Refitting a School Kitchen EP.1 | Thomas Nagy 

Thomas Nagy
Подписаться 96 тыс.
Просмотров 77 тыс.
50% 1

Been tasked with retro fitting some LED lights in a school.
(The old lamps were disposed of correctly - Relax)
All of my Caterpillar clothing can be purchased here:
ecs.page.link/...
We would love you to join our quest on Patreon here:
/ tomthespark
Our preferred tool supplier is here:
www.its.co.uk/
DONT FORGET to use the discount code ITSTOM when shopping!
WARNING:
This video is for entertainment purposes only. If you use the information from this video for your own projects then you assume complete responsibility for the results.

Опубликовано:

 

30 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 392   
@loosecannon5813
@loosecannon5813 4 года назад
With cables above suspended ceilings we need to remember the 'premature collapse' reg.521.10.202 That ceiling will come down in a fire of a good size, that 'spaghetti' is going to be a deadly hazard to firefighters. I believe any retrospective work should include making safe that spaghetti, quote for it at the outset - even if your just replacing 1 light fitting.
@JCCamp
@JCCamp 4 года назад
loose cannon he did say metal clips...
@supersparks7770
@supersparks7770 4 года назад
loose cannon well done ? I was just about to quote that myself ? Stainless steel zip or not there shouldn’t be any extra weight added to the ceiling fixings as well ? I’ve seen so many false ceilings collapse due this sort of thing
@pault4793
@pault4793 4 года назад
Correct we need remenber 521.10.202 , unfortunately you need to quote whats on the spec on not forward think, (subject to if you observe a C1, you need to win the work THEN on the 1st site visit let the client know and get as a extra, it you cost in work at tender stage not on the spec you will lose the work , as others will go for a extra after winning the job
@edcooper2396
@edcooper2396 4 года назад
What do you do about the deadly spaghetti that is the collapsed ceiling?
@jonnywilson9117
@jonnywilson9117 4 года назад
@@edcooper2396 that would be on the floor. The same can't be said about the wiring.
@taftse
@taftse 4 года назад
What we usually do in schools is put a small sub-board in the practical rooms so that it is easy to reset the RCB's when needed, and we usually have one key switch (instead of the red button) at the teachers desk to turn on and off all power to the students desks, we found the kids loved to mess with the red button too much and it allows the teacher to only allow the students to use the equipment when they switched it on Also thanks for not cutting the data cables the amount of times I had to re run them because someone wasn't thinking ahead Also my electrician recently replaced a few light fixtures for Led's similar to the ones you put up but they had the ability to click in a small emergency pod in the centre of the panel really neat little panels
@lewistempleman9752
@lewistempleman9752 4 года назад
Great advices 👍🏻👍🏻
@AbsoluteTVYT
@AbsoluteTVYT 4 года назад
I completely agree, as a 16 year old student myself. This is how our refurbished science labs are set up (for electrics and gas).
@acelectricalsecurity
@acelectricalsecurity 4 года назад
Those lights are a good idea and very neat, plus they self test as well, good if you don't have a key switch, they are made by Ansell.
@MaxPlayle
@MaxPlayle 4 года назад
As a student also, I’d agree. It’s useful to have a sub-board in the practical rooms because if the RCD trips then it’s useful to not have to call facilities management staff to come and reset it at a central location, the teacher present could just flick the switch. Also, the red mushroom buttons weren’t played to too badly where I was, although the option to lock them was there...
@tcpnetworks
@tcpnetworks 4 года назад
In Australia - we sub-board EVERYTHING. A 3 phase supply to the room, then a DB with DIN contactors. Neat and tidy, lower-labor fees for yanking cable.
@ra55575
@ra55575 4 года назад
With that haircut mate you’ll fit right into the dodgy neighbourhood.
@Alexander_l322
@Alexander_l322 4 года назад
He probably locked his van because his hair cut stole a bike and is hiding in it in the back...
@tommyk_ketchup
@tommyk_ketchup 4 года назад
speaking as someone who fits data cabling, just want to say thank you for coiling them up and not just cutting them off 🥳
@davepusey
@davepusey 4 года назад
Agreed, but if he didn't mark which socket they originally went to then you've still got to retrace them out again?
