In this video I continue talking you through the AM2 assessment using the NET pre-assessment manual, available off of the NET website.
I discuss the types of fault, apply them to a ring or a radial circuit, and discuss the reasoning behind the location description, rectification method and the need to test and prove the repair works.
I also talk you through a simple heating and hot water installation using a flow chart, which will not only help you diagnose where the faults might be, but may also help you get your head around how they are connected.
I’m not 100% happy with this video, as I think I could have done it better, so I’m going to tweak it slightly later on.
But for now, this will get you started.

Опубликовано:

 

26 дек 2020

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 128   
@EW00AW04
@EW00AW04 2 месяца назад
If you don’t want to buy the XS training videos for the whole AM2 prep course then this guy is your best best bet
@Pure_electrical_training
@Pure_electrical_training Месяц назад
Awesome, thank you
@paulkabanda4360
@paulkabanda4360 8 месяцев назад
I don't ever comment on RU-vid videos but I had to send out a massive thank you to Adrian. I failed my fault finding the first time. I found this channel and it has been so helpful. I passed it on second attempt. No nerves at all going it as your explanation of how to fault find was on point. Thanks again
@Pure_electrical_training
@Pure_electrical_training 8 месяцев назад
Thank you so much for your positive feedback, and congratulations on passing your AM2 🤗👊
@TheDecagon247
@TheDecagon247 3 года назад
love the whole series of AM2 videos your doing massive help :)
@Pure_electrical_training
@Pure_electrical_training 3 года назад
You are more than welcome 🤝
@MitchellAlastair
@MitchellAlastair 15 дней назад
Brilliant video, very helpful! Thank you Adrian!
@craiglewis3726
@craiglewis3726 3 года назад
Great informative video Adrian. You explain things very well! Thank you so much for taking the time to make these videos. Keep up the good work mate 👍🏻
@Pure_electrical_training
@Pure_electrical_training 3 года назад
You are more than welcome 🤗🤝
@jameslong966
@jameslong966 3 года назад
Sitting my Am2 in afew weeks, Great video! 👍
@Pure_electrical_training
@Pure_electrical_training 3 года назад
Good luck 🙌
@aaronsmart7896
@aaronsmart7896 8 месяцев назад
Awesome content! AM2S next week, glad I found these videos. Thank you!
@Pure_electrical_training
@Pure_electrical_training 8 месяцев назад
You are very welcome 👊
@drsamuelbeckett2998
@drsamuelbeckett2998 2 года назад
Thankyou for this video Adrian it was an awesome video and helped massively with me passing my AM2.
@Pure_electrical_training
@Pure_electrical_training 2 года назад
You are more than welcome 🤝
@morgandevereux2028
@morgandevereux2028 6 месяцев назад
Very good video. Thank you very much for taking the time to run through those important points!
@Pure_electrical_training
@Pure_electrical_training 6 месяцев назад
You are very welcome 🤗
@Shukovsky
@Shukovsky 3 года назад
This is the most informative video I've seen on electrics, its the night before my inspection and testing/fault finding am2s day, so thanks mate
@Pure_electrical_training
@Pure_electrical_training 3 года назад
You are more than welcome, spread the word and hopefully I can help others in the same situation
@Shukovsky
@Shukovsky 3 года назад
@@Pure_electrical_training i will mate count on it 👍🏻
@trevorhall9377
@trevorhall9377 3 года назад
Thanks for your video found it so helpful I failed twice watched your video put me at ease helped me stop getting confused under pressure thanks again Easy to remember on the day under pressure many thanks
@Pure_electrical_training
@Pure_electrical_training 3 года назад
You are more than welcome Trevor 🤝
@caffeine9317
@caffeine9317 2 года назад
Passed the Am2s, had to resit fault finding - your videos helped a ton, thanks!
@Pure_electrical_training
@Pure_electrical_training 2 года назад
Congratulations 👏
@Alexander_sparky
@Alexander_sparky Год назад
I’m Rewiring my fault finding soon stressing out 😂😂
@caffeine9317
@caffeine9317 Год назад
@@Alexander_sparky you got this, just remember you're allowed to use your book if you're stuck but you should be sweet :-)
@HhhGgg-iy1mk
@HhhGgg-iy1mk 2 года назад
Very good roundup. Thank you mate, top job
@Pure_electrical_training
@Pure_electrical_training 2 года назад
You are welcome 🙏
@Iceman030591
@Iceman030591 2 года назад
Smashed my fault finding re-sit, your video was a lot of help thanks mate, keep up the good work.
