Optical Coherence Tomography Basic Explanation 

Zach Nadler
Подписаться 571
Просмотров 146 тыс.
50% 1

A very introductory look at Optical Coherence Tomography (OCT), an imaging technology used in medicine.

Опубликовано:

 

10 мар 2015

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 57   
@linafessi67
@linafessi67 3 месяца назад
This litterally the best video i saw on youtube to understand what OCT is, in a more physical way. Thank you soooo much!!
@linamarcelapinedagutierrez4650
Thank you for the tutorial, it has helped me a lot since it was kind of hard to understand this written on a book.
@JoelSchuman
@JoelSchuman 9 лет назад
Nice work Zach! We're looking forward to great things!
@MrWabouz
@MrWabouz 4 года назад
Too bad you rushed it in the end... I'm familiar with Michelson interferometery but you really went to quickly on the reason why I clicked on this video: explaining exactly how we build the image layer by layer...
@davidmusoke
@davidmusoke 5 лет назад
Great tutorial Zach. Thank you!
@anjham
@anjham 6 лет назад
outstanding and to the point. well done zach
@samanmonazami9156
@samanmonazami9156 4 года назад
Nicely explained! Thanks Zach!
@warnacokelat
@warnacokelat 8 лет назад
Saved me a lot of trouble. Thanks a lot.
@acousp4515
@acousp4515 4 года назад
What a perfect mouse control!
@anooptiwari2011
@anooptiwari2011 2 года назад
Simplified !! Good work. Thanks too.
@Rzapata14
@Rzapata14 Год назад
Amazing! thank you for sharing with us.
@yandai6253
@yandai6253 2 года назад
Thanks a lot. It is a gerat introduction for OCT.
@MsHilol92
@MsHilol92 8 лет назад
awesome explanation thank you!!!
@nc956
@nc956 9 месяцев назад
Great video - thanks !
@SidneyCrosbyGOAT
@SidneyCrosbyGOAT 9 лет назад
Great stuff!!!
@nadarasarbahavan6269
@nadarasarbahavan6269 5 лет назад
Brilliant! Subscribed.
@anthonyphan4036
@anthonyphan4036 7 лет назад
Great Video! Could you make one on Swept Source OCT?
@kazzie1998
@kazzie1998 7 лет назад
Great video! I really understand TD-OCT now, but could you explain how FD-OCT works? i can't really grasp how that would be implemented in this system. Do you detect all photons with different frequencies? How would different path lengths affect these numbers? I hope you read this!
@nathanclin70
@nathanclin70 7 лет назад
Great explanation. Could you talk about the Spectral Domain OCT?
@gsonwu475
@gsonwu475 2 года назад
Nice video! You explain the principales of OCT much better than my teachers hhh
@majdhaddad6184
@majdhaddad6184 3 года назад
Thank you very muck this really did help me a lot❤
@nertev8731
@nertev8731 Год назад
Thank you,it's a great video
@sevadahakobyan504
@sevadahakobyan504 7 лет назад
Thanks for sharing.
@HarishSasikumar
@HarishSasikumar 8 лет назад
Great tutorial :)
@alighazi6352
@alighazi6352 6 лет назад
great lecture
@lambda4931
@lambda4931 4 месяца назад
Thank you!
@nesrineogab5885
@nesrineogab5885 2 года назад
amazing!! god bless you
@seshachary5580
@seshachary5580 2 года назад
very educative. thank you regards
@seshachary5580
@seshachary5580 5 лет назад
Thank you regards
@RoentgenChernobyl
@RoentgenChernobyl 2 года назад
Thank you.
@gokhangokdogan
@gokhangokdogan 6 лет назад
When we send red and orange light together, will the beamsplitter split the red light to object (or mirror) and the orange light to mirror (or object) ?
@gokhangokdogan
@gokhangokdogan 6 лет назад
If we mention the 4th case for L1 and L2 distances, L1 is not equal L2, but the difference between them is not lamda/2. What happens?
@ZainabFakhraMD
@ZainabFakhraMD 8 месяцев назад
does the L1 in the explanation correlate to depth and L2 width?
@rokeyamumtahanamou6188
@rokeyamumtahanamou6188 4 года назад
how do we adjust the mirror for the next layer?in this video for example the green layer.I understood for L1=L2 we see blue but how do we see for green layer? Thnaks in advance
@sheetalsharma1996
@sheetalsharma1996 6 лет назад
Very informative
@CyberHo4X
@CyberHo4X 14 дней назад
Unfortunately the fourier part and building layer for layer is missing.
@maxkotlarchyk4242
@maxkotlarchyk4242 8 лет назад
Hi Zach. Decent very beginner video but I think it may be misleading to most because you are talking about versions of OCT which are no longer used. All current systems work in the spectral domain, require long coherence length, and have no scanning mirror. Most modern ones sweep the laser source to achieve an artificially large bandwidth and fine resolution. The A-scan information is recovered from the fourier transform of the fringes. To me the most difficult thing to grasp is the relation between bandwidth, coherence autocorrelation, and resolution... i.e. why sweeping through multiple wavelengths gives you higher resolution.
@MrObear
@MrObear 5 месяцев назад
Max, do you have a link that explains how the current systems work?
@mounirtighilt6348
@mounirtighilt6348 3 года назад
can u do a video explaining the OCT FD and OCT time domain?
@charliefreundlich7963
@charliefreundlich7963 8 лет назад
I am just learning about this, but I think the speaker misspoke at around 18:30. He said the coherence has to do with the difference between L1 and L2. Actually, the coherence length cares about the magnitudes of L1 and L2. As long as both L1 and L2 are less than the coherence length, you can still make reasonable observations regarding interference when the are varied by some small delta, provided that L2+delta is less than the coherence length as well.
@zachnadler1914
@zachnadler1914 8 лет назад
