@Darknecros7
@Darknecros7 Год назад
There’s just something I like about these Geiger counters that have the analog gauge on them, and the audible noise is a must.
@cryfry2
@cryfry2 Месяц назад
thats pretty darn cool
@S0N1Cua
@S0N1Cua 3 года назад
Eberline E-520 same idea but it is actually disables external probe when x1000 selected, which probably could be useful when you are trying to measure 2 R/h :)
@jamesluck2969
@jamesluck2969 3 года назад
I cant speak for the modern 14c or its variants, but my older 14c disables the internal when its below the highest range and in reverse disables the external when on the high range. You wouldnt be able to trust the readings of either your external or internal probe if it was the case you mention.
@S0N1Cua
@S0N1Cua 3 года назад
@@jamesluck2969 yes, when 14C switched to x1000 range it disables counting but HV is still present at external connector, with E-520 there's no counting and no HV when internal tube range is selected: ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-q6M9AxuteHA.html
@radiumquetzal8000
@radiumquetzal8000 4 года назад
Nice demonstration of the Ludlum! But why the gloves? :)
@WheelerScientific
@WheelerScientific 4 года назад
People tend to post lots of comment when I don’t wear gloves so, to save my trouble I just threw them on.
@radiumquetzal8000
@radiumquetzal8000 4 года назад
@@WheelerScientific Ah smart, radiophobes tend to complain a lot.
@WheelerScientific
@WheelerScientific 4 года назад
@@radiumquetzal8000 Yes, yes they do.
@RatKindler
@RatKindler 3 года назад
I just watched an emergency services training video that said that anything above 300 c/min is contaminated. You might want to get out of that room. :-)
@WheelerScientific
@WheelerScientific 3 года назад
Well it hugely depends on what probe is being used, here is an ultra sensitive gamma scintillator, compared to what most what most emergency services use is a many many less sensitive Geiger muller device, :-)
Далее
Ludlum Model 3 Operational Check & Individual Survey
16:03
Model 14C-RK Training Video
22:12
Просмотров 10 тыс.
Which Geiger Counter to Buy?
37:27
Просмотров 200 тыс.
Time to get a Geiger Counter!
18:54
Просмотров 124 тыс.
Overview of the Ludlum Model 44-9 GM Detector
6:53
Просмотров 15 тыс.
Ludlum Radiation Detectors
14:22
Просмотров 9 тыс.
Cheap Geiger Counters on Amazon - Only 1 is Worth it!
24:27
Measuring conducted emissions with LISN
19:44
Просмотров 1,1 млн
Model 2241-3RK2 Response Kit Quick Start Guide
4:17
Просмотров 2,1 тыс.
How to use a Geiger Counter
7:17
Просмотров 85 тыс.
Model 3 Overview
4:31
Просмотров 24 тыс.