@Pure_electrical_training
@Pure_electrical_training 2 года назад
Thank you and well done 👏
@dasbeatz4512
@dasbeatz4512 Год назад
@@Pure_electrical_training Are you allowed to do a insulation resistance test on the fault finding?
@TheFella172
@TheFella172 Год назад
Another fantastic video, this will help with setting yourself up for the AM2 exam and applying the knowledge you should already have. I am currently watching this video series through first, and will then watch the series again from the begininning with paperwork and reference textbooks as advised. My only other comment is the books have now changed since these videos were recorded to the BS7671 2018:2, (brown book/brown flash), so the page numbers are different to what is said in the video. Top job Adrian! Thank you. (Brent).
@Pure_electrical_training
@Pure_electrical_training Год назад
Thank you for the great feedback Brent 🤗 I should have thought about the page numbers bring different in future BS7671 editions 🤦‍♂️
@addygbwfc
@addygbwfc 3 года назад
Great video nice one, passed all AM2 apart from fault finding, just re sitting in a couple week and found this has eased some pressure🤝
@Pure_electrical_training
@Pure_electrical_training 3 года назад
You are more than welcome 🤝
@zilvinas05
@zilvinas05 2 года назад
Super informative and helpful videos, as my am2 exam is coming very soon. Probably best preparation you can find on youtube! Highly recommended to all learners and for people who are working already, to be sure they doing it in right way. All the best of luck Adrian!
@Pure_electrical_training
@Pure_electrical_training 2 года назад
Good luck 🤞
@JordieeArnold
@JordieeArnold 9 месяцев назад
How did you get on?
@ryanjholden
@ryanjholden 2 месяца назад
Never comment on videos but this is top tier 👍🏻 cheers
@Pure_electrical_training
@Pure_electrical_training 2 месяца назад
Thank you for taking the time 👌
@lokiop345
@lokiop345 3 года назад
Great vid mate... very hard subject.. very very hard subject.. got my fault finding tomorrow and will almost certainly fail. Difficult subject well explained... but it doesn't change the difficulties!!! Damn it ! 😪
@Jonjo999
@Jonjo999 3 месяца назад
Passed everything on my AM2S first time and only failed just my fault finding section by 2 bloody marks, right now is sunday late evening, got my resit tomorrow (monday), just watching your video to recap has helped me alot. Everyone wish me luck! Thanks Adrian!
@tayloryoung3130
@tayloryoung3130 3 месяца назад
How do you know u failed by 2 marks ?
@Pure_electrical_training
@Pure_electrical_training 3 месяца назад
Good luck 🙌
@Jonjo999
@Jonjo999 3 месяца назад
@@tayloryoung3130 got a call from the assessment centre and they told me
@Jonjo999
@Jonjo999 3 месяца назад
@@Pure_electrical_training i passed mate, thank you soo much 🙏🏼
@Jonjo999
@Jonjo999 3 месяца назад
@@tayloryoung3130 i got a call from the centre where i did my exam
@gyasikrasineb4808
@gyasikrasineb4808 Год назад
Excellent presentation so much to take in.
@Pure_electrical_training
@Pure_electrical_training Год назад
It is a good idea to break it down into smaller chunks 👍
@macoveivasile75
@macoveivasile75 Год назад
Thank you for your videos, help me a lot !!!
@Pure_electrical_training
@Pure_electrical_training Год назад
You are more than welcome 🤗
@Sergey3023
@Sergey3023 3 года назад
Great video! Thank you for sharing 👍🏻
@Pure_electrical_training
@Pure_electrical_training 3 года назад
You are welcome 🙏
@mrsid4208
@mrsid4208 Год назад
This video helped me so much in my AM2E 🙏🏼 and I have Smashed it 😍.
@mrsid4208
@mrsid4208 Год назад
Thank you Admin ❤
@Pure_electrical_training
@Pure_electrical_training Год назад
You are more than welcome 🙏
@martinogrady6268
@martinogrady6268 3 года назад
I’m actually in the middle of my am2s now. Practical was yesterday. Fault find today and inspection, testing an online exam tomorrow. Thanks for the videos! Great help!
@Pure_electrical_training
@Pure_electrical_training 3 года назад
You are welcome 🤝
@krazylad84
@krazylad84 3 года назад
Cheers Adrian, very helpful video.