+Charlie Freundlich Hey Charlie, thanks for the comment. I agree that I wasn't very clear on this point, so hopefully I can help with the confusion. The coherence length actually doesn't specifically deal with the L1 or L2 distances. Coherence in the context of light really deals with the ability of light to interfere. For instance, using a Michelson interferometer in the case of a laser (a perfectly coherent source) we can send half the beam a very large distance (ie L1=10m) and the second part a very short distance (ie L2=3mm) and there will still be interference because the laser uses light of very narrow bandwidth (the delta lamda in the equation at 20:15). However, when we have a light source with a broader bandwidth (with orange light as well as red) the coherence length shortens. In that situation there is only interference when the path length difference between the two legs is smaller than the coherence length. All this said, if L1 and L2 are shorter than the coherence length you are correct, there will be interference. Generally speaking, L1 and L2 are much longer than the coherence length which might only be a couple of microns. Thanks again! Let me know if there is further confusion.
@siddharthrawat7205
@siddharthrawat7205 8 лет назад
also the fringe contrast depends upon the magnitude of intensity values reflected from the two arms, one can adjust it by using OD filters or by putting a glass slide instead of a mirror assuming that you sample is on a glass slide too in the other arm if you don't want to use ODs to complicate the system
@inaugurated
@inaugurated 5 лет назад
@@zachnadler1914 I was also really confused about this and had the same thought that L1 and L2 had to be shorter than the coherence length. But I get it now. Even though L1 and L2 are larger than the coherence length and the individual light beams may not be coherent anymore, the phase shifts between the red and orange waves are still (almost) the same for L1 and L2 as long as the path length difference is within the coherence length. As long as the phase shift between red and orange is the same for the interfering beams, an interference pattern will emerge.
@idoctor-manjotkaur8574
@idoctor-manjotkaur8574 Год назад
V helpful
@rooneymax9144
@rooneymax9144 4 года назад
Very good
@viraj__shah
@viraj__shah 9 лет назад
Great video. I have a couple of follow up questions. 1) I'm not sure I understood why the addition of "extra" frequencies (larger bandwidth light source) solved the picosecond laser/monochromatic issue (i.e. that picosecond lasers are too expensive). Is it just that a pulsed light source that isn't as spatially coherent as a monochromatic laser is much cheaper and that you can get away with a light source that has a reasonable coherent length? 2) Let's say you want to get L1 to equal L2. I imagine you can just calibrate until you see a bright spot. L1 might not be equal to L2 but you know that they are integer half wavelength in difference. Is this correct? Or are you able to move these within
@zachnadler1914
@zachnadler1914 9 лет назад
Viraj Shah Great questions! Not sure I can adequately answer them in a comment but, I will try... 1. I was a little confused on this question. The broader the bandwidth of the light source equals a smaller the coherence length (and by extension finer axial resolution). Interference of light between the two legs of the interferometer only occurs when the path length of light traveled by one leg is within one coherence length of the distance traveled by the other leg. In regards to the femtosecond laser, one of the primary limitations I didn't mention is that the sensitivity of these sources are not great enough for biological tissues and can be 1000x less than the broad bandwidth sources. 2. Because the interference occurs within a coherence length you can bring the optical path lengths of the two legs to within tens of microns of one another just by observing interference and technically even closer than that. My engineering background is limited so I don't have a great answer for you in terms of the mechanism for scanning. Probably somewhat system dependent but galvos, resonant scanners and stepper motors sound good to me. One thing I left out is that the moving reference mirror was used in the original systems (called Time Domain OCT) but newer technology (Spectral Domain OCT) leverages a fourier transform to replace the moving reference mirror. These systems are faster and less susceptible to noise so most common commercial systems use SDOCT. Maybe I'll make a video detailing that technology. Thanks for the questions! Let me know if I can help any further!
@viraj__shah
@viraj__shah 9 лет назад
Zach Nadler This is great and very helpful. Thank you!
@sowmyanandipati5359
@sowmyanandipati5359 4 года назад
Can I have the references for this presentation....which article have you taken ???
@deepakkrishnan2175
@deepakkrishnan2175 7 лет назад
I have a doubt. Is it better to use light with high coherence length?
@bcsushi91
@bcsushi91 7 лет назад
If it is high coherence length you don't get as much "spread" of the light and you won't see as much, but it would increase resolution
@veronicanicholls7132
@veronicanicholls7132 6 лет назад
Should high myopes have one every year
@sendafessi1733
@sendafessi1733 3 месяца назад
i love you
@live4Cha
@live4Cha 5 лет назад
Come on!!! Its not mikelson interferometer its michael + son its michelson intrf...
@mandolinic
@mandolinic 5 лет назад
Painfully slow presentation. I recommend watching at 1.75x normal speed.
@joachimvogel3367
@joachimvogel3367 4 года назад
Thanks for the tip!
@inventaunmanana4860
@inventaunmanana4860 5 лет назад
i love you
Далее
2021 OCT  in Glaucoma (1) : OCT physics
16:06
Просмотров 18 тыс.
pitfalls when reading OCT glaucoma report
20:38
Просмотров 27 тыс.
Fundoscopy Quiz
3:40
Просмотров 83 тыс.
WHAT IS OCT || OCT technology explained ||
31:32
Просмотров 61 тыс.
ONH and RNFL Imaging by Dr. Hannah de Guzman
39:22
Просмотров 56 тыс.
Intro to Clinical Imaging
17:23
Просмотров 79 тыс.
Fundus images explained by an ophthalmologist
13:55
Просмотров 334 тыс.
Ordering and Interpreting Retinal OCT Images
56:58
Просмотров 3,4 тыс.