Тёмный

R410A Gas Charging in Inverter AC | How to Charge R410A Gas In Inverter AC 

Yogesh Technical
Подписаться 134 тыс.
Просмотров 30 тыс.
50% 1

मैनीफोल्ड गेज खरीदने के लिंक 👇🏻
1 - amzn.to/3OZSuTH
2 - amzn.to/3yg2l1E
3 - amzn.to/3sf0KW3
4 - amzn.to/3vR2SW4
मैग्नीफाइंग टूल खरीदने के लिंक 👇🏻
1 - amzn.to/3uGdffa
2 - amzn.to/3uFoaWp
3 - amzn.to/3gDWLfy
4 - amzn.to/3HTCGgY
गैस गीजर सेंसर खरीदने के लिंक 👇🏻
1 - amzn.to/3xNfmNP
2 - amzn.to/3lsNXMk
3 - amzn.to/3og9j13
-----------------------------------------------------------
Gas Geyser Video Playlist 👇🏻👇🏻
• Gas gyser fault findin...
-----------------------------------------------------------
Our New Channel 👇🏻👇🏻👇🏻👇🏻👇🏻👇🏻👇🏻👇🏻👇🏻👇🏻
/ indianvacci. .
---------------------------------------------------------------
S-U-B-S-C-R-I-B-E
Don't Forget to
Like, Share, Subscribe & press the bell icon [🔔]
Share, Support, Subscribe!!!
Subscribe: goo.gl/FCzYMF
RU-vid: goo.gl/L4y6mC
Twitter: / yogeshtechnicel
Facebook: / yogeshtechnical
Instagram: / yogeshtechnical
Telegram Channel : t.me/Yogesh_Technical
Blog : yogeshtechnicall.blogspot.com...
---------------------------------------------------------------
#R410A #Hvac #Yogesh_Technical
---------------------------------------------------------------
About : YogeshTechnical is a RU-vid Channel, where you will find Technology videos in Hindi, New Video is Posted Everyday
Thank You For Watching 🙏🏻
---------------------------------------------------------------
Tags -
ac gas r410 price per kg , r410 gas pressure in split ac 1.5 ton , inverter ac gas charging , 1.5 ton split ac me kitni gas hoti hai , inverter ac gas pressure , inverter ac gas refill charges , r32 gas pressure in split ac , R410A refrigerant price per kg , Where to buy R410A refrigerant , R410A refrigerant phase out , R410A refrigerant refill , R410a refrigerant properties , R410A Refrigerant Amazon , R410A Refrigerant price in India , R410A refrigerant replacement , R410A refrigerant vs R32 , R410A GWP , R410A ban , R410A refrigerant replacement

Наука

Опубликовано:

 

