Node-Red And Victron - Introduction and Grid Setpoint Solution 

HmT Distribution
Подписаться 306
Просмотров 537
50% 1

Опубликовано:

 

23 окт 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 2   
@mareksznura9323
@mareksznura9323 3 месяца назад
Dear Dylan, I also have MultiPlus-II and I can't use "Multi RS Control" because the system told me that there is no multi rs services available:( I don't know why. I tryied to use grid set-pint to use power of my inverter (3kW) and in case of pick power, power from the grid will be used, but it didn't work:( do you have experience with grid set-pint option?
@hmt-distribution
@hmt-distribution 3 месяца назад
Hi There, good question! If you are using a Multiplus-II then you will need to use the "VE.Bus System Control" node and not the "Multi RS Control". The Multi RS Control node is for Multi RS inverters only, which is what i was using for this video as a DEMO installation. Look at replacing the "Multi RS Control" node with the "VE.Bus System Control" node in your flow and keep everything else the same.