Liebert GXT3 UPS Start UP 

Tim Driscoll
Подписаться 146
Просмотров 49 тыс.
50% 1

Basic Liebert GXT3 UPS Start UP

Опубликовано:

 

15 окт 2012

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 28   
@jokeefeca
@jokeefeca 4 месяца назад
I just bought a refurbished Liebert GXT3. Your video helped me so much!! Many Thanks!!
@DHoberer
@DHoberer 10 лет назад
Thank you so much for this video. I have just inherited many of these in a new job and didn't understand how to do the shutdown routine. You're a great help!!!
@cj82fast4u
@cj82fast4u 11 лет назад
good tutorial! straight and to the point!
@kaienglee5319
@kaienglee5319 8 лет назад
good tutorial. I learnt how to kill the UPS from the front panel....
@phewson8907
@phewson8907 9 лет назад
You're a saint
@carlosalbertomartinez2526
@carlosalbertomartinez2526 4 года назад
nice vid
@ZoranAUS
@ZoranAUS 10 лет назад
Just scored one of these from eBay so this vid was a great help (plus i didnt feel like reading the manual :))
@luismorgadosanz397
@luismorgadosanz397 8 лет назад
Hello , I have a UPS. 5110 and recently was light , I began to make beeps and I guess this downloaded. my question is ... how loaded normally? I leave it connected and off for how long?
@edwardb1075
@edwardb1075 8 лет назад
Can you start this unit with just the batteries, without being plugged into AC?
@tcarr925
@tcarr925 7 лет назад
Yes the GXT3 is cold start capable.
@yaksongs
@yaksongs 8 лет назад
Hi Tim - have you ever tried to replace the fan in one of these? I have one but its way too loud for my studio, so I have changed the fan to a similar spec virtually silent model, however the unit doesn't like it & basically whilst the fan spins ok, the alarm comes on after a few seconds & the unit displays an error light :( - same voltage & spin rate fan, although I noted that the Amp rate was different 0.7 for the factory one whereas the new one (a Be Quiet silent wings fan) is 0.2A . I have googled & seen on forums others saying that the GXT2 copes with a fan change, but not this model. :'( Any thoughts you may have very welcome :)
@timd32
@timd32 8 лет назад
have not tried that. but I did have one unit let the smoke out last week on the bench and I looked at the fan when I had the cover off. As long as the fan is blowing the correct direction maybe they have a current monitor on the fan amperage? so a less powerful fan would draw less and alarm on some sort of fan failure?
@godfreythorpe6692
@godfreythorpe6692 6 лет назад
Hi can you replace the batteries in a GXT3-3000va unit when it is By Pass mode so I don't have to shut it down or do I have to totally shut it down
@timd32
@timd32 6 лет назад
Yes, have done that many times in just Bypass.
@godfreythorpe6692
@godfreythorpe6692 6 лет назад
Tim when I change batteries in a GXT3-300va UPS do I have to wear rubber gloves and can I get a shock from it
@timd32
@timd32 5 лет назад
My notifications were sent to spam, You wont get a shock from the battery per say, but just take your time and track the wires when you pull then off. The older ones have a metal case, the not so old ones have a plastic case holding the batteries. A while back the GTX3 has been replaced by the GTX4 which seems pretty nice we have set up a few of those.
@timd32
@timd32 5 лет назад
Yep sure can.
@stephenmitchell4393
@stephenmitchell4393 8 лет назад
is it possible to convert the gxt33000rt120from 120v to 230 v input? I have a generator for off grid power but can not pull a single leg 120 off. only 230 v ? thanks
@timd32
@timd32 8 лет назад
+Stephen Mitchell input power appears to be fixed, there is no switch on the back of the unit like a dual rated supply would have. Manual also only lists 90-140 as the range for that unit.
@carlobn139
@carlobn139 3 года назад
Cuanto pesa el equipo lo dedo traer desde USA
@servicompu312
@servicompu312 2 года назад
Buen dia como estas. tengo un Ups Liebert gxt3 pero se fue la energia electrica y se consumio toda la carga de las baterias. realice el cambio de las baterias por unas con carga full de otro Ups pero el mismo no enciende, me ayudan con algun reset o algo. gracias y Saludos.
@timd32
@timd32 2 года назад
check the battery connection cables are hooked up. check the switch in the back is ON. With the cord plugged in there will be a Green LED on front bottom. and you should have battery bars across the top. if no alarms should be able to push the straight line button on Left. if you have alarms what are you seeing for the battery bars. thanks from Google Translate I was told this works pretty well... compruebe que los cables de conexión de la batería estén conectados. compruebe que el interruptor en la parte posterior esté ENCENDIDO. Con el cable enchufado, habrá un LED verde en la parte inferior delantera. y debería tener barras de batería en la parte superior. si no hay alarmas, debe poder presionar el botón de línea recta a la izquierda. Si tiene alarmas, ¿qué está viendo en las barras de la batería?
@luisx3456
@luisx3456 3 года назад
the 1000va how much W deliver ? its the same fan noise ?
@timd32
@timd32 3 года назад
900W, looks like the same fan from what I can tell, I don't have one to compare. But the rear view looks the same cage set up.
@timd32
@timd32 3 года назад
Actually found some specs. The 3000 might be a little quieter if you can call it that. 3000RT>
@juanmedinavasquez4660
@juanmedinavasquez4660 6 лет назад
No entiendo yo soy Chileno en español porfavor, gracias
Далее
UPS Emerson GXT3
5:37
Просмотров 14 тыс.
Получилось у Миланы?😂
00:13
Просмотров 774 тыс.
Ford Focus Axle Seal Installer
1:50
Просмотров 3,3 тыс.
Generate  Free Electricity 240 Volts On Glass 100% Real
23:35
Bumili Ako ng 2024 Honda CB650R E-Clutch
13:09
Просмотров 41 тыс.
Revisión UPS Vertiv 3 KVA Parte 1   HD 720p
26:30
Просмотров 4,3 тыс.
Smoke alarm test.
1:19
Просмотров 3,2 тыс.
2003 Ford Focus Axle Seal Install
1:52
Просмотров 3,7 тыс.
Получилось у Миланы?😂
00:13
Просмотров 774 тыс.