Siemens Analog Input Fault OR Error 

Qasim Maqbool
Подписаться 2,5 тыс.
Просмотров 28 тыс.
50% 1

Troubleshooting of Siemens Analog Input Module or Signal Module (SM) Fault OR Error. Alarms Related to Wire Break, Bad Signal, External Error, Over Range, Under range and out of range.
Analog input loop Tracing, Forward loop tracing, Backward loop Tracing.
Video Demonstrates the Analog input of Siemens Simatic PCS 7 (Process Control System).
Background Music: www.bensound.com (Free stock music site allowed to use in youtube)
My_Email: rana.qasim.maqbool@gmail.com

Опубликовано:

 

26 авг 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 38   
@portcranes97
@portcranes97 15 дней назад
Wow great video. for who need learn trouble shooting.
@mdnite2941
@mdnite2941 9 месяцев назад
Thank you we had this exact problem today! 👍
@abugaus9846
@abugaus9846 3 года назад
Thank you akhi for your clear presentation
@abdelmalikmedab1661
@abdelmalikmedab1661 3 года назад
Great Explanation, Thanks
@samisrour3129
@samisrour3129 3 года назад
Great tutorial.. many thx
@SajidAli-jr2hs
@SajidAli-jr2hs 4 года назад
Very welll explained, very basic troubleshooting method.
@shehneelawaraich3500
@shehneelawaraich3500 6 лет назад
Very helpful thanks 👍
@engrmdzohurulislam481
@engrmdzohurulislam481 3 года назад
Am from Bangladesh, thank you so much dear brother for your valuable solution of plc(anolog to digital) am want to more video for this related. thanks
@zakirsayed111
@zakirsayed111 2 года назад
good one !!. keep on making such videos..
@Mossskaterhans
@Mossskaterhans 6 лет назад
Very helpful !
@asimfasim4543
@asimfasim4543 6 лет назад
Maasha Allah excellent knoledge dharing vedeo
@QasimMaqbool
@QasimMaqbool 6 лет назад
Asim Fasim thanks friend
@TheGazanews
@TheGazanews 5 лет назад
well explained thanks
@m0vieGames
@m0vieGames 5 лет назад
Thanks Brother Syukron jazakallah khairan.
@majidkhoini6037
@majidkhoini6037 4 года назад
thank you my brother.who force the s300 analog
@raguraman1238
@raguraman1238 3 года назад
Very nice bro....
@Htnp192
@Htnp192 3 года назад
good
@jaywilliams9187
@jaywilliams9187 5 лет назад
Good video
@zachniroke9290
@zachniroke9290 4 года назад
thanks......Qasim
@jigargoswami6009
@jigargoswami6009 3 года назад
Thanks you sir
@divyangpatluwala7425
@divyangpatluwala7425 3 года назад
what is the use of jumper in between plus and minus terminal..
@boringracer4878
@boringracer4878 3 года назад
salama lekum my friend
@abhimanyumandal9303
@abhimanyumandal9303 5 лет назад
What is pos module used for in Siemens....
@muhammadfaizan9729
@muhammadfaizan9729 Месяц назад
How to deactivate a channel from group , if channel is spare? because its giving channel fault and SF alarm on AI module 6ES7336-4GE00-0AB0
@janmohammad3364
@janmohammad3364 2 года назад
Red laite on ho to kia msla hota
@ahmedkhan-cd5kl
@ahmedkhan-cd5kl 4 года назад
We have a AI card of Siemens 331-7kf02-OABO IT SHOWS SF FAULT BUT ITS HAS NO JUMPER IN AI MODULE SO WHAT SHOULD I DO
@QasimMaqbool
@QasimMaqbool 4 года назад
Dear sometimes this error appears due to open loop or wire break, over current more than 22mA or low loop current LEDs than 3.40 mA approx. If loop is OK then unscrew and lift up AI module and put back sometimes it hangs. Otherwise final replace the AI module.
@neamotullahjoy2268
@neamotullahjoy2268 5 лет назад
Thanks sir,i need your help about LS master K-120s .i am from Dhaka, Bangladesh.i need Ethernet cable for Ls K-120s .what can i do? sir
@QasimMaqbool
@QasimMaqbool 5 лет назад
Dear see below link regarding ur question may it will be useful. www.plctalk.net/qanda/showthread.php?t=113431
@javedkhannoorkhan8395
@javedkhannoorkhan8395 5 лет назад
thanks qasim bhai i am work with siemens simatic S7-200 (CPU-226) plz help on it
@QasimMaqbool
@QasimMaqbool 5 лет назад
What type of help u need?
@ariezackny329
@ariezackny329 5 лет назад
Assalaamualaikum wr. Wb Anyone can help me? I have problem with input signal using pcs7 . Plc S7-400 I have message from DCS PLC process C : error : input disturbed-792.5 PLC process G : error : input disturbed-679.4 PLC process QS: error:input distrubed-679.4 Operator input C: acknowlegment plc process control message I have 6 termocouople 4-20mA and 6 sensor at the same modul, chanel 1-6, and the signal sometime disturbed. And makes the machine interlocking. I also have tracking connection replace modul and the sensors, but problem is still dosnt solved. Any suggest for me like increase sampling time from 200ms to 500ms or something else. Thanks you
@kailashlenka6781
@kailashlenka6781 2 года назад
Sir launag iln hindi
@Balramkumar-id6hf
@Balramkumar-id6hf Год назад
Jai jai shree ram💕💕
@TheEngineerahmed6
@TheEngineerahmed6 6 лет назад
Very helpful thanks 👍
@QasimMaqbool
@QasimMaqbool 6 лет назад
engineer thanks for appreciation..
@jigargoswami6009
@jigargoswami6009 3 года назад
Thanks you sir
Далее
PLC Analog Inputs and Signals
8:55
Просмотров 705 тыс.
СМАЗАЛ ДВЕРЬ
00:31
Просмотров 250 тыс.
А ВЫ УМЕЕТЕ ПЛАВАТЬ?? #shorts
00:21
Просмотров 1,5 млн
Installing PLC Components and Hardware Connection
7:52
PLC Program for Thermocouple
13:46
Просмотров 14 тыс.
Troubleshooting a PLC Output
7:25
Просмотров 47 тыс.
Siemens Profibus and TIA Portal
49:16
Просмотров 92 тыс.