Explaining how when there is a coil leak or a line set leak
this could save the consumer and the technician both time and money, using this when there is a copper line set leak. under ground refrigerant leak start by hooking up high side hose first
then hook up service which is service hose. always purge hoses.
once gauges are installed turn heat pump on. the process will take about one minute. once easy seal is installed leave air conditioning system running for one hour at least.
Thanks for watching!
- David
David@DavidJonesAC.com
Follow me on Facebook: / david-jones-ac-1010702...

Опубликовано:

 

30 окт 2016

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 90   
@AryanIrani
@AryanIrani 4 года назад
Explained it 100 times better than the manufacturer video. Thanks You should write a book!
@jonesacnaples
@jonesacnaples 4 года назад
Fred DaVoudi thank you for the compliment I really appreciate that I’m only here to help Thanks for watching
@jimbola77
@jimbola77 7 лет назад
excellent video david thank you for sharing I love all your video's!!!!
@keithhoward8651
@keithhoward8651 7 лет назад
Keep up the good work David looking forward to more videos from you they are helpful
@DjTechoBeatz
@DjTechoBeatz 7 лет назад
David Jones I want to thank you for all your videos. Thanks!!!!!!
@jonesacnaples
@jonesacnaples 7 лет назад
I appreciate you..
@gerardoreyes9407
@gerardoreyes9407 3 года назад
Great way to teaching ..and understanding...thanks David.
@markhalfmann4426
@markhalfmann4426 2 года назад
Good channel! Thank you david jones!
@mlow42
@mlow42 6 лет назад
We service lots of old units, with low budgets. This stuff is magic. Evap coils and line sets. Sometimes, this is the only option. My gauges are fine. We've lost zero compressors and zero metering devices. Probably 30 units over 2 years or so. We always use detectors, bubbles and high pressure nitrogen first.
@OnePointLander
@OnePointLander Год назад
Any updates?
@mlow42
@mlow42 Год назад
@@OnePointLander I moved into a controls position. So, unfortunately no.
@tonynewswanger5759
@tonynewswanger5759 4 года назад
This stuff only works on very small leaks if you are having to get your system recharged every season it should work. However if you get your system recharged and it all leaks out in a 2 weeks your hole is 2 big for it to seal. I have had success with this product in old systems that have small leaks
@chillwill97
@chillwill97 2 года назад
No Joke Sherlock
@emanuelhighwaymanthomas6123
@emanuelhighwaymanthomas6123 7 лет назад
For sure a video I will add to my list.
@keithhoward8651
@keithhoward8651 7 лет назад
Looks like a good product
@devondknuckles839
@devondknuckles839 Год назад
Nice work David great video man lots of help
@jonesacnaples
@jonesacnaples 7 лет назад
Thanks for letting me know. I have never been a big fan of leak stop.
@tinicumdad648
@tinicumdad648 4 года назад
Have you ever used Procharge Products R22 Recharge Dye and Sealer? It comes with a gauge on hose and can of R22 with dye and Sealer. I wanted to add to my 25 year old system which I've been told is 3lbs low. It seems to have a small slow leak. Seems pretty simple to use. About to try but wanted to see if anyone else has done it.
@donio71
@donio71 4 года назад
Good advice
@iambethal
@iambethal 6 лет назад
Today I was in a cloud of 410a and easy seal. It jacked me up and I had to go home. I can still feel the sealant in my nose. By the way last year i installed the easy seal. I was back for a low charge. Also my ratio was messed up 1 to 2. Or my gauges are way out of wack.
@airmechanical7163
@airmechanical7163 7 лет назад
Great video.
@jonesacnaples
@jonesacnaples 7 лет назад
I appreciate it.
@jess8075
@jess8075 20 дней назад
Thank you for the video. What about purging the service (yellow) hose, like you did the high-pressure hose? Thank you.
