Тёмный

Live fault finding #11 - faulty spark generator Ideal Icos 

CP Utility Solutions
Подписаться 11 тыс.
Просмотров 12 тыс.
50% 1

DISCLAIMER:
This video is only intended for use by qualified Gas Safe Registered engineers. You must not attempt any work on your boiler if you are not qualified. You must always carry out 26.9 checks upon completion of works on a boiler.
~
The spark plug tester can be bought from eBay in case anyone is interested in getting one for their toolbag.

Опубликовано:

 

2 окт 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 33   
@experienceb4bob
@experienceb4bob Год назад
Very informative and helpful video... specially the spark electrodes tester...thanks for taking out time and making videos which help everyone out there including me.
@cputilitysolutions
@cputilitysolutions Год назад
Glad you found it helpful 👍🏽
@illuminate06
@illuminate06 6 месяцев назад
0:08 do the ideal icos go into service mode, max and min fire?
@cputilitysolutions
@cputilitysolutions 6 месяцев назад
No, you just adjust it via the potentiometer
@mujibrahman212
@mujibrahman212 Месяц назад
Been watching your videos, even the old ones, very helpful!! Do you have a link for the spark electrode tester also is it universal and can use in most boilers?
@javediqbal1343
@javediqbal1343 2 года назад
Nice and very informative video. Thanks
@aminsajawal3935
@aminsajawal3935 2 года назад
Top man. Great job 👏🏻
@colinfleming2244
@colinfleming2244 Год назад
They spark plug testers think come in pack of 4 you will need them keep breaking on me. On vals usually and not always accurate. Had one good spark lit boiler didn't stay on ended up being lead. Lead needs about 1kohm resistance
@cputilitysolutions
@cputilitysolutions Год назад
Nice one
@tomekwrobelek9233
@tomekwrobelek9233 Год назад
Great professional job, I like your magnetic wrist band 😉 Could you please tell me where did you get the spark tester , Thanks
@kevj1964
@kevj1964 2 года назад
good vid
@tomekwrobelek9233
@tomekwrobelek9233 Год назад
Okay got now the spark tester from eBay Thanks
@jasonwhittle5008
@jasonwhittle5008 2 года назад
Good job pal 👍😎
@rimvydasr2166
@rimvydasr2166 10 месяцев назад
Hello I have qwestion if boiler working great to heat water in bath. But working only 1 min on radiotor and stops and show error L F. What's can be? Is was clean thermostat was change sensor with can see then boiler is burning.
@abdulh63
@abdulh63 2 года назад
Another great video. Thank you
@dazl7954
@dazl7954 2 года назад
cool video, not a bad breakdown call at all :)
@jamesn8932
@jamesn8932 2 года назад
Thanks great video. Work on alot of these. Ordered a spark plug tester to help me out. 👍
@cputilitysolutions
@cputilitysolutions 2 года назад
Nice one!
@azimkhan9862
@azimkhan9862 Год назад
You are very good
@brianmayne6513
@brianmayne6513 2 года назад
Another good video
@cfgman1
@cfgman1 Год назад
Watch your videos they are usually spot on ....love the magnetic arm band must get one !
@cputilitysolutions
@cputilitysolutions Год назад
Glad you like them!
@paulhotson5820
@paulhotson5820 Год назад
You saved my boiler thanks so much ❤️
@cputilitysolutions
@cputilitysolutions Год назад
Thank you! Hope you subscribed! 😉
@paulhotson5820
@paulhotson5820 Год назад
@@cputilitysolutions Hi,it heated up fine had a bath and shower then after two or so hours went back to FL code again. It's getting a good spark as I checked with elec tester like yours,I also removed and cleaned probs, condenser trap. The flow goes through the roof straight up and is capped to stop any debris from getting in. Gas cooker has good supply of Gas. Is there anything else to check, I'm at a loss many thanks?
@cputilitysolutions
@cputilitysolutions Год назад
The FL code is quite a generic code and could mean a number of things. It may need stripping back to inspect the burner too. Could also be a sticking gas valve
@paulhotson5820
@paulhotson5820 Год назад
@@cputilitysolutions Removed fan and cleaned burner still no joy, How do you unstick the gas valve ?
@paulhotson5820
@paulhotson5820 Год назад
@@cputilitysolutions local engineer checked boiler today and thought the generator was at fault but after checking old one witch was dead and refitting new one it "sparked" into life... Must have been a dirty connection, anyway thanks for all your help!!! New sub.
@stewartharrod1706
@stewartharrod1706 2 года назад
Nice work 💪
@cputilitysolutions
@cputilitysolutions 2 года назад
Thanks man 👍🏽
@jockster5525
@jockster5525 Год назад
Dreadful boilers... thanks for your efforts
@cputilitysolutions
@cputilitysolutions Год назад
Absolutely - most of the ones I come across now have split main heat exchangers!
Далее
How to test the spark generator on a Baxi boiler
7:04
🦊🔥
00:16
Просмотров 396 тыс.
Boiler Faults Find Most in 5
14:08
Просмотров 2,6 тыс.
Live Fault Finding #13 - faulty 3 port valve
18:13
Просмотров 10 тыс.
L2 fault ideal logic (detection electrode)
8:58
Просмотров 3,7 тыс.
Live Fault Finding #14 - No Hot Water
4:40
Просмотров 7 тыс.
Live Fault Finding #15 - Faulty Hall Effect Sensor
5:17