@tommyk_ketchup
@tommyk_ketchup 4 года назад
decent tone and probe will make it easy enough to identify the cables, easier than re-running anyhow! although most people will want to upgrade their cabling these days anyway so probably be a new run of cat 6a and just use em as a pull rope 🙁
@Aeontheosophical
@Aeontheosophical 4 года назад
Hi tom we need a video on that Bosch power station!! Where did you get it? How much did it cost? Is it heavy??
@dg2908
@dg2908 4 года назад
42kg; sells for £1800+vat shop.bosch-professional.com/gb/en/product/cordless-power-unit-gen-230v-1500--39399--0600915070#
@byLounoir
@byLounoir 4 года назад
anyone else get triggered by the way he says "contactor"?
@Xenon777_
@Xenon777_ 4 года назад
As for those LED emergency lights, it's best to run those non-maintained. When running in maintained they would usually stay on 24/7 like the one in the background at 17:11. When the LEDs are running 24/7 they will soon reach their rated lifetime which is usually around 30,000 hours. I'd say LED emergency lights are acceptable for using in non-maintained mode but for maintained, I'd still use the fluorescent ones because they of course have replaceable tubes. When the LED ones reach the end of their life the whole fitting will have to be replaced rather than a simple change of tube.
@affy675
@affy675 4 года назад
Nice job that, we do lots of schools, your EM Stop button will need to have a key lock off so the teacher can leave the room locked off when they leave. We usually pull a new sub main to the kitchen and have a local db in the kitchen. Going off track we tend to put T&E in dado trunking as some of the kids like to pull lid off and cut singles with scissors 😑
@JimWhitaker
@JimWhitaker 4 года назад
You should not be interfering with Darwin!
@quigofamily6362
@quigofamily6362 4 года назад
What about extraction? Could get steamy and smokey in that room?
@tncorgi92
@tncorgi92 4 года назад
Was thinking the same. Potentially lots of hot vapor and/or smoke from all those cookers.
@eamonnblake9704
@eamonnblake9704 4 года назад
I hope those lovely slimline led fittings have a decent ip rating 😳😅😂
@mrcaboosevg6089
@mrcaboosevg6089 4 года назад
Probably someone elses job, it usually is
@deltalambda3864
@deltalambda3864 4 года назад
i installed one of those klick connectors in our dining room for the low hanging light above the table so when we have parties or loads of people around the table gets moved aside and the pendant gets unhooked. the downlighters keep the place lit.
@slickmouse
@slickmouse 4 года назад
The trunking will be getting removed because all the little darlings will be charging their phones from it.
@tenelitebrains
@tenelitebrains 4 года назад
Tom Sullivan I thought exactly the same thing!
@bigjd2k
@bigjd2k 4 года назад
Tom Sullivan Does it matter? They’ll just find somewhere else instead!
@MJS-3000
@MJS-3000 4 года назад
@@bigjd2k some schools were built with the skinniest corridors imaginable. They may not mind the students charging their phones. They may just not want them charging them there due to congestion issues. You could keep moving them on, but much easier to remove the sockets, it's good to design a space to encourage the behavior you want in a space.
@mrcaboosevg6089
@mrcaboosevg6089 4 года назад
What's wrong with kids charging their phones? If i had the culmination of 2000 years of knowledge at that age you'd bet your arse i'd have been on it all the time, you would too
@tomharris5777
@tomharris5777 4 года назад
They have to be pat tested
@acelectricalsecurity
@acelectricalsecurity 4 года назад
Is their spare capacity for the additional load, looked like it was only 100amp incomer, didn't see any ct's. Is their existing school kitchen all electric, if it is, you may need an upgrade on the incoming supply.
@andrewscott6078
@andrewscott6078 4 года назад
Too much load ???
@tomorichard
@tomorichard 4 года назад
Anthony charles a lot of schools especially older schools have what looks like 100a supply but have the fuses graded and a CT meter fitted so used load can be monitored by the DNO. Strange the school doesn’t already have a home economics class.
@ryantaylor6335
@ryantaylor6335 4 года назад
Main switch was 250A with what looked like a direct reading meter. Adjacent sub boards with 100 and 125A with lots of spare ways unless i'm missing something?
