@YanasaTV
@YanasaTV 9 месяцев назад
BLACK FRIDAY SALE ON ECOFLOW DELTA PRO Click on the link below and use my code 05YANASA to get extra 5% off on top of all sales until November 30th 2023. EcoFlow Website: us.ecoflow.com/collections/delta-series?aff=653
@Gigi61866
@Gigi61866 Год назад
So glad I came across this. Exactly what I’ve been wanting to do. Well, what I want my husband to do.😂
@jamesborton9237
@jamesborton9237 11 месяцев назад
@Gigi61866 , Go for it, even if you don't install it all , at least run the wire, leaving slack at both ends . Get your inlet box ordered and ON SITE. study your breaker box and get the correct 30 or 50 amp breaker for your box. What size in your generator? Write your information in notepad before you go shopping. Take pictures, take with.
@netpasya
@netpasya 7 месяцев назад
Wait a minute. You're not gonna help?
@gregorycarraway4098
@gregorycarraway4098 2 месяца назад
Ha!! Well, as long as it gets done!!
@rightbro
@rightbro 29 дней назад
Dude , who cares how your paint or what ever looks like. You are making a video to help us out. Don’t worry about what other people think. Thanks for the advice
@dhillman7522
@dhillman7522 8 месяцев назад
For a non electrician nice work! Don't see much to criticize I was impressed you knew the difference between a sub panel and a main in reference to the ground and neutral.
@Psalm2710_
@Psalm2710_ Год назад
I was just talking about this to my husband bc we had no power for 3 days, but we were able to connect our fridge and freezers to our generator. We were one of only 2 neighbors that we know of who didn't lose all our cold food. I even offered up my half empty deep freezer space to some neighbors but they assumed the electric was coming on soon and so no one took up my offer. By day 3, they had to start throwing stuff away sadly! This 1 power outage made my generator pay for itself!
@Gmanspecial
@Gmanspecial Год назад
In my opinion (you probably figured this out first time you used it) your inlet box is mounted too close to your service panel door. When you plug your generator cable in your inlet box you won't be able to access your breakers in your panel without disconnecting your generator cable first from the inlet box. Other than that, it's a nice job.
@KTSLAY
@KTSLAY Год назад
I just did this for a family member. nearly identical set up. Works great. Just have to get a natural gas kit for the Honda Jenny and won't have to worry about fuel...most times.
@carolmartin6719
@carolmartin6719 Год назад
Thanks for sharing this video. My father in law is an electrician.
@MrRebar15
@MrRebar15 Год назад
*Yanasa TV* Bravo well done, thank-you sir for taking the time to bring us along. GOD Bless.
@armyfazer1410
@armyfazer1410 Месяц назад
That Romex is for interior use only. THHN or UF-B would be the better choice.
@netpasya
@netpasya 7 месяцев назад
I'm comfortable with doing electrical things in the house (switches, replacing outlets, installing new outlets, fans, chandeliers, fixtures, etc...) I stay away from the panel. I bought my electrician buddy 2 cases of beer to put one in. He put a 50 amp inlet box with 6/3 cable. I cooked some good steaks on the grill while he was working.
@bootsy7
@bootsy7 9 дней назад
Your very fortunate because over here in Australia these electricians are crooks
@markparker2873
@markparker2873 Месяц назад
Great video and this is how it should be done, congrats!
@pebips
@pebips Месяц назад
Thanks my friend
@barnrazedbyjesse6893
@barnrazedbyjesse6893 Год назад
We DIYed ours too. We use a welder as a generator so we ran it out towards the driveway so we could just pull the utility truck up to it.
@aladrasullivan9018
@aladrasullivan9018 7 месяцев назад
Make sure you use 10-3 wire for this! Also use a meter to make sure that panel is dead,don't just depend on a breaker shutoff!
@gregorycarraway4098
@gregorycarraway4098 2 месяца назад
Great safety point!!!
@chasorchard1140
@chasorchard1140 Год назад
Good job brother... you'll be glad you did that.
@robertworden9810
@robertworden9810 6 месяцев назад
I thought NM cable was not allowed in outdoor conduit since it is considered a “wet” location.
@tightropehikes
@tightropehikes Месяц назад
It’s in sealed conduit.
@Creator_Nater
@Creator_Nater Год назад
Thanks for sharing this!
@ladyryan902
@ladyryan902 Год назад
Had to watch 2x n read comments to c if ur right lol..still m not doing it myself.
@atb2003
@atb2003 14 часов назад
Romex should not be used inside of any conduit due to heat effect from the romex having a shedding around the wires. You also cannot remove the shedding and install the wires inside the conduit since the wires do not have identifying label on the wire itself which comes back to the same comment made on here requiring THHN wires.