@JohnDoe-vf8cw
@JohnDoe-vf8cw 5 лет назад
I didn't notice you purging the service hose before connecting it to the easy seal
@Member-el4zo
@Member-el4zo 4 года назад
I agree, he needs ball valves on the ends of his hoses then he could have purged the yellow hose then connected it to the tube. Otherwise there had to be some trapped air in the yellow hose. I used this stuff on a lineset leak under the slab which was a a small leak but it took I think 3 times. I would use it again but it would depend on the age of the equipment and where the leak is. Obviously it will never work if it's too large.
@trlc1122
@trlc1122 4 года назад
I've watched 3 videos on this EZ seal and each guy did it wrong, including this guy. The irony is he started with "always purge your hoses" then he didn't.
@chris6245
@chris6245 5 лет назад
Mr. Jones, did you have any issues with this system after using the product on it or did it solve the problem?
@jonhvac
@jonhvac 7 лет назад
That was too easy👍
@jbaz964
@jbaz964 3 года назад
how long do I have to wait to add refrigerant following the Easy Seal?
@martinwoods6716
@martinwoods6716 4 года назад
Did you or will you be doing a follow up video to see if product works...?
@kilo1177
@kilo1177 5 лет назад
What if it dont have pressure
@genekerr8064
@genekerr8064 6 лет назад
Great instructions! Should refrigerant be added before or after the sealer in installed? Thank you.
@heltonms3041
@heltonms3041 2 года назад
I have the same question. Please, let me know in case you figured it out. Tks
@harwoods11
@harwoods11 Год назад
Late answer... The system won't engage the air conditioning system compressor unless there is gas pressure. So the system must be partially charged and then add the leak sealant. Run for a period of time then top up and do a leak check. Doesn't work on large leaks so best to do a dye test first.
@igorfim1980
@igorfim1980 Год назад
@@harwoods11 Hi ,what do you mean large leak? I have to add refrigerant in 20 days in my system is it large leak? Thanks
@eduardodavalos7818
@eduardodavalos7818 5 лет назад
Thank u sir
@robd7365
@robd7365 2 года назад
How is is done in a mini-split that only has a service hose port on the low side? Thanks
@jamescc2010
@jamescc2010 3 года назад
How did it go? My system is flat right now and After an AC tech came and check it out, he said our line set under slab was leaking and we lost everything all Freon. I don’t I’m not sure how big the leak is. I’m thinking of attempt to try One of these products to see if I’m lucky so I have to spend 8K to 10 K to replace the system.
@fhiggenbottom
@fhiggenbottom Год назад
Would Calgon Easy Seal work to seal a refrigerant leak in the evaporator coil which sits atop the furnace on our dual fuel system? Our heat pump started not cooling properly (cooling only to 75 degrees and no lower) and the technician who came to look at the problem found evidence of refrigerant oil in the evaporator pan beneath the coils. But try as he may the A/C technician couldn't find the leak with his sniffer. He stated only a new system would resolve the HVAC problem. I'm now debating whether to have a new (and expensive) duel fuel unit installed or find a technician who would try this product. With the price of freon and the kit required to recharge the system this could be a nearly thousand-dollar gamble but compared to approximately $9,500 that was quoted for a new system to be installed it might work. Your thoughts would be appreciated.
@darleneaparicio1500
@darleneaparicio1500 2 года назад
I had a technician come and service mine because it had a leak supposedly they fixed it but then it did not work again then I had another technician come out and put in the stop leak and to check for the leaks but it had not worked either and it have Freon sprayed all on the outside of the unit it is a Rheem and I have had problems with it from the beginning when they installed it now this person wants to put in another new units this one is still covered under the warranty what would be my best option
@jimroberts6176
@jimroberts6176 2 года назад
Can this product be used more than one time?
@wakawaka1976
@wakawaka1976 2 года назад
Anyone know how much this costs to get done?
@HVACShopTalk
@HVACShopTalk 7 лет назад
This unit looks really new. If a contractor installed this unit on a leaking line set then the vacuum could not have been properly done. If that is the case then couldnt the easy seal be activated by the non condensibles in the system?
