 2 года назад
Ok bhai
@dronveer_testing
@dronveer_testing 2 года назад
ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-t78bd-GDbSk.html BCH BOCR VIDEO
@pritikhatake6844
@pritikhatake6844 6 месяцев назад
Alarm to band nahi huva
@dronveer_testing
@dronveer_testing 6 месяцев назад
Alarm under current ka hai Jab minimum 10% load ke baad alarm hat jata hai
@rajivkumar-2389
@rajivkumar-2389 Год назад
Sir, company ka sara load off karne ke baad relay mai UNDC Alarm aa jaata hai, why, or PF 0.23C aa jaata hai, sir please tell me
@dronveer_testing
@dronveer_testing Год назад
Under current Alarm hai Sir Or jab load ( current kam hoga) nahi hoga to PF without current esa he hota hai
@rajivkumar-2389
@rajivkumar-2389 Год назад
Sir, is taraha se koi nuksaan to nahi hai
@dronveer_testing
@dronveer_testing Год назад
@@rajivkumar-2389 isme nukshan kyu hoga jab koi load he nahi hai PF kaise ayega Aapke kWh meter mai load to nahi hai na bill to vanhi se banta hai
@rajivkumar-2389
@rajivkumar-2389 Год назад
Sir jab morning mai load on karte hai to pf -0. 93 C ho jata hai or alarm OCMO aa jata hai. Fir pf pannel ko off kare on karte hai to pir pf ok chalta hai
@rajivkumar-2389
@rajivkumar-2389 Год назад
Alarm OCOM aa jata hai
Далее
Holding Bigger And Bigger Dogs
00:18
Просмотров 16 млн
Capacitor Bank ( KVAR) calculation Formula
12:07
Просмотров 27 тыс.
APFC, L & T, etaULTRA 16R
8:47
Просмотров 15 тыс.
Circuit drawing for APFC panel
17:32
Просмотров 22 тыс.