Тёмный

OverVoltage Fault In VFD Solution| Overvoltage Error Troubleshooting in VFD| OV| OU| OV1| OV2| OV3| 

Nice Electronics
Подписаться 21 тыс.
Просмотров 53 тыс.
50% 1

OverVoltage Fault In VFD Solution. Overvoltage Error Troubleshooting in Variable frequency Drive. OV, OU, OV1, OV2, OV3 Fault Solution
Is video me VFD Over voltage Fault jo hamari VFD me ata he vo kyo ata he and Hum VFD ke Overvoltage Fault ko kese solve kare Vo Hindi language me Bataya he. Ki Drives me OV3, OV2, OV1,OV, Ya OU Fault Code se bhi Over voltage Error ko indicate karti he.
Problem Solved
Variable Frequency Drive (VFD) OverVoltage Fault Solution or Troubleshooting
If you Have any Problem in this Video please Comment Below.
Thanx For Watching.
Please Like, Share and Subscribe to My channel.
Mail ID: niceelectronics8831@gmail.com
#Ov3 #Overvoltage #Ov3Error #Vfd #Ov1 #Ov2 #Ov3Fault #Ov3solution #OvError #E.OV2 #E.OV3

Наука

Опубликовано:

 

7 авг 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 94   
@mithileshkumarpal4421
@mithileshkumarpal4421 2 года назад
Very nice and very helpful vedio sir
@saifiquadir739
@saifiquadir739 8 месяцев назад
Excellent explanation bro ...
@learnbyshiva725
@learnbyshiva725 3 года назад
Thanks sir
@arvindvitekar2454
@arvindvitekar2454 9 месяцев назад
Very nice explain and Very informative videos keep it up
@hkgargeducation3460
@hkgargeducation3460 4 года назад
Great
@sureshnikuse3339
@sureshnikuse3339 Год назад
Thanks
@girishmirani7180
@girishmirani7180 Год назад
Nice information
@KULWANTSINGH-eb3pd
@KULWANTSINGH-eb3pd 2 года назад
Mere paas mitsubishi D700 inverter he usme breaking resitence ke conection kis point par honge sir please help
@browinkumar1123
@browinkumar1123 Год назад
Sir mere pass l&t cx2000 vfd h vo oct ka foult dikha rhi h Agr motor ke wair nikal dete h to nahi dikati fir motor chang Kiya fir se vhi foult dikha rhi h
@prabhatsingh5377
@prabhatsingh5377 Год назад
Please make vfd speed control method .
@abhishektiv4400
@abhishektiv4400 3 года назад
Super
@KarigorEngineeringTechnology
@KarigorEngineeringTechnology 2 года назад
VFD তে কেন Overvoltage fault আসে এবং তার কি সমাধান তা জানতে হলে নিচের ভিডিওটি দেখতে পারেন ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-rpM16r8PLjk.html
@rahulkharva553
@rahulkharva553 Год назад
Sir different control method ke bare mai baataye
@shivkumar-ez6om
@shivkumar-ez6om 6 месяцев назад
Ms300 vfd,.. OVN error occurred .. please share solutions
@jkbox299
@jkbox299 2 года назад
Sir,75/55kw drive pe 49.1 kw motor run kar rha hai or uspe 10kw 8ohm ka DBR lga hai with DBU UNIT 32AMP . TO DBR me over heating ka problem aa rha hai ,to iska problem kaise find kare.
@nikhilgohel4051
@nikhilgohel4051 4 года назад
Please make video on OL2 Over load drive vedio
@niceelectronics9505
@niceelectronics9505 4 года назад
Thanx Nikhil Gohel for your Comment.. I will try to make a video Overload in upcoming few days ..Thanx
@piyushyadav-wi2hw
@piyushyadav-wi2hw 3 года назад
Sir hmare yha 5.5kw ki motor lgi hai take up winch k liye sir conveyor belt k liye.... sir bhut bar trip hota hai Over voltage pe ye issue slove nhi ho pa rha..... breaking resistor bhi lga jiska resistance 298 ohm measure kiya hai..... ky issue ho skta hai sr plz help....
@niceelectronics9505
@niceelectronics9505 3 года назад
Please follow the procedure indicate in video..
@AmitKumar-pi2cu
@AmitKumar-pi2cu 4 года назад
Sir photoelectric senser pr b videos bnao
@niceelectronics9505
@niceelectronics9505 4 года назад
Thanx Amit Kumar For your Comment . I will make a video on Photoelectric sensor in upcoming days..Thanx
@shoaibalam4557
@shoaibalam4557 8 месяцев назад
Nice #shoaibelectronicstech
@kinderoye
@kinderoye 3 года назад
E.0u2 error in mitsubishi vfd motor stop after 1 min pls help
@sugathpriyantha1058
@sugathpriyantha1058 3 года назад
hello plz help me i have ip5A vaccume machine system.its display showing 12 over voltage then stop machine
@hemantjadhav8451
@hemantjadhav8451 2 года назад
Ou2 error aa raha sir din me three ya four time aata he sir kuch solution bataye sir
@pratikrana2466
@pratikrana2466 4 года назад
What is function of that diode across the braking resistor terminal?
