Тёмный

NEST LEARNING THERMOSTAT INSTALLATION - How To Wire 

Allen Hart
Подписаться 125 тыс.
Просмотров 409 тыс.
50% 1

HOW TO WIRE , NEST LEARNING THERMOSTAT INSTALLATION Step by step guide How to install the nest thermostat via Opentherm and on / off connection , Boiler plus central heating control
Today we're going to talk about Boiler Plus and the Nest Learning Thermostat. What we're going to do is we're going to connect this thermostat up onto this boiler here. I'm going to show you the different connections on the Nest thermostat. This Nest thermostat, you can connect it on OpenTherm, and you can connect it on the normal on/off settings. We'll go through that. I'll go through setting up the display, so you can set it onto OpenTherm. Let's take a look.
As always, if you remove a case on a boiler, always make sure that you use a gas-safe registered engineer. We've isolated the power to the boiler, so we've got us Nest. Let's open it up. We've got us thermostat. We've got the instructions. We've got us Heat Link. That's what we're going to use to start with, wire us wires into this now. Also comes with a back plate, hard wire and also your plug. That's also got its screws in there as well.
If we look in the instructions on page 11, it tells us what all this is for. First of all, we're going to go through wiring for just a normal on/off thermostat. This will work on most boilers on the market, so most combi boilers. Then after we've done that, we'll go through the OpenTherm connections as well. You've got your neutral and you've got your live. Then you've got the ones that we will normally use for your link, which is number two and number three, which is there and there.
We've got us wires in there now for us link, which is number two and number three. Then when we look in the boiler ... On this boiler here, we've just took the link out and we've wired into that link there. As I say with this, always make sure you use a gas-safe registered engineer because you've got to go into the combustion area of the boiler. Also the person needs to be competent with wiring as well.
This is now wired up in the most basic form for this particular stat. We'll go through the different options further on in this video. I'll just show you settings on this. When you set this up, you need to go into equipment, and we'll go into pro set up. Continue. This is wired onto a combi boiler. At the moment, we're on on/off there. If we wanted to change that, we could click into it and change it, but for this one now, put on/off and we gas and then we radiators. We'll just click on continue. That's it, and that's done.
Now if we turn this up, the boiler will fire up. That's now us net and that's us nest on a stand, but you might want this nest to be fitted on the wall. What I'll do now is I'll show you how to wire it onto the wall as well and what we need to do for that. Then what I'll do is after that, I'll show you how to wire it via the OpenTherm as well.
With your Nest, you get a back plate. This is what you can fix onto the wall. On there, it's got some numbers which is 2-1 and 2-2. They connect back to the Heat Link, so what you've got to be careful is you don't put any voltage down this. If you wire this to 240 volts, 230 volts, whatever, you'll blow up. You need to make sure. You need to check it with multimeter checking the wires coming out and make sure that it's going to be safe.
Your T1 and your T2 are just here. These wires come from your stat and they're coming to your Heat Link. We've got us wires coming out of the wall. We've tested these wires now and we've checked that these are the wires that are going back to the Heat Link and there's no power coming down them. What I wanted to do now is wire this into this back plate. As we put this on the wall, this has got a little level on here so we can level it up, and it comes with some screws as well.
We've put the wires in now, and now we're going to put the thermostat on the front of it. I don't know if you can hear that clicking. Straight away, that's working. Now we'll connect it to OpenTherm and then we'll go through the display, and I'll show you how to set it up and set your boiler up, so your boiler will work on OpenTherm.
For OpenTherm, we need to move the number two and the number three and we need to put them into OT 1 and OT 2. We'll do that now. We've now moved the wires on here, and we're now going to do it at the boiler. This is the Baxi 600. For the Baxi 600, they go into these two connections here, these two black wires, so we'll do that now. We've just put us wires into there now.
