Тёмный

MOST USEFUL/IMPORTANT PARAMETERS : ABB ACS 800 VFD 

bishant kumar
Подписаться 16 тыс.
Просмотров 16 тыс.
50% 1

MOST USEFUL/IMPORTANT PARAMETERS : ABB ACS 800 VFD

Опубликовано:

 

25 июл 2021

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 85   
@amirhussain4637
@amirhussain4637 5 месяцев назад
Kys bt hai bht acha Tariqa r zbrdast Information maza agya
@bishantkumar12589
@bishantkumar12589 5 месяцев назад
Sukriya sir. Please share with your electrical team 🙏
@pramodsahoo1375
@pramodsahoo1375 3 года назад
Thank you sir, valuable video. But it's a standard software. Plz make a video hoist software.
@technogamergaming1504
@technogamergaming1504 Год назад
thanks sir for your for making this vidio please make more this type of full vidio on all vfd and mainly yaskawa and danfoss and delta
@bishantkumar12589
@bishantkumar12589 Год назад
Okay sir.
@amitpagare5946
@amitpagare5946 2 года назад
Very informative video 🙏🙏👍
@bishantkumar12589
@bishantkumar12589 2 года назад
Thank you sir 😊 please support the channel... subscribe and share
@akhtarshamim2424
@akhtarshamim2424 Год назад
Love brother
@bishantkumar12589
@bishantkumar12589 Год назад
👍
@sujitsutar4953
@sujitsutar4953 3 года назад
Thank you sir....🙏🙏
@rakesh78070
@rakesh78070 3 года назад
Thank you Sir...I have one doubt how can i clear maximum fan running hours alarm in ABB ACS 800 VFD
@bishantkumar12589
@bishantkumar12589 3 года назад
ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-_pyCuF5zLFo.html
@bishantkumar12589
@bishantkumar12589 3 года назад
Sir. Please check this LINK ... Pl support the channel... subscribe and share
@rakesh78070
@rakesh78070 3 года назад
@@bishantkumar12589 Thank you Sir....Subscribed...expect more useful videos
@rajeshyedla3326
@rajeshyedla3326 2 года назад
Thanks
@ranjangupta5700
@ranjangupta5700 2 года назад
Sir How to set minimum speed that motor will achieve while starting VFD? and sir what is "1- 89.1%" written in the Top of the digital display?
@bishantkumar12589
@bishantkumar12589 2 года назад
In parameter 11.04 - set the minimum speed which is required, in there video, it's 0, set as required. & On HMI - 1-89.1% is the reference given by control room to run the VFD (out of 100%)
@ranjangupta5700
@ranjangupta5700 2 года назад
Thank You Sir! I have one more doubt ,What is meant by Jog speed or when we select Jog speed ?
@rishinathreghu579
@rishinathreghu579 2 года назад
hi sir, my abb acs 600 drive have i/o comm fault.what is the reason and how to troubleshoot and solve.
@arunvishwakarma6812
@arunvishwakarma6812 3 года назад
Sir plz make a video over dtc mode selection and parameters for dtc mode and how to set range of torque
@bishantkumar12589
@bishantkumar12589 3 года назад
Sir. As per my knowledge, DTC mode is selected only for applications where high precision of movement is needed. For general,scalar mode is okay. Torque is generally unchanged : -300 to +300 is set
@arunvishwakarma6812
@arunvishwakarma6812 3 года назад
@@bishantkumar12589 okay sir
@NICE_LIFE1986
@NICE_LIFE1986 2 года назад
Sir, If I operate drive to MCC panel. Is put same parameters according yo this video pls confirm.
@bishantkumar12589
@bishantkumar12589 2 года назад
Yes. Parameter remain same mostly
@kevin00861
@kevin00861 Год назад
Dear Sir, Thank you for your video, I kindly need your help, ABB VFD ACS800-01 , some parameter groups do not show up on the local control panel, the only parameter groups that show are 10, 11, 14, 16, 33 the rest do not show. And also the language selection which should be in group 99; it shows in group 33. I could not find any related setting in the drive manual. any clarification, please
@bishantkumar12589
@bishantkumar12589 Год назад
You must speak with your ABB service engineer. I am also a field engineer, do not know that much in details. If you still need help I can talk to my ABB service engineer but he is chargeable.
@kevin00861
@kevin00861 Год назад
@@bishantkumar12589 Yes please, I would be so grateful to you Sir would you share your email or WhatsApp number so i can send you the photos and video
@terus_belajar-
@terus_belajar- 2 года назад
I have Acs800, I have problem that acs800 have fault BR Wiring (7111), can you tell me how to fix it?
