MGA MALING NAKASANAYAN NA GINAGAWA SA CONSTRUCTION - PART 1 

Aron James Garcia
Подписаться 131 тыс.
Просмотров 1,4 млн
50% 1

MGA MALING NAKASANAYAN NA GINAGAWA SA CONSTRUCTION - PART 1
This video aims to correct the wrong practices on construction sites and improve the quality of work.
_________________________________________________________________________________________________
What is Fair use?
Fair use is a legal doctrine or a Law that allows the reuse of copyright-protected material under certain circumstances without getting permission from the copyright owner.
This video is edited under the Fair Use Law of RU-vid. No copyright infringement is intended. Credit to the owner of the Image, Video clip, Music background, etc.
Credit to the owner of the video clip
HOOK OF REBARS FOR FOOTING
• PAANO MAG ESTIMATE NG ...

Опубликовано:

 

24 дек 2021

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 959   
@junredoblado2171
@junredoblado2171 2 года назад
Awesome Yong pagtatama sa maling ginagawa sa construction site. Na papansin ko ring pagmamadali at pagtitipid sa materyales sa construction. Maganda talaga magkaroon ang mga constructor or construction employee ng seminars para sa mga tama at Maling ginagagawa sa construction site. Meron din akong napansin Yong supervision ng LGU - DENR Engineering o kung sino man ang dapat mag supervise lalo na sa mga construction developer, kung tama ba Yong kanilang sawage system. Minsan sa mga drainage eh meron mga hindi MagandAng amoy walang patay na hayop doon. Parang sa ganitong system patungkol sa sawage system lalo na sa pagitan ng construction developer at engineering LGU Eh nagkakaroon ng something kaya patuloy ang Maling ginagawa sa konstruction site.....dapat talaga magkaroon ng malawak usapin sa ganyang pagmamalabis. Thank you sa ganitong content....... Awesome.....
@nikohiroyagami8377
@nikohiroyagami8377 2 года назад
Keep it up sir. Marami po matutunan di lang po mga engineering pati n din po mga foreman at mga magplano magpagawa ng bahay. Dahil po sa ganito video tataas po kalidad ng mga ginagawang mga bahay dito satin. Salamat po
@purisimagayas5923
@purisimagayas5923 2 года назад
Thank you sir for taking the time and having the courage to right the wrong. And also for sharing your expertise.
@jessiepal-ag1855
@jessiepal-ag1855 2 года назад
Oo nga,tama c sir,kung may contrata cya at cya pa ang nag aasis sa mga mang gagawa,e kaso ngayon kahit nga sa mga building may mang coraption na nangyayari dito pa kaya sa media makalikom lng ng like,subcription at viers ----
@cesarcacayan6916
@cesarcacayan6916 2 года назад
May mali sa footing foundation: walang compacted gravel bed (90% compaction density). Hindi binubuhos ang graba kapag naasinta ang footing rebar. Correct ka diyan, hindi tama ang preparation ng foundation sa video. Walang alam ang mga manggagawa sa tama rebar installation standard at kailangan ng direct supervision ng engineer. Para maiwasan ang pagasya ng labor sa pagkalas at reinstallation ng rebars. Dapat na basahin ng mangagawa ang structural notes and direction ng nakasaad sa plano. Hindi lahat ng construction ay magkapareo. Nasasaad sa structural notes and detail standards na gagamitin sa project Correct ka diyan. Ang vertical rebar ng mga poste ay dapat nasa ibabaw ng footing rebar.
@allandizon5601
@allandizon5601 2 года назад
galing, God bless you sir Tama at napaka importante ang payo mo sa lahat ng maling gawi.
@NicknVio
@NicknVio Год назад
Very informative CE-kabaro. Eto rin madals na problem namin dito sa pag-prepare namin ng mga plans bilang AR . Sa ibang munisipyo bawal mag discharge ng waste from septic tank sa abutting na lupa dahi sa Clean water act na basis. Sa ibang Munisipyo naman allowed at magandang gamitin etong napresent mo dito sa video. Sa case naman dito sa amin sa Baguio, allowed before pero dahil nag-exceed na ang population, di na kaya ng Treatment plant, binawal na these years. And mga house owners ay naka-depende nagyon sa "suction" na napaka mahal. Narealize ko, kanya kanya pala Local Code pag dating dito sa discharge ng septic tank. However, responsibility dapat ng isang Munisipyo or City na magprovide ng centralized Sanitary Treatment Facility sa nasasakopan as part of City/Urban or Community Planning para maka-connect sila dito for septic tank discharge. Dito dapat pumupunta mga Tax ng community. Thanks so much for sharing your knowledge. More power to your channel!
@unitrendmarketing
@unitrendmarketing 4 месяца назад
its good to know that you are giving much info to our local plumbers how to plumb properly and not create polution. problem we have there is lack of information. i am a registered mechanical engineer there in philippines and a practicing mechanical engineer here in uk doing compliance for MEP services. if its combine sewage this must be tap from a drainage connected to water treatment plant with drainage interceptors, for surface water only, it must have a interceptor and the outfall is going to the river. this requires environmental permit. if there is no public connection going to the treatment plant for the septic tank this is connected to the fieldrain which what you show. some surface water are also connected to a soak away. this is the reason why our philippine rivers are poluted because of ignorance.
