Sir sr106 ki jagah or konsa diode laga sakte h sath hi isme lage smd diode kharab hone par konse transistor laga sakte h ye smd transistor kaha se milege please bataye thanks
Thanks sir .same modle ka invetor hai mains pe theek chalta he but bettery pe nhi chalta hai.pl. sir help me ager mosfet khrab ho tou mains pe set chal sakta he ya nahi .pl.sir tell me about this problem.
Jo diode aapne change kya hai uska number kya hai aur PCB barar nikalkr repair k samay PCB k aise koi jagah hai jaha hath lagnese 220 volt ka jhotka lagne ki chance hai.
Bhai ji aapka number chiye mera inverter ko 3 saal hogaye hai usme overload aur batry low aur beep ki problam aagyi thi batry to check karwai thi thik hai batry too mistri ke leker gya tha usne whi plate repair kardi aur bol rha hai ki new plate hai wo zidd kr rha hai ki company se hi aati hai aisi plate main soch rha hu ki paise to lage ge hi kyu na media bula liya jaye humming blast hogya tha inverter ka mere samne hi maine khud dekha tha abb usme 2 humming hi hai jo bade size ke hote hai maine photo bhi li hui hai plate ki microtek inverter eb 900 abb kya kiya jaye company ka jaloos nikala jaye ya uska. Ek baar aap bhi dekh lena plate ki photo number rply kr dena bhai ji Emergency hai bhai ji rply kro
Sir mere pass 24 volt 30 amp ka battery charger hai ,usme FGH 35N60 OR 10 ohm 15watt ka load resistance khharab ho gya tha ,jise me Badale diya tha 35N60 ki jagah 40n60 laga diya tha ,but power on karne on par power Aur Ho Jata Hai but output mein battery Lagate Rahe 40n60 aur 15 ohm ka registration kharab ho jata hai,pls help
Sir mera bhi luminous ka inverter hai EcoVolt+750 kl maine ghr main drill ka use kiya tha us jis point pr drill lagayi thi or point inverter pr tha, magar us time main light aa rahi thi. Ab problem ye hai k mera inverter kl sey he red light(low battery) show kr rahai hai is kya karan hai or SOLUTION kya hai?
जय श्री राम सर क्या कीसी 850वाट के सेट में 2 मॉस्फेट लगे होने के बाद उसमें 1,1 मॉस्फेट बढ़ा सकते हैं ।अगर हां तो कोई फाल्ट तो नही होगा। कृपया कोई सुझाव देने की कृपा करें।।
Hello bhai mere pass luminous 850eco watt inverter hai jo ki computer chlane per 30m k baad overload or battery low dekar bnd ho jata hai, Iska fan charging time he chalta hai backup time nahi chalta hai yeh bhi issu ho sakta hai kiunki inverter heat bhut hota hai backup time pe, replay jroor karna bhai, thanks
Sir mere pass eco watt 650i model hai or sir usme backup mode par over load ki problem aa rahi hai bus baaki okk hai pls sir kuch solution bataye vaise mene bina dc lagaye drive par chek kiya to sab 500 600 ke aas pass reading show kar rahe hai sir pls bataye
Sir ji namaste eco 650va invartar ke masfet Cheng kiye hay draive 3.60 aur 14.60 aa gayi sab kuchh Sahi chal rha hay lekin out put 200volt de raha hay kya usme kya check karu help me
i am using a mppt solar charge controller and i want to disable grid charging feature by adding a switch. how can do this please suggest ( inverter exide 850va ) please upload a video
Sir mere pass 24 volt 30 amp ka battery charger hai ,usme FGH 35N60 OR 10 ohm 15watt ka load resistance khharab ho gya tha ,jise me Badale diya tha 35N60 ki jagah 40n60 laga diya tha ,but power on karne on par power Aur Ho Jata Hai but output mein battery Lagate Rahe 40n60 aur 15 ohm ka registration kharab ho jata hai,pls help