Тёмный

Photovoltaic Self-Consumption: How to Avoid Power Factor Penalties | Schneider Electric 

Schneider Electric
Подписаться 211 тыс.
Просмотров 26 тыс.
50% 1

Discover the impact of photovoltaic (solar) production used for self-consumption on the overall power factor of your building's electrical installation. Learn how to compensate for this negative impact by directly acting on the photovoltaic inverters. Our expert shares cutting-edge knowledge and practical tips to help you avoid power factor penalties and optimize your electrical installation design. Perfect for anyone involved in solar self-consumption, photovoltaic energy management, and sustainable building practices.
🔔 Timestamps:
0:01 - Introduction
0:32 - Understanding Power Factor
1:15 - Impact of Photovoltaic Systems on Power Factor
1:55 - Solutions to Compensate Power Factor Degradation
3:02 - Practical Example and Conclusion
🔗 View full playlist: • Photovoltaic Self-Cons...
🔗 Find more in the Electrical Installation Wiki: www.electrical-...
🔗Download the Electrical Installation Guide (PDF) for off-line reference: www.schneider-...
---------------------------------------------------------------------------------------------------------------------------------------------------------
🎯 DISCOVER JOB OPPORTUNITIES
---------------------------------------------------------------------------------------------------------------------------------------------------------
➡️ Job Opportunities: spr.ly/6002e51fp
---------------------------------------------------------------------------------------------------------------------------------------------------------
👋 GET TO KNOW US BETTER
---------------------------------------------------------------------------------------------------------------------------------------------------------
➡️ Global Website: spr.ly/6007e5GEv
➡️ Discover our Services: spr.ly/6009e5GOJ
➡️ Visit our Blog: spr.ly/6001e5GkB
➡️ Click here to subscribe to Schneider Electric: spr.ly/6005e5G9R
---------------------------------------------------------------------------------------------------------------------------------------------------------
⚡ GET IN TOUCH VIA SOCIAL MEDIA
---------------------------------------------------------------------------------------------------------------------------------------------------------
➡️ LinkedIn: spr.ly/6008e5GWy
➡️ Facebook: spr.ly/6001e5Gsz
➡️ X: spr.ly/6000e5GFM
➡️ Instagram: spr.ly/6009e5G7J

Опубликовано:

 

