RSLinx OPC Data Testing Using OPC Test Client | RSLinx DDE/OPC Topics Tips & Tricks 

Shane Welcher
Подписаться 28 тыс.
Просмотров 18 тыс.
50% 1

Опубликовано:

 

18 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 31   
@ShaneWelcher
@ShaneWelcher 3 года назад
Subscribe: mmini.me/Subscribe-4-Updates
@PardeepLabVIEW
@PardeepLabVIEW 3 года назад
❣️
@kathirangamuthu3574
@kathirangamuthu3574 6 месяцев назад
Thank you very much for sharing knowledge
@ShaneWelcher
@ShaneWelcher 6 месяцев назад
Glad to help
@sergheicaraman545
@sergheicaraman545 4 месяца назад
Thank you but I have a question: What happens if you get your PLC offline? RSlinx goes always on as well as the Factory? It seems they are both running from cache. Is there a way that the Factory flags up the loss of connection once the PLS goes offline?
@ShaneWelcher
@ShaneWelcher 4 месяца назад
Once the PLC fails to connect to the OPC then it should show bad connection or bad data instead of real world values
@PardeepLabVIEW
@PardeepLabVIEW 3 года назад
great dear sir
@ShaneWelcher
@ShaneWelcher 3 года назад
Keep watching
@VaibhavShankar-xo1kn
@VaibhavShankar-xo1kn 5 месяцев назад
Great video! Thank you! Do you know how to run the RSLinx Classic OPC as automatic service to run 24/7?
@ShaneWelcher
@ShaneWelcher 5 месяцев назад
If you have a connection that request then I automatically connects. Meaning, an OPC topic through RSLinx running as a service
@VaibhavShankar-xo1kn
@VaibhavShankar-xo1kn 5 месяцев назад
@@ShaneWelcher Ahh I see. Thank you. I am also working on a client application that needs to pull data from the RSLinx Classic OPC. How do we setup a subscription / publication service between the two? For example: 1. Part Serial scans by PLC 2. Print Command by PLC These reflect in RSLinx OPC. Wondering how to push that to the client app
@ShaneWelcher
@ShaneWelcher 5 месяцев назад
@@VaibhavShankar-xo1kn This is not something that can be easily answered over text because it depends on what OPC connection you are using. Refer to Rockwell's knowledgebase
@Sumee21051987
@Sumee21051987 24 дня назад
I am using RSLinx Classic Gateway. Is it possible to use DDE/Topic configuration with that? I am trying to run Machine Simulator with RSLinx Classic Gateway. Is it possible with OPC Test Client? Thank you in advance.
@ShaneWelcher
@ShaneWelcher 24 дня назад
@@Sumee21051987 depends on the operating system you are using. Certain windows 10 and windows 11 OS systems have security that blocks DDE
@arjunjayswal6347
@arjunjayswal6347 Год назад
Thank you
@spidergt80
@spidergt80 2 года назад
Can you use RSlinx lite to connect to Machine simulator (easyPLC) … or it must be a non “lite” edition?
@ShaneWelcher
@ShaneWelcher 2 года назад
You need to use RSLinx Classic or Pro so you can use OPC topics. Lite doesn't offer OPC topics
@seulcruz4918
@seulcruz4918 Год назад
What version is your Studio 5000?
@ShaneWelcher
@ShaneWelcher Год назад
Studio 5000 V32
@shawnspencer8766
@shawnspencer8766 2 года назад
When you purchase software, does it come with rslinx classic? Or do you have to purchase that seperate
@ShaneWelcher
@ShaneWelcher 2 года назад
When you purchase Studio 5000 or RSlogix 5000 then yes.
@shawnspencer8766
@shawnspencer8766 2 года назад
@@ShaneWelcher ahh, I got the 500 micro. Probably still comes with classic lite then I'm sure. Thanks for the reply 👍🏻
@ShaneWelcher
@ShaneWelcher 2 года назад
@@shawnspencer8766 yes, the micro lite comes with RSlinx classic lite. RSlinx lite doesn't allow OPC usages
@shawnspencer8766
@shawnspencer8766 2 года назад
@@ShaneWelcher actually I bought micro starter. Any luck with that one?
@ShaneWelcher
@ShaneWelcher 2 года назад
@@shawnspencer8766 if you have RSlinx lite then no OPC use. You need the pro version of RSlinx
@nbw22
@nbw22 3 года назад
Thanks for the enlightenment. I have a question about my RSlogix.. I want to connect my Citect Scada 2018 to Rslogix5000 using RSLink Classic Gateway and I am using Rslogix Emulate 5000 as my PLC . Kindly enlighten me on the configure driver setting or if you have a tutorial would be highly appreciated. Thanks a million!
@ShaneWelcher
@ShaneWelcher 3 года назад
Have you tried OPC? Setting up a topic then adding the tags.
@nbw22
@nbw22 3 года назад
@@ShaneWelcher Thanks for your reply. Our OPC has been running quite well in the plant but I had not been involved setting it up during commissioning. So now I want to practice doing it with an emulator (RSlogix emulate 5000) with my rslinxclassic gateway to my citect scada. I'm confused which driver i will use when setting up drivers for opc in rslinx.. 😅. if i use ethernet, is the hostname my pc name? Also my rslinx keeps closing now if i click any drivers.. 🤔🙏
@ShaneWelcher
@ShaneWelcher 3 года назад
@@nbw22depends if you are running it as a service or application Check RSLinx control panel
@aprilmay5974
@aprilmay5974 Год назад
Hello Sir, I have RS Linx Classic Gateway, RS Logix 500 Pro, RS View32 for my AB Micrologix 1200, can I remote control this PLC using LabVIEW and its web publishing tool thru RS Linx OPC Server? Thank you very much
@ShaneWelcher
@ShaneWelcher Год назад
Seems possible, you should try it