@jonnywilson9117
@jonnywilson9117 4 года назад
@@ryantaylor6335 Didn't Mr Nagy mention that as well? Or did we both hear and see something that wasn't real? Lol
@johndowney8575
@johndowney8575 4 года назад
I miss the flicker😂😂
@9plusinstalaciones
@9plusinstalaciones 4 года назад
Hahahaahaha
@seventeanine9066
@seventeanine9066 4 года назад
I'm single now but when i wasn't i use to flickher alot
@DanielAntonsen94
@DanielAntonsen94 4 года назад
Mounted the same type of LED panels in Norway as well, love them. You can also mount them in roofs with a tiny housing where you just slide it in.
@josephking6515
@josephking6515 4 года назад
Suggest you don't show your keys when locking your van. Shifty geezer can make a duplicate just by seeing the dimples etc on the key when you show and turn it. If you doubt me, watch the *LockPickingLawyer* 's channel. If you don't know his channel or another lock picking one, he will scare the crap out of you on how quick locks can be picked or opened by other means.
@skamuk1
@skamuk1 4 года назад
AT&T(GB) in Brentford stock that Rehau trunking mate, and they're still open to the public, just closed on Saturdays now. Recently fitted a load of it.
@skamuk1
@skamuk1 4 года назад
If you're floating around near Old Street tomorrow I'm pretty sure I've got a spare one on site you can have.
@seanmac2384
@seanmac2384 4 года назад
Rehau is a 5 min walk from my house. Just might add, their trunking is quality
@daniellovett3126
@daniellovett3126 4 года назад
Good luck with the fire panel Closed protocol adt panel 😂
@123tinhat123
@123tinhat123 4 года назад
Plus most schools are usually picky about who services the fire alarms usually done in house or a reputable fire alarm company, not a one man band.
@ashbashbaby2
@ashbashbaby2 4 года назад
Why didn't you put a single socket in trunking the it could be right way up
@JimWhitaker
@JimWhitaker 4 года назад
Why would you bother with "the right way up"?
@mikeenglish1492
@mikeenglish1492 4 года назад
Rehau Profila Compact, we use it all the time and get it no problem from Edmundsons Carlisle. Your branch should be able to source it from another branch in the Edmundsons group. Nice vid, interesting as usual👍
@djdunc
@djdunc 4 года назад
Nice to see someone else from Carlisle following Tom!
@HeathenGeek
@HeathenGeek 4 года назад
00:00 ooh somebody's been watchin Edgar Wright movies for editing tips 🙂🙂 For the cables I think I would have left them over the grid. The ceiling should be fire rated? plus there's the metal grid to prevent premature collapse? And I think it would be safer. If there was a risk of premature collapse, it would look like sorting that out would be a seperate job. But I'm sitting at a keyboard and not at the job so don't have a clue.
@danfenlon173
@danfenlon173 4 года назад
TOM Have a look at the 3w emergency spotlights, I always fit them in grids now, 100000 X neater than bulkheads.
@GreenHawkConstructionltd
@GreenHawkConstructionltd 4 года назад
Great video as usual I must admit watching your videos have inspired me to start my own channel for my construction company keep up the good work
@considerlizards
@considerlizards 4 года назад
Go for it
@paulharrison6408
@paulharrison6408 4 года назад
No need to use maintenance free connectors before the driver. Connect the flex from the klik box straight into the driver . Much quicker and means 1 less joint plusxsaves on materials. Been doing it for last year or so. As long as the flex is no thicker than 0.75mm which pre made kliks are....then you're sorted mate.