15 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 43   
@facilityhead6516
@facilityhead6516 3 года назад
Thank you so much for the information
@schneiderelectric
@schneiderelectric 3 года назад
Thank you for your feedback!
@ghita0407
@ghita0407 3 года назад
Very well explained, thanks
@salarhadi2988
@salarhadi2988 2 года назад
Please explain more details about power factor and hybrid in double conversion technology inverter…thank you
@manjyotb
@manjyotb 4 года назад
How do I implement this? Ever since I've installed a schneider solar inverter my PF loss is more than the generation gain.
@schneiderelectric
@schneiderelectric 3 года назад
It is difficult to provide an answer for specific cases without knowing the context. For your concrete case - please contact your local Schneider Electric Support Center.
@electricalsolargyan6157
@electricalsolargyan6157 4 года назад
Dear Madam as per your solution there is loss for installation and investor company in solar PV plant . I have one more solution , as we know that we are using APFC Controller for supplying reactive var but due to reason because APFC get sum of solar and grid that's why not able to measured only grid . If we Install CT of APFC panel In main incomer of grid line and then operate Capacitor duty contactor though it then you will be able to supply Var for reactive power demand . in this way you will utilise full solar power for active power . because if we supply reactive power from inverter then there is decreasement in active power of inverter which is finally a loss of inverter power
@akshay3348
@akshay3348 4 года назад
Ranjit your solution is partially correct, what if only solar produced kWh are being utilised by the industry for certain time of day? As your sensing is of Mains, the APFC will remain there as mere statue.
@schneiderelectric
@schneiderelectric 3 года назад
Hello Ranjit! You are right, dedicated PF equipment to correct PF loss is a good alternative solution.
@jakovbilic4556
@jakovbilic4556 2 года назад
I would like to know more about this, do you maybe have some drawings of this kind of systems. Also how would you connect smart-meters and what would you really get from grid if you produce 100% of active power you need?
@itachiiQuang
@itachiiQuang 2 года назад
Can you show to us model of "Control system" ? thank you !!!
@ahmetcabri5348
@ahmetcabri5348 Год назад
That's great!
@niaziexplores
@niaziexplores 3 года назад
Do modern inverters have built in controller or set points to control their power factor?
@schneiderelectric
@schneiderelectric 3 года назад
Hi Niazi, thank you for reaching out! A built-in controller inside each inverter would probably not be the most appropriate solution, as usually one installation contains several photovoltaic inverters. As we see it, it's better to have a control system (transverse to the complete installation) which gets measures from the different photovoltaic inverters, and gets the value of the power factor at site level (at the point of common coupling). Based on this data, this control system determines and communicates the optimal set point to each of the photovoltaic inverters.
@SwapnaliDesai-rx8rl
@SwapnaliDesai-rx8rl Год назад
What can be the other effects of PV system for reduction of Power factor and how can we improve pf within photovoltaic system?
@schneiderelectric
@schneiderelectric Год назад
Thank you for your message, Swapnali Desai. We apologize for any inconvenience caused. For troubleshooting support or to express your concerns, please reach out to a technical expert in your location here: www.se.com/ww/en/work/support/country-selector/contact-us.jsp
@md.mezanurrahman5437
@md.mezanurrahman5437 Год назад
What about power quality and power factor when the excess amount is exported to grid? I mean in Mains revenue meter what will be the PF ( inductive /capacitive) at the time of export?
@schneiderelectric
@schneiderelectric Год назад
Thank you for your message. We house most of our documentation in a virtual database here: www.se.com/ww/en/download/. If this does not address your concerns, please reach out to a technical support person in your location. www.se.com/ww/en/work/support/country-selector/contact-us.jsp
@pednykholer5371
@pednykholer5371 Год назад
i can not understand what you have explained please show more detail how setup export Q-Power from inverter
@schneiderelectric
@schneiderelectric Год назад
Thank you for your message, Pedny. If you would like to request installation support, please contact our technical experts in your location here: www.se.com/ww/en/work/support/country-selector/contact-us.jsp
@风景这边独好-g4k
@风景这边独好-g4k 9 месяцев назад
Can more capacitors be added to increase pf?
@schneiderelectric
@schneiderelectric 9 месяцев назад
Thank you for your message. We house most of our documentation in a virtual database here: www.se.com/ww/en/download/. If this does not address your concerns, please reach out to a technical support person in your location.www.se.com/ww/en/work/support/country-selector/contact-us.jsp
@kriptondanyegenimgelecek3346
@kriptondanyegenimgelecek3346 25 дней назад