@murxart8323
@murxart8323 2 года назад
Good job po. More on reaction videos pa po para maitama yung mga maling practice sa site. Keep it up
@gnekotv
@gnekotv 2 года назад
Tama ka brad. Nais ko rin sana gumawa ng mga info videos gaya neto para i-correct din ang mga maling practices on site. Nakikita ko rin on site mga maling practices nila na dapat tinatama ng mga On Field/SupervisingProfessionals.
@dominicbuilder
@dominicbuilder 2 года назад
Good and correct advise to obtain standard construction practices...mahalaga ang technical supervision to create a strong dependable structure. Salamat sa mga correction na dapat sundin.
@joelcjabonete
@joelcjabonete 2 года назад
Very informative.!!! Thanks for sharing this.!! 👍👍👍
@bojiegrezula9213
@bojiegrezula9213 2 года назад
Good job sir, isang hakbang na to para mas mabigyang linaw at ideya sila sa mga mali at dapat gawin pagdating sa ganitong aspeto. maraming salamat sir Godbless
@joshu5097
@joshu5097 2 года назад
sir ipagpatuloy nyo lang ito malaking tulong ito sa mga walang alam na may ari ng bahay na may balak magbagawa para magkaroon ng good idea.... salamat....
@gdvictvmix2414
@gdvictvmix2414 2 года назад
Thank for sharing this kind of video. Very interesting regarding how to make exact construction methods.
@ecjtv6522
@ecjtv6522 2 года назад
Yes sir saludo po ako sayo mahirap magtiwala sa mga vloger na gumgawa ng ganyan klase like constrution works
@jerrygregorio1037
@jerrygregorio1037 2 года назад
Salute to u sir,ganyan n ganyan dn Yong gnawa ko s isang project ng DMCI cunsunji, desiel power plant somewhere in iloilo city. Keep vlogging and educate some who wants to learn about Dat clip. More power God bleesed us.
@ItsLeisure
@ItsLeisure 2 года назад
Aron James Garcia-Thank you and please continue to provide more content related to any such correction that we can help to share and have them improve their skills and workmanship and professionalism.
@juliesalvador16
@juliesalvador16 2 года назад
Next video po para sa mga p pag bend ng bakal ser james
@rauldelacruz7821
@rauldelacruz7821 2 года назад
weyuopoeh vbvnnokrp
@rauldelacruz7821
@rauldelacruz7821 2 года назад
weyei rekol uekindlopdlfdlogs
@federicomandac5794
@federicomandac5794 2 года назад
Dapat lahat ng gawa ng foreman ay ma double check ng site Engr kung nasusunod ba lahat ng structural notes, importante yon at ito din dapat ma inspect ng structural Engr bago buhusan ng concrete para masigurado na nasunod lahat ang structural requirements, at dapat i certify ng structural Engr ang inspection report.
@kinitotv2777
@kinitotv2777 2 года назад
nice. mahusay po ang pag detalye nio at pag puna sa mga maling post sa mga video nila. hope marami pa po kayong video na mapuna at maitama para sa ikakaunlad ng ating industriya sa pag construction.
@raulybanez7082
@raulybanez7082 2 года назад
Very good Presentation kaya nagSubscribed na ako. HAPPY NEW YEAR BOSS! Please go go go with your Task. Super kitang hinangaan dito. God Bless!
@arttellama2408
@arttellama2408 2 года назад
Marami mali sa constrution dto sa pinas: 1. Implementation ng construction codes, kaya hindi matibay, malimali, at substandard. 2. Implementation ng city/municipal zoning and planning. No uniformity. Kaya masikip daanan, pangit at wala sa ayos mga lugar natin. 3. Lack/no city sewage system kaya mabaho at marumi mga ilog natin. 4. Lack of skills, knowledge, trainings, not certifified ay gumagawa n ng bahay, kaya di maayos pagkagawa at substandard.
@DP24PH
@DP24PH 2 года назад
[DP] Adding to this is the issue of safety wherein most housing-related construction do not cordon-off properly with the GI-based wall/gate, leading to accidents. Plus, construction materials must be stored inside wherein most of construction materials are obstructing the sidewalk, bike lane, and drainage, leading to littering citation and other flood damages.
