🔸Guys Aaj ki Video ka Topic hai-
'' RTCC Panel/ AVR Relay Setting''
🔸You Can Easily understand about the -
'' Automatic Voltage Regulating Relay Settings ''
🔸If you have any query-
you can ask by the Comment
🔸Guys Please
▪️Like 👍
▪️Share 📲
▪️Comment ✍️
▪️Subscribe 👆This Channel
▪️Also Press 🔔🔔Bell icon
🔸My Channel Link
/ @technicalwork1
#RTCC_Panel_Setting
#AVR_Relay_Setting
#Emco_AVR_EE301E_Relay_Setting
My Other Videos 👇👇
👉How to Make Water Immersion Heater/ Homemade Water Heater
• How to Make Water Imme...
👉How to Repair water Immersion Rod
• How to Repair Immersio...
👉 How to Repair Table Fan
• How to Repair Table Fa...
👉 Table fan 3-Wire Motor Connection
• Table Fan 3-Wire Motor...
👉 Table fan 3 speed Switch Connection
• 3 Speed Table Fan Conn...
👉How to Make Extension Board at Home / Homemade Extension Board
• Extension Board || Hom...
👉Series Testing Lamp Connection
• Series Test Lamp kaise...
👉Table Fan 3 Wire Motor Connection
• Table Fan 3-Wire Motor...
👉How to Check Single Phase motor Winding
• How to Check Motor Win...
👉Switch Socket Board Connection
• Switch Socket Board Co...
👉How to Check Common, Running and starting Wire from 3 Wire Ceiling fan
• How to Check Fan Commo...
👉 How to Check Ceiling fan Winding
• How to Check Ceiling f...
👉How to do 2 Switch Cooler Connection
• How to do Cooler Conne...
👉How to Make phone Charging Stand/ Home made
• How to Make Mobile wal...
👉 How to Make Table Lamp at Home/Emergency Light/Homemade Led Lamp
• How to Make Table Lamp...
👉Water Tank Alarm Bell Connection
• Water Tank Alarm Bell ...
👉How to Increase Speed of Ceiling Fan & Fan Connection
• How to Increase Speed ...
👉How to Repair washing machine Rotating Component
• Washing machine Part R...
👉Transformer On Load Tap Changer Operation
• On Load Tap Changer Op...
👉Bed Switch Connection
• Bad Switch Connection ...
👉How to Use Clamp Meter Fully practically
• How to Use Clamp Meter...
👉3 pin plug proper Connection • 3 Pin plug Connection ...

Авто/Мото

Опубликовано:

 

