How to fix ac daikin 1.5 PK inverter which has U2 error on ac type (RKD35GVM4). The U2 error code is the detection of an unstable DC voltage failure on the ac outdoor pcb module circuit. Usually from the official dealer will replace 1 unit of the ac outdoor pcb module. But I will try to fix it, after checking the outdoor pcb module there are 4 230V 900uf type capacitor components that have been damaged. But these components are rarely sold on the market rather difficult to find it. Then I use capacitors on the market, I get a 250V 470uf type capacitor and then I modify it, I wind up the two capacitors to get a value close to above 900uf which is 470uf x 2 = 940uf. And 250V used has exceeded the limit of 230V which was previously used so it is safer. After replacing 4 damaged capacitor components, the air conditioner is working normally and cold again, the U2 error code has also been lost.
serving ac service: whatsaap (081 999 021 433)
Hopefully useful and I say thank you.
#errorU2
#ServiceAcDaikinInverter

Опубликовано:

 

18 май 2020

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 111   
@bengkelpleci6448
@bengkelpleci6448 4 года назад
Mantap bli... Bermanfaat skli ini, kbetulan blm pernh dpt komplein ac daikin. Cocok utk nambh ilmu
@madearsa93
@madearsa93 4 года назад
Suksma mewali banana silver🙏
@bengkelpleci6448
@bengkelpleci6448 4 года назад
@@madearsa93 🙏🙏🙏
@mangsahindra6114
@mangsahindra6114 4 года назад
Mantap bli 🙏ilmunya bermanfaat skali
@DevenTehnindo
@DevenTehnindo 3 года назад
Hadir kawan sukses terus ushanya👍👍
@dwiyuliettedhi5513
@dwiyuliettedhi5513 3 года назад
Semangat dan sukses selalu blii
@bahribahri228
@bahribahri228 3 года назад
Trimakasih mas sangat membantu sy TUHAN BERKATI AMIN
@israeljack4452
@israeljack4452 3 года назад
I know I'm kinda randomly asking but does anyone know of a good website to watch new movies online?
@colinaden2844
@colinaden2844 3 года назад
@Israel Jack I use flixzone. Just search on google for it =)
@agusezra7331
@agusezra7331 4 года назад
Mantap ilmunya bosq...🙏
@madearsa93
@madearsa93 4 года назад
Mkasi bos
@agnisinatria3520
@agnisinatria3520 3 года назад
Keren, AC ku persis kaya gini. Berarti elco rawan juga ya.. tapi gampang juga gantinya
@ebyelektronik8080
@ebyelektronik8080 3 года назад
Mantap kang sukses terus
@waluyosugito1945
@waluyosugito1945 Год назад
Terimakasih mas,,,mantap
@ahmadsuhuri3957
@ahmadsuhuri3957 3 года назад
Mantap bos
@dwiyuliettedhi5513
@dwiyuliettedhi5513 3 года назад
Kalau blii berkenan terimakasih atas respon positif nya
@g33k51ndr0m3
@g33k51ndr0m3 4 месяца назад
Terimakasih Video nya bang, bang selain krn elco yg udh rusak, bagian komponen lagi yg perlu di cek?
@waluyosugito4875
@waluyosugito4875 Год назад
Mantap bang... terimakasih
@madearsa93
@madearsa93 Год назад
Sama2, terimakasih
@muyessarohfaisol1391
@muyessarohfaisol1391 3 года назад
ngecek nya gto apa cma tuk merk daikin apa yg laen juga bli???tlong penjelasanx
@mochamadslamet375
@mochamadslamet375 3 года назад
Bli..kalau untuk ac daikin inverter yang 3/4 pk apakah sama kalau errornya U2?
@lanangpriyayi4441
@lanangpriyayi4441 2 года назад
Kalau pcb udh ganti, pas kontek ke outdoor langsung trip di kwh nya om, solusi nya ap om?
@TriAgung-xq8kx
@TriAgung-xq8kx 3 года назад
Untuk pembelian sperpart dimana pak
@dewadwika91
@dewadwika91 Год назад
Ampure bli metaken inverter Daikin 2 pk eror e6 napinya nggih?..suksma
@dwiyuliettedhi5513
@dwiyuliettedhi5513 3 года назад
AC Daikin Inverter ini in door normal tapi out door kalau mau angkat inverter nya mati
@danishandit8674
@danishandit8674 3 года назад
Bli, mau tny klu daikin cassete 3 pk , error E0 kompresor ga mau jalan , sdh restart tp ttp ga mau jalan, Mungkin bli ada solusi ?, makasih bli..