@pault4793
@pault4793 4 года назад
Looked like a 72KVA intake ,a lot of primary schools have that size but not with a home ecomonics room, if its a secondary school seems pretty tight inatke size Use 32a Radials 4.0mm in LFS twin & earth forget rings, have done loads in the london schools, with diversity its down to experience, throw away that on site guide table, extremely unlikey that all hobs / ovens would be on , ventilation never a problem, all the best Tom Also i would consider a seperate board in the intake with i1 main contactor to bring on the board or 2no: 63A 4 pole contactor set up ( subject to design ) and a single stop/start by teachers desk, very rare for independant switches to control each circuit, bit of a waste and overkill in my opinion 4k -5 K value, All the best tom
@robhooton5347
@robhooton5347 4 года назад
Would it been easier to put emergency fittings in rather than swap bulkheads
@simonschertler3034
@simonschertler3034 4 года назад
25000€ + VAT here in Germany for the electrical installations but -1500€ for the disposal of dumpster you have thrown your ewaste in. 🤔 Here every contractor has to dispose his own waste otherwise you get a bill from the customer or the other contractor who has hired the the disposal company.
@laurencehucker6912
@laurencehucker6912 4 года назад
i'd use a multicore YY for the gridswitch/EM stop by the door. feed the gridswitch itself through the em stop button so it breaks the feed to every contactor in one go. also means you only have to pull one cable up to the gridswitch. Also maybe 4mm radials for each station?
@lukephillips1011
@lukephillips1011 4 года назад
Fancy seeing you here! I agree, good idea 👍
@Luki1060
@Luki1060 4 года назад
Laurence Hucker you know I was sitting thinking how I would connect the e stop to all the contactors for separate circuits, but that works perfect! Is it ok to use the same feed for a1 of each contactor? Thanks!
@tlangdon12
@tlangdon12 4 года назад
If you need a way to connect the return from the EM stop to the common of each gridswitch, you could do worse that look at the Phoenix Contacts Distribution Block (e.g. P/N 3002758).
@nickbuckle646
@nickbuckle646 4 года назад
YY Should not be used for fixed wiring/final circuits. I think that was a change in the 18th, same goes for SY. Give it a google, the problem seems to be B.S 7671 does not recognize them being manufactured to a Britsh Standard, think they made to a German spec.
@TheMattSturgeon
@TheMattSturgeon 4 года назад
@@nickbuckle646 cable not being to a BS can be covered by declaring a deviation from BS7671 on the installation certificate. That would apply to NYY (hi tough) too in addition to SY and YY, although I wouldn't be surprised if there's actually a BS that they happen to comply with... There's another reg on not using flexible cable for fixed wiring too, but it doesn't apply to control circuits, so contactors should be ok. EDIT: might be worth reading articles such as this, as there is certainly more to the argument www.whyprysmian.co.uk/sy-yy-cy-cable.html
@jamesrafter7516
@jamesrafter7516 4 года назад
www.tradesparky.com/cable-and-management/trunking/perimeter/rehau-733379-end-cap-180x65mm End cap fella
@pauljones908
@pauljones908 4 года назад
I would install a DB in the room fed via a contactor installed within the incomer section fed 16mm 5 core SWA (depending on loading) abd controlled with a lockable E stop at the teachers desk. This should prevent having all 8 circuits being fed through the same contactor enclosure preventing the danger when working on 1 contactor. Id put a 2A MCB on the auxiliary circuit to protect it. Like someone mentioned before id go for a 4mm T+E LSF radial to each station and keep 1 row on the same phase to prevent 400V between the 2 work stations.. although this will leave 1 phase with a higher load should they have a full class. I couldnt properly see but the 250A main switch is usually a switch disconector BSEN60947-3 so the 250A rating is the maximum current it can break when switching? Unless its a BSEN60947-2 which is an MCCB so it should have a dial underneath the switch at 0.8 - 1 x? Usually the incomer fuses are at 200A for a 250A switch disconnector so will probably need to check first. Ideally probably could have done with a load test when the school is open to check what its current load demand is before installing. Hope it helps and good luck
@lewis94uk
@lewis94uk 4 года назад
Does Eaton have a monopoly on schools or something? Every school I've ever worked in has a Eaton or MEM board fitted.
@paul_my_plumbs_uk
@paul_my_plumbs_uk 4 года назад
Government backhander brown envelopes me thinks🤔🤔🤔 bit like sage accounts making your tax returns electronically
@tomorichard
@tomorichard 4 года назад
Lewis Miller down our way the used to be the local council’s spec but they are great boards.
@dannymcdaid7348
@dannymcdaid7348 4 года назад
I think it's just down to the quality.