@bishantkumar12589
@bishantkumar12589 2 года назад
Sure sir. I'll check and let you know
@bishantkumar12589
@bishantkumar12589 2 года назад
BR WIRING (7111) 3.17 FW 5 bit 1 Wrong connection of brake resistor Check resistor connection. Ensure brake resistor is not damaged.
@pramodsahoo1375
@pramodsahoo1375 3 года назад
As I know, torque is different in star and delta but why motor always connect in delta for vfd control.
@bishantkumar12589
@bishantkumar12589 3 года назад
Sir. It's very thoughtful observation u did. Great. As of now I don't know surely y its VFD motor r connected in delta but... In my observation, I have seen only HT motors (6.6kv) are connected in Star , they need very high torque while starting of equipment. Else all LT motors are connected in delta. Still, I'll check for better results and revert ASAP sir. TQ
@durgeshkadu8181
@durgeshkadu8181 2 года назад
I want 440volt output voltage at 27HZ nominal frequency I have set I have set all parameters as per name plate data in para. 99 ... The voltage is still 415-420 volt output what should be done else for getting 440volt output at 27Hz freq output frequency.
@bishantkumar12589
@bishantkumar12589 2 года назад
I believe these drives are designed for 0-50hz frequency only with 0 Hz= 0 V and 50 Hz = 415V, But, you can change the minimum and maximum speed in the limit parameter, you will get the desired voltage at 27Hz. Try this, if u don't get, text me back
@durgeshkadu8181
@durgeshkadu8181 2 года назад
@@bishantkumar12589 I have checked in limit parameter 20 here min freq. I setted 0 hz and maximum 27hz then also output voltage is 415volt as I set 440volt nominal voltage in para 99...here I m not seems minimum and maximum RPM setting
@bishantkumar12589
@bishantkumar12589 2 года назад
@@durgeshkadu8181 what's the speed at 27Hz. ?
@durgeshkadu8181
@durgeshkadu8181 2 года назад
@@bishantkumar12589 currently I am testing without load and I seems voltage does not boosted to 440volt and I have tested 4pole motor with this parameter nominal voltage 440volt nominal frequency 27hz and motor design for 415v, 50hz due to motor gets overloaded at this stage even at no load .. It was trial at 4pole motor actually I want to test 440volt , 27hz , 12pole motor which is under production
@praveenkumar-uu6ht
@praveenkumar-uu6ht 3 года назад
How to ser drive parameter using vfd drawing
@rashadmuhammad8554
@rashadmuhammad8554 Год назад
How I can increase rpm hz settings while drive is running on profibus mode
@bishantkumar12589
@bishantkumar12589 Год назад
Sorry, I don't have that information. Pl contact your service engineer
@veereshh1824
@veereshh1824 7 месяцев назад
Dear Sir Drive is tripping on overcurrent fault. But actually no overcurrent, taking Normal current while tripping. Please suggest how to solve the problem.
@bishantkumar12589
@bishantkumar12589 7 месяцев назад
Put the drive to scalar mode and check veeresh Anna
@veereshh1824
@veereshh1824 7 месяцев назад
@@bishantkumar12589 Sir it is not Tripping immediately, it is tripping after sometime.
@veereshh1824
@veereshh1824 7 месяцев назад
How to set control Board temperature and it can Bypassed?
@omkarkumar5000
@omkarkumar5000 2 года назад
Sir abb ACS 1000 main water temperature reference setting kon se parameters group main milega please reply
@bishantkumar12589
@bishantkumar12589 2 года назад
Check kar k reply karta hu
@NICE_LIFE1986
@NICE_LIFE1986 2 года назад
Sir, I have Acs 800 drive how to speed control by Protections meter. Kindly share Basis parameters Acs 800 drive.
@bishantkumar12589
@bishantkumar12589 2 года назад
Ok sir. I'll in some time
@NICE_LIFE1986
@NICE_LIFE1986 2 года назад
@@bishantkumar12589 sir, Can your share mobile number? Pls
@aghashahzad460
@aghashahzad460 2 года назад
Bro kindly explain master slave parameter of acs800 kindly share
@bishantkumar12589
@bishantkumar12589 2 года назад
Ok sir. I'll surely try to work on it ASAP
@nikhilmishra3951
@nikhilmishra3951 Год назад
Sir acs800 vfd me encoder ko bypass kaise kre
@bishantkumar12589
@bishantkumar12589 Год назад
50.06 set internal estimate
@sujitsutar4953
@sujitsutar4953 3 года назад
Danfoss drive ka video kijiye.
@bishantkumar12589
@bishantkumar12589 3 года назад
Okay sir 👍
@sanjaykesarkar1918