All you need to do then, once you've wired it, is go into your settings, go to equipment there, continue. Pro set up, continue. Combi boiler, click into there. Set it to OpenTherm. Gas because we've got gas. You can put electric in there. You can put oil. We've got gas. Radiators. Then we've set this to 50 degrees. That'll make the boiler much more efficient. That's it. That's all set up. If your boiler is compatible with OpenTherm,

Хобби

Опубликовано:

 

7 июл 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 228   
@dshirali9970
@dshirali9970 4 года назад
I LOVE WATCHING YOUR VIDEOS ALLEN, I HAVE LEARNT A LOT FROM YOU! GOD BLESS YOU.
@AllenHart999
@AllenHart999 4 года назад
I appreciate that
@CommercialGasEngineerVideos
@CommercialGasEngineerVideos 4 месяца назад
God bless you too. He's a good teacher.
@Hermitmaster
@Hermitmaster Год назад
Allen this was so helpful, I have a basic boiler (no OpenTherm) and this confirmed what I assumed i.e. my NO and Common wires. Thanks!
@steverae5618
@steverae5618 Год назад
Great upload mate, you’ve just shown me how to get my thermostat off that silly desk mount. Perfect. Many thanks
@ArksE8
@ArksE8 6 лет назад
Thanks for the video. Keep them coming mate. ❤
@AllenHart999
@AllenHart999 6 лет назад
Thank you for watching buddy.
@Ivarposthumus
@Ivarposthumus 4 года назад
Great video. Beter then all the Nest documentation out there. Greetings from Holland!
@davidpeters2905
@davidpeters2905 6 лет назад
Thanks again for a really interesting video, 👍
@AllenHart999
@AllenHart999 6 лет назад
Thank you for your kind words and thanks for watching.
@techdorado
@techdorado 3 года назад
Allen - your video saved the day for me! thank you!!!
@AllenHart999
@AllenHart999 3 года назад
Thanks very much for your comment, please consider subscribing to support the channel 🙂
@normoliver133
@normoliver133 Год назад
Allen, class videos bud. Keep them going mate they genuinely help when you are unsure of stuff. Just wiring in my first nest so this vid puts my mind at rest. Perfect
@chengambj
@chengambj 5 лет назад
Hi Allan H, Could I have outdoor weather sensor and the nest system using open therm working together or would they both conflict with each other as they both override manual temperature control. Maybe I could have nest in basic on/off mode and outdoor sensor. My combi is Viessmann 050w. Any advice would be greatly appreciated. Thanks
@davidroche6973
@davidroche6973 3 года назад
Your a god send, thanks mate 👍
@mrsayef1059
@mrsayef1059 6 лет назад
Love this video if only you uploaded this few weeks ago when me and nest techniqual support team on the phone both confused at the same time lol
@AllenHart999
@AllenHart999 6 лет назад
The nest is very easy to install once you get the hang of it, Thanks for watching.
@taludoka
@taludoka 4 года назад
Thanks Allen for your video. I own an old wood boiler for heating, which was adapted to work using a pellet burner (Blaze Harmony XS26). The Pellet burner doesnt support OpenTherm, but it does support regular on/off thermostats. The Room thermostat connector on the control panel supports less than 12V. Would Nest Thermostat work for me by connecting 2 and 3 (on Heat Link) to that two wires connector? Also in this video you wire Heat Link to the Thermostat, but can those two work together wireless?
@Kipsass
@Kipsass 3 года назад
Thanks for a interesting video
@RoobieRoo2
@RoobieRoo2 Год назад
cheers Aldo, vid was 2 awesome.
@anthonyschofield7807
@anthonyschofield7807 2 года назад
Many thanks Alan, I am going to connect a Gen3 to my Open therm boiler but wouldn’t have known about the change required in the settings but for this
@Molinacaveman
@Molinacaveman Год назад
Where do I get the power cable from to connect to the thermostat?
@joekane23
@joekane23 3 года назад
Clear and concise as usual Allen I’m wondering if nest would be compatible with vitodens 050 combi boiler I’ve just had one installed can’t get the supplied stat to work with it
@Gollammeister
@Gollammeister 5 лет назад
Nice video as always
@AllenHart999
@AllenHart999 5 лет назад
Thank you for taking the time to watch my video.
