On this video you’ll see how to disable the spindle drive and its power supply to separate any spindle alarm and be able to test X , Z, turret and any other machine component if has more.

Опубликовано:

 

14 окт 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 3   
@sant647
@sant647 Год назад
Hello sir 5C alarm code on Spindle drive while sp orientation..what we need to check??..I have replaced PLG sensor with PCB.. feedback cable... spindle drive..also checked parameters with other seems ok...what we check further.. Thanks
@FabianAchaval
@FabianAchaval Год назад
Hi there. It is so important to be precise with the data when asking for support. In this case please provide the spindle drive model, the spindle motor model, the NC model, the alarm you have on the NC (complete text). In regards to the changes you made, provide: 1) encoder brand and part number 2) PCB brand and part number Regards.
@rmkbrothers8698
@rmkbrothers8698 Год назад
If I disable MDS-B MODEL we needs to alter any parameters?