@michaelwalker1145
@michaelwalker1145 4 года назад
Probably because you can get parts from a good wholesaler . Try that with a no name odd ball. A good example a new build with an odd ball dis board . The breaker for the compressor was to small, the sparky they used took one look and said he will struggle to get one for it. This was brand new.
@djdunc
@djdunc 4 года назад
Regarding the contactors, not sure what the security is on the classrooms but do you plan on putting in a master key isolator for the workstations? I.e "one key to rule them all" to prohibit some miscreant turning things on whilst staff are unaware?
@milesellis2921
@milesellis2921 4 года назад
Duncan Sanders interesting - Paxton (the people that already do their door locks by the looks of it) have a card reader for uses like that.
@jongurney
@jongurney 4 года назад
Could just use a key to unlock emergency switch and smash the button when the teacher leaves the room....
@dc-sd3gd
@dc-sd3gd 4 года назад
Why not put 2 single sockets in instead of 1 vertical double socket. Makes a neater job.
@paulharrison6408
@paulharrison6408 4 года назад
That's Rehau trunking! Good stuff and lot cheaper than Marshall tuflex etc. Also bottom lid is part of the carcass so negates need to fit bottom lid as per other makes!! Saves time as a result. We used to get ours from Bemco wholesalers
@kurdishzombie
@kurdishzombie 4 года назад
Total guess £5000
@cuezed
@cuezed 4 года назад
Are you still doing certain jobs in occupied homes for example eicr etc in this pandemic? How would you ensure social distancing?
@Fishbait075
@Fishbait075 4 года назад
Endcap details : rehau 733379 www.tradesparky.com/cable-and-management/trunking/perimeter/rehau-733379-end-cap-180x65mm
@AraCarrano
@AraCarrano 4 года назад
Great Video. Release the dimensions for the track and perhaps a viewer with fire rated filament can 3D print one for you.
@jamescrowder1931
@jamescrowder1931 4 года назад
Hi tom I've used that rehau stuff before I got mine through electric centre which Is basically a part of edmundsons
@SparkyDave308
@SparkyDave308 4 года назад
Jesus christ I miss being at work, being furloughed sucks.
@stevenflanigan9558
@stevenflanigan9558 4 года назад
Hi mate just a heads up on the fire alarm panel for future, it’s an addressable adt panel so hard to get the sortware for laptop programming unless you know someone who works/used to work for adt. If you come across faults with devices etc you would need to get adt to programme the heads with address etc which they charge a pretty penny to do. Hope this is of help mate.
@sheargillsparkie9588
@sheargillsparkie9588 4 года назад
I know we can all see you grafting away on the jobs you choose to portray on you tube, but I must say how impressed I am at the condition in which your tools, (and your whole van for that matter) are kept - being in such mint condition. Has lockdown availed you more time with which to keep them mint and much more organised than your average joe spark? Good show!
@thomasnagy
@thomasnagy 4 года назад
Nope, that's how I roll!
@TALyeah
@TALyeah 4 года назад
I would look for the Part Number mentioned in the technical document: www.rehau.com/download/1137412/cable-management-quick-reference-guide.pdf#page=5 short googling -> www.tradesparky.com/cable-and-management/trunking/perimeter/rehau-288565-end-cap-140x50mm
@bad595
@bad595 4 года назад
Damn 40s ago, got here quick.
@couldabin
@couldabin 4 года назад
Here's what you need Thomas! www.tradesparky.com/cable-and-management/trunking/perimeter/rehau-734006-trunking-140x50mmx3m
@david29262
@david29262 4 года назад
I'm not a sparky. But I will go £5500 + vat. Quick question yes the feed is only below where your working but would it not be easier to run a single cable from the feed into the room and in to a dedicated fuse box. This way the isolator and other cables won't have to be run back and forth. Also allowing for if there is a problem it won't trip the whole panel effecting other classrooms, Can a single cable take that much power?
@dc-sd3gd
@dc-sd3gd 4 года назад
32A ring? As opposed to running 2x2.5mm cable, why not just run 1x 4mm@32A?
@JNET_Reloaded
@JNET_Reloaded 3 года назад
them emergancy lights look dodgy asf, i dont like cables that look like that, you could pull that straght out, no clamps or anything, i tend to tie the cable in a knot so its impossable to pull out.