@ChrisDuffy_82
@ChrisDuffy_82 4 года назад
For an opentherm boiler setup, does the live and neutral going to the heat link come from the boiler, or it’s own, separate source?
@petertaylor6369
@petertaylor6369 3 года назад
Hi Allen, I've tried to read through all comments and I can't find anyone mention about the Ideal Logic + combi, where if you are using open therm you have to reinstate the link on the room stat in the boiler wiring to get it to work.
@MsNazo
@MsNazo 4 года назад
Always very knowledgeable video,thanks for sharing your knowledge with all of us, I have a request ,can you show us how to change pipe work ,when we change tank system to combi boiler,plus megaflow system pipe work and wiring, thanks
@AllenHart999
@AllenHart999 4 года назад
Will sort one for you soon. Keep asking as i forget 😂👍
@imranmajid1978
@imranmajid1978 4 года назад
Excellent video - but please can you explain what opentherm is and what boilers have them. Also, what is the benefit of using opentherm over the regular setup?
@the_judge_8262
@the_judge_8262 3 года назад
Why aren't all videos this simple and clear to understand👍🏼 Thanks Allen
@AllenHart999
@AllenHart999 3 года назад
Thanks very much for your comment, please consider subscribing to support the channel 🙂
@the_judge_8262
@the_judge_8262 3 года назад
@@AllenHart999 Done. Would you be up for doing a similar video for the Nest Thermostat E. Much cheaper and far more effective if you just want to control hearing instead of water too, plus supports learning etc
@AllenHart999
@AllenHart999 3 года назад
The_Judge_ I will definitely look at that. No problem
@sgttruce9996
@sgttruce9996 3 года назад
Thanks for the vid. Quick question; if you use the table standard; do you still need to connect the nest to the heatlink via a wire? Or does this go wireless? Because you only showed to connect the thermostat to the headlink when you put the thermostat on the wall? Thanks for the reply in advance:) Cheers!
@raymajrowski8046
@raymajrowski8046 6 лет назад
Thanks Allen, great simple instructional video, as I have not fitted boiler plus yet, I was concerned with what to do best for my customers. The baxi IFOS weather compensator seems cost effective and easy to fit, thanks again. Gas Safe Engineer 503644.
@AllenHart999
@AllenHart999 6 лет назад
I did a video on the baxi ifos, have you seen it. ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-_8rotUM1e90.html
@LordJasonKing
@LordJasonKing 3 года назад
Alan, thanks mate. Just to ask will it connect to the heatlink wireless if its wired to to t1 & t2? Having a nightmare connecting jepp getting error code n80.
@cliftonpoynter388
@cliftonpoynter388 6 лет назад
Hi Allen, when wiring open therm and removing wires from basic wiring on boiler to open therm connections do you put link back between original stat connections on terminal block at boiler?
@gman5375
@gman5375 3 года назад
Great video mate cheers!
@AllenHart999
@AllenHart999 3 года назад
Thank you! Cheers!