@sirpainter1
@sirpainter1 Год назад
Thankyou for this. I see your hands were shakin when removing the 2 breakers. I don't think that was coffee related. My neighbor helped me put in a breaker box in my shop, he was a electrician for the UPRR. And he educated me about installing breakers. I'm going to get that box. Now all I need is a generator. The 6 P's is what I go by. Proper Planning Prevents Piss Poor Performance. Take Care from Wyoming.
@sharpenrightservicesllc
@sharpenrightservicesllc 4 месяца назад
Nice job. I had an electrician install my Inlet box but "said" the local supply house was out of the lock out kit. I am going to get one off of Amazon and add it to my panel for obvious safety reasons. Your video will be super helpful for my DIY. Thank you for sharing this. I'm betting you just go through another pollen season? 🙂
@mcouture8169
@mcouture8169 7 месяцев назад
5:50... yeah.. while swapping out the 17 or so breakers in my 200 amp box, I did the exact same thing with my screwdriver. Scared the bejeebers out of myself.. thankfully before contacting the hots.
@EeEric727
@EeEric727 5 месяцев назад
Doing this in a few weeks to my house. For kicks, I'm an electrical engineer, I got a quote $1k from an electrician. Safe to say I'm doing it for material and time cost and possibly looking for a new job lol. I'm shocked its not a permit/inspection type of job in my county.
@therealkakazi8926
@therealkakazi8926 Месяц назад
Not yet at least 👀
@EeEric727
@EeEric727 Месяц назад
@therealkakazi8926 I pulled a permit. Didn't want to give insurance any leverage. Had to submit drawings and work plan. Installed 50 amp service. I run the house, full load, once a month on a maintenance cycle. Furthermore, I set up a solar panel trickle charger to the generator battery.
@Bailey463
@Bailey463 Год назад
I ordered a generac system. Simple goes on your meter. Plug and play. Only problem for me is it will take 4 months to hook up. Our hydro company is way behind . It's a 15 min hook up . No switches nothing. I have a generator hook up but limited to certain circuits. With new system I can run whole house up to what my generator can handle. 9500 tri fuel generator is what I have.
@TowerHand
@TowerHand Год назад
Very scary Charlie, you did it like I would! Although I need to set up my new shop for a Genny but I happen to have a manual external transfer switch I'll use betwixt the plug and panel load.
@michaelfunk5951
@michaelfunk5951 Год назад
There's back feed on the grounded conductor even for lineman working the system to restore power. The correct way is to isolate the ground/neutral also not just turning it off at the main. Remember it's AC current not DC!
@user-sq5zg3ys5k
@user-sq5zg3ys5k 9 месяцев назад
Good point.
@LTVoyager
@LTVoyager 8 месяцев назад
Not if the service entrance is installed correctly. The neutral and earth ground should be connected at the service entrance. The neutral is also connected to ground at each utility pole typically. So, there is no danger to the utility workers unless the service entrance wasn’t installed correctly or the ground connection has gone bad. Otherwise, this main lockout switch would not be a code compliant installation and this will pass inspection.
@ronaldnaeyaert3653
@ronaldnaeyaert3653 14 дней назад
You cannot use Romex outside in a conduit because it’s a wet location. Against the electrical code. What should have been used is THHN/TWHN individual wires. Did you use schedule 80 conduit as required for exposed pvc? I have a 30a tri-fuel inverter generator with a 50a plug so I used 50a generator inlet plug and #6 THHN wires but a 30a breaker. If I ever get a bigger generator that puts out 50a, I just need to swap out the breaker
@drakos4754
@drakos4754 Год назад
5:21 yes its hot up top and the main leads coming in are at the bottom , the red , white and black is what is feeding that box . you kept putting your hands wright next to them and you cut the Romex casing off 7:52 , I am still cringing just thinking about what could of happened , your very lucky and good luck opening the panel with the cable plugged in . By the way 9:19 those breakers already in the panel have a lot of copper showing , I'm surprised an inspector let that pass when the house was built our the box was updated, that's a sure sign there was no inspector I hope you used 10 / 3 and not 12/3 , just some constructive feedback.
@armyfazer1410
@armyfazer1410 Месяц назад
I re-watched it. Yes, he was too close and nonchalant about movement in that area.
@joey8567
@joey8567 Месяц назад
Use #6 wire and get 50 amp breaker. I appreciate your saftey switch but comfort for a few dollars more.
@douglasbarnhart3324
@douglasbarnhart3324 3 месяца назад
Awesome video thanks.