@GamilJoel1974
@GamilJoel1974 2 года назад
Tama ka jan sir James hindi lahat ng napapanood sa you tube or social media ay tama. Dapat maging mapanuri ang tao. ... Tnx a lot sir James. 🙏🏼
@MrFUNKISTAH
@MrFUNKISTAH 2 года назад
tulad ng napanood mo may mali din sa info nya hehehhhe
@moisescarino.kuyamoi6569
@moisescarino.kuyamoi6569 2 года назад
Regarding sa 2nd video clips ay kapuna puna naman talagang malaki ang pagkakamali. Dapat muna talagang i-compact ang lupa then after ng compaction, dapat ay maglagay din po Tayo ng tinatawag ng lean concrete or latagan ito ng makapal na plastic upang sa ganun sa huwag sipsipin ng lupa ang semento or anumang mineral na meron ang lupa, at tsaka ito lagyan ng spacer. Then maglagay ng formworks. Advice ko lang po, dapat eh naka-pedistal type ang foundation para maging matibay. Salamat po
@jamesfrancis2144
@jamesfrancis2144 2 года назад
salamat sa info sir. ituloy nyo lang ang pag educate sa mga kumukuha ng kaalaman sa socmed.
@hermogenestroncoso9909
@hermogenestroncoso9909 2 года назад
Very informative presentation. Iba talaga pag licensed at experienced engr ang magturo. Galing!!!
@princessplays9957
@princessplays9957 Год назад
Paano Po yong matubig na Lugar gaya nang cotabato?thanks po
@joeyfeliciano9199
@joeyfeliciano9199 2 года назад
Big YES naman jan. Hindi lahat ng nakikita ng mata ay tutuo o tama!
@elviraplandez5002
@elviraplandez5002 2 года назад
Thank u po sa information sir..always watching your vlogs..godbless
@joselitojose3056
@joselitojose3056 2 года назад
salamat po sir sa iyong magandang advise mabuhay ka po sir god bless po merry christmas happynew year po
@martinosas9215
@martinosas9215 2 года назад
More videos pa po engr. Very Informative
@joeluy5473
@joeluy5473 2 года назад
Napaka informative po salamat
@gregorioestioco6077
@gregorioestioco6077 Год назад
Ayos yan sir!!! Kadalasan po kasi hindi na masyado tinitignan if may mali or may part na kailangang iayos...Yung style na "pwede na"... If property na po ang pinaguusapan, syempre pinaghirapan ang perang ginamit, kaya magawa dapat nang tama...
@romyturla5097
@romyturla5097 Год назад
Thank you po Engineer...salamat sa iyong educational video.
@iamsmartzed2256
@iamsmartzed2256 2 года назад
I agree on your first video, to put perforated pipes, but in my construction experience, that would only work for a sandy or loose type of soil, but it won't work in long term on a loamy/clayish type of soils. With all the grime and sludge it would just clogged the perforated pipe in just few months of use.
@melchoranacion9994
@melchoranacion9994 2 года назад
cguro po it will require greater cross sectional area ng gravel bed around the perforated pipe to compensate ung seepage rate ng other types of soil
@ismailrohaan
@ismailrohaan Год назад
Tama
@jerrycasana1157
@jerrycasana1157 2 года назад
Thanks for sharing Sir
@user-fc4pp4df9q
@user-fc4pp4df9q 7 месяцев назад
Thank sir sa npanuod kung lecture nyo.
@nardcastro9903
@nardcastro9903 Год назад
Salamat sir at ibinibigay nyo ang tamang papaparaan sa construction. Malaki maitutulong sa akin lalo na tungkol sa bakal dahil dati akong steelman sa malaking kompanya sa Manila.
@noside8469
@noside8469 2 года назад
We keep on learning, no matter what the age... There are old and there are new Importante proper at tamang paraan
@koreanohilaw8576
@koreanohilaw8576 2 года назад
Sir yung sa mga bahay sa probincia ang mga septic tank is walang buhos yung flooring yun po kc naka sanayan d2
@Sportsandnews1985
@Sportsandnews1985 2 года назад
Npakalinaw na pagpaliwanag sir at siguradong may matutunan talaga Ang mga makapanuod ,, kompleto detalye ,salamat sir ngkaroon na namn ako ng ideya kung sakaling maybe ma incounter akong ganyan,,salamat sa pag share
@maalat
@maalat 6 месяцев назад
Thank you for the information.
@krex23tv73
@krex23tv73 2 года назад
Galing ng content mo idol
@aldrinlaura9660
@aldrinlaura9660 2 года назад
iba tlga pag check ng engineer sumunod sa specification
@coolferds06
@coolferds06 2 года назад
Very good advice. Thank you.
@pjgabs9061
@pjgabs9061 2 года назад
THIS IS VERY INFORMATIVE !!!!!!!!!!!!!!!!!!!!!!!!!! I LOVE IT!!!!!!!!!!!!
@ItsLeisure
@ItsLeisure 2 года назад
Video clip 2 rebar formworks needs to be at least 3" in high space. We call it Dobbies. Rebars must be at least 3" away from Dirt per IBC.
@GabsRomano
@GabsRomano 2 года назад
Very informative, keep sharing your knowledge and more power to your channel engr.
@ARONJAMESGARCIA
@ARONJAMESGARCIA 2 года назад
Thank you Engr.😊
@vivroursolen6177
@vivroursolen6177 2 года назад
@@ARONJAMESGARCIA sorry po ,pero may nakita ako na ang footing bago lagyan ng forms at rebars ay ni lagyan ng polyethylene sheets ito ay after the compaction. Paki comment po?