@gman5375
@gman5375 3 года назад
@@AllenHart999 I’ve actually got a local guy in at the minute working at my install and he used this video as a quick reference! Thanks so much...I’ll give you an address for the invoice 😆
@PilotLyons
@PilotLyons 4 года назад
Hey Alan, great vid as always... I have the older logic plus, currently have the PRT 4 (or 3 not sure) can you tell me how I do the opentherm set up on this? The opentherm works really well on the PRT but wanted to upgrade to nest (as we have nest protects too)
@24-7ttplumbingheating4
@24-7ttplumbingheating4 4 года назад
another good video
@jasushaw
@jasushaw 4 года назад
Hi Allen Just installing a 2 zone gas boiler with motorised valves. I have wired heating for standard thermostats. So from my isolater to junction box with motorised valves and a feed up to boiler. With the heat link do I wire my motorised valves into the heat link and use it as my junction instead or what way? First time using Nest stats
@benalexlily
@benalexlily 3 года назад
Hi Iv got an ideal boiler looking to change the wiring on the nest to opentherm but I have a underfloor heating wiring center do I need to move any wiring in there for the opentherm to work with the nest and the boiler of just leave it as it is but move the wiring in the boiler and nest
@misssimmi2
@misssimmi2 3 года назад
Hi, I've just had a new baxi 40kw platinum boiler installed with the nest learning thermostat. It's on on/off mode and I watched your video and tried to put it on opentherm but I get a message saying couldn't detect opentherm connection. Check your settings. What am I doing wrong? Also, what would I need for it to detect outside temperature to adjust the heating accordingly in order for it to be more efficient? Thanks
@jamiescrimshaw2143
@jamiescrimshaw2143 4 года назад
Would it be possible to use a nest stat if I have a 3 core and earth cable at the current stat? The boiler is on a 3a fuse Thanks
@Daisy-ef6bq
@Daisy-ef6bq 4 года назад
Is the heatlink & thermostat compatible with a WB heatslave II 18/25 External oil combi?
@michaelgrant6920
@michaelgrant6920 5 лет назад
A Wire Classic!
@AllenHart999
@AllenHart999 5 лет назад
Wired is always best if possible. Thanks.
@ashhammond
@ashhammond 4 года назад
Allan - do you know the wire gauge need between the heatlink and stat? I know it's only 12v.
@MuhammadAdeelAhmed
@MuhammadAdeelAhmed 3 года назад
Thanks Allen , very nicely exxpained, is it possible you can advise how to connect Nest Thermostat with logic esp1 C35 combi boiler ? I am looking to connect with Opentherm. Boiler already has ESI thermostat attached which is programmable but I want to replace it with Nest 3rd gen.
@PereiraShane
@PereiraShane 2 года назад
Love your videos great to know some quality information. 👌 I want to ask you recently I got viessman 100w combi boiler and using nest smart thermostat with it. Technician said nest is not compatible with open therm. 😑 but looking at this video it is compatible. Can I ask do I need to change the wiring in the veissman boiler or can I change the wiring on nest module and then that should do ?
@derekhealy9603
@derekhealy9603 5 лет назад
Hi mate, how does the thermostat work when you just want hot water for a shower and do not want the radiators on, is there an option for this? At the moment I have a switch on my combi boiler for: Hot Water or Hot Water + Radiators.
@stealthstyle1
@stealthstyle1 3 года назад
Do you need to connect 2 and 3 if you’re using OpenTherm ot1 and ot2?
@2522james
@2522james 2 года назад
I have a wire from my thermostat going straight into boiler on LS and LR, so do i have to put this wire into heat link and on what connection then wire heat link into boiler? On ls and lr?
@nathanmoor9721
@nathanmoor9721 3 года назад
Hi Allan, I'm just wondering if you have had any experience with Opentherm with nest and a s plan heating system? Can't find anything that can give me guidance on this, even Ideal technical didn't clear it up
@drajcoshi
@drajcoshi 3 года назад
Hi mate I had a new boiler fitted in ideal vogue max combi 40. I had the boiler engineer fit the nest thermostat as well. But for some reason the thermostat can’t be used to bring the heating on. The thermostat is connected to the heat link, I am getting hot water on demand. But the radiators work if I turn nest off to go manual heating. Can you advise on what is wrong? Is it the wiring?
@adrianoreilly9846
@adrianoreilly9846 3 года назад
Hi Allen When using open therm do you replace link removed earlier thank you
@mmanzi1117
@mmanzi1117 6 лет назад
Hi Allan thanks for the video. I had my Nest installed a few months ago. The technician said that I couldn't get rid of the old VRT340f thermostat and that I needed to keep it on 24hs and the Nest would over ride it. The problem is that I find myself waken in the middle of the night with the heating full on despite the Nest not being set to be on. Somehow the old VRT340f overrides the Nest at that time. Please help. Thank you
@AllenHart999
@AllenHart999 6 лет назад
its hard to comment without seeing the job but i would of thought it would be possible to remove your old control.