@Pure_electrical_training
@Pure_electrical_training 3 года назад
You’re more than welcome 🤝
@Pure_electrical_training
@Pure_electrical_training 3 года назад
You’re more than welcome 🤝
@davidlewis4162
@davidlewis4162 Год назад
This is a great video, Thanks
@Pure_electrical_training
@Pure_electrical_training Год назад
You are more than welcome 🙏
@sbmorris2k6
@sbmorris2k6 3 года назад
I was told simple things like using the wrong words in some test centres can fail you so, instead of cross connection it has to be cross polarity and things like that. Good video though really helpful got my am2 coming up 👌
@Pure_electrical_training
@Pure_electrical_training 3 года назад
Good luck 🤞
@ef7480
@ef7480 2 года назад
Brilliant.....
@sunshine3187
@sunshine3187 Год назад
This is hands down the best video ive seen for the AM2. I have mine next week. I have two questions dude. 1, can you open the accessories on the am2 fault finding section? 2, can you use the long lead test for polarity on ring final? Cheers.
@Pure_electrical_training
@Pure_electrical_training Год назад
Thank you 🤗 You can open the accessories to disconnect cables, but the cabling will look correct as the faults are introduced behind the scenes, which can throw a lot of people off. You could use the long lead method to test conductors through the circuit if you wanted too. The installation is so small that you wouldn’t actually need a long lead, the normal leads are long enough
@nickiwell1159
@nickiwell1159 2 года назад
Very helpful
@Pure_electrical_training
@Pure_electrical_training 2 года назад
Thank you
@bernardcharlesworth9860
@bernardcharlesworth9860 Год назад
Nice chap
@Pure_electrical_training
@Pure_electrical_training Год назад
Thank you 🙏
@pinaconorth007
@pinaconorth007 Год назад
Thank you 😊
@Pure_electrical_training
@Pure_electrical_training Год назад
You are welcome 👌
@jamiemaxted2371
@jamiemaxted2371 2 года назад
Your video is so good and im currently revising for my AM2 fault finding that i need to resit at the end of the month. Personally this has been very good for my learning of fault finding especially with the boiler breakdown and also intermediate switching and ring finals, my only thing that i tend to struggle with at the moment is going with what test to start with ( IR or Continuity) would you tend to go straight for the IR test if you was for example getting an MCB tripping? with an MCB tripping it could also be a misconnection as well as a short circuit, im interested to know what route you would take first in regards to what test you would do as i struggle with this if im honest and want to obviously find the fault in good time to enable me to have more time on those more difficult faults, thank you for your video very helpful. Jamie
@Pure_electrical_training
@Pure_electrical_training 2 года назад
You are more than welcome Jamie 🙏 They aren’t trying to trip you up, so keep it simple. If the circuit breaker is operating, then exactly as you say, you have a short circuit fault, so straight to IR tests 👍
@jamiemaxted2371
@jamiemaxted2371 2 года назад
@@Pure_electrical_training thank you so much for getting back to me so quick. keep up the good work
@Big-T-
@Big-T- Год назад
Got my reset for section E, failed it by 2 marks, gonna smash it today, cheers.
@Pure_electrical_training
@Pure_electrical_training Год назад
You are more than welcome and good luck 👊
@ek6868
@ek6868 3 года назад
Tanx for the upload i bet it's not that straightforward and easy in the real world,especially if your going into smelly and dirty customers house's.
@Pure_electrical_training
@Pure_electrical_training 3 года назад
A few years experience and you get your sparky sense
@rallyjaymuhindo6399
@rallyjaymuhindo6399 3 года назад
one thing to consider is that the same board has been used for fault rectification several times by several people. If I find a fault that was left by a previous person but its not the fault they expected me to find in the exam, Do I get marked down or do I still get a mark? Because people are racing against the clock during the exam and they may leave some points loose or misconnected when they put staff back together and move onto the next fault. Some people have across this.