@leonardoespina480
@leonardoespina480 2 года назад
@@vivroursolen6177 Tama Yan sir protection po Yan lalo na kung malapit sa tabing dagat sa ibang bansa. Ang bakal nila balot ng manipis na plastic ginagamit po Yun sa malapit sa tubig alat at kung chemical plant base po Yan sa experience ko sa ibang bansa
@enricosilvio8427
@enricosilvio8427 2 года назад
Many thanks po sa info Engr.
@JBamboo
@JBamboo Год назад
leanings po salamat...dmi ko natutunan kahit di ako engr. pero valuable topic po ito.
@silentwatcher1455
@silentwatcher1455 2 года назад
Good presentation and accurate info.
@leirapada926
@leirapada926 2 года назад
Ha good ,alam mba sinsabi mo
@teddyteorima4710
@teddyteorima4710 Год назад
@@leirapada926 Hindi Po ito dapat na sundin na posonegro may lagusan sa rever dahil pullution Po ito sA iBang ilog katulad Lang nilason nyo Ang mga tao
@renalynlucas67
@renalynlucas67 2 года назад
Tama kau jn sir,ako isa Rin akng construction boy lhat ng nsa Plano dapat sinusunod
@rjlinnovations1516
@rjlinnovations1516 2 года назад
Excellent and fully informative blueprints at according to the code ang video po ninyo. Excellent tutorial po ang video ninyo. Nag subscribed na po ako sa RU-vid channel ninyo para sa suporta tulad nating mga kababayan. Pagbati po sa inyo mula sa Canada 🇨🇦
@rjlinnovations1516
@rjlinnovations1516 2 года назад
You’re welcome po. Ingat po kayo 🙏
@ARONJAMESGARCIA
@ARONJAMESGARCIA 2 года назад
Salamat sir😊
@rjlinnovations1516
@rjlinnovations1516 2 года назад
@@ARONJAMESGARCIA you’re welcome po🙏
@arch.l.a.deleon445
@arch.l.a.deleon445 2 года назад
Marami akong natutunan sa video mo, sa totoo hinahahayaan ko na lang basta tama ang sukat ng mga bakal at distance sa porma at agwat, bilang arkitekto, nakafocus ako sa asthetic na anyo ng istraktura lang, ngayon alam ko na ang makatwirang dahilan sa tamang desinyo ng mga bakal, Maraming salamat po sir! sa kaalaman.
@tatzkie6275
@tatzkie6275 2 года назад
Bakit mga subdivision wlang waste water, sa dami ng bahay na may cr,di nman pinag bawal ng denr..
@nimfalaganapan5620
@nimfalaganapan5620 2 года назад
The problem is systemic from the top... Meaning from start of building permits..Ang city/municipality puro collection lang ng building permit fees...wala na mang periodic building inspections...kung meron man...pagtapos na for occupancy permit...
@speedhunter7303
@speedhunter7303 2 года назад
Totoo yan..eh pati yung city engineer substandard din..ugaling ‘pwede na yan’
@karage1035
@karage1035 2 года назад
@@speedhunter7303 korek.. maraming mga bahay sa pinas ang "pwede na yan " lalo sa rural region. Walang standard. Kulang sa safety. Katulad ng electrical, sanitation at iba pa. Kaya pag nakaroon ng disgrasya,, Nag turuan na at sisihan.
@jolomaniago1728
@jolomaniago1728 2 года назад
Very informative presentations sir! Additional point outs lang if I may: 1.) Baffle should be open vented as per code, hindi dapat extended yung pipe pataas sa clean out. 2.) "Leaching Chamber" is yung open bottom chamber kung saan doon mag leach yung black water. The proper term is Secondary/Tertiary Chamber. 3.) There are restrictions to the on site waste water treatment/Seepage pit, Generally : Lot area if there is no space for it and soil type/condition on site. Overall, It was a good watch !
@ARONJAMESGARCIA
@ARONJAMESGARCIA 2 года назад
Thank for additional information Sir,👌🏽👌🏽
@biklogtv5508
@biklogtv5508 2 года назад
Maraming salamat idol sa mga info
@helariojaspi3431
@helariojaspi3431 Год назад
Thank you sir very impormative
@silentwatcher1455
@silentwatcher1455 2 года назад
You lack one more info on footing. Footing is needed to distribute the load from the column to ground uniformly.
@zzzzz8990
@zzzzz8990 2 года назад
Kawawa naman ang mga titira sa ginawa ng ganitong worker. It probes of the common saying that A LITTLE KNOWLEDGE IS DANGEROUS. MARAMDAMAN MO SA PAGSASALITA NG WORKER SERYUSO SYA AT DEDICATED WORKER . KAYA LANG YUN MALILIIT NA STEP NA OMIT NYA MALIIT PERO DOON NAKASALALAY ANG TIBAY NG BAKAL AT NG BUONG STRUCTURE. SAYANG DI AKO NAGING ENGINEER.