14 июн 2022

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 40   
@dr.manjeetpaul
@dr.manjeetpaul 2 года назад
बहुत बढ़िया जानकरी उस्ताद जी
@biswajitpramanik7116
@biswajitpramanik7116 2 года назад
Best prosses & Best knowledge sir.
@rakeshsuthar7441
@rakeshsuthar7441 2 года назад
Yogesh bhai nitrojen ka botal lejane bahut dikat hothihe kya dusre fridge ke compressor se pressure testing kare and vaccum pump se vaccum karke by Wight se gas charge kare koi dikat nahigi me bule star me job kartatha us samay tho nitrogen se pressure testing kare the r22. Me bahut kam Kiya he 20 sal se rfm mehu likin ye inverter me bahut kam kam Kiya hu bhai kya ham kam kar saktehe ye rong pretish he bhai
@MrAnweralam
@MrAnweralam 2 года назад
Excellent explained
@swaroopsahoo214
@swaroopsahoo214 2 года назад
@Yogesh Technical जी योगेश जी, वैसे सभी कंपनियों के inverter AC में कोई न कोई Method/Procedure, uske compressor को full load में चलाने के लिए दि हुई होती हैं, बस आपको प्रत्येक कंपनियों के user और factory manual को पढ़ के समझना पड़ सकता है | बाकी टेक्नीशियन को अच्छी और सही ट्रेनिंग देने से कभी कोई हादसे नहीं होंगे, वे टेक्नीशियन अपने कस्टमरों को भी अच्छे से satisfy कर सकेंगे | वैसे मैं पेशे से मैकेनिकल इंजीनियर हूं | पर टेक्नीशियन की job mein bhi दिलचस्प रखता हूं|
@Ashish-oq8pg
@Ashish-oq8pg Год назад
THANKS.
@ManishKumar-yf5ic
@ManishKumar-yf5ic Год назад
Sir mera Split godrej 1ton R410a gas hai jiska current pressure 80hai kya krna chaiye.. Cmnt kre..
@biswajitpramanik7116
@biswajitpramanik7116 2 года назад
दो-तीन AC Mein Aisa problem tha lekin usmein gas change थोड़ा-थोड़ा ka rke compresser ka presser bana ka kam ban gaya. yea sahi hai ya galat pata nahin lekin kam ban ga . aapka video Dekhen Achcha Laga Kuchh sikhane ko mile sir.
@SRElectronicoffcial07
@SRElectronicoffcial07 Год назад
Sir ges kitna psi.rakhna hai ..?
@notyboygifty
@notyboygifty 2 месяца назад
Aap ne iska pure kaam ka kitna charge kiya tha 🙏🙏
@MvrPlant-ej3wh
@MvrPlant-ej3wh 3 месяца назад
Sir Daikin invatar ac me power cool karne par bhi full load pe nahi chal Raha tha gas R32 me bahut dikat ho Raha tha please javab do na sir good video 👍
@YogeshTechnical
@YogeshTechnical 3 месяца назад
दोस्त हो सकता है कि आपका रूप का टेंपरेचर कम हो क्योंकि इनवर्टर एसी रूम के टेंपरेचर और एंबिएंट टेंपरेचर दोनों को वेरी करके ही अपने कंप्रेसर को कमान देता है
@Kashif_anees_03
@Kashif_anees_03 Год назад
Sir mene 410 gas charging ki standing pressure 300 , or back pressure 160 and amp 8.5+ but no cooling or jab ki gas lagbhag 400 gram hi padi ... Kya kare sir please bataye
@YogeshTechnical
@YogeshTechnical Год назад
दोस्त शायद आपका यूनिट अच्छी तरह से वैक्यूम नहीं हो पाया है इसलिए इसमें गैस भी उचित मात्रा में नहीं आ सकती है और इसी वजह से इसका बैक प्रेशर भी ज्यादा है क्योंकि इसमें बाहर का वायु और हो सकता है इसलिए दोबारा से अच्छी तरह वेक्यूम करके रेफ्रिजरेंट को सिलेंडर उल्टा करके ही भरे
@AnilChauhan-uy2fq
@AnilChauhan-uy2fq Год назад
सर r410 का एंपियर कितना होना चाहिए
@haricandaragangurde9802
@haricandaragangurde9802 Год назад
सर410 गॅस 190 लिटर मे डाल सकते है क्या गोदरेज कंपनी की फ्रिज है उसकेस कॉम्प्रेसर मे लिखा है
@Kashif_anees_03
@Kashif_anees_03 Год назад
Air kya aap comment ke jawab dete hai
@rajubandage3118
@rajubandage3118 2 года назад
Best known sharing, thank you sir
@vkcoolingbidar4418
@vkcoolingbidar4418 2 года назад
👍
@tasarrufkhanbijnorwale3056
@tasarrufkhanbijnorwale3056 Год назад
Turbo ka matlab kya hota hai sir
@deepakkadam1625
@deepakkadam1625 2 года назад
Yogesh bhai r32, r290 ko top up kar sakte hai ya nahi.
@Salimkhan84463
@Salimkhan84463 2 года назад
Kr skte ho Aur 410 isliye nhi q ki usme 2 gas ka mixture hota he
@user-dg6uw7gp4m
@user-dg6uw7gp4m Год назад
Sir ges topup kiya he lekin shochna line thnda nahi hora he cooling kam he kay kru
@user-dg6uw7gp4m
@user-dg6uw7gp4m Год назад
Kay kru problem me hu bolo
@ganeshwabale7582
