Reactive power is a concept in electrical engineering that refers to the portion of electrical power in an alternating current (AC) circuit that does not perform useful work but is necessary for the operation of certain electrical devices and the overall stability of the electrical grid. It is expressed in units called volt-amperes reactive (VAR).
In an AC circuit, electrical power consists of two components:
Active Power (Real Power): This is the portion of power that performs useful work, such as powering appliances, lighting, motors, and other devices. It is measured in watts (W).
Reactive Power: This is the portion of power that does not do useful work but is required to maintain voltage levels and enable the operation of inductive loads like electric motors, transformers, and fluorescent lighting. It is measured in volt-amperes reactive (VAR).
Reactive power arises primarily due to the phase difference between the voltage and current waveforms in an AC circuit. In AC circuits with inductive or capacitive components, the voltage and current waveforms can be out of phase with each other. When voltage and current are out of phase, reactive power is needed to establish and maintain the electromagnetic fields associated with these components.
Utilities and power systems must carefully manage reactive power to maintain voltage stability and ensure the reliable operation of the electrical grid. They often use devices like capacitors and inductors, called power factor correction devices, to help balance the reactive power in the system and improve power factor, which is a measure of how efficiently electrical power is being converted into useful work.
In summary, reactive power is the non-working component of electrical power in an AC circuit that is required for the proper functioning of inductive loads and the stability of the electrical grid. It is measured in volt-amperes reactive (VAR) and is distinct from active power, which performs useful work.
Reactive power is a concept in electrical engineering that refers to the portion of electrical power in an alternating current (AC) circuit that does not perform useful work but is necessary for the operation of certain electrical devices and the overall stability of the electrical grid. It is expressed in units called volt-amperes reactive (VAR).
In an AC circuit, electrical power consists of two components:
Active Power (Real Power): This is the portion of power that performs useful work, such as powering appliances, lighting, motors, and other devices. It is measured in watts (W).
Reactive Power: This is the portion of power that does not do useful work but is required to maintain voltage levels and enable the operation of inductive loads like electric motors, transformers, and fluorescent lighting. It is measured in volt-amperes reactive (VAR).
Reactive power arises primarily due to the phase difference between the voltage and current waveforms in an AC circuit. In AC circuits with inductive or capacitive components, the voltage and current waveforms can be out of phase with each other. When voltage and current are out of phase, reactive power is needed to establish and maintain the electromagnetic fields associated with these components.
Utilities and power systems must carefully manage reactive power to maintain voltage stability and ensure the reliable operation of the electrical grid. They often use devices like capacitors and inductors, called power factor correction devices, to help balance the reactive power in the system and improve power factor, which is a measure of how efficiently electrical power is being converted into useful work.
In summary, reactive power is the non-working component of electrical power in an AC circuit that is required for the proper functioning of inductive loads and the stability of the electrical grid. It is measured in volt-amperes reactive (VAR) and is distinct from active power, which performs useful work.
who to add real power and reactive power,what is reactive power tamil,reactive power tamil,how to understand reactive power,what is effect of reactive power,reactive power endral enna,simple way to study about reactive power,easy way to study about reactive power,why reactive power is wastage in system,capacitor basics tamil,inductors tamil,capacitors tamil,easy way to study about apparent power,how to calculated apparent power,how to add watt and var
who to add real power and reactive power,what is reactive power tamil,reactive power tamil,how to understand reactive power,what is effect of reactive power,reactive power endral enna,simple way to study about reactive power,easy way to study about reactive power,why reactive power is wastage in system,capacitor basics tamil,inductors tamil,capacitors tamil,easy way to study about apparent power,how to calculated apparent power,how to add watt and var

Опубликовано:

 

6 сен 2023

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 7   
@rasheedahamed8133
@rasheedahamed8133 2 месяца назад
Nice explanation
@techemaster6459
@techemaster6459 Месяц назад
Thanks for liking
@jinistusantony1182
@jinistusantony1182 9 месяцев назад
Super bro
@castrot.s8704
@castrot.s8704 3 месяца назад
Super bro. Neenga thaan correct ah sollirukkinga
@techemaster6459
@techemaster6459 3 месяца назад
Let me know if you want the video on any other concepts
@MaheshKumar-cu3rt
@MaheshKumar-cu3rt 11 месяцев назад
Thank you sir
@techemaster6459
@techemaster6459 10 месяцев назад
Welcome
Далее
Where does the Reactive Power go? TheElectricalGuy
11:09
What is a CT Burden ? Explained | TheElectricalGuy
11:59
What is a Boost converter??? - In Tamil
10:54
Просмотров 26 тыс.