Тёмный

Lenze Servo Drive EVS 93XX Bench Testing Part 1 

EngrSajidRehman
Подписаться 15 тыс.
Просмотров 38 тыс.
50% 1

Опубликовано:

 

22 окт 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 23   
@VictorHernandez-pr7lb
@VictorHernandez-pr7lb 3 года назад
Hi Mr EngSajidRechman: We need test EVS9326-EVS004 drive by LENZE. Can you add parameters settings for test it as you show ??
@behzadbahrami4628
@behzadbahrami4628 4 года назад
Hello Sir , There is a global servo 9300 here , It is working under Can bus connection .It doesnt work proberly , The HMI secreen fault shows Inverter is not ready , Everything seems ok .I dont know why it doesnt work .By the way I want to change start's source as digital terminal , But frequence's source from another driver's out put or from Can bus . Could u please tell me which code is for turning Can Bus off?? And which one is for setting Start from terminal??
@theinel
@theinel 5 месяцев назад
can we test it without resolver or open loop
@muhtasimfuadhimu2893
@muhtasimfuadhimu2893 Год назад
Can i Run any motor with this drive without any speed feedback? Please kindly help Note: We have 9324-ES servo drive
@engrsajidrehman
@engrsajidrehman Год назад
Yes! As explained in video you can run any motor specially those which are available in motor data of 93xx control card, on bench test . While adding a default basic motor parameters and Settings given in video you can run any motor without feedback ( resolver or encoder)
@stefan4582
@stefan4582 6 лет назад
Thankss ;) I have done that but now I have Sd2 Trip
@engrsajidrehman
@engrsajidrehman 5 лет назад
Sorry for this much late reply... STEFAN that step is mentioned in the Video... also in the document of the procedure..
@stefan4582
@stefan4582 6 лет назад
I have problem with my lenze evs9322. I have machine for labeling on bottels. On the lenze are 2 encoders... All of my parameters have been deleted. Now I found the other inverter with all parameters like on my machine.. now I want to go with my computer and get all parameters from new one( i found) and i want to put to old inverter(without parameters)... How can i connect computer and what software i need to do that... please help me....
@engrsajidrehman
@engrsajidrehman 6 лет назад
You can use Global Drive Control (GDC) to Upload and Download the Parameters To/From Lenze Drive. GDC is available on the following link. plc.myforum.ro/lenze-global-drive-control-version-414-vt4331.html drive.google.com/open?id=1cEXE_q35sdAAK8NTdoUuiEzAB2zHugdb Video Help: ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-Qo4DXJZo1oc.html Follow this video for details. although its 8200 but it will give you the idea for connection b/w GDC and PC.
@janaracaonakkicu9484
@janaracaonakkicu9484 4 года назад
Hellow sir. When i power on Lenze EVF9323 vfd "PI TRIP" message show on the display. I can't remove it and run the vfd. So sir plz tell me the solution. Plz sir.
@engrsajidrehman
@engrsajidrehman 4 года назад
If you have a Backup of Drive Parameters or written Parameters somewhere, then after Re-parameterising the Drive, the issue will be resolve. but if even after RESET the Drive you get the same Error then it means there is some issue in Control Card. You have to replace the Control Card with the proper functioning Card to diagnose the issue.
@erivanarriaga6338
@erivanarriaga6338 5 лет назад
Hi Dude, do you know when I can get the document that you show in your video?
@engrsajidrehman
@engrsajidrehman 5 лет назад
Its link is already given in description of the video
@theinel
@theinel 5 месяцев назад
@@engrsajidrehman Sorry but the link doesn't work, any other option?
@veerendraacharya1304
@veerendraacharya1304 5 лет назад
I have problem in my lenze evs9325 es without control and speed signal drive output will start and motor running always
@engrsajidrehman
@engrsajidrehman 5 лет назад
is the drive install on the machine or you are checking it in the lab? If you have proper parameters for the same drive, try to reset the drive (Factory Settings) and then put the parameters in drive again and check the behavior. it should work properly, but if the drive still gives the output on just powering it up, then you have to check the Hardware inside the drive (PCB and other circuits)
@engrsajidrehman
@engrsajidrehman 5 лет назад
You have to check the following Parameters of Drive Control Card (By SWAPPING with the OK Drive) On PCB level need to check the Firing Circuit of the Drive
@badshakhan667
@badshakhan667 4 года назад
Hello brother please help Lenze evs9325 terminal mode run... Not communication Please help me terminal mode run
@engrsajidrehman
@engrsajidrehman 4 года назад
In a video, I explained the Terminal Mode if you watch closely. The connection diagram is given in the video description.
@DaSarahGFan
@DaSarahGFan 3 года назад
Gameboy in servo fu
Далее
Lenze Global Drive Control
9:41
Просмотров 37 тыс.
Lenze 9300 Lecom
7:47
Просмотров 10 тыс.
Lenze Servo Drive EVS 93XX Bench Testing Part 2
3:47
AC Servo-8 Drive Hardware شرح السيرفو
14:36
Measuring conducted emissions with LISN
19:44
Просмотров 1,1 млн
Lenze 9300 Keypad
3:04
Просмотров 21 тыс.