Parr 6400 Calorimeter Installation Guide 

Parr Instrument Company
Подписаться 561
Просмотров 18 тыс.
50% 1

A video supplement to aid users with the installation of Parr Instrument Company's 6400 Automatic Isoperibol Calorimeter.
Call (800) 872-7720 for information or visit our website: www.parrinst.com
Parr Instrument Company prides itself on top notch quality standards and meeting the needs of its customers in the scientific community.

Опубликовано:

 

25 авг 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 8   
@elghonemyeg3003
@elghonemyeg3003 3 года назад
hi sorry for requesting, but it will be very helpful if there an video about calibration, for parr 6400
@ParrInstrumentCompany
@ParrInstrumentCompany 3 года назад
Thank you for the feedback. We will look into getting that added.
@rajeshvaghela5743
@rajeshvaghela5743 4 года назад
Hello, I need a Video of the 6200 Bomb Calorimeter Unbox & Installation.
@ParrInstrumentCompany
@ParrInstrumentCompany 4 года назад
Hello Rajesh, We currently do not have an installation video for our 6200. The best source for installation is our 6200 Operating Instructions that may be downloaded from our Instruction Manuals page at www.parrinst.com/support/downloads/manuals/. We would be happy to provide further assistance as needed, please contact us at www.parrinst.com/contact/parr-usa/.
@kevins8753
@kevins8753 3 года назад
What is function of vent line?
@ParrInstrumentCompany
@ParrInstrumentCompany 3 года назад
Hello! Thank you for your question. The vent line is used to depressurize the oxygen fill line inside the instrument. After the oxygen filling is complete the oxygen fill solenoid is de-energized and the tubing vents out the vent line. When this happens the pressurized gas inside the vessel causes a check valve to seal the chamber.
@barbarabrkovich1988
@barbarabrkovich1988 Год назад
Why is it so loud
@ParrInstrumentCompany
@ParrInstrumentCompany Год назад
Hello Barbara, Thank you for your comment. There are many components of the 6400 that can cause noise in the system. Depending on the age of the instrument, this can either be a sign of a component that needs to be replaced or normal operation. The exhaust of the pressure from the inside of the combustion vessel can be somewhat surprising at first. 450psi of oxygen is being release from a 3/8” diameter tube into a smaller collection vessel. The vessel is also rinsed/washed a few times to ensure that everything is clean. This uses the same 450psi of oxygen pressure. If this is an issue, the tubing from the exhaust and vent connections for the back of the calorimeter can be plumbed to a larger container or to a space outside of the lab. If you need any additional information please feel free to call us at (309)-762-7716 or or send an email to parr@parrinst.com and one of our Calorimeter Technical Representatives can assist.
Далее
Я ДОСТРОИЛ ЗАВОД - Satisfactory
19:13
Просмотров 167 тыс.
Bomb Calorimetry
5:46
Просмотров 87 тыс.
Bomb calorimetry: making the bomb w/ liquid 1-octanol
14:27
Bomb Calorimeter Parr 6200 calibration
11:56
Video Manual of IKA C-200 Operation
15:28
Просмотров 15 тыс.
Bomb Calorimeter (Updated)
11:02
Просмотров 5 тыс.
Calorimetry
4:54
Просмотров 344 тыс.
Lockheed's Insane Attack Carrier: The CL-1201
14:21
Просмотров 1,4 млн