@domeng1231
@domeng1231 2 года назад
AJG good job very informative Ang topic mo.
@jaymanaloto2067
@jaymanaloto2067 2 года назад
More power engr.happy new year sayo.
@educaspe5887
@educaspe5887 2 года назад
iyang video #2, ang kadalasan problema sa mga construction na walang engineer, may parte ng bakal sa pundasyon na nakadikit sa lupa, or loose ties, yung hindi mahigpit ang pagkatali, 90% ng construction ng mga bahay na walang engineer ay ganyan ang problema,
@juanpalaca3137
@juanpalaca3137 2 года назад
Korek ka sir... Kaya karamihan sa manila noong nagtambay ako nakikta ko mali ang ginagawa nila mga septic tank doon itatapon sa istero.
@trysomeart9111
@trysomeart9111 2 года назад
very good informative, fact checker ng mga kamoteng builders
@alexjr.salindato3403
@alexjr.salindato3403 2 года назад
Great and well brilliant help tips and information ho sir, God bless you more🙏❤
@raymondomuk4806
@raymondomuk4806 2 года назад
Sir sna MA feature nyo. Pwde ba maglagay nang steeldecking Ang isang bahay Lalo na pag ung bahay ay may exsisting na biga.ano po dapat Gawain
@donediesalomon6278
@donediesalomon6278 Год назад
Pwedi
@benpung
@benpung 2 года назад
In a very ideal setting, the soil absorption field is what is required. Unfortunately you cannot do that in a 10m x 10m (100sqM) lot or even a 250sqM lot... It can be done in the farm, but not in the city or subdivisions. It's the subdivision management and the government negligence is at fault here, they should have constructed a separate storm drainage and sanitary sewers connected to a waste treatment plant....
@FACE-PROFILERZ
@FACE-PROFILERZ 2 года назад
Philippines are one of the poorest countries. We cannot afford such modern things. That's why we had our own and the ends goes to street. Here in California is way different as its very strict in regulations.
@80ivannoel
@80ivannoel 2 года назад
Tama, may mga laws regarding sa tamang sanitary practises tayo na similar naman sa standards ng mga 1st world countries pero kulang sa implemantation. takot din mag-implement ang local government baka hindi na iboto sa next election or kulang sa tao or experts.
@benpung
@benpung 2 года назад
@@FACE-PROFILERZ The funds for the creation of a functional waste water system is ingrained in your water bill. However the water utilities did not implement it. The two water concessionaires in Metro Manila is now has waste water treatment plants, however there are still no separate storm and sewer lines...
@arkikrist
@arkikrist 2 года назад
agree yung perforated maganda yan pag malaki yung lot mo, much better to consult local sanitation code sa lugar. dito sa cebu 3 chamber septic yung minimum requirement para sa residence na di located sa loob ng subdivision.
@seanjohn1032
@seanjohn1032 2 года назад
eto ung na iisip ko sa first clip ng video, pag maliit lupa mo bawal ka na tlga mag tayo ng bahay na may cr.. hahahaha
@jemilarde5231
@jemilarde5231 2 года назад
Galing ☺️ may natutunan ako
@kabangka
@kabangka 2 года назад
sakto idol... salamat for correcting some mistake of construction workers sa pagawa ng mga septic tank...
@ItsLeisure
@ItsLeisure 2 года назад
These are the good example the CORRECTIVE FACTORS base upon the real installation situation which are not conformance to IBC code.
@jaypaulcayabyab6775
@jaypaulcayabyab6775 2 года назад
Kailangan dyan mag build ng leaching field para sa outlet ng septic tank
@reynoschicote
@reynoschicote Год назад
thank you sir. iba talaga pag licensed engineer ang magturo matibay ang logica.
@JoSimpleWorks
@JoSimpleWorks 2 года назад
Good job sir! Thank you sa pagtutuwid!
@akasnam2393
@akasnam2393 2 года назад
yong ibang contructor kasi foreman lang walang engr,akalain mo CF nila mali na ang bending,bato pa ang spacer,stirrup malayo ang distance,walang graba sa ilalim diritso na buhos,tie beam 16mm gamit gang poste,yong dulo naman ng tie beam yon bang tagos kung baga sa poste makikita yan if tapos na ang buhos ay 20mm na,para sabihing gamit sa tie beam ay 20mm,sa totoo 16mm lang.
@rollyhernandez5762
@rollyhernandez5762 2 года назад
Alam nyo kc iba ang expirience ng mfa workers sa kompanya kompara sa mga gumagawa lang ng mga bahay kagaya ng foreman kung mga ex abroad yan cgurado pulido magpatrabaho yan kc sanay na yan na mga engineer at quality control ang nakaka sama kung dto lang sa pinas at mga bahay ang ginagawa medyo kulang pa talaga sa kaalaman
@budzosana
@budzosana 2 года назад
dapat d senesemento ang flooring sir pra d madli mapuno yan ang maling nkasanayan jan s parteng maynila,sabagay pra kumita c malabanan dto s amin s pangasinan walang floring pra masipsip ang tubig at matagal mapuno kht 20 yrs d pa puno ang me flooring baka 5 yrs or 10yrs puno na need na c malabanan f mapuno hehhe
@markusjordantesoro2992
@markusjordantesoro2992 29 дней назад
Oo nga kaso pag may poso malapit yari na.