@Pure_electrical_training
@Pure_electrical_training 3 года назад
It’s a fair comment and one I don’t know they answer for 😁
@faysalmehrban2161
@faysalmehrban2161 8 месяцев назад
good vid 10/10
@Pure_electrical_training
@Pure_electrical_training 8 месяцев назад
Thank you
@rhysmorgan3057
@rhysmorgan3057 2 года назад
Wicked video👍🏻 not sure if you know but you get bonding faults and D.O.L motor faults too just wondering if you can cover these aswell. Cheers
@Pure_electrical_training
@Pure_electrical_training 2 года назад
Thank you 🙏
@mpbuilder
@mpbuilder Год назад
Lovely
@Pure_electrical_training
@Pure_electrical_training Год назад
Thank you 👍
@jamesjackson2998
@jamesjackson2998 9 месяцев назад
Got my AM2s coming up soon. Just a quick question….. I was told on the pre-assessment that we would have to fault find on a piece of CAT-5. No problems there, but….there was no mention of testing the continuity of the CAT-5 during inspection and testing. As we are testing our own installation, and CAT5 being part of that installation, would the CAT-5 circuit need to be tested during the continuity stage of inspection and testing?
@Pure_electrical_training
@Pure_electrical_training 9 месяцев назад
That is a great question and I would say absolutely. Otherwise, how would you prove this was working and it might cause you to fail when they strip your install down.
@harrycharters9607
@harrycharters9607 5 месяцев назад
Great video, Would an open circuit on earthing conductor be classed as earth fault or open circuit ?
@Pure_electrical_training
@Pure_electrical_training 5 месяцев назад
Open circuit
@grahamhamlin674
@grahamhamlin674 Год назад
Great video , I’ve failed my fault finding twice now, out on site I can do it no problem but not on am2 , I can’t get my head around the heating fault they do it says programmer calls for heat but doesn’t work I messed it up both times , how would I find it would I just start with basic testing
@Pure_electrical_training
@Pure_electrical_training Год назад
Try this and let me know how you get on Boiler wiring made easy ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-rAYc64MsUYI.html
@salty8627
@salty8627 4 месяца назад
When you spoke about the mis conection with the continuity tester, would it pick up short between L-N too? Or does it just beep on continuity of conductos? Meaning if i had a fault and i thought it was a short, but i use the tester and it beeps on L/N then the short is now ruled out and now it is a mis connection? Hope this makes sense!
@Pure_electrical_training
@Pure_electrical_training 3 месяца назад
If you use a continuity tester between line and neutral, you may pick up the resistance of any loads connected in the system, a low ohm resistance tester will give you more feedback due to the readings, rather than just a beep that could mean anything.
@gbelectricks
@gbelectricks 3 года назад
I sat my am2 quite some time ago!!! Has the wording been changed from reverse polarity to mis-connection? Great video btw👍
@Pure_electrical_training
@Pure_electrical_training 3 года назад
I’m led to believe so, it’s the wording they use on their pre-assessment paperwork
@adamnazihmurray8874
@adamnazihmurray8874 2 года назад
I had my am2 last Sunday and I have been out of the tools for a long time due to personal reasons . I have six month to complete the NVQ and the Am2 . I have not received my results yet but I really struggled and I didnt complete two sections of the installations due to some mistakes that I made. I didnt complete the fault finding because I got stuck on a fault and I took too long on it. I would like to ask you when your testing for a fault and you get a reading how do you know which fault it is ? Sorry it may sound like a stupid question. If you get no reading between a conductor than I take it s its an open circuit but what about the other faults ? is there anyway you can practice fault finding ?
@Pure_electrical_training
@Pure_electrical_training 2 года назад
Why do you only have 6 months to complete the NVQ and AM2? Fault finding and testing are intrinsically linked, when you are testing R1+R2 and R1+RN you are checking for continuity and proving polarity. When you are testing insulation resistance, you are testing between line and neutral for short circuits and live to earth for earth faults. You do that before you put a circuit into service and that is fault finding.
@adamnazihmurray8874
@adamnazihmurray8874 2 года назад
​@@Pure_electrical_training well they are changing the qualification experience interest do you know anyone who failed the whole modules on the first attempt ?
@adamnazihmurray8874
@adamnazihmurray8874 2 года назад
They are changing the qualification criteria now, during the new year you will need at least five years experience, 18 edition and the initial verification qualification,
@ryanvesey8645
@ryanvesey8645 Год назад
Hey, would a cross connection give you the same reading on a IR test as a short circuit ? Eg cross polarity live and neutral ? Thank you.
@Pure_electrical_training
@Pure_electrical_training Год назад
Quite possibly because anytime line and neutral are connected together with a resistance of negligible impedance, you get a dead short
@ryanvesey8645
@ryanvesey8645 Год назад
Thanks for the reply , what is the best approach to determine if it’s a dead short or a cross connection ?