10 янв 2022

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 76   
@RohitSharma-ye7wn
@RohitSharma-ye7wn 2 года назад
Bhut achhi video bnai hai iski bhut need thi aaj thank u ❤❤❤ so much bhai
@altafanwar2826
@altafanwar2826 Год назад
Thanku so much😁😁 sir ji really good work 🙌🙌🙌
@Mithilesh658
@Mithilesh658 Год назад
very nice information sir thank you so much🙏🙏💕💕
@sandeepskreal
@sandeepskreal 2 года назад
Thank you so much sir.,. 🙏. Share this I'm so happy
@electricalvisions2point0
@electricalvisions2point0 Год назад
Good information bro
@Basicsikho-fx5pr
@Basicsikho-fx5pr Месяц назад
Very nice
@TechnicalWork1
@TechnicalWork1 Месяц назад
❤️🙏
@Palelectrical
@Palelectrical 5 месяцев назад
Good job
@TechnicalWork1
@TechnicalWork1 5 месяцев назад
😊🙏
@rkprasadbhookya1878
@rkprasadbhookya1878 2 года назад
nice
@sksingh2178
@sksingh2178 Год назад
good
@Ashokkumar-dk3vm
@Ashokkumar-dk3vm 10 месяцев назад
What is the auxiliary supply for AVR to switch on? From Where it is provided?
@pareshkanjariya9709
@pareshkanjariya9709 Год назад
Please explain the connection between AVR and tape Changer indication
@TechnicalWork1
@TechnicalWork1 Год назад
whenever it takes command to change voltage up or down by AVR, the Indicator light will be Automatically ON this time
@vlogwithss4275
@vlogwithss4275 Год назад
Can you please share IC numbers in EMCO E E 301E AVR ?
@TechnicalWork1
@TechnicalWork1 Год назад
Main Pcb There are 3 Regulator IC Number is - 7812, 7912, 7805... Used for Regulates +12 V, - 12 V, +5 V Dc Supply
@Tureindian
@Tureindian 6 месяцев назад
CT or tap changer connect AVR me hota hai sir g
@amarjeetsingh5398
@amarjeetsingh5398 2 года назад
Sir please mujhe samjahe ki 11 kv me kitni voltage honi chaiye
@bhanulamichhane4734
@bhanulamichhane4734 2 года назад
how to calculate that value 104 mathematically
@shivanandprajapati2222
@shivanandprajapati2222 2 года назад
What is normal and test switch in tap position indicator please tell me
@TechnicalWork1
@TechnicalWork1 2 года назад
Normal Position indicates the Actual Tap position.. And the Test position is For the display test.. It indicates the all 7 LED's Block is Glowing or not Glowing.. For Example - it Always show 88 on Display.. 8 Is Consist with 7 LED blocks..
@pareshkanjariya9709
@pareshkanjariya9709 Год назад
Dear sir RR common and LR ke bich me continue voltage dekhata he ki only tape change hota he tabhi dikhata he
@TechnicalWork1
@TechnicalWork1 Год назад
Wo PT ka Voltage hota hai jo Regularly show karta hai..
@harpreetsingh-hp9cm
@harpreetsingh-hp9cm Год назад
Bhai fast time karna plz Puri Tara batoo
@TechnicalWork1
@TechnicalWork1 Год назад
Puri tarah hi bataya hai.. 😂😂 Kya problem Aa rhi h Rtcc panel me
@sampadbarik8802
@sampadbarik8802 Год назад
Pt voltage 11kv side pt ka hein ya 132kv side pt ka hein
@TechnicalWork1
@TechnicalWork1 Год назад
11 kv ka hai
@sampadbarik8802
@sampadbarik8802 Год назад
@@TechnicalWork1 thanks
@nandkumarsangare1095
@nandkumarsangare1095 11 месяцев назад
Setting ka selector kidhar rakhana chahiye R set L set or PT
@TechnicalWork1
@TechnicalWork1 11 месяцев назад
PT pr rakhna hai.
@amarjeetsingh5398
@amarjeetsingh5398 2 года назад
And how these values calculate on calculator
@akshaybaby3708
@akshaybaby3708 11 месяцев назад
Pt voltage × 3.9
@TechnicalWork1
@TechnicalWork1 11 месяцев назад
@akshaybaby3708 Thanks bhai.
@ArvindKumar-si1xq
@ArvindKumar-si1xq 2 года назад
Rtcc pannel control wing kaise kare
@TechnicalWork1
@TechnicalWork1 2 года назад
Control Wiring ka to mujhe bhi pta nhi bhai.
@manojmulajkar5114
@manojmulajkar5114 Год назад
Mera Transformers muze All ready Step Down kar kie De Raha Hai To Muze Rtcc panel lagnae Kya jarurut Hai Esakie liye bhi Kuch bata do Sir
@TechnicalWork1
@TechnicalWork1 Год назад
Jaha voltage Fluctuate jyada hota hai. Waha jyada jarurat padti hai RTCC panel ki..
@shivaparmar7666
@shivaparmar7666 Год назад
If tap on 1 and voltage is 452 and ACB trip and Voltage on VCB is 11.92KV and transformer range maximum upto 11.5KV then what is the solution to control tha voltage in LT panel
