Off Grid Tip: Using the Chargeverter GC & 6000XP In Tandem? 

East Texas Homestead
Подписаться 17 тыс.
Просмотров 4,4 тыс.
50% 1

Опубликовано:

 

5 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 31   
@user-jn4wn1ut4h
@user-jn4wn1ut4h Месяц назад
Chargeverter seems like a great option. Thank you for the video! The thing that concerns me is I have to unhook my 6000xp from my batteries to use the charge converter. If I set up an automatic system, I don't want to void my warranty by making my depth of discharge < 20%. The 6000xp inverter is protecting me from dropping too low on my batteries.
@branch_ranch
@branch_ranch 2 месяца назад
Thanks for the chargeverter updates. I recently got my cabin set up with 1 EG4 6000xp and indoor wallmount battery set up with the chargeverter. My harbor freight 3500 genny does well enough until i get my 8 ground mount panels up and going. Nice to see others with the same setup, keep the vids coming!
@EastTexasHomestead
@EastTexasHomestead 2 месяца назад
It's a rock-solid system. Glad to hear it's working well for you, too. I've been wanting to try the wallmount batteries. Maybe someday soon :)
@clintclark89
@clintclark89 Месяц назад
Great topic. I have watched a few other videos on the chargeverter to research before I buy. None of the other solar youtubers have even mentioned the potential issue of not being able to charge with the chargeverter while discharging through the inverters (running in tandem). I was under the impression you could hook up a generator with dry contacts to communicate with the chargeverter to start whenever certain parameters that you set are met. I never even thought to question whether you could use the inverters with the chargeverter in tandem. Glad to know it can be done.
@EastTexasHomestead
@EastTexasHomestead Месяц назад
It only makes sense because it can auto-start a generator. However, the manufacturer apparently had some concerns at first.
@sciglassblower
@sciglassblower 2 месяца назад
It's not just the dirty electricity from the generator. You would have to hook up the generator to All The 6000XP's! The Inverter's will switch to charge mode running all the load off the generator and charging batteries with what is left over, but there is More! You CANNOT run different generators on each 6000XP because they would not be phase matched. You would have to have a huge generator if you have large loads running. This Must Change for EG4 and others to meet the needs of the market. Put a REAL CARGER inside and stop using the inverter to charge! I have 2 ChargeVerters so I can run 2 Normal Inverter Generators Not some Huge Insane Expensive Loud Fuel Guzzling Large Generator! Oh yeah, and they put features in the ChargeVerter that you cannot use like communication that will not work if your batteries are communicating with the Inverters which is Always the case! And Generator Auto Start that inexpensive smaller Inverter Generators which don't have batteries and starters cannot use! You only need 5000k to 6000k continuous output Generator to max out the ChargeVerter and very few Inverter Generators of this size have starters and I don't want starters with additional maintenance and problems! Inverters Generators can run at or near 100% just fine because the output does not become unstable as on non-inverter generators and in my experience Inverters Generators do not run as high RPM at full load so they are not working at full motor capacity at full output. I was incorrect about my ChargeVerters! They do cause the 6000XP's to restart! I wrote EG4 about this Very Wrong Issue! Who wants the Inverter Output to ShutDown when you start your ChargeVerters? Ridiculous!
@JBoy3210
@JBoy3210 Месяц назад
Major issue if you have servers running.
@AndirHon
@AndirHon Месяц назад
@@JBoy3210 Super annoying, but I would have my server/routers on a UPS of their own in case I need to get to something if the power is having issues.
@northidahodreaming5657
@northidahodreaming5657 2 месяца назад
Thanks for the look into your setup. I have 2 6000xp and 6 lifepower4....not running yet. Good to learn from others.
@EastTexasHomestead
@EastTexasHomestead 2 месяца назад
Sounds like we have the same base components. :) I've got a full install video that may be helpful. I'm also about to put out another video that is a bit more in-depth than this one but less than the full install. You can do this!
@chrisfair9228
@chrisfair9228 2 месяца назад
Lost a lot of trees on the property but only slight damage to our shed. Over the 2 weeks of storms we ran off whole house generator for 76 hours. Made me finally order Starlink since our ISP was out even longer than the power. Not yet convinced we need to go battery backup since in 2 years these have been our only significant outages and it looks like our propane can run our generator for 7-10 days before needing a refill. If we move we will likely put in solar and battery backup systems.