@Free_Runner
@Free_Runner 4 года назад
I would say somwhere 3,5k - 4,5k + VAT
@LSF315
@LSF315 4 года назад
Good video here, Tom and am looking forward to part two. (Don't think I heard you cuss once!)
@whatthedeuse
@whatthedeuse 4 года назад
I’m very surprised in this day and age that they’d still entertain putting halogen hobs in schools with the risk of being burnt once they’ve done their lesson and the rings are cooling still, surely they’d have specified induction hobs 😳 I’d be running in a sub main to the panel board to the left of the DB downstairs and a DB in the classroom as I’m lazy and couldn’t be bothered running up and down the stairs with all the controls cables and radials to the classroom 😂
@RubenKelevra
@RubenKelevra 4 года назад
I would add one red push button per side - so the students can cut the power to the systems as well when something goes majorly wrong. I would use one red button for the teach(with a key) and one cable per "trunk" and also two power feed down to the fuse box, each 32A. It should be plenty. Don't overengineer that stuff.
@jangoofy
@jangoofy 4 года назад
Rehau trunking: www.tradesparky.com/cable-and-management/trunking/perimeter/rehau-733349-data-trunking-base-180x65mm ?
@MrSamgreenham
@MrSamgreenham 4 года назад
Hello sparkys sorry a plumber / pool engineer here barging in but a hug Tom fan. A puzzle I am trying to solve, I need help to run a hammerhead pool vac, usually it runs off of a 12v car battery but I need to use it for a prolonged period of time. Its power lead is long enough to have it on a mains socket well away from a pool. Any help would be appreciated.
@danielchurchill7928
@danielchurchill7928 4 года назад
Would go for roughly about 6k, maybe suggest some extraction on top of that as well.
@9plusinstalaciones
@9plusinstalaciones 4 года назад
As for the cabling on the ceiling grid, I'd mention it to the client.
@scottsparky1
@scottsparky1 4 года назад
Forget rings just do 4.0mm radials
@ops12able
@ops12able 4 года назад
Tradesparky.com for your end caps?
@anthonyforsythe8675
@anthonyforsythe8675 4 года назад
Hi Tom Try Tradesparky.com for the trunking end cap they show stock of the Rehau profila compact accessories
@fatpedro5588
@fatpedro5588 4 года назад
Thomas Nagy's Price It Right 👍🏻
@davepusey
@davepusey 4 года назад
I hope you marked the ends of the data cables with their original socket IDs. As someone who works in IT, this is one of the most frustrating things when data cabling is cut or disconnected but not marked as to where it previously went.
@bobbelsekwol
@bobbelsekwol 4 года назад
Two fire fighters died because the cables weren't tied up or in baskets. The cables fell down when the ceiling collapsed and the ffs got tangled up in the resulting bunch of bastards. Please, all you sparks out there, tie the cables up or put them in baskets.
@SylwerDragon
@SylwerDragon 4 года назад
I don't know..but i would try to use that normal outside light ..as extra in that room where you placed all those led lights.. Because you can see that there is outside light coming to that roof..and it would be bad if you didn't use it.,..but ofc it is not up to you but up to customer..
@stubbzy2k9
@stubbzy2k9 4 года назад
here are the end caps www.tradesparky.com/cable-and-management/trunking/perimeter/rehau-733379-end-cap-180x65mm
@Wedelfreak
@Wedelfreak 4 года назад
That trunking is made by "OBO", so maybe try looking in that direction?
@PaulL42654
@PaulL42654 4 года назад
AC in every tool? Damn wish my school would have had that!
@JoffiPhone
@JoffiPhone 4 года назад
End Cap - www.tradesparky.com/cable-and-management/trunking/perimeter/rehau-733379-end-cap-180x65mm
@twinbuster21
@twinbuster21 4 года назад
Tom all i can say is enjoy working on that fire alarm panel. Its a closed protocol bag of shit :')
@declanwiltshire7258
@declanwiltshire7258 4 года назад
Now you have had the Bosch power tools for a while what is your opinion on them and how well did you get on with your Milwaukee stuff before you switched ?