@r0binx
@r0binx 4 года назад
Is there any way to use two nests (multizone) with opentherm?
@Iceblizzard
@Iceblizzard 4 года назад
Another brilliant video Alan you should have been a lecturer.I have a problem I have just purchased a Nest thermostat which now are sold without any wires included in the product.Have you any idea what kind of wire I need to buy to wire the thermostat to the heat link. ?
@manoloyanes8206
@manoloyanes8206 3 года назад
I noticed in your wiring you did not use the earth wire on the heat link, isn't that required?
@davidjames4457
@davidjames4457 4 года назад
Do you need to use the earth on the heat link, if you are just using on/off stat?
@Sound.wave_
@Sound.wave_ 2 года назад
My existing honeywell unit on the wall which controls the central heating has the blue brown N/L and the grey and black, so I assume I can wire just as you did. Blue in neutral, brown in live, grey in 2 and black in 3? The thing confusing me is in that the other videos I have watched the are also additionally looping the L and number 2 connector, why?
@shorts92994
@shorts92994 4 года назад
Hi, I have an old boiler + tank and I have the connection as in the picture. You could write me how to translate it to nest please
@hownot2mill561
@hownot2mill561 2 года назад
Could I connect one of these to my old Potterton Suprima 100? Thanks
@erniebrooks2400
@erniebrooks2400 4 года назад
Allen do you have a video of this system on a vaillant ecotec ?
@BillyBufter
@BillyBufter 5 лет назад
I had mine installed by nest however they've wired the water and the heating the wrong way round. Can I fix this? Because I'm red hot!
@AllenHart999
@AllenHart999 5 лет назад
did you manage to sort it. Thanks.
@antonyhawkridge3237
@antonyhawkridge3237 3 года назад
Hi I have a alpha 18 boiler and a immersion tank Will this run both
@jamesclarkson9902
@jamesclarkson9902 2 года назад
Hi Allen, my Nest seems to have stopped turning my CH on on my Ideal Vogue Max 32, tried resetting the Thermostat and the Heat Link to no avail. Any ideas, or should I call a plumber? Cheers, James in Wakefield
@smcelv
@smcelv 6 лет назад
Hi Allen. I've been searching for a while now but still not sure if the Nest system will work with my oil fired heating? I only control it with a 7 day programmable wall mounted box. I was hoping that the Nest system would just replace the 7 day timer?
@AllenHart999
@AllenHart999 6 лет назад
Sam McElveen If you buy it from the nest store you can also book an installer, they will sort it for you no problem
@imranmajid1978
@imranmajid1978 6 лет назад
It's worth mentioning that the thermostat can be mounted without cable connection to the heatlink, in such a scenario it's powered by the USB cable/plug included within the box.
@AllenHart999
@AllenHart999 6 лет назад
Yes thats a good point, thank you for your input.
@benson3000able
@benson3000able 5 лет назад
Can I have it connect on the stand and still have it connected via opentherm
@explorer47422
@explorer47422 5 лет назад
The nest I received didn't come with a plug - like it was designed to be sent without one. I don't understand how it can be powered?
@czondag
@czondag 4 года назад
@@explorer47422 i think it will be powered and send data through L1 and L2 cables to the heatlink, and the heatlink will send the orders to the heating system. If you don't connect it to the wall you have to buy a stand with usb power connector. The data in that situation will be send my mesh connection to the heatlink, Only thing i'm not sure about is what the range will be through two concrete floors which is very common in the netherlands.(europe) many times the heating system is placed on the attic.
@kelvinellis8312
@kelvinellis8312 5 лет назад
Good video Alan can you do a video showing how to connect to heat only boiler with dhw as well
@AllenHart999
@AllenHart999 5 лет назад
I will try when i come across one. Thanks.