@niceelectronics9505
@niceelectronics9505 4 года назад
it provide closed path for current flowing through the resistor after the breaking IGBT turns off because resistor also have some inductance. So It is used to protect the breaking igbt from high current after it turns off.
@mohitkumarmohitkumar4119
@mohitkumarmohitkumar4119 Год назад
Sir sinconijing ka video bnao kaise karte h
@khalipili2200
@khalipili2200 4 года назад
Sir pid pr video kab ayegi aur external fault use kyu karate hai aur kaise karte hai
@niceelectronics9505
@niceelectronics9505 4 года назад
Thanx for your comment. Lockdown ki vagah se practical video nahi ban payegi so me theoretically video bana dunga. Thanx
@girishsasankar1143
@girishsasankar1143 3 года назад
How to set programs. Please make a video
@niceelectronics9505
@niceelectronics9505 3 года назад
Fuji Frenic Drive Programming and Control Terminal Wiring| HINDI| Fuji drive parameter setting| ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-qQVJ0LNqQls.html Fuji Frenic Drive Multispeed Programming and Control Terminal Wiring| Fuji VFD Parameter Setting| ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-1jHWEthhSCk.html
@MizanurRahman-od9sm
@MizanurRahman-od9sm Год назад
Frenic mega 22kw alarm ECF
@bismillahelectronicsindust9824
@bismillahelectronicsindust9824 4 года назад
Sir fuji my program ha k run ke cammand dy or kuch time ke bad run cammand off ho jyae stop time and start time program batae thanks
@niceelectronics9505
@niceelectronics9505 4 года назад
Thanx Haroon Saifi for your comment. Sorry there is no programming available for this type of function. But you can use sleep function in vfd if you want to stop your motor below desired speed. Then start above the desired speed. Thanx
@mithileshkumarpal4421
@mithileshkumarpal4421 2 года назад
Vfd me kaun sa paramete me DBR ka watt and resistance dalte h
@mithileshkumarpal4421
@mithileshkumarpal4421 2 года назад
Please sir ispr vedio banaye ya ese bataye
@sureshnikuse3339
@sureshnikuse3339 Год назад
Please send torque mode parameters in MM440
@madhumahanta4307
@madhumahanta4307 3 года назад
Mere VFD ki Sath rj45 cable ke sath Ek RMS attige hai main sim lagakar kaise use access Karen kaun sa application download Karen
@bhaveshparmar7682
@bhaveshparmar7682 3 года назад
sir somax drive error E40 MOTOR OVERLOAD aa raha hai pls give solution. drive output -3ph AC 0-480V 45A 22KW hai
@MyShukan
@MyShukan 3 года назад
Sir, Can you help on how to fix under voltage error. We are fuji drive in which we are frequently facing this error.
@niceelectronics9505
@niceelectronics9505 3 года назад
Under voltage may due to low input voltage. So please Check input supply connection and input mcb..
@AmanGupta-im6dj
@AmanGupta-im6dj 2 года назад
Lu fault in drive... How to solve..... There is no input phase loss
@raisesahb7978
@raisesahb7978 6 месяцев назад
Ou1 fult ka hal btaen please ya phir apna what's app den qk maine is foult ka video bnaya hua hai
@winthanttun5814
@winthanttun5814 Год назад
Please in English, it will be helpful for non-hindi speakers
@probhathandique314
@probhathandique314 3 года назад
Can anyone help me about VTDE drive menual
@ashwanidubey8102
@ashwanidubey8102 2 года назад
sir how to reset 0u1 fault in Fuji ac drive
@rajkumarnishad9748
@rajkumarnishad9748 3 года назад
सर जी आप मुझे यह बताइए यासकावा ही उठाओ जन में कल और भी का प्रॉब्लम आ रहा था वह भी ओवर वोल्टेज जैसे मशीन स्पीड होती थी तो ऐसे हो पर स्पीड आता था वह भर वोल्टेज किस कारण से यह निकल पाएगा क्या करें इसके लिए
@SHAHZADHUSSIAN58
@SHAHZADHUSSIAN58 3 года назад
Omran 3g3jz ov fault and inverter stop the moter 20mint after reset and run then start moter 1 HP 3 phase moter ampire 15 to 20 I want decrease ampire
@Technow3157
@Technow3157 4 года назад
Make your voice clear recording,,,
@RehanAnsari-sy5ro
@RehanAnsari-sy5ro 2 года назад
Meri vfd ki problem hai ke error too over voltas ki aa rahi hai lekin motor chalte chalte aati hai motor chal Rahi hai 4 se 5 minute chalti hai aur over voltas ki error aa jati hai aur motor band
@khalipili2200
@khalipili2200 4 года назад
Sir DBR vfd lagane ke liye vfd kon sa programming karni paregi