@jonathanstrand2474
@jonathanstrand2474 Год назад
Wish you had shown a closeup of the generator male plug type and the new generator inlet female socket type. That detail is Online somewhere I’m sure. I have a generator Dunno if my city power IN breaker is a single power switch, like yours, or if I have extra breaker spaces adjacent to it for the lock-out plate and generator IN breakers but the brand new breaker box was installed in 2019. I have a 100 amp service, and no 220 power needs in my house, but I did add a 3 phase 220 power outlet, that is separate from the mains breaker box, just below it. Big round plug with the 3 locking 1/4 round 250v plug ears, it has a lever (leaf?) switch, for its outlet. I put it there in case I hook up a 220 volt trash pump, because I have a slab foundation (stone house built in 3 separate phases 1880-1940) and the ground behind my house is 6-8” higher than the floor is, 110 volt sump pump right where water could come in the adjacent back door. New gutters installed, and bingo, California gets a huge deluge, sump pump is barely needed now as a result! If not for the city power lock out, could that switched sub 220 box be also used as the power inlet for the generator? hence my plug type question, simpler if not safer to bring the generator IN power with that 220 switched sub box I think I’ll hire an electrician 🙂
@spacecoastz4026
@spacecoastz4026 11 месяцев назад
The interlock hardware is not only $20. Try like $80 or more. Should be $20, but not.
@SandcastleDreams
@SandcastleDreams Год назад
Well, that was interesting! In your video where you get ready to turn the power back on...the screen went black and the video disappeared!
@solarstormgames
@solarstormgames Год назад
great vid! I always wondered how to do such a thing.
@aggtown9616
@aggtown9616 2 месяца назад
Sitting in Tx no power got 4 extension cord running to generator smsh this is my next project
@1guysmilely
@1guysmilely Год назад
Good job made it look easy
@ThruDaLenz
@ThruDaLenz 5 месяцев назад
I thought you dont use Romex outside and its not best practice to use in conduits
@nCon808
@nCon808 Месяц назад
Yup that’s against code
@tommycop284
@tommycop284 18 дней назад
So with this setup do you remove the bonded wire from the generator so there isn’t 2 grounds?
@RayLacks
@RayLacks 10 месяцев назад
Good video thanks
@redleaderone8429
@redleaderone8429 11 месяцев назад
i was gonna asl where to get that siding? it looks good like that
@TheBigBoysTable
@TheBigBoysTable 3 месяца назад
Thank u so much
@MM-sq5pf
@MM-sq5pf 10 месяцев назад
I don't have a main breaker, 2019 house, they said because it wasn't code yet
@rhahwaz
@rhahwaz 5 месяцев назад
Awesome thanks I still think it's complicated for me with my disability
@seriousprepper9506
@seriousprepper9506 Год назад
Only thing I did different is installed a 50a box since my generator is equipped.
@workinonhouse
@workinonhouse 7 месяцев назад
Wrong wire, should be THHN, also failed to lock the connector
@armyfazer1410
@armyfazer1410 Месяц назад
He could have used UFB though. Right?
@robertb7362
@robertb7362 8 дней назад
what was the point of this video if you did not turn your main breaker off and turn the generator on to show you made the right connection?
@kevinsanchez-tx8ik
@kevinsanchez-tx8ik Год назад
$20? For the interlock? Where? I paid $120 yesterday
@kysherman
@kysherman 3 месяца назад
Does that run 120 or 240 to the breaker box?
@konglee7284
@konglee7284 Год назад
How much does this cost for a professional to install....???
@josejesusperezgalvan3637
@josejesusperezgalvan3637 7 месяцев назад
13.3 MM2
@brandonnelson4164
@brandonnelson4164 11 месяцев назад
Romex through conduit is not code.
@LTVoyager
@LTVoyager 8 месяцев назад
Quote the code section that prohibits this. Good luck as it isn’t prohibited in any code of which I’m aware (in the US at least).
@Wyatt1273
@Wyatt1273 8 месяцев назад
Only time is it not code compliant is in a damp or wet location. Romex cannot be ran through an underground conduit because that will be considered a damp or wet location. Other than that, it is perfectly legal. You can reference sections 300.5 (b) and 334.12 (b)(4).
@robertworden9810
@robertworden9810 6 месяцев назад
300.9 indicates that outdoor conduit above grade that is exposed to the elements is considered to be in a wet location.
@Wyatt1273
@Wyatt1273 6 месяцев назад
@@robertworden9810 300.9 states “Where raceways are installed in wet locations abovegrade, the interior of these raceways shall be considered to be a wet location. Insulated conductors and cables installed in raceways in wet locations abovegrade shall comply with 310.10(C).” Doesn’t necessarily say “exposed to the elements” but instead it states in “wet locations above grade”. The elements I assume would be rain/sun which is not necessarily considered a wet location.
@rchapoteau
@rchapoteau 4 месяца назад
Was going to say the same thing. It’s an easy way to install it but not code compliant.
@Arctic513
@Arctic513 5 месяцев назад
What Romex do I get for this setup?
