Тёмный

Membrane Slab Vs Shell Thin Slab in Etabs |Membrane Vs Shell thin |When to use membrane & shell thin 

Civil Engineering Mastery
Подписаться 65 тыс.
Просмотров 2,1 тыс.
50% 1

Hello Friends!!
This video explains what is membrane and shell thin slab, how to model the membrane & shell thin slab in Etabs, result comparison between membrane & shell thin slab, the difference between membrane & shell thin slabs, and when to use membrane & shell thin slab.
Keep Watching!!! Happy Learning!!!
Join this channel to get access to perks:
/ @civilengineeringmastery

Опубликовано:

 

15 окт 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 10   
@ShrawanShah-h2t
@ShrawanShah-h2t 2 месяца назад
So nicely explained...and ma'am what is the difference between shell thin and shell thick.
@ravishankar.p5542
@ravishankar.p5542 10 месяцев назад
Informative thanks.. do similar structural concepts..
@CivilEngineeringMastery
@CivilEngineeringMastery 10 месяцев назад
Glad it was helpful!
@brigadeshivu
@brigadeshivu 2 месяца назад
Clear explanation thanks mam
@CivilEngineeringMastery
@CivilEngineeringMastery 2 месяца назад
You are welcome 😊
@nicolasmarie4398
@nicolasmarie4398 9 месяцев назад
Thank you very much. If I have well understood in most cases, we have to go to shell thin and in times when much need to go to the beam like in staircase or heavy machine we go to membrane. I will like to know whether when we select slab we can select the overall slab in 1 go example by clicking on the first corner to the opposition corner of the whole building or it needs to be panel by panel and if panel by panel we need to define areas bounded by four column. I wish I could send you a picture to clarify my question. Is there a way to contact you for further information. Thanks.
@CivilEngineeringMastery
@CivilEngineeringMastery 8 месяцев назад
You are welcome. civilengineeringmastery@gmail.com.
@nicolasmarie4398
@nicolasmarie4398 9 месяцев назад
I have seen that in membrane you have the option to define the slab as one way whereas this is not possible in shell thin. Does that impact something in designing a one way slab as shell thin?
@richardakela9702
@richardakela9702 2 месяца назад
I thought stiffness modifiers are only applicable under seismic design?
@nicolasmarie4398
@nicolasmarie4398 9 месяцев назад
There is another option called shell thick? At what thickness of the slab do we need to use this? Thanks.