Тёмный

PDA Test ( Dynamic Load Testing ) 

Aung Naing
Подписаться 4,6 тыс.
Просмотров 332 тыс.
50% 1

The PILE DRIVING ANALYZER system (PDA)
The driving hammer itself is used to perform High Strain Dynamic Tests
Hummer & Drive system performance

Опубликовано:

 

7 май 2013

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 43   
@user-ig9qr2mi6e
@user-ig9qr2mi6e 10 лет назад
The free fall hammer is no centralizer and cushion, it may cause the dis alignment of the drop.
@user-dw6yi6hf7r
@user-dw6yi6hf7r 10 лет назад
Dyanamic load test on pile with 600 mm dia and 15.10 m depth from cut off level with 40 ton design load and 60 ton of test load which done at Mundra (Kutch) site...
@AungNaing
@AungNaing 8 лет назад
Noted with thanks
@TEMELTASCONSTRUCTION
@TEMELTASCONSTRUCTION 3 года назад
Good work
@cartyrashiee
@cartyrashiee 10 лет назад
Still have all the pictures n the method statement for this method? Can u share n contact me...
@shishirmishra5745
@shishirmishra5745 6 лет назад
can anyone tell me the procedure of Dynamic load test or any link where its given briefly. Thanks in advance!
@Aravmauryavlogs
@Aravmauryavlogs 4 года назад
This video is more useful for Briefing of Dynamic Load Testing of Piles:- ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-HS65W6d08bM.html
@monishfj
@monishfj 7 лет назад
CSX value should be monitored during PDA testing. It should not exceed 90% of the yield strength or else there will be pile damage...
@lamszeyue
@lamszeyue Год назад
No Health and safety measures for the measurement of hammer heights?? Where is this place?
@sterlingfrancis4487
@sterlingfrancis4487 10 лет назад
going to do some of this today, thanks for this vid. any technical comments about this is much appreciated... long live engineers!!!! f#ck architects.... lol
@tuffah5698
@tuffah5698 6 лет назад
Wow pile test load very heavy :D
@abdalwahedcivileng4594
@abdalwahedcivileng4594 6 лет назад
رائع جدا
@bambamroy5163
@bambamroy5163 5 лет назад
Have you a job for me in Deep foundation testing department
@ordinarylifeasia
@ordinarylifeasia 8 лет назад
could have improve the safety of worksite
@oleksandrbogdanov5229
@oleksandrbogdanov5229 5 лет назад
have that guys ever heard a word SAFETY?
@afrozalam5039
@afrozalam5039 6 лет назад
how many times hammering sir for checking the pile
@PraveenKumar-gu5eg
@PraveenKumar-gu5eg 3 года назад
2
@djambronxz666
@djambronxz666 7 лет назад
I think the crane operator doing the best job...can handle the heavy hammer...and the most important thing are gauges not broken...haha
@ravibabud1989
@ravibabud1989 7 лет назад
where is Freepal... accutually Hammer Fall down is nt good.... so testing time pile taken Load 50% only....
@azahar9042
@azahar9042 4 года назад
Wow so many safety lapses somemors can smoke onsite WTH!
@scchaudhary8329
@scchaudhary8329 5 лет назад
hammer weight& hammer height how decied
@ganeshb3187
@ganeshb3187 3 года назад
One to two percentage of ultimate load
@kustiawantjong9586
@kustiawantjong9586 3 года назад
What is the diameter of the pile?
@AungNaing
@AungNaing 3 года назад
1300mm dia
@edws261
@edws261 7 лет назад
PDA test is recommended for pile bearing capacity below ( 100 ton .....Static loading test . PDA test is faster and competitive.
@VALV3RD3
@VALV3RD3 5 лет назад
You´re completely wrong
@sakeelraza1779
@sakeelraza1779 5 лет назад
Shakeel Payal contactor Bareilly 98 37 15 15 36 97 19 15 15 36
@Dudububu57
@Dudububu57 9 лет назад
gonna do this today, long live Safety supervisors!! F#ck Engineers.. lol
@parie89
@parie89 9 лет назад
untuk pengetesan PDA,PIT,LOADING TEST dan sondir silahkan hubungi di 085274736467 (ARLAND), HARGA BISA DI NEGO. kami melayani dimanapun anda berada.
@HongriWang
@HongriWang 2 месяца назад
If there is no support system, there is no need to dig such a big hole.
@khientran1741
@khientran1741 4 года назад
Sao o vn thư tai toan dung mup đơn thui may ma
Далее
PDA Test ( Dynamic Load Testing )
8:17
Просмотров 84 тыс.
BASEMENT EXCAVATION - BORED PILE
16:06
Просмотров 2,4 млн
I Built a EXTREME School Bus!
21:37
Просмотров 6 млн
Static Load Testing Animation
2:59
Просмотров 3,9 тыс.
Pile Dynamic Load Test
10:08
Просмотров 38 тыс.
How to Perform Pile Integrity Testing?
12:55
Просмотров 100 тыс.
Types of Pile Testing
4:28
Просмотров 64 тыс.
Bauer BG System - Kelly System
6:34
Просмотров 2,3 млн
Pile Driving
14:15
Просмотров 40 тыс.
Bored Pile
4:56
Просмотров 299 тыс.
Pile Load Capacity Testing
4:25
Просмотров 80 тыс.