Rheem 36kw Tankless Water Heater Install 

phog_vision
Подписаться 245
Просмотров 19 тыс.
50% 1

DISCLAIMER
I am NOT a professional or expert. I am a DIY home owner. This video is NOT step by step instructions on how to install a tankless heater. It's simply an overview that hopefully helps others trying to figure out if they should attempt to do this themselves or hire a professional. I made the video simply because I couldn't find a lot of resources out there and hoped this would be helpful for others. If you're unsure of your skill levels regarding plumbing and electrical work I recommend hiring a professional to help with some or all of the install. Best of luck!
NOTE: You MUST install a discharge pipe on your relief valve. The video doesn't include that but I did install one after the fact.
Rheem 36kw tankless water heater.
Link to clean out valve set:
a.co/d/9FFU6jH

Опубликовано:

 

23 авг 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 56   
@mgaitan22
@mgaitan22 7 месяцев назад
Got the same one, and yes the flickering of the lights every time we use hot water. My son thought the bulb was going out. But yes it's a small problem, other then then that it's spotless.
@help797
@help797 18 дней назад
Excellent presentation and installation, Thank You!
@justinballard6528
@justinballard6528 Год назад
I could not find the size of the electrical knockout in the manual and we are installing this soon. Rheem hung up on me twice. Thank you for that information!!! This will save us the running around that you had to do:)
@skalnican
@skalnican 11 месяцев назад
Glad it helped. Part of the struggle was figuring out all those little details. But that's why I posted the video.
@johnever3226
@johnever3226 Год назад
thank you for the video ,, i am installing one just like it and will follow your direction to the T .. thanks again ..
@ronfrauenfelder5879
@ronfrauenfelder5879 Год назад
Thank you very much, for the insightful video. I’m about to install a 18 KW Rheem one, you really helped out!
@skalnican
@skalnican Год назад
Glad it helped out. There’s not a ton out there. It’s not hard, but you want to do it right. Good luck!
@otorres915
@otorres915 Год назад
Great video! I’m in the process or researching and trying to figure out what I need in regards to power. I only have 150amp panel. Was looking to install this 36kw until but might not work with my panel. I only have a 2 shower home with a inlet water temp of 72/75deg
@skalnican
@skalnican Год назад
Probably way too much for your panel. But one of the smaller heaters might work. Just make sure you check the specs out. Good luck!
@kathyern861
@kathyern861 Год назад
On the elbow fitting near the hot water cleanout there is a pressure relief valve, you need to install a vertical pipe going down toward the floor, ending a few inches above the floor. If pressure builds up for any reason, that pressure relief valve will open, spewing scalding hot water out the elbow. If you get near the hwh when this hot water is spewing out, you are going to be severely burned.
@skalnican
@skalnican Год назад
Good point. I hadn’t installed it when I did this video but you’re correct.
@kathyern861
@kathyern861 Год назад
@@skalnican then let me make one more final point. You make a video to show thousands of people how to "correctly" install something - and because you did not do it right - guess what you have done - you've just shown all of them how to do it wrong, when they think you are the "expert" who did it right
@skalnican
@skalnican Год назад
I made a video as a guide to help others trying to figure out if they should attempt this themselves since DIY information on these heaters is limited on the internet. I never claimed to be an expert. I showed everyone that the product recommends professional installation (albeit in a lighthearted way). With that said, your point is valid and accurate. I've updated the description of the video and added 2 captions in the video regarding the discharge pipe. I opted against re-uploading the video because doing so would delete the comments that I believe are helpful towards the conversation. Thanks for your observations.
@kathyern861
@kathyern861 Год назад
@@skalnican Wow, I'm stunned. I see the words "thank you" - first time ever for me. Your intentions were good (help others). I could say more, but I think you're an introspective person and have already learned from your mistakes in this case. Farewell.
@donhuffer5167
@donhuffer5167 Год назад
I don’t believe the pressure relief valve is needed or required on a tankless. So the vertical pipe is not needed either.
@elvispressedtalot9899
@elvispressedtalot9899 11 месяцев назад
Now im curious!! How HOT was the water?? You showing installing. but not showing the results, of how hot the water got! Thermal camera
@skalnican