@TechnicalWork1
@TechnicalWork1 Год назад
You have need to Contact at Substation for the voltage.. They Will Rectify these issue
@santoshpandit6242
@santoshpandit6242 4 месяца назад
UV or R LED light ah raha hai kiya kare..
@TechnicalWork1
@TechnicalWork1 4 месяца назад
Pt voltage kitni Aa rhi hai.. Aur problem kya Aa rhi hai
@parmodyadav9966
@parmodyadav9966 11 месяцев назад
11 Kv pr R and L ki value Kya hogi
@TechnicalWork1
@TechnicalWork1 11 месяцев назад
R Set ki Value ko 104 pr L Set ki Value 109 pr krdo.
@nageshyadav1062
@nageshyadav1062 Год назад
How your set a values in AVR standards is 110. How we fix R set & L set settings
@TechnicalWork1
@TechnicalWork1 Год назад
110 is PT Voltage.. It is depend upon the HT Voltage.. I have also Explained in this video for R set and L Set Setting..
@bapanpandit7714
@bapanpandit7714 3 месяца назад
Sar ji OLTC ka all parts kaha per milta hai courier mein
@TechnicalWork1
@TechnicalWork1 3 месяца назад
Iska idea to mujhe bhi nhi hai. Aap Google pr Search kr lo 1 baar..
@nagendrasingh2522
@nagendrasingh2522 9 месяцев назад
Mere rtcc panel 1 no se 17 our 17 no se 1 no par bar bar up down ho to kya problem ho sakti hai
@TechnicalWork1
@TechnicalWork1 9 месяцев назад
OLTC Me Step up and down k 2 contactor hote hai unhe Check kro kahi hold to nhi ho rakhe hai jiski wajah se Baar baar command le rha hai.
@nagendrasingh2522
@nagendrasingh2522 9 месяцев назад
Sir check Kiya hai contactor chipka nahi hai but sir manual our auto dono me command Dene par ek bar command Dene par lagatar tep change ho Raha hai.
@TechnicalWork1
@TechnicalWork1 9 месяцев назад
@nagendrasingh2522 Fir to AVR Relay me hi koi problem hai jo baar baar Command de raha hai.. Bina Panel ko dekhe pta bhi nhi chal payega, Fault kya hai
@thakordinesh5016
@thakordinesh5016 Год назад
Calculation samajao transformer ratio ke hisab se
@ParveenKumar-uj5oe
@ParveenKumar-uj5oe 2 года назад
Pt means bro
@TechnicalWork1
@TechnicalWork1 2 года назад
Potential Transformer..
@TechnicalWork1
@TechnicalWork1 2 года назад
It is use to measure high Voltage
@user-nr3fp1cd1j
@user-nr3fp1cd1j 10 месяцев назад
Mere meter me 00 hi voltage 419 dikha Raha hai
@TechnicalWork1
@TechnicalWork1 10 месяцев назад
R Set ya L set pr koi value show ho rhi h kya?
@abinashpradhan5339
@abinashpradhan5339 Год назад
How to set Timming setting
@TechnicalWork1
@TechnicalWork1 Год назад
AVR relay has time-delay option. By turning his knob, we can change the Time
@TechnicalWork1
@TechnicalWork1 Год назад
60 Sec is best for Tap changing Normal Operation..
@mindtricks8769
@mindtricks8769 2 года назад
Please sir show AVR relay connection
@TechnicalWork1
@TechnicalWork1 2 года назад
Yeah Sure. Aap mujhe Instagram pr msg kariye.. I will show you the AVR Relay Connection..
@TechnicalWork1
@TechnicalWork1 2 года назад
About me Instagram ka Link h..
@harharmahadevsupar8088
@harharmahadevsupar8088 11 месяцев назад
bhai samjha me kuch nahi aaya kese samjhta h sab dimag se upar gya
@TechnicalWork1
@TechnicalWork1 11 месяцев назад
Rtcc panel me kya problem Aa rhi h
@manojkumarpandey3472
@manojkumarpandey3472 10 месяцев назад
Auto me not working rtcc
@TechnicalWork1
@TechnicalWork1 10 месяцев назад
AVR relay me R Set aur L Set ki Setting kitne pr hai.
@scsrikumar
@scsrikumar Год назад
Vai itna jaldi kiyu?
@TechnicalWork1
@TechnicalWork1 Год назад
Kya.. Mai smajha nhi
@VijayKumar-jo1yd
@VijayKumar-jo1yd Год назад
Step m Kam nahin kar raha hai
@TechnicalWork1
@TechnicalWork1 Год назад
RTCC Panel me Auto Manual ka Switch hoga.. Manual me krke, Lower waale button ko press krke check karo
@krishnaelectrikworksmotarr5131
Time kese set hoga
@TechnicalWork1
@TechnicalWork1 Год назад
Relay me jaha Time Delay Likha use ghumane se Time adjust hoga.. Jitne Second pr Apko karna hai kr sakte hai.
@naseemshaikh2951
@naseemshaikh2951 2 года назад
PT voltage 0000 show ho raha hai to kya kare
@TechnicalWork1
@TechnicalWork1 2 года назад
AVR Relay k back side me PT fuse lage hote hai.. Aap 1 baar PT fuse check kr lo.. Usi ki wajah se 0000 show hota hai..