Is there and PCB controller with an AI?
@schneiderelectric
@schneiderelectric 25 дней назад
Thank you for your message. We house most of our documentation in a virtual database here: www.se.com/ww/en/download/. If this does not address your concerns, please reach out to a technical support person in your location.www.se.com/ww/en/work/support/country-selector/contact-us.jsp
@engr.sohailtariq6261
@engr.sohailtariq6261 3 года назад
@Schneider Electric what is response time to set kVAR value on a fluctuating load.
@schneiderelectric
@schneiderelectric 3 года назад
Thank you for your message. We offer a complete set of digital tools to help you find answers to your questions. If you're experiencing difficulty navigating our tools, we offer live chat support to get expert help now. Please select your location here to get started: spr.ly/6050yoiSI
@engr.sohailtariq6261
@engr.sohailtariq6261 3 года назад
Kindly confirm that will capacitor bank panel also work along this control system? because it will be better to get more KVAR from capacitor bank either from the inverter.
@deepalps
@deepalps 2 года назад
did u get some solution, I am facing the same problem.........where to place the CT with integrated systems of PV solar and utility. our system consumes 300KVA and solar panels provide only 200KW , the pf goes down specially when our utility is not consuming power
@schneiderelectric
@schneiderelectric 2 года назад
Thank you for your message. We apologize for any inconvenience caused. Our customer care team would be happy to provide assistance. Please reach out to a customer care member in your location here: www.se.com/ww/en/work/support/country-selector/contact-us.jsp
@Ahiraan-gw7iy
@Ahiraan-gw7iy 2 года назад
I have solutions for you
@deepalps
@deepalps 2 года назад
@@Ahiraan-gw7iy PLS LET ME KNOW
@walterogada8525
@walterogada8525 Год назад
Please share your solution. I'm facing same challenge.
@engr.sohailtariq6261
@engr.sohailtariq6261 3 года назад
Kindly confirm that will capacitor bank panel also work along this control system? because it will be better to get more KVAR from capacitor bank either from the inverter. Like if we have 150 KVAR Load along with 10KVAR fluctuating KVAR. We set the setting like 120 kVAR should be adjusted by capacitor bank panel and remaining divide it on inverter and grid line w.r.t real load.
@schneiderelectric
@schneiderelectric 3 года назад
Thanks for your question, Sohail. - Our expert is on leave and will answer back as soon as possible, when back to the office. If your question is urgent, you may try to contact your local Schneider Electric support: www.se.com/ww/en/work/support/country-selector/contact-us.jsp
@schneiderelectric
@schneiderelectric 3 года назад
Hi Sohail, thank you very much for your patience! - The solution we describe in the video is suitable only to compensate the power factor impact of the PV system. When it is necessary to compensate the reactive power of the loads, capacitor banks are the suitable solution. And if the reactive consumption of the loads is highly fluctuating as you describe, automatic or dynamic compensation will be recommended. For more information: download.schneider-electric.com/files?p_enDocType=Catalog&p_File_Name=PFCED310004EN_%28web%29.pdf&p_Doc_Ref=PFCED310004EN
@engr.sohailtariq6261
@engr.sohailtariq6261 3 года назад
@@schneiderelectric welcome ☺️ and thanks to explain
@Ahiraan-gw7iy
@Ahiraan-gw7iy 2 года назад
If increase reactive power of solar inverter can't it reduce active power as well
@schneiderelectric
@schneiderelectric 2 года назад
Thank you for your message. We apologize for any inconvenience caused. For technical support or to find answers to your questions, please refer to our support center: www.se.com/ww/en/work/support/support-center.jsp or reach out to a technical expert in your location here: www.se.com/ww/en/work/support/country-selector/contact-us.jsp
@pednykholer5371
@pednykholer5371 Год назад
@@schneiderelectric robot answer
@AhmedHassan-ni1nu
@AhmedHassan-ni1nu Год назад
Gorgeous face and explain
@Gallardo6669
@Gallardo6669 25 дней назад
It doesn't click in my head: i understand reactive power is undesired. Therefore its always better if we reduce the reactive power within the whole grid, not only at the measured interconnection. Therefore injecting pure active solar power into the grid should benefit the overall ratio and reduce the percentage of reactive power within the grid. Pls Internet respond...😂
@schneiderelectric
@schneiderelectric 25 дней назад
Thank you for your message. We house most of our documentation in a virtual database here: www.se.com/ww/en/download/. If this does not address your concerns, please reach out to a technical support person in your location.www.se.com/ww/en/work/support/country-selector/contact-us.jsp
@shanmugam5813
@shanmugam5813 3 года назад
Bro tamil please
Далее
Mini bag sealer
00:58
Просмотров 3,4 млн
How 3 Phase Power works: why 3 phases?
14:41
Просмотров 931 тыс.
How to Choose SOLAR Wisely and Avoid Costly Mistakes
25:40
Where does the Reactive Power go? TheElectricalGuy
11:09