@ganeshwabale7582 2 года назад
Inverter ac ka pumping check kaise kare
@FAiZKiNG9911
@FAiZKiNG9911 2 года назад
भाई 25000 में कोई 1.5ton का एसी मिल जाएगा split AC
@shabbirahmed8026
@shabbirahmed8026 9 месяцев назад
Cooling coil sweating Nahin ho raha hai Pani Nahin ban raha hai
@kakupandit4295
@kakupandit4295 11 месяцев назад
Lg dual inverter AC half gas lay. Raha hai sir ji kya Karn ho sakta hai
@kakupandit4295
@kakupandit4295 11 месяцев назад
Split 1.5 ton
@YogeshTechnical
@YogeshTechnical 11 месяцев назад
Room sensor check
@kuldeeptandan270
@kuldeeptandan270 Год назад
एसी मे रीटन कूलिंग नही आ रही हे और लिकिच भी नही हे तो क्या किया जाये
@Surinder_
@Surinder_ 2 года назад
Galat kaam na kro Flair nut lgge rehndo. Saari duniya flair nut tight krti hai. Baut kam jgah leak hoti hai gas
@satishdhiman2002
@satishdhiman2002 Год назад
कभी तुम आर610 बोलते हो कभी आर३२ और कभी आर२२ ये चक्कर क्या है
@SanjayChauhan-de2kc
@SanjayChauhan-de2kc Год назад
Brazing nahi karna chaiye tha aako.aap ki baato se samat nhi hu.
@devpalsingh7583
@devpalsingh7583 2 года назад
⁰v
@swaroopsahoo214
@swaroopsahoo214 2 года назад
Sir, Panasonic AC, ko agar Full Load mein chalana hai to, aap -AC ko remote se off kar de Ab AC ko Factory Testing Mode mein lana hai to niche bataye hue procedure follow karein. - ab sirf AC k remote ko ON karein - Fir remote mein, COOL mode set karein - Remote mein Temp. Ko 16°C par set karein - Fir Fan ko Full Speed Mein Set Karein - Fir Swing Louver/Flap ko remote mein hi 3rd Position mein set kardein - Fir Aap, AC ke indoor unit ke access door ko kholein - Fir right side mein maujood AUTO/COOL button ko Press karein (ek beep sound ayega) - ab isi button ko press karte hue 1sec k andar hi remote mein Temp. Down ke button ko press kar de. (Dhyan rakhe temp 16°C se niche nahi jayega fir v apko press karna hai). - yeh successfully karne se, Panasonic AC k indoor unit k display mein FU (Full Load) likha hua aa jayega. Aur compressor directly Full RPM mein pahunch jayega. - fir jab aap temp up button press karenge yani 17°C karenge, tab indoor unit k display me HA (Half Load) likha hua aa jayega aur compressor bhi apne aap Half RPM mein chalne lagega. - fir aap jab 18°C skip karke 19°C remote pe set karenge to, indoor Unit k display mein HI (High Load) likha hua ayega aur compressor apne MAX. RPM me chalne lagega. Fir iske baad ap 20°C kar dein to AC apne. Normal functioning mein aa jayegi. Yani display mein 20°C likha hua ayega. Directly aur AC jaise normal functioning karti thi waise hi jayegi. Ye sab maine khud azmaya hua hai apne Panasonic AC mein. Sab AC ke Manual mein likha hua hota hai.
@YogeshTechnical
@YogeshTechnical 2 года назад
बहुत बहुत अच्छा दोस्त आपकी यह जानकारी सभी टेक्निशियंस दोस्तों के काफी काम आएगी आप जैसे दोस्त ही इस टेक्निशियंस फील्ड को आगे बढ़ा सकते हैं जो जानकारी को अपने तक सीमित न रखकर सभी दोस्तों में शेयर करते हैं आप अच्छा काम करते रहे
@swaroopsahoo214
@swaroopsahoo214 2 года назад
जी योगेश जी, वैसे सभी कंपनियों के inverter AC में कोई न कोई Method/Procedure, uske compressor को full load में चलाने के लिए दि हुई होती हैं, बस आपको प्रत्येक कंपनियों के user और factory manual को पढ़ के समझना पड़ सकता है | बाकी टेक्नीशियन को अच्छी और सही ट्रेनिंग देने से कभी कोई हादसे नहीं होंगे, वे टेक्नीशियन अपने कस्टमरों को भी अच्छे से satisfy कर सकेंगे | वैसे मैं पेशे से मैकेनिकल इंजीनियर हूं | पर टेक्नीशियन की job mein bhi दिलचस्प रखता हूं|
@YogeshTechnical
@YogeshTechnical 2 года назад
जी आपसे बातें करके अच्छा लगा आप आप जैसी सोच अगर हर उस टेक्निशियंस की हो जाए जो अच्छी स्किल और अच्छा एक्सपीरियंस लेकर अपना काम कर रहा है उसे समाज में प्रसारित करें प्रचारित करें तो एक अच्छा समाज बिना प्रदूषण का और बिना किसी जान लेवे हादसे का बन सकता है क्योंकि एक उपभोक्ता अपना एक उपकरण लेकर अपने घर आता है जिसकी कीमत लाखों में होती है और अगर हम उसके साथ अच्छी तरह से ट्रीटमेंट नहीं करेंगे तो यह एक मेहनत वाला कार्य हम नहीं कह सकते