Pressure Compensated Load Sense hydraulic system explained 

Ollie Olson
Подписаться 1,8 тыс.
Просмотров 11 тыс.
50% 1

Опубликовано:

 

19 авг 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 7   
@AnAn-oz5ju
@AnAn-oz5ju 2 года назад
thank you very much. this rare illustration is worth more than gold.
@ololo9494
@ololo9494 2 года назад
HI! Thank you for sharing this video, it is a very useful lesson, I like it a lot. I also have a question and if you could answer it that would be awesome, but if you don't feel like answering that's good too. So my question is: I've worked with several different machines, and I have an access to service manuals, them machines would have a very similar hydraulic system with LS signal relief, and to actually test the pump load sense differential and cut off pressure the manual would state something like "The hydraulic pump cut-off pressure is set higher than a function control load sense pressure reducing valve. A function control load sense pressure must be adjusted higher than hydraulic pump cut-off pressure to perform this test" so why is that, why the LS pressure has to be adjusted higher than cut off? Thank you
@ollieolson
@ollieolson 2 года назад
You have to override the load sense system and it's relief (load sense pressure reducing valve) so you can get the system up to the pump cutoff (pressure compensator spool adjustment) so you can set this. It's easily done by turning in the load sense spool all the way and deadheading a function. The pressure on the pump output will be the pressure compensating spool value. Set this, and then adjust your load sense spool back to low standby value. Deadhead a function again and adjust the load sense relief until you reach your max system pressure (based on LS relief value) and then you're done. Don't forget to go back an double check your pressures if you need to do a dynamic pressure adjustment on the LS spool for a delta pressure spec.
@jalelsaidi3827
@jalelsaidi3827 Год назад
Can u repeat another video who explain dynamic adjusting Thnks in advance
@benkalunga2551
@benkalunga2551 5 месяцев назад
Thank you so much 👏, would you please do a video on linde pump also ?
@okanturkylmaz4432
@okanturkylmaz4432 3 месяца назад
why isnt PC pressure 3400 lb and LS 3000 lb at stall position?
@jalelsaidi3827
@jalelsaidi3827 Год назад
Whats the rules of the orifice used in LS signal matched with the case Drain line of the pump