@feyrband
@feyrband 3 месяца назад
10/3 if it's to a 240v plug on your generator
@ZenNaster
@ZenNaster 2 месяца назад
We arent gonna mention that the panel cant be opened while the generator is plugged in? 😉
@catladynj
@catladynj Год назад
You lost me after the first 5 minutes. Lolol🙂🙂🙂🙂🙂
@patsycards
@patsycards 4 месяца назад
Should you not test it somehow?
@mannyfragoza9652
@mannyfragoza9652 Год назад
Gasoline engines are only a temporary solution (short term). Then there is the issue of storing dangerous gasoline. A Solar Generator can replace your Gasoline Generator, Its safe no harmful fumes and its quite no one will even know when you are using it to power the things you need. IMO I would throw all my disposable income toward a Solar generator, and use Gasoline only as a backup if it clouds up for more than a week.
@714rooster
@714rooster Год назад
Solar is very expensive and unreliable due to weather
@mannyfragoza9652
@mannyfragoza9652 Год назад
@@714rooster not where i live .But im not talking about a huge solar array to power your house. Im talking portable solar generators. You can keep your Gas Generators and ill keep my DIY solar system. I guarantee your gasoline will runout before the sun does in a SHTF
@user-dc6mg2rk8p
@user-dc6mg2rk8p 11 месяцев назад
@@mannyfragoza9652Not in our lifetime. Probably will if Biden keeps up his shithole administration
@mcouture8169
@mcouture8169 9 месяцев назад
@@mannyfragoza9652 Vast majority of outages are short term (hours to 4 days) where gas will perform better and deliver more amps throughout the day. A TEOTWAWKI or SHTF event requires a different set of rules and investments. Solar is a fantastic option on the survival boards that I follow, but incredibly poor performing for 365 day-to-day power redundancy in a temperate climate.
@mannyfragoza9652
@mannyfragoza9652 9 месяцев назад
@@mcouture8169 solar is a hit and miss with Biden Sun Blocking program. Im guessing if these enviorfreaks have their way Gas will be as scarce as Hens teeth nothing is 100% but Gas short term pretty much rules.
@ketolifestyle68
@ketolifestyle68 6 месяцев назад
id do it myself but i was told it needs a permit
@YanasaTV
@YanasaTV 6 месяцев назад
If you own the home you should be able to apply for your own permit and DIY.
@billionairefaith1
@billionairefaith1 Год назад
How much did this cost?
@YanasaTV
@YanasaTV Год назад
30 AMP Inlet box $35 -$50 depending on the brand you choose. 10/3 wire Romeo 15 feet $65 (ridiculous) Double Pole 30 Breaker $20 -ish About $30 in conduit parts. About $30 for the Interlock Safety Switch on the Panel
@billionairefaith1
@billionairefaith1 Год назад
@Yanasa TV if installed by professional no more than 500 you think? Thanks for the great video and fast response:)
@steelman2544
@steelman2544 Год назад
​@@billionairefaith1 had mine installed by power company in Missouri. Equipment and labor cost me $740. This was for the transfer box, generator plug, and 50 feet of generator cord.
@billionairefaith1
@billionairefaith1 Год назад
@Steel Man thank you so much 💓 💖
@YanasaTV
@YanasaTV Год назад
@@steelman2544 50 feet of generator chord was likely close to $100 of it.
@ontario1727
@ontario1727 9 месяцев назад
honestly, wear electrical gloves when doing this
@Wyatt1273
@Wyatt1273 8 месяцев назад
No need to since he shut off the main breaker. Nothing below that main had power to it. Only thing to be concerned of is the screws and bars above the main breaker.
@joey8567
@joey8567 Месяц назад
Why paint? Clean!🤣🤣
@calvincheney7405
@calvincheney7405 Год назад
you only energized the right side of your main as far as I can tell.
@NobleSavant
@NobleSavant 11 месяцев назад
You can’t tell very far. 220v breaker grabs both bus bars.
@Wyatt1273
@Wyatt1273 8 месяцев назад
The buss bar alternates from the top down to the bottom in each breaker slot. A phase, B phase, A phase, B phase etc. When he installed the 2 pole or “double” breaker, it connected both the A and the B phase.
@otisstrong5114
@otisstrong5114 3 месяца назад
I was curious about that. So it shouldn't matter if the 2 pole breaker is installed top or bottom?
@danielhanson4326
@danielhanson4326 3 месяца назад
What? A waste of everybody's time
Далее
Fake Horse Tries to Blend in with Pack of Horses
00:19
Italians vs @BayashiTV_  SO CLOSE
00:30
Просмотров 2,4 млн
🔥НОВАЯ БАТАРЕЯ?😮
00:40
Просмотров 203 тыс.
How To Safely Power Your Home With a Portable Generator
16:22
7 Backup Generator Mistakes. (Have You Made One?)
8:11
Home Generator Interlock Kit Installation - EASY!
12:56
Fake Horse Tries to Blend in with Pack of Horses
00:19