@niceelectronics9505
@niceelectronics9505 4 года назад
Thanx for your comment.. 1) Over Voltage Stall Prevention = Disable 2) Auto Voltage Regulation = Off Thanx
@khalipili2200
@khalipili2200 4 года назад
@@niceelectronics9505 Sir is pr short video bana de please
@satishpawar110
@satishpawar110 4 года назад
Sir contact number dena
@niceelectronics9505
@niceelectronics9505 4 года назад
09904670809
@mukeshbhol
@mukeshbhol 3 года назад
Reactor ka capacity kaise decide karte hai.
@niceelectronics9505
@niceelectronics9505 3 года назад
Input choke ki bat kar rahe ho kya..?
@ashishmeshram244
@ashishmeshram244 Год назад
Bhai ol1 ka error kaisa solve kare....
@nikleshbaghel4373
@nikleshbaghel4373 3 года назад
Sir error 08 ki solutions btaiye
@niceelectronics9505
@niceelectronics9505 3 года назад
Konsi vfd he and model konsa he...
@mohammadpathan4668
@mohammadpathan4668 4 года назад
DC BUS Voltage should be Input voltage X √2
@niceelectronics9505
@niceelectronics9505 4 года назад
Yes Mohammad Pathan you are right..
@SuNnyend
@SuNnyend 3 года назад
Dc bus voltage ka solution bataye sir
@AmanGupta-im6dj
@AmanGupta-im6dj 2 года назад
Lu fault aane pe kya kare
@SuNnyend
@SuNnyend 3 года назад
Hello sir. Mujhe bhi omran ki drive main ye problem aa rahi hai is motor se conveyer chalti hai or uske uper glass jab glass doosri machine par jaane lagta hai toh ye error aa jaata hai. Ye error sirf bade glass ki sheet se aata hai Chote sheet nikal jaate hai. Basically ye error hamari loader machine main aa raha hai. So mujhe kya krna chahiye Kya apka number mil sakta hai
@niceelectronics9505
@niceelectronics9505 3 года назад
Vfd me konsi error a rahi he.
@niceelectronics9505
@niceelectronics9505 3 года назад
Vfd me error kya a rahi he.. ?
@SuNnyend
@SuNnyend 3 года назад
@@niceelectronics9505 ou ka error
@jemmyprakosa2867
@jemmyprakosa2867 4 года назад
How to repair OC3
@niceelectronics9505
@niceelectronics9505 4 года назад
Please watch this video this video might be help to solve Oc3 error ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-ezGe-f7JRpQ.html
@ishtiaqahmad4886
@ishtiaqahmad4886 2 года назад
Tel about Ou3 fault
@shaiksadiq128
@shaiksadiq128 3 года назад
Bro VFD earthing problem stop in between what is the solution
@niceelectronics9505
@niceelectronics9505 3 года назад
Matlab kya apki vfd koi fault de rahi he ?
@shaiksadiq128
@shaiksadiq128 3 года назад
@@niceelectronics9505 ha bhai earth 16 fault
@niceelectronics9505
@niceelectronics9505 3 года назад
Apki vfd ka model konsa he..
@shaiksadiq128
@shaiksadiq128 3 года назад
@@niceelectronics9505 ACH 550..ABB
@niceelectronics9505
@niceelectronics9505 3 года назад
Motor ka cable vfd me se Nikal kar vfd ko run Karo and output measure karo..error continue raheti he to vfd ka fault he or agar error Nahi ati he to cable or motor ka fault ho Sakta he..
@kumarsaurabh3936
@kumarsaurabh3936 Год назад
Address ?
@t20anil
@t20anil 2 года назад
Over load problem in drive without load
@sabithkk6883
@sabithkk6883 2 года назад
Jog mode...OU3 error Coming.. what is problem
@ishtiaqahmad4886
@ishtiaqahmad4886 2 года назад
Please tel about fault ou3
@KarigorEngineeringTechnology
@KarigorEngineeringTechnology 2 года назад
VFD তে কেন Overvoltage fault আসে এবং তার কি সমাধান তা জানতে হলে নিচের ভিডিওটি দেখতে পারেন ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-rpM16r8PLjk.html
@RohitkumarRohitkumar-bk3wo
@RohitkumarRohitkumar-bk3wo 3 года назад
Ou1 lokta hai sir
@sarsabzsolarpowersystem6487
@sarsabzsolarpowersystem6487 3 года назад
Ou1 ou2 ou3 fault arha hy g 18 /22 kw vfd
@SuNnyend
@SuNnyend 3 года назад
Same in our vfd
@sabithkk6883
@sabithkk6883 2 года назад
OU3 error Coming ??
@dineshark7537
@dineshark7537 2 года назад
Sir opl problem aa RHA h
@monubatham6246
@monubatham6246 4 года назад
Sir number do
@niceelectronics9505
@niceelectronics9505 4 года назад
Please try to mention your problem in comment..
@ahmadshezad123
@ahmadshezad123 6 месяцев назад
آپ کی آ واز کلئیر نہیں ہے ،میوزک کی ذیادہ ہے
Далее
#kikakim
00:23
Просмотров 9 млн
invt vfd fault output voltage problem CPU
9:09
Просмотров 9 тыс.
Why inductor choke used in Variable frequency Drive?
8:11