@EastTexasHomestead
@EastTexasHomestead 2 месяца назад
That was a crazy couple of weeks. Good to hear your generator kept things going. It's a nice prep, for sure. It's tough to justify the battery backup for emergencies when you have the generator. I'm glad you ended up getting Starlink. How's it been working for you?
@chrisfair9228
@chrisfair9228 2 месяца назад
@@EastTexasHomestead Lets just say my cable company is loosing me as a customer this week after a 3 week trial of starlink. Sad when a satellite internet company is more stable than a cable company.
@EastTexasHomestead
@EastTexasHomestead 2 месяца назад
😬 my long-held position has been that if you can get cable, then you should stick with cable, but that might change based off of your experience.
@robertbutler1986
@robertbutler1986 2 месяца назад
I currently power my cabin with a NEMA SS2-50P inlet wire to my 240 electrical panel and a 50 amp Rv extension cord running to the generator. Can I wire the NEMA SS2-50P plug directly to a nema l14 30p plug that connects to the chargeveter?
@EastTexasHomestead
@EastTexasHomestead 2 месяца назад
No. This would not work. The Chargeverter is strictly for charging 48-volt batteries, which use DC power. Your 240-volt cabin runs on AC power (the same as your generator). If you’re looking to get clean energy into your panel, the best thing would be to get a generator with an inverter built in. This will put out a pure sine wave (clean AC power). Thanks for asking!
@all4amd344
@all4amd344 2 месяца назад
I figured this would be ok. External solar charge controllers are wired parallel to the batteries to charge them while drawing from them.
@EastTexasHomestead
@EastTexasHomestead 2 месяца назад
I was thinking the same thing. I built out a Victron system that did it like that.
@roslynandbobchauvin2378
@roslynandbobchauvin2378 9 дней назад
I'll be setting up an 18kPV, wondering how well it'll work with a generator. Would like recommendations for generators that are compaitlble. Midnite Solar's new All In One is supposed to be more forgiving re power quality.
@EastTexasHomestead
@EastTexasHomestead 9 дней назад
To be clear, you're talking about running directly into the generator port on the 18Kpv, right? Assuming that's the case, I took a quick look at HomeDepot, and there are a few options, but you're going to have to spend a lot. I'd probably go with something like the Champion 12,000-watt generator in order to hit the specs needed. www.homedepot.com/p/Champion-Power-Equipment-15-000-Watt-12-000-Watt-Electric-Start-Gasoline-Powered-Portable-Generator-with-CO-Shield-with-50A-Transfer-Switch-201405/328602592 The 18Kpv requires a 240v (two hot wires) input from your generator, and EG4 recommends that the generator have between 6,000 and 21,600 watts of output. See page 22 of the manual: eg4electronics.com/wp-content/uploads/2024/04/EG4-18KPV-12LV-Manual.pdf?ref=esttxthst In my opinion, it's easier and cheaper to get a smaller generator and run it through the Chargeverter. That way you can charge with 120v or 240v and use a lot less fuel.
@roslynandbobchauvin2378
@roslynandbobchauvin2378 7 дней назад
@@EastTexasHomestead I think that is good advice. I see the inverters can be damaged by a bad generator, so $500 might be good insurance, allow a cheaper genny, and add flexability. Thank you!
@EastTexasHomestead
@EastTexasHomestead 7 дней назад
@@roslynandbobchauvin2378 You bet!
@basspig
@basspig 2 месяца назад
I use a pair of the original yellow eg4 charger. And I don't have those issues when I switch on the chargeverter. It's operation is totally transparent and behaves just like Powers coming from solar input.
@EastTexasHomestead
@EastTexasHomestead 2 месяца назад
I have an old yellow one as well, and you're right. It didn't do that. I'm going to have to do some testing now.
@basspig
@basspig 2 месяца назад
@@EastTexasHomestead I have a pair of them. They survived a lightning strike to my solar array this afternoon while the generator was running and charging batteries. A Sungold Power 6kW inverter was also being used as a charger and it went up in smoke.
@EastTexasHomestead
@EastTexasHomestead 2 месяца назад
Oh man!!! I’m sorry to hear that. 😢
@basspig
@basspig 2 месяца назад
@@EastTexasHomestead I think I got lucky in that my SC4880 charge controller connected to that string did not die. It doesn't work anymore because there's only 10V coming in from the array now. Bypass diodes must have all shorted in the 20 panels in that array.
@EastTexasHomestead
@EastTexasHomestead 2 месяца назад
I'm glad it didn't take it all out. But man! what a bummer