@bojantrafela9881
@bojantrafela9881 4 года назад
Hi, one question: Can I install Heat Link using just TWO wires, that my current thermostat is using to power on my heat boiler (Electric Central heating). Basically, current thermostat, sends a signal when heat is needed, everything else done by the electric boiler. Thermostat is battery powered, but live wire (220V) is connected to it. This wire goes directly to my electric heater. If this is possible, which two connectors on the Heat Link should I use, and do I have to "jump" any of the connections? I know that there is a NEST E thermostat on the market which is design to replace my current thermostat, but I would like to use 3gen on my system, because it will give me wide options if I decide to change my boiler.Thank you for the answer.
@tozguitar
@tozguitar 4 года назад
What guage wire do you need to go from the heatlink to the wall mounted stat? ie the 24V
@AllenHart999
@AllenHart999 4 года назад
i think it’s around 7v or something like that, bell wire should be ok. Thanks.
@abaidsajjad
@abaidsajjad Год назад
On the dial when you connect T1 & T2 do you have to give power also with micro usb or no. On my wall fixing plated it has t1 t2 also micro usb port. Thanks
@chriscarr365
@chriscarr365 Год назад
No, it'll be powered by the heatlink
@Zomartov
@Zomartov 4 года назад
What's mean 'Supply' in Settings -> Equipment -> Nest PRO menu? I can't find any info :( Is it maximum target temperature on System delivery? Or target temperature on System return? Or supply cold water to Boiler? What is it? Why did you set it to 50 degrees? Help pls.
@atif6843
@atif6843 4 года назад
I have a ideal logic C30 is that opentherm?
@emerictassel9064
@emerictassel9064 2 года назад
Awesome
@ryanlove2682
@ryanlove2682 Год назад
So it’s 2 and 3 wires from stat to boiler ? I wiring a alpha 28 e tech
@ericthekingthekingtheking4842
@ericthekingthekingtheking4842 4 года назад
How do you link it to the app on your smartphone allan so you can control it from outside the home etc
@fattoamanowoodwork3638
@fattoamanowoodwork3638 Год назад
Good afternoon good man, thank you for all your videos. Really appreciated. Would it be possible to run something pass you (paying of course) if I may? I'm quite confident but Id rather not do any mistake. I have the installation guide but I'm not sure about couple of things.
@mariusradu9519
@mariusradu9519 3 года назад
Hi, Nest control the Wather temperature From radiators ? Thanks
@eoinstakelum2590
@eoinstakelum2590 3 года назад
At 3:19 what is the nest connected to for power etc? Is it wired back to the link?
@TonyNeat
@TonyNeat 4 года назад
The glaringly obvious omission with my Nest thermostat is the option to choose just one hour of heating. I used that often on my old controller if I was up late on a weekend evening. You know those those occasions where the heating’s turned off according to schedule then you feel the slight chill an hour later? The one hour button was perfect for those occasions. Now I have to turn the thermostat up to get the heat working again. Not difficult I know but the amount of times I’ve woken up in the early hours, melting in my bed, because I forgot to turn it back down ☹️
@Episode_13
@Episode_13 7 месяцев назад
Hmmm? You need to set the temp. That is normal
@TonyNeat
@TonyNeat 7 месяцев назад
@@Episode_13 I think you missed my point. Maybe read my post again.
@mikeuk8486
@mikeuk8486 3 года назад
Hi mate how nest compere with Hive? I don't have any thermostat so how do I connect Nest? It means it's not wireless?
@ValCustom
@ValCustom Год назад
Hello, please let me know how to install 2 nest . One upstair and one downstair. My nest is not turning on the heating. I can control to turn off only . I turn on manually . Many thanks
@seanhoward8968
@seanhoward8968 2 года назад
Is this wiring the same as a Baxi combi instant 80 HE? Thanks
@TheWojciu
@TheWojciu 4 года назад
Hi is any chance to control electric under floor heating
@peterbodi3870
@peterbodi3870 Год назад
Hi Allan I would like to ask you Ive got 20 years old combo boiler Do must to install that with box link to the boiler? Ive got only 2 wires at my old thermostat My question is can it works woth that 2 wires cable ? Its got 30v i tested Or must be install that with link straight to the boiler ? Thanks Thsnks
@stephenrobinson2086
@stephenrobinson2086 3 года назад
Hi Allen. Please can you advise me. I have always wired a boiler switched. I want to use opentherm. Do I do away with the switched connection and put a link back in the boiler before connecting the 2 core to opentherm?