@skalnican 11 месяцев назад
Your comment got me thinking...so I checked it out. The water heater is set to 125 F. The water temp at two faucets, one close and one far from the heater, is 120 F.
@fixitcarter
@fixitcarter Год назад
Greetings, great content. Im actually in the process and a little stuck at the breaker box. Once I get past that I can move forward. Im studying up on code now my system is a baby compared to yours, im thinking i may have to upgrade.
@skalnican
@skalnican Год назад
Who knows, you might be good. 36kW was probably overkill for me. Best of luck to you!
@fixitcarter
@fixitcarter Год назад
@@skalnican done it actually works out, and got it done within code. Thanks again!
@jaredhollaway1766
@jaredhollaway1766 5 месяцев назад
Per code you need a form of disconnect for your electrical at the water heater. Can’t go just straight in with conduit, you should have a fused disconnect on each circuit.
@skalnican
@skalnican 5 месяцев назад
Interesting. Both the heater and circuit breaker are in the garage within site of each other. Is that enough?
@Westwingplumbingyt
@Westwingplumbingyt 2 дня назад
Can this go outside ?
@SviiiSavageWraith
@SviiiSavageWraith 10 месяцев назад
insteadof using 4x40a why cant you use 2x80a brakers
@skalnican
@skalnican 10 месяцев назад
I mean the math adds up...definitely a question for a qualified electrician which I am certainly not. If you get an answer feel free to post here so others can see the answer. Thanks!
@johnshield7157
@johnshield7157 2 месяца назад
I too am not an electrician, but I would be concerned using 2 x 80 amp breakers, the load for each heating element is structured to shut down if it goes over 40 amps, if you put in 80 amp breakers there will be no fault on any single element till 80 amps is obtained….i would be skeptical…just my opinion.
@user-ps9dg6tq9s
@user-ps9dg6tq9s Год назад
I have the same tankless water heater and recently it stopped heating up water. Do you know how I can fix it. We have replaced the flow meter still don’t work
@skalnican
@skalnican 11 месяцев назад
I'm certainly no expert. The heating elements can fail over time. Maybe that's the issue?
@ericmendoza6238
@ericmendoza6238 Год назад
Can you provide a link to the valve set up you purchased from Amazon? Thank you!
@skalnican
@skalnican Год назад
Sure thing… a.co/d/9FFU6jH
@ronfrauenfelder5879
@ronfrauenfelder5879 Год назад
Thank you, I’m going to take your advice and order it Thru Amazon.
@hugomesenbring2291
@hugomesenbring2291 Год назад
So 300 Amps is recomended but would you feel okay installing it on 200?
@skalnican
@skalnican Год назад
I read about another person on a DIY forum that installed one with 200 amp service and it was fine. It depends on how much stuff you have drawing power. It has the potential to draw 160 amps. Looking back I probably could’ve sized down to the 27kw model and been fine. That model uses three 40amp circuits instead of four. It says you can use it with 200amp service. We have a 3 full bath home with 3 people for context. Please note I’m not an electrician. If I was in your shoes I’d look at the 27kw model. Good luck!
@donhuffer5167
@donhuffer5167 Год назад
200amps is more than enough.
@donhuffer5167
@donhuffer5167 Год назад
Is that method to code? Running romex into the flex? I’m installing a 27 but it must be to the building code.
@skalnican
@skalnican Год назад
I’m honestly not 100% as I’m just a homeowner and not an electrician. I found conflicting info out there.
@u2ooberboober
@u2ooberboober Год назад
I’d strip back the outer pull sheathing and just run the wires individually in the flex. Install a junction box at the top where the romex will enter and the other end of the flex goes to same jbox.
@donhuffer5167
@donhuffer5167 Год назад
@@u2ooberboober I ran the wire from the panel thru the wall and exited the drywall thru an LB. The LB connected to the water heater. All per code with my inspectors approval.
@u2ooberboober
@u2ooberboober Год назад
@@donhuffer5167 I always wonder about conduit fill for the size of conductors to prevent heating. I guess the lb can be considered a nipple with no limitations.
@plumbcartel6779
@plumbcartel6779 Год назад
Oh god sharkbites and flex lines lol. At least it's exposed i guess.
@mrlnslmt
@mrlnslmt Год назад
36kW is too much for residential homes. Only good if you have at least 300Amp house.
@skalnican
@skalnican 11 месяцев назад
We have 300A service. In hindsight I could've sized down. Too late now.
Далее
Tankless Water Heater Install | Existing Home
21:50
Просмотров 516 тыс.
Х.евая доставка 😂
00:23
Просмотров 640 тыс.
Rheem RETEX-18 The Review You Want To See
11:25
Просмотров 110 тыс.
3 Things They Don’t Tell You About Tankless
5:56
Просмотров 2,6 млн
Proper venting of a Rinnai RUR series unit.
19:20
Просмотров 36 тыс.