@indahwulandari8512
@indahwulandari8512 3 года назад
Klo L5 eror knp ya bli? Mohon pencerahannya. Tetima kasih
@Anuj10_01
@Anuj10_01 2 года назад
Bro i am getting U2 error on my daikin AC. AC works well during night but trips during day time. What could be the issue? PCB or something else?
@bojle1293
@bojle1293 3 года назад
bli kok ac daikin saya pas di hidupin remotnya tidak ada suara ttitit gtu,gimana caranya bli
@nurulimanto97
@nurulimanto97 4 года назад
Kalau ac daikin saya outdornya gakmau mati gimana ya om??baru beberapa hari ini ,,biasanya kalau udah dingin mati sendiri lalu hdup lagi,, trus suaranya outdor agak berisik .dinginnya juga kurang tidak seperti biasanya,saya beli ac belum ada 1 bulan
@madearsa93
@madearsa93 4 года назад
Pada pemasangan ac sebelumnya apa sudah di vacuum ? Cek tekanan freon nya apa kurang ada yg bocor ?
@dwiyuliettedhi5513
@dwiyuliettedhi5513 3 года назад
Dan kode error saya cek di remote normal semua
@agnisinatria3520
@agnisinatria3520 3 года назад
Kenapa ga pakai yg 1000 uF aja bli?
@muhammadrusydi1979
@muhammadrusydi1979 3 года назад
Bli, tanya ya.. in ac daikin inverter saya pas d cek kode error d remote ko bnyak yg bib nya 2x (bib bib gt di bbrpa kpde) trus bib panjangnya d u2. Penjelasannya donk bli.. terima kasih..🙏🙏
@madearsa93
@madearsa93 3 года назад
Beef panjang itu kode error nya u2
@electroniccreative7683
@electroniccreative7683 4 года назад
Lokasi dimana bli dipemogan deket tukad badung? Atau dikuta mana
@madearsa93
@madearsa93 4 года назад
Sy tinggal daerah peguyangan bli
@madearsa93
@madearsa93 4 года назад
Peguyangan kangin bli
@santosjabarti1595
@santosjabarti1595 4 года назад
Untuk yg ½ pk daikin apakah sama ukuran kapasitor nya? Klo kita pakai yg 300/350 v boleh gk?
@madearsa93
@madearsa93 4 года назад
Boleh di atas ukuran standarnya lagi sedikit kalo gk dapat yg sesuai.
@gloryus0720
@gloryus0720 3 года назад
Mataken dik bli apakah eror U2 slalu masalahnya di modul outdor bli ? Semoga di balas...salam rahayu bli🙏🙏🙏
@madearsa93
@madearsa93 3 года назад
Iya di modul pcb outdoor.
@bennyhermanto1431
@bennyhermanto1431 3 года назад
Mas ac daikin saya kode error u2 sudah hilang stelah di ganti kapasitornya, kode error sudah tidak muncul lagi, ac sudah di bersihkan semua secara maksimal, tapi tetap tidak dingin, boleh minta sarannya harus gimana ya?
@madearsa93
@madearsa93 3 года назад
Tekanan freon brp ? Ampere brp ? Kompresor sudah bisa running di putaran atas atau tinggi
@dwiyuliettedhi5513
@dwiyuliettedhi5513 3 года назад
Gak muncul kode nya normal beeb panjang di 00
@algazail517
@algazail517 3 года назад
bang, sya ada masalah dngan ac daikin sama persis yg di video kan 1,5 pk outdor hidup, tapi kurang lebih 1 mnit trus mati tidak bisa dingin, kode error tidak terdetekkw elconya bagus semua secara visual bagus pcb oudornya tlong bantuannya bang, trimakasih
@mysevencrew3625
@mysevencrew3625 2 года назад
tukar pcb outdoornya bang
@electroniccreative7683
@electroniccreative7683 4 года назад
Bli Punya Mosfet bekas dan elco bekas gk saya mau beli
@madearsa93
@madearsa93 4 года назад
Maaf sy gk punya bli 🙏
@BelajarTeknik5758
@BelajarTeknik5758 3 года назад
Untuk error' H6 gmana mas
@TheOkaaditya
@TheOkaaditya 3 года назад
Ac saya daikin inverter 1/2 pk error U2, bisa saya kirim modul ke bali utk diperbaiki?
@madearsa93
@madearsa93 3 года назад
Bisa pak, inbox wa 081.99902.1433
@adikusuma9315
@adikusuma9315 4 года назад
Salam Kenal bli,suksma video nya sangat membantu,ada nomer wa atau fbnya?fb Tiang Cahaya Poernama Suksma
@madearsa93
@madearsa93 4 года назад
Gih suksma mewali bli,, wa 081999021433
@joniagung592
@joniagung592 3 года назад
Bang kalau ac inverter daikin tidak bisa high speed putaran kompresor padahal sudah di set di suhu 16 °c + dengan fitur powerfull apa bisanya masalahnya kondisi indoor dan outdoor bersih tapi di low rpm kompresornya?