@harrybouch7907
@harrybouch7907 Год назад
I have the same question and can't seem to find an answer anywhere
@ashley758747
@ashley758747 6 лет назад
Great video, I’ve just had a nest installed to an Ideal Logic+ via Opentherm, when setting the radiator temperature on the boiler should this be the same as the supply temperature on the nest thermostat? Cheers
@AllenHart999
@AllenHart999 6 лет назад
if you set it around 50 it will save you more money, The downside is it will take longer to heat up. Its a balance really and will depend on the property and also the heat loss. Thanks for watching.
@TimMorley
@TimMorley 6 лет назад
I have the logic plus too. If connected with openthem (as we both are) the setting on the nest for the flow temperature overrides the boiler setting. This is the same too for the hot water temperature. Setting the flow temperature on the nest at only 50 defeats the point of openthem control. (Sorry Alan!). Set this higher, on a cold start the flow temperature will be much higher for a short period and get the house temperature increased faster; as the room temperature get closer to its target the flow temperature is reduced anyway
@mckperera
@mckperera 4 года назад
Does the t1 and t2 provide permanent power to the thermostat as well. I.e. so you don't need to have a usb connection to charge the thermostat?
@AllenHart999
@AllenHart999 4 года назад
T1 and T2 are power yes. Happy new year. Thanks.
@sshaunss
@sshaunss Месяц назад
Cheers man looking into one of these. If there is no power going to the thermostat won’t the battery inside die after a while ?
@builditontutorial
@builditontutorial Год назад
hi i have a issue i have the N and L wire but the third wire is with 2 color yellow and green where should i connect it
@k00baa
@k00baa 7 месяцев назад
Great video, Allen. Question- for opentherm, does the link between 2&3 on the boiler should be removed or inserted?
@markschofield2118
@markschofield2118 4 года назад
Hi, what is the typical install costs from a gas safe engineer?
@LordJasonKing
@LordJasonKing 5 лет назад
Would you always choose open therm over simple on off with the nest?
@AllenHart999
@AllenHart999 5 лет назад
Depends on the boiler and the system but i do like Opentherm. Thanks.
@LordJasonKing
@LordJasonKing 5 лет назад
@@AllenHart999 its Vokera i36 Unica. It modulates when wired off/on in the right setting (heat range). I fail to see the difference with open therm with a modulating boiler. Does it 'grumble in the background keeping it at a set temp?
@Molinacaveman
@Molinacaveman Год назад
Where can I get the cable from to hard wire it onto the wall? 12v DC cable?
@maxmerton
@maxmerton 2 года назад
I'm curious that you call the area where the boiler terminal blocks are "the combustion area". What do you call the area where combustion actually takes place?
@Gollammeister
@Gollammeister 5 лет назад
Is it worth having a remote control system for switching on heating ?
@AllenHart999
@AllenHart999 5 лет назад
Personal choice really. Thanks.👍
@ALG1K
@ALG1K 4 года назад
Could you turn the volume up a little on the next vid 👍
@AllenHart999
@AllenHart999 4 года назад
Check out some of my new videos and let me know if they are any better. Thanks.
@ian1104
@ian1104 4 года назад
Hi Alan when the thermostat is wall mounted where does it get its power from
@AllenHart999
@AllenHart999 4 года назад
Ian needs to be hard wired, or plugged in. Thanks
@squidiebah
@squidiebah 4 года назад
You know if the Isar HE35 supports this with opentherm?
@AllenHart999
@AllenHart999 4 года назад
I do not believe they do. Thanks.
