Watch as our team walks you through how to repair and rebuild the 600XL water pressure reducing valve.
Note this video is more than 4 years old and may include some out-of-date information. Please refer to Zurn.com for current information and instructions.
Visit the 600XL product page on Zurn.com for more information! www.zurn.com/p...

Опубликовано:

 

26 авг 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 20   
@minifoil6613
@minifoil6613 2 года назад
Fixed my 1-1/4 600XL after 20 years. Wrapped 400 wet sand paper around 1/2 inch socket extension and rebored the bore as this video suggests at 1:40 but used a power drill. Replaced the small o-ring on 5/16 ID 1/8 thick from Home Depot for $2.95 for 10pcs. Flat sanded the rubber seat on grid 400 wet. Replaced the pressure adjustment screw on stainless steel from Amazon for $12 fo 8 pvs with nuts. All the other gaskets and membrane were ok. I think my valve stopped holding pressure 10 years ago. I did not notice because my city pressure is 60psi. Rebuild kit would not work unless you refinish the bore for the small o-ring and the o-ring in the kit is too small to seal the new larger ID bore. Valve design could be better. They know that the bore is the weak spot and should have a stronger fitting in it for it does not errode as much. And it should have 2 redundant o-ring.
@pauljoseph6629
@pauljoseph6629 3 года назад
Will miss ur demonstration which helped me alot..
@James-oh4xd
@James-oh4xd 7 месяцев назад
I had to use a brass wire brush drill attachment to get the patina off the bore of my 70XL. Limited access made things difficult. I tried for hours with sandpaper ranging from 400 grit to 100 grit with various instruments (socket, allen key, finger) and had no luck getting anything off the o-ring bore. 10 seconds with the wire brush on a drill and the patina came off easily.
@jameshotz1350
@jameshotz1350 6 месяцев назад
I tryed 3 ZURN600XL regulator and they all have leakage, where as the pressure goes to line pressure and the relief valve actuates, it has noting to do with the water heater, the plumbing store won't give me refund, what can I do? James Hotz
@longdriver2
@longdriver2 4 года назад
Tried to call the service department the number on the screen(1 888 one zurn) and got connected to AT&T . maybe I missed it, but there's no number to push to connect to Zurn customer service??? HELP!
@ZurnIndustries
@ZurnIndustries 4 года назад
I'm so sorry for the inconvenience! The number is actually 855-one-zurn (or 855-663-9876) - we need to update this video to show the correct phone number. Thank you for your comment!
@johna9033
@johna9033 4 года назад
Hello, My PRV acts more like a flow regulating valve after 5-6 years of service. What I mean is that no matter the adjustment I give the bolt, my gauge reads ~76 PSI even if I close the isolation valve and drain system before checking pressure. But when I open the hose bib with no gauge on and adjust it, I can tell a flow/pressure change. Does this indicate that a rebuild is in order given the o-ring seat is serviceable?
@ZurnIndustries
@ZurnIndustries 4 года назад
All Zurn Wilkins Pressure Reducing (regulating) valves, such as the Model 600XL, are design to reduce the incoming pressure in both the static and flowing conditions, to a safe downstream system pressure. When a PRV fails to hold pressure in a no-flow situation, that may indicate a failed sealing component within the valve. A repair kit, or at a minimum, cleaning and servicing the valve may resolve the issue. It is common for a valve to continue regulating under flowing conditions, as the sealing components are not closed when the valve is flowing. In some cases thermal expansion can be misidentified as a failing PRV. For more information on this scenario, or for help troubleshooting, please call our Customer Service number (1-855-ONE-ZURN) to speak with a product technical support specialist.
@granvillejones9225
@granvillejones9225 2 года назад
I have the Wilkins 600 pressure reducing valve in the main line by the water heater.. However, pressure is too low and adjusting the screw in or out makes no difference in the pressure. We are new owners and am told that the valve was installed to reduce what was once excess pressure. Any suggestions as to what the problem might be ?
@chrissewell1608
@chrissewell1608 Год назад
You don't show to install anything! WTH?
@ZurnIndustries
@ZurnIndustries Год назад
Hi! Here is an installation guide on the 600XL: www.zurn.com/media-library/web_documents/pdfs/installation/is600xl-pdf
@MrMindlink
@MrMindlink 9 месяцев назад
@@ZurnIndustries Thanks for the link, helpful... but I think what Chrissewell meant, is that we expected to see the valve rebuilt in this video.
@christopherloughlin302
@christopherloughlin302 4 года назад
I have a Model 600 3/4 inch. There is a small pin hole at the top of the bell.. Is that whole supposed to be there? I have a small drip of water coming from that whole. I am thinking if the pin hole is supposed to be there then I have a damaged O ring or Diaphram and I can purchase the repair kit.. Thoughts?
@Moes1n
@Moes1n 4 года назад
Christopher Loughlin Coincidentally I just encountered the same problem. When my sprinklers turn on water suddenly shoots out of the pin hole at the top of the bell. I was wondering if that hole was supposed to be there or not, but in doing some research determined that if the diaphragm is intact and functioning there shouldn’t be water in the bell anyway. Did you ever determine the culprit?
@ZurnIndustries
@ZurnIndustries 4 года назад
All Zurn Wilkins PRVs such as Model 600XL operate with a dry bell housing this prevents water from corroding or negatively affecting the spring and other components. A worn diaphragm or loose diaphragm disc and retaining bolt may allow a leak into the bell housing of the valve. If you ever experience water leaking out of the valve it is time to have the valve serviced and inspected. It is very likely that a repair kit may be needed.
@Putrid186
@Putrid186 6 месяцев назад
The way the furniture on the left side in the back blends into seemily the same material towards his hip, and at the same time on the other side of the table, the crosscut pice where the open face lines up PERFECTLY with the edge of the table, was REALLY messing with my head the first 30 seconds like this was some sloppy green-screen chopped up post production crap. But nope, just a camera in a room with a dude and some really coincidental things.
@PetePuebla
@PetePuebla Год назад
The number at the end of the video is wrong. It’s actually 855 not 888
@rodrigoluna9892
@rodrigoluna9892 4 года назад
How can I tell what kind of valve, I have if the tag on the valve is missing? I'm trying to rebuild it. Help.
@abbeyhickmann8344
@abbeyhickmann8344 4 года назад
Hi Rodrigo! Thank you for your question. The easiest way to tell which model PRV you have is to take a look at the body of the valve. All of our valves have the model number casted into it. If you have a 600XL or a NR3XL, etc., it will all be shown on the body. If you have any further questions feel free to email me at abbey.hickmann@zurn.com
@bludika
@bludika 6 месяцев назад
so much talking and nothing of substance
Далее
Water Pressure Regulator Valve Rebuild
13:53
Просмотров 21 тыс.
How To Install a Pressure Reducing Valve
15:24
Просмотров 114 тыс.
Oh No! My Doll Fell In The Dirt🤧💩
00:17
Просмотров 3,7 млн
拉了好大一坨#斗罗大陆#唐三小舞#小丑
00:11
I Took a LUNCHBAR OFF A Poster 🤯 #shorts
00:17
Просмотров 2,7 млн
CSA XLC 370 470 vanne de niveau altimétrique
2:46
Просмотров 7 тыс.
CSA XLC 310 410 pressure reducing valve
2:39
Просмотров 33 тыс.
Zurn Z130S and Z131S Siphonic Roof Drains
4:48
Watts PRV - Reducteur 11Bis 2016 HD UK
1:51
Просмотров 78 тыс.
Oh No! My Doll Fell In The Dirt🤧💩
00:17
Просмотров 3,7 млн