@HVACShopTalk
@HVACShopTalk 7 лет назад
yes sir
@justin0957
@justin0957 7 лет назад
This is forsure a Trick not a Treat
@theairconditioningguy
@theairconditioningguy 4 года назад
Lol!😂
@meerscan9101
@meerscan9101 7 лет назад
use a cheap set of gauges or super short hoses with z-manifold...
@cooldude2245
@cooldude2245 Месяц назад
Does this work?
@Imwright720
@Imwright720 4 года назад
The evaporator core could be leaking. You didn’t say if you isolated and did a vacuum test
@SnifferAndFrens
@SnifferAndFrens 5 лет назад
100ft underground? 🤨
@kirkmaluo
@kirkmaluo 5 лет назад
David, did the product work for the custom? How often have you used it. Has it ever damaged equipment or gauges in your experience?
@nocompeterefrigerationserv7501
David Jones- Not to be a assistance but that shit will ruin your expensive guages. If you have a leak in the line set either repair the pipe or replace. **Line-set should not be buried, not code** Besides this you have great videos.
@jonesacnaples
@jonesacnaples 7 лет назад
I agree it should be against the law..to have buried line sets thanks for your advice
@StateofPeaches99
@StateofPeaches99 Год назад
Ive been watching your videos for I know at least 7 years. Im looking for a ac sealer and didn't know which to buy. I looked no farther for a product.
@ATCMechanicalIncWoodstock
@ATCMechanicalIncWoodstock 2 года назад
I guess the yellow hose doesn’t get air in it and doesn’t need to be purged
@dsd-downshiftdave8056
@dsd-downshiftdave8056 Год назад
If you have a leak do you top up the Refrigerant before or after you use easy seal? And did this repair your leak???
@bigneilh
@bigneilh 3 года назад
I have a silly question: he didn't purge the service line (yellow) so what happens to the air in that line? Thanks!
@bigneilh
@bigneilh 3 года назад
Ok maybe he did bleed that line but did he bleed after the leak seal? I would think before, no?
@exposingscammers1atatime246
@exposingscammers1atatime246 3 года назад
You add the Easy fix before you fill the freon back up, correct? So it is still below 5 lbs? I have a very small leak that I believe this will fix great but of course the AC man said no, it was a joke. I beliebe it will be fine. Do you have a video for us NON AC repair guys on how to use the gagues? I'm guessing the high pressure side is in the back and low is in the front. Your Expertise is appreciated!!
@exposingscammers1atatime246
@exposingscammers1atatime246 3 года назад
Guess no one answers questions on their videos, I really needed advice but guess not. Thanks for nothing. Smh
@Jetsi79
@Jetsi79 3 года назад
@@exposingscammers1atatime246 Did you do as you stated and fill the Freon after using the easy fix ?
@bigneilh
@bigneilh 3 года назад
do you top off refrigerant first or after doing this?
@heltonms3041
@heltonms3041 2 года назад
I have the same question. Please, let me know in case you figured it out. Tks
@sergioperez2771
@sergioperez2771 Год назад
You said "always purge your hoses," but you didn't purge your service hose (the yellow hose) before sending pressure through the injector into your system. How are you supposed to purge the service hose with these injectors? Surely there is some air in the service hose that goes into your system using the method shown in this video.
@Capafool
@Capafool 3 года назад
How did you go about purging the yellow line? you purged the high side but didn't see any purge on the other line.
@husslegrind1931
@husslegrind1931 3 года назад
David will you add in the comments how to purge the yellow/service line before connecting it to the sealant !
@JH-nf3fu
@JH-nf3fu 3 года назад
I don’t think he purged the yellow line and pushed air into the system
@ritewayguy
@ritewayguy 7 лет назад
I think a new lineset should be installed....above ground.
@martinwoods6716
@martinwoods6716 4 года назад
Did you FollowUp with the easy seal and what is your opinion after using several times... Do you recommend or is it a waste of time and money...?
@notanewbie1718
@notanewbie1718 4 года назад
@@martinwoods6716 - Compressor manufacturers do not want it in compressors under their warranty. This "stuff" might work on very small micro leaks. I don't really recommend it, but will use it if the customer insists. But I tell them the odds of it working are very low and make sure they understand this. Write this up on their invoice and have them sign it, agreeing that they know it probably won't stop the leak, but they choose to have it put in their system by their choice. Fix the leak or replace the system or the Acoil which is where the leak is 99% of the time............ or throw your money away on sealant that doesn't work hardly at all.