@ivanlongo8725
@ivanlongo8725 4 года назад
Hi Allen , can you make 2&3 live with a link on them
@Episode_13
@Episode_13 7 месяцев назад
Where does the nest get the power from? When ob stand? Why is a plug provided?
@awsaldulaimi9137
@awsaldulaimi9137 5 лет назад
hi there ,, i have bought my nest 3rd gen from a guy on facebook but it came not opened but without a USB cable nor a brick for it is that normal ?
@bobwhittaker4433
@bobwhittaker4433 3 года назад
yes that's normal, cable and charger £10 on ebay
@marcelwrona779
@marcelwrona779 5 лет назад
Hey how you wired and install the heat link to have option controle you hot water?. Please great wideo
@AllenHart999
@AllenHart999 5 лет назад
This was heating only on this one. Thanks.
@marcelwrona779
@marcelwrona779 5 лет назад
@@AllenHart999 but you can have that option witch boyler? How and when you install that option?
@Lydia_Sun
@Lydia_Sun 4 года назад
I have 2 thermo control in my house. One in downstairs.another one in second floor. Which one shall I install ?
@AllenHart999
@AllenHart999 4 года назад
you may need two. I have one for upstairs and one for down at my house. Thanks.
@Lydia_Sun
@Lydia_Sun 4 года назад
thank u
@jaslidder250
@jaslidder250 4 года назад
Since my gasman connected Nest 3 to Ideal s24 system bolier via OT connection the hot water stopped heating my hot water system. I do have a hot water cylinder. Any idea why water stopped heating via my Nest schedule?
@pragrane
@pragrane 4 года назад
HiAll, is there any wiring information available for connecting logic heat H15 with Nest 3rd Generation? I am struggling to find any. Thanks in advance.
@pragrane
@pragrane 4 года назад
@@UrbanPlumbers Thanks for feedback. I'll check
@bimiuk4051
@bimiuk4051 2 года назад
Hey Allen Been recommended an Ideal Vogue system boiler with HIVE thermostat!! Research show that HIVE is not really that smart and say NEST is best choice. Now my worry of NEST installation is possible on the suggested boiler and if that will add additional installation fee? By the way which model of Nest do I need to go for? Also, how many thermostat will I need for my town house (two floors + ground floor). Pls advise
@AllenHart999
@AllenHart999 2 года назад
Ideals own control makes really well with the vogue
@bimiuk4051
@bimiuk4051 2 года назад
@@AllenHart999 sorry you confused me here. I thought VOGUE is the model of the Ideal (being the make)?? Question is; Nest vs Hive ?
@Yugo.driving.school
@Yugo.driving.school Год назад
Got a new boiler installed and he’s not wired it correctly. Can only turn heating on if I turn the water on first, so thermostat doesn’t work otherwise
@djevil247
@djevil247 4 года назад
Got the same wera maintenance kit, how’s yours attached to the wall?
@AllenHart999
@AllenHart999 4 года назад
I have put a screw through it 😂😂😂😂😂Happy new year. Thanks.
@djevil247
@djevil247 4 года назад
Allen Hart That’s brilliant, thanks Allen. Happy new year to you to sir.
@normanboyes4983
@normanboyes4983 6 лет назад
Looks straightforward - if your boiler is compatible.👍
@AllenHart999
@AllenHart999 6 лет назад
Very easy indeed, Thanks for watching.
Далее
Впервые дал другу машину…
00:57
skibidi toilet zombie universe 34 ( New Virus)
03:35
Просмотров 2,6 млн
PB Plumber Nest Thermostat on a Y Plan
22:44
Просмотров 44 тыс.
LEEDS PLUMBER - NEST THERMOSTAT INSTALLATION
12:16
Просмотров 147 тыс.
Fixing another Nest heat link - with easy tests
13:39
Просмотров 106 тыс.
Fixing a completely dead Nest thermostat heat link
19:07
Installation Nest Heatlink en français
9:48
Просмотров 42 тыс.
How To Wire | Tado Smart Thermostat | Combi Boiler
18:44
Fix Nest Thermostat Issues by Installing a C Wire
8:54