@djseanie10o
@djseanie10o 4 года назад
Rehau was the best dado to fit ever so handy and cheap enough but they have stopped manufacturing, we had to switch to MK dado
@Xenon777_
@Xenon777_ 4 года назад
T8s are what were in the ceiling lights and the fluorescent emergency lights use T5 tubes
@-chris1965
@-chris1965 4 года назад
£150
@1990Cookie
@1990Cookie 4 года назад
Arent those rooms cold as fuck with that much space above the sealing?
@CjsGfX
@CjsGfX 4 года назад
hey man off topic but what laser level do you use and whats the video you uploaded showing it?
@adriansrealm
@adriansrealm 4 года назад
4500 to 6000 GBP
@jamesmason2034
@jamesmason2034 4 года назад
I’d say for all in about 11k inc vat
@ARElectrics
@ARElectrics 4 года назад
How you are going to do that job you have priced for is exactly how I would had thought to do it, spot on. I estimate the job would be roughly £5,500 plus VAT. I wouldn't do it any different to how you explained. What a great job. What light panels are they I do recognise those, only thing to be careful of is how thin they are, iv known some to sag in the middle over time. Do they come pre flexed aswel? Only thing I would probably do differently is that I would had wired the flex directly from the klick into the driver. That way the only connections are at the driver and at the klick plug. These are great in commercial premises where isolating a circuit isnt possible, you can just unplug the fitting for maintenance purposes. Not alot that can be done with the cabling from the klick boxes though. Sometimes you got to be careful you dont price yourself out of the work.
@PsiQ
@PsiQ 4 года назад
Does that Bosch Powerbrick put out a "real sinus"? For the money you could get a decent USV, but i guess the lipo cells in there are the expensive stuff. (edit: couldnt find anything about the waveform in the datasheet/manual)
@thomasnagy
@thomasnagy 4 года назад
Yeah its a pure sine wave. I can run all my PC stuff no sweat without it glitching out.
@ajhealy2917
@ajhealy2917 4 года назад
In Australia it is againts the regs (Illegal) to tie cables or anything to floating ceiling hangers, you have to mount Cat Wires across the roof void and tie everything to those
@pricey4566
@pricey4566 4 года назад
Exactly my thoughts aj but its funny watching how the poms work it blows my mind australia seems to have a better standard in my opinion than alot of other countries LOL all
@b_141.s8
@b_141.s8 4 года назад
Anyone hate the fact the English man is saying zip tie not cable tie?
@hughieandrolf
@hughieandrolf 4 года назад
My 10p's worth, what my gut woul tell me in 2011 - no research, just pulled it from the sky. . £7.5K not including appliances. 50A 8way TPN sub board in the classroom room in 10mm SWA , 8 contactors in yy multi to switch panel, 30A 6mm radial @ 2x twin switched S/Os to each workstation, plug-in hob and oven. 9 RCBOs to include a teacher's desk supply. Extra £ 850 to up-rate to 80A on 25mm SWA with 100A S/F if no diversity permitted - assuming main supply has capacity and bus bars etc for S/F. It's going to get hot, steamy and wet in there - up to 24kW of heat and possibly 16 pans of boiling cabbage. Offer a free 4" toilet fan venting into the ceiling void :-p
@mrAq_pA
@mrAq_pA 4 года назад
Did u move from Hungary to the UK or u were born there ?
@adamcoles7035
@adamcoles7035 4 года назад
I work in a college with the same trunking. Weve found the easiest place to get hold of spares etc is tradesparky.com do every thing you need for it.
@MichaelDreksler
@MichaelDreksler 4 года назад
It is one of their top sellers www.tradesparky.com/cable-and-management/trunking/perimeter/rehau-288565-end-cap-140x50mm
@landy9020
@landy9020 4 года назад
That dado trunking looks very similar to Schneider dado let me know if it is but certainly looks the same.
@Nono-hk3is
@Nono-hk3is 4 года назад
But Clive sent me. He didn't say to say that.
@7chappers
@7chappers 4 года назад
Will you be keeping all circuits in the room on the same phase so there isn’t a potential of 400v between work stations?