@martinwoods6716
@martinwoods6716 4 года назад
A lot of Home Warranty Companies want you to use it... Like you said, they assume responsibility. I’ve always repaired the leak or replace the equipment if necessary. I try to see what other Contractors try also, no need to reinvent the wheel sometimes.... Thx for replying back, I’ll continue to follow....
@notanewbie1718
@notanewbie1718 4 года назад
@@martinwoods6716 - I won't work for home warrnty companies. They have a bad reputation with a lot of techs. Thank you Martin. God Bless.
@RobHVAC
@RobHVAC 7 лет назад
Still not a fan of sealant but with a buried lineset I guess that's all you can do. They should ban buried linesets
@jhhvacplumbing1944
@jhhvacplumbing1944 7 лет назад
I don't know about that stuff , good luck David .
@jonesacnaples
@jonesacnaples 7 лет назад
I would have to go through 4 fire walls. this would be very expensive for the owner. I was trying to safe money and time.. wish me luck....
@RobHVAC
@RobHVAC 7 лет назад
***** yep
@gearloose503
@gearloose503 5 лет назад
Try-ed it. Now the reversing valve won't cycle.
@dallasyopp9483
@dallasyopp9483 3 года назад
I have 150 ft of line on a mini split system with 4 zones how many would I need
@ronprice1989
@ronprice1989 3 года назад
You need to reflare
@nealedmondson3191
@nealedmondson3191 3 года назад
You need to learn how to flare. PERIOD.
@joannedziedzic5184
@joannedziedzic5184 2 года назад
Hate to tell you you need to add to the suction side not the high side using it on the high pressure side you. Will trash the compressor
@RoadieWingZZ
@RoadieWingZZ Год назад
He did inject it into the low side. The high side connector was used to supply the pressure to push the sealant into the low side.
@StockDude
@StockDude 5 лет назад
tech used this stuff on my R22 system. Says it seals small or larger holes. Total BS. I spent $600 on freon to boot and this sealer doesn't work. Don't waste your money on it.
@aiymankhan7222
@aiymankhan7222 4 года назад
Alot of my clients are having efficiency issues due to bum techs putting AIR into the system, and the worst thing you have to gamble guess what's the problem, most of the time I just vacuum and recharge the unit with new refrigerant that solves their problem 80-90% of the time. Just if tecs could pay attention, stop putting air into systems and stop releasing refrigerant into the air we could make this would a better place to live in.
@jefflohr5533
@jefflohr5533 5 лет назад
You didn’t purge your charging line😂! Remember to purge guys! Ive been doing AC work for 23 years and I just fix the frikkin leak I never use this shit right here!😂🤣! This is a jack leg way of doing things!
@jfmc2581
@jfmc2581 2 года назад
I really don't think you did this right .. every other video shows it shoot in in less than a second... How do you PURGE the gauges and lines??? As soon as it's connected everything goes right in the system unpurged AIR AND MOISTURE!! seriously what about this how to avoid??
@nicolas0065
@nicolas0065 7 лет назад
cheat :- ]
@zack9912000
@zack9912000 7 лет назад
Highly do not recommend, causes compressor failures. Pure snake oil.
Далее
Я КУПИЛ САМЫЙ МОЩНЫЙ МОТОЦИКЛ!
59:15
How to use A/C Leak Freeze
4:31
Просмотров 142 тыс.
DOES A/C STOP LEAK REALLY WORK???
4:13
Просмотров 320 тыс.
PRODUCT REVIEW #1: EasySeal UV DYE
9:38
Просмотров 36 тыс.
Cheap Geo Thermal Air Conditioning
14:57
Просмотров 1,4 млн
HVAC 159 Why evaporator coils leak (Fixed)
10:56
Просмотров 53 тыс.
AC Leak Sealant Installation AC Leak Freeze Pro
2:20