@Pure_electrical_training
@Pure_electrical_training Год назад
@@ryanvesey8645 In the assessments a dead short is obvious and will be the most likely choice for that type of fault. A misconnection is more likely to be something that isn't working correctly, like on the boiler or two-way switching. If there was a short circuit due to a misconnection, the fault would be proved by testing end-to-end and realising that the connections are incorrect. Most likely, can also be operated by a switch.
@MrAvosetta1
@MrAvosetta1 9 месяцев назад
When you say test the pump, how do you go about doing that would that not be classed as sensitive equipment?
@Pure_electrical_training
@Pure_electrical_training 9 месяцев назад
You can still pass 250V across line to Neutral, Line to Earth, Neutral to Earth. Or A low Ohm Resistance test to prove their is the correct resistance between line and neutral on the windings.
@paulgerrard2529
@paulgerrard2529 2 года назад
Hi do you have or know of a video helping with the professional discussion, just after a bit of advice.
@Pure_electrical_training
@Pure_electrical_training 2 года назад
Sure, what do you need advice on?
@jamiemaxted2371
@jamiemaxted2371 2 года назад
Hi Adrian, Sorry mate me again :) something has been bugging me ever since i've contacted you a day ago and i just wanted to see if you could clear it up for me as i know you'll have the simple answer. during the AM2 there was a number of fault finding situations where the circuit breaker had tripped, as we discussed in my previous post i would initially look at an Insulation Resistance test for a short circuit etc however IF the IR test was good and all cables were fine, would you then start to look at a potential misconnection/polarity fault? If were going by the 4 faults they have in the AM2 (Open Circuit, Short Circuit, High Resistance and Misconnection) am i right in saying the only other fault it could possibly be is a misconnection due to the MCB operating? Thank you Jamie
@Pure_electrical_training
@Pure_electrical_training 2 года назад
I don’t know the exact faults that NET have put into their assessment, but it is a possibility that you may have to check for a misconnection.
@michaelcostello6991
@michaelcostello6991 2 года назад
If a socket has wrong polarity L&N does it cause a problem if an appliance is plugged in ? Does anything trip etc . Would the customer have any issues ?
@Pure_electrical_training
@Pure_electrical_training 2 года назад
Most appliance can run in reverse polarity and you would never know. Where it makes a difference is with switching, isolation, over current and protective devices.
@michaelcostello6991
@michaelcostello6991 2 года назад
@@Pure_electrical_training Thanks. I knew about over current safety issues. The fact that most appliances run without issue and customer would not know is scary. Also having no isolation is scary. Great information.
@95555219
@95555219 Год назад
Will there be a fault that “light always on “in AM2?
@Pure_electrical_training
@Pure_electrical_training Год назад
It’s feasible as that is a real life scenario
@beatnik1989
@beatnik1989 3 года назад
Does anyone know if C&G 8202 is the first step to becoming an electrician? This is the only college course I can find that does part time.
@Pure_electrical_training
@Pure_electrical_training 3 года назад
The 8202 course has taken over from the 2365 course, and it is the first step on the self funded route
@beatnik1989
@beatnik1989 3 года назад
Thanks Adrian! That helps me a lot. It’s a minefield out there when looking to switch careers.
@wilfbrocklebank133
@wilfbrocklebank133 3 года назад
I have to sit this in the next few weeks, fail last time on rectification
@Pure_electrical_training
@Pure_electrical_training 3 года назад
Good luck 🤞
@saviofernandes8356
@saviofernandes8356 3 года назад
@@Pure_electrical_training Good video thank you
@wilfbrocklebank133
@wilfbrocklebank133 3 года назад
@@Pure_electrical_training with rectification is it as simple as describe where the fault is, tell them how to sort & what test after to prove its sorted ? Also the online exam got me last time any best way to hit this?
@wilfbrocklebank133
@wilfbrocklebank133 3 года назад
Thanks for the videos and replies too
@Pure_electrical_training
@Pure_electrical_training Год назад
@@wilfbrocklebank133yes
@drpantastic1969
@drpantastic1969 Год назад
499 i wanted to be like 500
Далее
Fault Finding Electrical Circuits - Electrician Life
24:57
The Mysteries of AM2 and AM2S - End Point Assessment
55:23
AM2 Assessments - DO's and DONT's ✍️
18:01
Просмотров 13 тыс.
AM2 pre assessment manual
15:20
Просмотров 18 тыс.
FAULT FINDING - RING CIRCUITS
15:38
Просмотров 41 тыс.