@eliseoreyingles1952
@eliseoreyingles1952 2 года назад
Salamat sa tips. Dito mo makikita na may mga tinamaan ng bato sa langit at galit na galit dahil sa maling kaalaman. Mahilig sa short cut at hindi alam ang standard. Natuto lang gumawa sa construction ay akala mo mas magaling pa sa designer at hindi maintindihan ang tamang sistema. Kaya lahat ng baho ay sumisingaw lalo na pag tag ulan dahil sa kaisipan ng maraming nagmamarunong na ok na yan. Kung sana maipatupad din ng tama ng gobyerno ang pag control ng mga construction ng mga bahay at structures mula design hanggang implementation, mas maging maayos na sana ang maging kabahayan natin. Yung nagsasabing hindi sinusunod ng Engineer sa kanyang bahay ang kanyang sinasabi ay maaring iskwater lang din sya kaya hindi sya maniwalang may mga sumusunod din naman talaga sa mga regulasyon.
@juanitoilagor5160
@juanitoilagor5160 2 года назад
Galing mo sir,god bless you ❤️❤️❤️
@marlonalcantara71
@marlonalcantara71 2 года назад
Dapat specified ang depth the filter rock under perforated 4" pipes. Also specified that above the perforated pipes, geotextile should be on the top to gilter the dirt or small particles that may seep down to filter rock and clog them. The space between filter rock must be maintain to allow the gray water to pass. The area or size of leaching gield or you called "private treatnent system" must be compute based on the the natural absorbtion rate of the underneath soil in inches per hour. If the leaching field is too small for the daily waste water discharge of the facility or structure, it will not work and end up over-flowing the septic tank.
@ferdinandsagala918
@ferdinandsagala918 2 года назад
Mali pati ung location ng links. Nasa ibaba nagsimula ung 5cm. Dapat kung saan nagsimula ung taas ng footing
@jinnycanada8512
@jinnycanada8512 2 года назад
Maraming salamat po sir sa dag2x kaalaman👍
@leonilodelosreyes6035
@leonilodelosreyes6035 2 года назад
Thank you sir..!
@arveldasugo5166
@arveldasugo5166 2 года назад
Tama ang observation ni engineer sa video clip 1 at 2, yung liquid waste galing sa leaching chamber ay pwede lng i tap sa sewer line na kokonekta sa STP or sewage treatment plant..paglabas ng tubig galing sa STP ay malinis na, yung sa video clip 2 additional ko lng ang concrete cover ng foundation ay 75mm..dapat compacted at least 90% passed sa density test pero inaangat namin ang passing percentage to 95% para safe na safe, yung gravel bedding or lean concrete dapat yun ang maauna before maglagay ng bakal..paalala po lamang "LITTLE KNOWLEDGE IS VERY DANGEROUS"
@reynaldobaclig6719
@reynaldobaclig6719 2 года назад
Maraming mga karpintero o construction worker ang hindi sumusunod sa standardisation ...gaya na lsng ng septic tank construction.mostly dito sa pilipinas humuhukay lng ng malalim tapos tatakloban lng ng concrete ayos na...kaya ang under water system natin napopolute
@yanocaboto
@yanocaboto Год назад
Sa video clip #1, normal lng na magtap sa drainage line dahil effluent water na iun. Ang sludge ay naiwan na sa 1st at 2nd chamber which is pinahihigop sa malabanan. Anong sinasabi mo na STP? Meron ka bang nakitang stp sa mga residential areas? Wala db. Ang explanation sa video na ito ay theoretical lang. Iba ang actual application.
@julyparin4432
@julyparin4432 2 года назад
Ah sir siguro sa mga buildings or high rise pwede o dapat lagyan ng sewage filter pagkalabas from leaching chamber, pero sa mga subdivisions or house construction diretso ang pipe from leaching to drainage pipe or imbornal. No need for filter dahil nakadesign ang mga drainage pipe to catch waste from every household. Kaya nga may leaching kasi sya na ang sumasala anuman ang lumabas going drainage.
@IGORIDERVLOG
@IGORIDERVLOG 2 года назад
thank ulit lods, napaka informative lahat ng video mo.salamat sa pag share
@ezekdaelo
@ezekdaelo 2 года назад
Ang galing. Nice tips.
@marvinblogs6747
@marvinblogs6747 2 года назад
😀😀Kilala ko po yong mga vlogger na ito boss yong isa me eng. Laging kasama yan ibig sabihin mali sya😀😀😀 yong mga ibang nag cocoment dito iwan😀😀
@hazelvlog7150
@hazelvlog7150 2 года назад
Tanungin mo c garcia pakita nya septictank nya sa bahay nya mismo kung ganyang sinasabi nya sa vlog nya tingan natin kung kaya nya. Cgurado sa drinage din ang baksak nyan hahaha.