@madearsa93
@madearsa93 3 года назад
Cek thermis di pcb display sensor kotor atau munkin rusak.
@joniagung592
@joniagung592 3 года назад
@@madearsa93 oke bli di coba dlu
@sempurnasaribin1547
@sempurnasaribin1547 4 года назад
mau tanya mas ini ac uda brp lama ya?? saya mau beli daikin inverter cm pengen tau apa sering erar error??? kalo LG bnyk kasus errornya takutnya daikin ini juga bnyk errornya.. kalo mmg LG inverter error trus daikin inverter error lbh baik saya beli daikin standart aja deh.. tolong kasi masukan ya mas. m,akasi
@madearsa93
@madearsa93 4 года назад
Tergantung keperluan kalo mau beli ac inverter daikin atau LG keunggulan lebih hemat daya listrik bisa di atur, hrg lumayan lebih mahal sedikit dr hrg ac yg standar, untk kerusakan error tidak bisa di pastikan bisa awet 1th atau 2th bahkan bisa lebih, karena sistem kerja sudah di atur oleh modul pcb elektronik dan sensor2. Kalo mau cari yg standar sy sarankan yg daikin buatan thailand lebih awet.
@sempurnasaribin1547
@sempurnasaribin1547 4 года назад
@@madearsa93 kepengen yg inverter mas.. katanya irit hmmm apa betul yah??
@madearsa93
@madearsa93 4 года назад
Iya mas lebih hemat sedikit daya listriknya.
@sempurnasaribin1547
@sempurnasaribin1547 4 года назад
@@madearsa93 oke inverter jarang error ya mas kalo daikin thailand?? kalo mas oke saya mantep ambil daikin inverter thailan aja hehe
@UtheVya
@UtheVya 4 года назад
Saya pny 1/2 pk juga, tp kipas muter cuma AC ga dingin gan.😭
@madearsa93
@madearsa93 4 года назад
Kode error ?
@jonathanlenz4899
@jonathanlenz4899 Год назад
Mas ac kompresor mati nyala, kadang indoor juga mati kedip2. Dicabuy stopkontak nyala lagi. Kode U2. Itu apanya yg rusak? Kapasitorkah?
@acong16
@acong16 Год назад
Ac inverter?
@edyraspati3554
@edyraspati3554 3 года назад
itu kapasitornya VAC apa VDC
@madearsa93
@madearsa93 3 года назад
VDC
@Putra_oka_teknik
@Putra_oka_teknik 2 года назад
Sy jg ada kasus sm u2,tapi sudah sy ganti elcho bagian inverter dn indoor,tp ga ada hasil,apa ada solusi lain pak?
@suladi3264
@suladi3264 2 года назад
sdh ketemu kah ini masalahnya bro? kok pas kasus yg sama
@Brian-lt1yp
@Brian-lt1yp Год назад
@@suladi3264 sudah ktmu kah,sya punya mslh yg sama
@muhammadrusydi1979
@muhammadrusydi1979 3 года назад
Bli, kapasitor untuk ac daikin inverter ½pk brpa ya? Mnt cariin link jual onlinennya ad gak bli?
@madearsa93
@madearsa93 3 года назад
Tergantung type ac inverter beda2
@muhammadrusydi1979
@muhammadrusydi1979 3 года назад
@@madearsa93daikin ftkc15vpm4, ac 2016 klo gak slah bli..
@champoumjun6048
@champoumjun6048 3 года назад
แปลให้ด้วยครับ😭😭😭
@sarudiandika7567
@sarudiandika7567 4 года назад
Emperter kulkas dan AC bisa di perbaikin
@madearsa93
@madearsa93 4 года назад
Bisa saja diperbaiki tergantung kode error nya apa dan tingkat kerusakannya dan part komponen yg rusak ada yg jual di pasaran dan bisa saja tidak ada yg jual part nya. Jadi harus membeli 1 set unit modul pcb inverter nya.
@suhardiliao6284
@suhardiliao6284 4 года назад
Harga berapa itu 1 kapasitornya? Terima service di daerah tangerang gak? AC daikin inverter 1/2 PK model FTKC15NVM butuh yg berapa nilai kapasitornya?
@madearsa93
@madearsa93 4 года назад
Maaf blum terima daerah tanggerang kejauhan sy dr bali mas, makasi.
@eriksuprayogi
@eriksuprayogi 3 года назад
Bang mau tanya kalo AC outdoor nya mati nyala mati nyala sendiri dan AC tidak dingin kenapa ya?