@i_w_sto_koni_nie_dogoni
@i_w_sto_koni_nie_dogoni 4 года назад
load needs to be evenly balanced across all phases, can't dump it all on one
@williamcross3904
@williamcross3904 4 года назад
Great video Tom. Something to watch during this lockdown!!! Looks like one of them jobs that leads to more work the access control stuff looks interesting.
@alexkane07
@alexkane07 4 года назад
What's the best way to become families with installing/ maintaining fire alarms? I don't have any experience with them but it's always been something I've wanted to get into.
@charliebillington1
@charliebillington1 4 года назад
Are you a sparks ??
@ashbashbaby2
@ashbashbaby2 4 года назад
@@charliebillington1 😂
@kristianmiddleton6491
@kristianmiddleton6491 4 года назад
The price is around £4-7K
@NicholasBrownC
@NicholasBrownC 4 года назад
I recently installed some very similar 2'x4' LED fixtures in an elementary school here in the US. Interesting to see that y'all aren't required to safety wire the fixtures to the ceiling with steel wire, and can just lay them in the grid. In my state it's required that each fixture have a minimum of two safety wires to hold the fixtures in case the ceiling grid collapses. I think it's kind of silly with the light weight LED fixtures, but it makes plenty of sense for the older florescence fixtures. Those things are heavy!
@garethhodson3896
@garethhodson3896 4 года назад
Bet those Eaton RCBO’s won’t be cheap? LSF cable as it’s a school, have to watch the phasing and loads on the ovens too. - run a multicore to the switch put the common through the em stop first sounds like a nice job £1k materials £2.5k labour plus VAT but probably double that for London and lockdown work
@daanwilmer
@daanwilmer 4 года назад
Pricing a commercial job as someone who isn't quite used to thinking in those terms is quite difficult, and the actual price is probably several times higher than I initially expected, but still a very fair price (just outside of what I'm used to). As my initial hunch was around 2 grand, a better price would probably be somewhere in the ₤10,000 to ₤20,000 range.
@peto22
@peto22 4 года назад
Use 24vdc contactors, only one control cable for grid switches eg. ölflex 12x0.75
@AndyK.1
@AndyK.1 4 года назад
Toms gotta wire 8 contactors. 😂
@zeebeezoey
@zeebeezoey 4 года назад
Are they not having extractor hoods?
@philipkelly9753
@philipkelly9753 4 года назад
at 70 GBP an hour I'd guess about 1.5-2k for labour and I have no idea about electrical pieces but probably in excess of 1000? So like 3.5K?
@tjunwin106
@tjunwin106 4 года назад
Sounds good, We would put a local DB in the room with a shunt trip main switch so when the EM buttons are pressed it kills the whole DB, you could put a splitter box on that and have the contractors in there, always found this is quicker and uses less T&E and less labour having longer cable pulls! Also have you priced for LSF cable with it being a school/Public building ?
@charleskevill6246
@charleskevill6246 4 года назад
If possible could you do a how to series? I'm a bms electrical apprentice. So as you can guess I dont do anything involving lightning systems, Or fire alarm. Or perhaps explain the basics as you would if you were teaching someone. Awesome video by the way.
@edwardgadsby8327
@edwardgadsby8327 4 года назад
I use to work for the manufacturer of that trunking. REHAU. I’ve actually still got lengths of that trunking with the lid. REXEL supply this if you have an account with them?
@mrishak602
@mrishak602 4 года назад
Merlin Trunking Accessories Stop End 170 x 50mm tool station
Далее
Commercial kitchen fit-out Ep.2
13:08
Просмотров 54 тыс.
#kikakim
00:10
Просмотров 10 млн
Обменялись песнями с POLI
00:18
Просмотров 110 тыс.
Kitchen rewire - Fixing my own errors | Thomas Nagy
16:52
Customer refusing to PAY! 😤 What would you do?
11:48
Live: #RIPJAY OC World Record Attempt #RIPPAUL
3:28:23
Просмотров 404 тыс.
How I INVESTED in my business | Thomas Nagy
24:08
Просмотров 40 тыс.
LIVE: RTX 3090 Overclocking (Air & Liquid Nitrogen)
3:51:46
#kikakim
00:10
Просмотров 10 млн