@randypedrosa9725
@randypedrosa9725 2 года назад
may iba kasing engineer bro na kahit Mali si foreman tikom nlang ang bibig dhil sa pakisama at ang iba nman minsan malakas magpainom si foreman Kay engineer.. Hahaha
@ItsLeisure
@ItsLeisure 2 года назад
Any forms of waste contaminated are not applicable to any bypass illegal tap without any jurisdiction authorithy consultation & approval. There must be a certain codes that needs to abide per IBC. Especially the waste contaminated are coming from residentials. Video Clip 1 is the accurate explanation how to secure your own waste management.
@eliseorey5174
@eliseorey5174 2 года назад
Ang engineer naito marunong lng s papel at drawing pero s aktuwal n pggawa hindi alam .tumigil k na lng iba n ang may experience kesa dun s ngpapaturo pa.
@ItsLeisure
@ItsLeisure 2 года назад
@@eliseorey5174 agree
@jayveevaldez5795
@jayveevaldez5795 2 года назад
It is true that the efluent must not be tapped towards the public storm drainage system. It should be tapped towards the public sewer system. In the absence of public sewer system, do not attempt to tap your effluent elsewhere. Septic drainfields are no longer encouraged unless you have full monitoring of your GES or the General Effluent Standards setforth by the DENR. The GES should comply the tolerance before discharging towards the septic drainfields. Otherwise, water tables might be contaminated in the process resulting to adverse health conditions of the persons within the certain radius of contamination. Have your sludge be siphoned by an authorized waste water collector by the DENR like your local water service provider in the absence of public sewage collection system.
@olimpiaconcepcion3138
@olimpiaconcepcion3138 2 года назад
@@eliseorey5174 tama po ang expirience malaking bagay yan sa construction pero ang kaalaman para sa longlife project lalo na sa malalaking construction ay nasa mga engineers ang architect lamang .
@shulamgilead5382
@shulamgilead5382 2 года назад
How about legalities? Bawat building na tinatayo ay dapat dumadaan sa Munisipyo para sa building permit. Of course they need to submit a blue print pero kung negligent ang kinauukulan at hindi na mag-iinspect, magkakasakit na lang tayo at masisira ang kapaligiran. Ganyan talaga pag 3rd world thinkers...basta basta trabaho.
@KaVinceTV
@KaVinceTV 2 года назад
Maraming salamat sir madami n nmn ako natutunan tungkol sa constraction
@nelsontorres380
@nelsontorres380 Год назад
New subscriber sir salamat po SA ma tyaga nyo pag bigay Ng Tama information...
@hazelvlog7150
@hazelvlog7150 2 года назад
Unang una merun b tayong mga treatment plant sa pinas? Mag pakita k nga sa mga video mo n ganung cnasabi dyan sa vodeo mo ang ginawa mo naka hangang sa video at salita k lng hind mu naman kaya gawin sa mga project mo. Hihintayin k yan sa content mo kung kaya mo pani dinindigan ang nasa video mo nayan
@kadraftsman4374
@kadraftsman4374 2 года назад
kya nga sir..prove nya muna bago tyo maniwala.wala nmn masama kung makabuti sa environment ntin..ang problema kasi wala nmn treatment plant ang pilipinas...pagmasdan nya ung mga residential d2 sa pinas...may provided ang residential developer ng sewer drainage pra doon mag tap ang mga lot owner..pero tanungin mo sila saan nila bibagsak ung provided sewer drainage ng boung residential? sa ilog din yan pustahan pa tyo.
@alfonzoacoba4938
@alfonzoacoba4938 2 года назад
@@kadraftsman4374 meron Po sa Baguio mahirap gumawa septic tank doon kaya mayroon Sila sewerage treatment plant pipena lng nagkokonect sa inodoro papunta sa planta
@hazelvlog7150
@hazelvlog7150 2 года назад
@@kadraftsman4374 c aron garcia sa salita lng yan tingnan mo hind maka sagot hahaha. Baka ang bahay nya mismo ganyang design n ginawa n kabayan. Baka sa salita nya lng kayang gawin yan.
@FACE-PROFILERZ
@FACE-PROFILERZ 2 года назад
Ok rin yung septic tank idea ng Japan. The building roof collects rain water that flushes their toilets. Tapos diretso sa septic tank. Tatlo o apat na division ang tank. Main, secondary 1 and secondary 2. Tapos dun sa last tank merong Water Lily sa ibabaw harvesting the leaves for the cow to eat. Yung ugat ng Water Lily cleans and purifies the water. Naglagay rin sila ng Tilapia to eat the algae. Sabi nung engineer/designer pag kinain namin yung Tilapia kumpleto na ang cycle.
@allnighterist
@allnighterist 2 года назад
May link video po kayo nung system na yan? Mukang Interesting po kasi.