@madearsa93
@madearsa93 3 года назад
Ac daikin inverter? Sudah di cek kode error nya apa?
@madearsa93
@madearsa93 3 года назад
Unit ac indoor dan outdoor sudah di cleaning
@hanifkct1399
@hanifkct1399 2 года назад
kalau sy langsung mati outdoornya...ac inverter.. sy check kode errors ndk ada yg bunyinya lama...
@foodchanel9193
@foodchanel9193 2 года назад
Om klau indoor nya yg tidak nyala kenapa yah om?
@madearsa93
@madearsa93 2 года назад
Ac error, di cek kode error yg muncul apa
@dwiyuliettedhi5513
@dwiyuliettedhi5513 3 года назад
Maaf mau konsultasi blii boleh minta nomor wa untuk konsultasi
@madearsa93
@madearsa93 3 года назад
Boleh, ada di deskripsi pak
@ibrahimhasanudin2445
@ibrahimhasanudin2445 Год назад
Bli error u4 apanya y
@susantoae7481
@susantoae7481 3 года назад
Bos mau tanya unyuk ac daickin teouble L5 kerusakan pada apanya ya ..
@madearsa93
@madearsa93 3 года назад
Error U2 atau L5 itu sama kerusakannya.
@susantoae7481
@susantoae7481 3 года назад
@@madearsa93 maaf master klo u2 capasitor uf nya kurang
@madearsa93
@madearsa93 3 года назад
@@susantoae7481 iya, nilai uf pd capasitor sudah drop/turun jauh dari nilai aslinya.
@susantoae7481
@susantoae7481 3 года назад
@@madearsa93 ni kapasitor da saya ganti ttp L5...😂😂😂😂😂😂😂
@madearsa93
@madearsa93 3 года назад
@@susantoae7481 compresor sempat hidup dan ngegas lalu kemudian error L5. Pada ic ipm harus olesi pasta pendingin suhu pd ic terlalu tinggi pembuangan panas yg tidak baik.
@susantoresas
@susantoresas 4 года назад
Kalo error' h6 ganti apaan gan
@madearsa93
@madearsa93 4 года назад
Kelainan Sensor Posisi Kode Error H6 Metode Pendeteksian Kode Error Kegagalan start-up kompresor di deteksi dengan memeriksa kondisi kompresor menyala melalui rangkaian deteksi posisi. Kondisi Keputusan Error  Jika kesalahan berulang, sistem dimatikan.  Atur ulang kondisi: lanjutkan pengerjaan selama sekitar 11 menit tanpa kesalahan lainnya Dugaan Penyebab  Pemutusan kabel estafet Kompresor  Kompresor rusak  PCB unit outdoor rusak  Kegagalan start-up disebabkan oleh stop valve tertutup  Tegangan input berada di luar kisaran tertentu.
@susantoresas
@susantoresas 4 года назад
@@madearsa93 oke mas ane coba cek satu2 , makasih info nya
@irfansumatra8644
@irfansumatra8644 2 года назад
Itu klo nyemtrum kanapa bos pipa nya,,
@madearsa93
@madearsa93 2 года назад
Grounding tidak terpasang dengan baik.
@irfansumatra8644
@irfansumatra8644 2 года назад
@@madearsa93 efek nya pade kompolen ac indor baik pun autdor klo nyentrum apa efek nya nnti bos
@sutar1230
@sutar1230 4 года назад
AC sy error' U2 master tpi kondisi out doornya mati hidup per 1mnt kira apanya blm sy bongkar sih out doornya mohon pencerahan master
@madearsa93
@madearsa93 4 года назад
Cek kapasitor vdc nya
@sutar1230
@sutar1230 4 года назад
Ok tar sy cek master mksh byk infonya🙏
@sutar1230
@sutar1230 4 года назад
Sdh sy cek master d fcb out doornya tdk ad tanda" ad yg rsk🙏
@madearsa93
@madearsa93 4 года назад
@@sutar1230 kapasitor vdc sudah cek ukur capacitance nya apa normal apa drop.
@sutar1230
@sutar1230 4 года назад
Ok master tar sy cari multitesternya dlu mksh byk🙏
Далее
Diagnosing Daikin U2 Error
20:22
Просмотров 18 тыс.
Penyebab ac daikin inverter outdoor mati hidup
20:20
Просмотров 12 тыс.
Servis AC Daikin Mati Total dengan mudah dan murah
14:11
#Daikin# inverter AC PCB #U4# error
12:09
Просмотров 2,2 тыс.
IMPROVE "F3" ERROR AC SPLIT DAIKIN INVERTER 1 PK
26:17
Kerusakan AC Standing Daikin ERROR U1
8:12
Просмотров 1,1 тыс.