@sanjaykesarkar1918 Год назад
Why can't given information about ID run. Its important Parameter.
@bishantkumar12589
@bishantkumar12589 Год назад
It's big topic sir and there's a complete separate video on it. U may check my ABB playlist for all the details
@PintuVerma-cv9uk
@PintuVerma-cv9uk 3 года назад
सर ACS लिखा हैं मॉडल मे उसका मतलब या फूल फॉर्म क्या होता हैं
@bishantkumar12589
@bishantkumar12589 3 года назад
ACS bus family group ka naam hai.
@user-nl4yc5vq3y
@user-nl4yc5vq3y Год назад
Assalamu alaikum Hamare pas ACS800 drive hay jes may group 99.1 se direct 99.9 pe chala jata hay motor data nahe araha parameter stat group 14 se ho jata please help Younas cherat cement
@bishantkumar12589
@bishantkumar12589 Год назад
namaste ... aapke drive me kisi ne parameters ko lock kar diya hoga... parameter number - 16.02 PARAMETER LOCK , check karo aap. agar 65535 hai too lock hai, 0 hona chahie.
@user-nl4yc5vq3y
@user-nl4yc5vq3y Год назад
@@bishantkumar12589 janab shukreya check kar ke aap se contact kar longa. Unlock ka koe pascode hay??
@bishantkumar12589
@bishantkumar12589 Год назад
@@user-nl4yc5vq3y ye too apke company ka incharge ya abb service engineer wala hi bata sakta hai kya set kiya hua tha
@bishantkumar12589
@bishantkumar12589 Год назад
agar aapko mere videos saahi lagte hai too please apne electrical dosto k sath v share kare is channel ko. thank you
@user-nl4yc5vq3y
@user-nl4yc5vq3y Год назад
@@bishantkumar12589 zaroor karonga
@9368737888
@9368737888 Год назад
How to reset complete parameter
@bishantkumar12589
@bishantkumar12589 Год назад
Factory reset can be done 👍
@earntechsv5384
@earntechsv5384 2 года назад
Moter stop hone ke bad reverse aa rha hai ky falt ho skata
@bishantkumar12589
@bishantkumar12589 2 года назад
Motor reverse run ho raha h kya ?
@earntechsv5384
@earntechsv5384 2 года назад
Ha sir rukne ke bad thoda reverse ghum rha hai kis parameter ka problem ho skata hai sir please tell us
@bishantkumar12589
@bishantkumar12589 2 года назад
@@earntechsv5384 pump application hai kya ?
@earntechsv5384
@earntechsv5384 2 года назад
Nhi sir EOT CRANE ME ABB ACS 800 DRIVE LAGI HAI USKA USE FORWARD REVERSE MOTION HAI USI KI PROBLEM Hai
@bishantkumar12589
@bishantkumar12589 2 года назад
@@earntechsv5384 okay main check karta hu
@vaibhavdave1016
@vaibhavdave1016 2 года назад
Sir hamare pass ACS 800 hai.. usme fiber optic thi mod bus ke sath hoke PLC ma communication jata hai.. Abhi fiber optic ka light thik hai fir fir bhi communication nhi mil raha or.. Eroor hi ata hai.. communication module 7510 vala
@vaibhavdave1016
@vaibhavdave1016 2 года назад
Parameters me bahut try kiya pr vo error nhi jaa raha
@bishantkumar12589
@bishantkumar12589 2 года назад
Check kar k bolta hu sr
@bishantkumar12589
@bishantkumar12589 2 года назад
ONCE CHANGE THE OPTICAL CABLE AND TRY TO OPERATE THE VFD
@Fire_palace
@Fire_palace Год назад
ABB ACS 800 vfd parameter UPLOAD & DOWNLOAD using Drive 🪟. Please make 🙏 a video please 🙏 Sir.
@bishantkumar12589
@bishantkumar12589 Год назад
Using HMI/CDP is available
@Fire_palace
@Fire_palace Год назад
Sir Drive window se kaise karte h uske procedure chahiye
@bishantkumar12589
@bishantkumar12589 Год назад
@@Fire_palace thode time me upload karta hu
@mdmasumbellah6487
@mdmasumbellah6487 Год назад
Sir how to contact with you...plz
@bishantkumar12589
@bishantkumar12589 Год назад
Pl ask ur doubt. Here
@shrikantha76
@shrikantha76 Год назад
@@bishantkumar12589 in my case I am getting fault in LT drive as ACS800 Temperature fault when we operate above 2nd step speed where as Temperature is normal inside E room. Please suggest what is the remedy? Thank you..
@mdmasumbellah6487
@mdmasumbellah6487 Год назад
@@bishantkumar12589 I want to send a problem video clip
Далее
Survive 100 Days In Nuclear Bunker, Win $500,000
32:21
ТЫ С ДРУГОМ В ДЕТСТВЕ😂#shorts
01:00
ID RUN - WHY DONE IN VFD ???
3:11
Просмотров 13 тыс.
ABB ACS880 VFD - IMPORTANT PARAMETERS : HINDI VIDEO
20:00
ABB ACS580 VFD - IMPORTANT PARAMETERS & SETTINGS
21:47
19. ABB ACS 800 Drive Basic Startup & commissioning
29:18
ABB INVERTER DRIVE ACS800 BASICS
9:31
Просмотров 4 тыс.
ABB ACS560 connection and Parameter Setting
8:55
Просмотров 90 тыс.
ABB Regenerative Drives ACS800
4:16
Просмотров 7 тыс.