@FACE-PROFILERZ
@FACE-PROFILERZ 2 года назад
@@allnighterist Ha'mo research ko yan. Narito kasi ako sa California at nabasa ko yang Japanese architectural designer sa Popular Science Magazine. Maganda subukan sa pinas yan kasi malaya tayo on regulation, dito mahigpit. Wala kaming septic tank sa lote namin. Sa Olongapo where I used to live nakita ko pa nung ginawa yun in the 70s sa bahay namin.
@valiantinviato3794
@valiantinviato3794 2 года назад
Wooow.. complete cycle na. Food web.. 😁😁
@FACE-PROFILERZ
@FACE-PROFILERZ 2 года назад
@@valiantinviato3794 Accordig naman sa Leviticus God commanded us to eat fish na merong palikpik at kaliskis. Dr. Arturo Arboleda (sa youtube) explain why Tilapia and others na merong kaliskis means lumalabas ang pawis nila or toxin sa katawan ng fish.
@jed9205
@jed9205 2 года назад
marami talaga ako natutunan sau engr. :)
@bdtconcepts-nb5kb
@bdtconcepts-nb5kb 11 месяцев назад
good idea yan sa mga independent contractor..salamat boss sa gabay mo...
@jayven8619
@jayven8619 2 года назад
Correction, di rin pwede na gumamit ng rebar spacer, mali po yun. Dapat concrete spacer tlga with the same strength ng structural member. Pag rebar, mangangalawang katagalan at papasukin na din ng tubig yung rebars sa loob.
@MrFUNKISTAH
@MrFUNKISTAH 2 года назад
wala pa ata experience kulang pa kaalaman, pag pasensyahan nyo na
@fannyandres3056
@fannyandres3056 2 года назад
Septic tank is considered primary sewer treatment tank... Like in manila direct to sewer line kasi meron silang sewer line... Sa pag kaka alam ko pasensya ka na... un mga walang sewer line na city combined drainage/sewer line system ang mga iyan, kaya me septic tank rqmt... Meron namang stp na ang rqmt kasi above 10k sq.m. na area ng bldg/struct. Ung mga na una pa na nagawa na sa ibang city meaning mali? hindi ka pa tao nun ginawa un ganun directa sa drainage ang eff.
@jubzl8592
@jubzl8592 2 года назад
Correct. Dependent siya sa local government din. May sari-sarili silang standard and requirements. Tulad ng nasa video... it appears na walang pwesto para sa gusto mong leaching area and mukhang yan ang code nila sa lgu.
@echckaravhotski8092
@echckaravhotski8092 2 года назад
tama
@russell383
@russell383 Год назад
@@jubzl8592 yung nasa video pang malakihang lote, e pano yung maliit lng space, tama po kayo
@freyakhal8796
@freyakhal8796 Год назад
Kaya nga pinalala nyo ang polusyon sa manila hnd pa nga sya pinanganak nun pero mas tama ang planning nya kayo kasi hnd nyo iniisip na sinisira nyo kalikasan lalo kakatawa ka.
@buildexvlog6920
@buildexvlog6920 Год назад
​@@freyakhal8796 I agree kaya dito sa taiwan pati canal dito andaming Tilapia kasi sumusunod sila sa tamang pagdisposed ng dumi.
@aldringerangco5272
@aldringerangco5272 2 года назад
Tama... hindi dapat iconnect s drainage. Its either sewer line or put a stub out for future connection kpag wala pang linya or pwedeng ipasipsip nlng yung septic tank thru manhole opening.
@lynricbuenavista9941
@lynricbuenavista9941 2 года назад
Ayos thank you sir
@qtythandle
@qtythandle 2 года назад
In theory and principle lang po meron, pero in reality bihira lang po nangyayari yan.
@silverjanuary8501
@silverjanuary8501 2 года назад
Pgkasabe palang ng 1 inches alam ko ng mali hehehe. Mabuti nacorrect nyo po d2 ang maling idea.
@hiddenninja7792
@hiddenninja7792 2 года назад
Salamat Lodi sa construction information.
@davesantos9473
@davesantos9473 2 года назад
Salamat boss
Далее
PAANO MAG DESIGN NG SEPTIC TANK AT MAGKANO?
22:51
Просмотров 1,1 млн
Your Septic System: Worst Mistakes
16:44
Просмотров 1,5 млн
MAGANDA BA GAMITIN ANG PLASTIC SEPTIC TANK?
5:52
Просмотров 39 тыс.
SUBSTANDARD REBAR PAANO MALAMAN? PEKE!
14:19
Просмотров 806 тыс.
Paano gumawa ng septic tank or pozo negro
7:36
Просмотров 42 тыс.
COMMON MISTAKE IN CONSTRUCTION  PART 2
13:26
Просмотров 89 тыс.
COMMON MISTAKES IN CONSTRUCTION - PART 1
14:27
Просмотров 2,1 млн
Ace+ Review Center | How to Design a Septic Tank?
38:12