Тёмный

Radionics d7412g alarm system 

Arga The Rexouium
Подписаться 959
Просмотров 3,2 тыс.
50% 1

Опубликовано:

 

21 окт 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 15   
@alarmmuseum
@alarmmuseum Год назад
Do you know the exact model of that PIR? It’s a Detection Systems one right? A bit like the Tri-Tech DS series. I haven’t been able to find any info on them anywhere. Edit: it’s actually an IQ220/260 made by Intellisense.
@NyxKemo
@NyxKemo Год назад
The PIR looks to be a C&K intellisense
@alarmmuseum
@alarmmuseum Год назад
@@NyxKemo is the model an intellisense? Only asking because intellisense in the uk is a series of products by Honeywell.
@NyxKemo
@NyxKemo Год назад
@@alarmmuseum i don’t know the actual model of it but the series is Intellisense
@cyberlight22
@cyberlight22 2 года назад
command 1 love that system
@siphonralarms9411
@siphonralarms9411 2 года назад
I didn’t know these systems were also used in the UK
@ArgaTheRexouium
@ArgaTheRexouium 2 года назад
Yep www.ebay.co.uk/itm/142891950565?hash=item21450621e5:g:UokAAOSwa3BbYxEf
@NewAgeServer
@NewAgeServer 2 года назад
I see you're too used to Vistas :P For the record, COMMAND 4 silences troubles, not entering your code + enter. also, code + enter silence and disarms, code + escape silences without disarming. code + escape is also used to clear the display (basically system reset). also also COMMAND 47 resets smoke detector alarms Cool to see a Radionics system in the UK though
@ArgaTheRexouium
@ArgaTheRexouium 2 года назад
we dont really have vistas here instead we have ademco galaxy panels
@blakematusheski
@blakematusheski 2 года назад
How do you activate the fire alarm notification from the panel?
@captainchris2016
@captainchris2016 Год назад
By activating a fire zone (either by a detector, or a manual activation point.
@thomasbored
@thomasbored 2 года назад
Does another alarm sound like that I swear I had an old alarm that sounded like that
@ArgaTheRexouium
@ArgaTheRexouium 2 года назад
Bosch has a newer version with the same tones
@mssecurity1930
@mssecurity1930 2 года назад
Is that american
@ArgaTheRexouium
@ArgaTheRexouium 2 года назад
They exist both here in the UK and America
Далее
vista alarm setoff
2:26
Просмотров 164
System test 16 [Epilepsy Warning] ⚠️
3:19
train go vroom
1:43
Просмотров 125
System test 23
11:52
Просмотров 120
Changement d'Un Boitier Bris Glace
1:42
Просмотров 41 тыс.
sonitrol pulse dialling?
3:07
Просмотров 106
System test 6
7:53
Просмотров 3,8 тыс.
fire alarm test
1:15
Просмотров 318