Тёмный

Siemens PLC Motion Control Training: Absolute Gearing and MAJOR DANGERS 

Jason Watts AE
Подписаться 2 тыс.
Просмотров 599
50% 1

This is an edited clip of the livestream below. There is a LOT more information in the full stream.
I discuss how to use MC_GearInPos on a Siemens 1500T processor and talk about some of the REAL DANGERS you can run into if you are not careful.
Original Livestream:
ru-vid.comspLxohsd...
0:00 Differences Between MC_GearInPos
4:40 Explanation of Parameters
8:05 Other Uses (Rotary Knife)
9:34 REAL DANGERS OF MC_GEARINPOS!!!
#plc #siemens #training #motioncontrol #sinamics #s120 #g120

Наука

Опубликовано:

 

5 авг 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 19   
@tarikrachiahi1239
@tarikrachiahi1239 7 месяцев назад
Thanks Jason for these great videos
@jasonwattsae
@jasonwattsae 7 месяцев назад
I appreciate the kind words. I love making them!
@shabbirahmad6524
@shabbirahmad6524 7 месяцев назад
Another very good vodeo. Please keep contineu it
@jasonwattsae
@jasonwattsae 7 месяцев назад
I appreciate it! Thank you for helping the channel by commenting! That is the easiest way to get these videos out to more people!
@vatsalthaker2122
@vatsalthaker2122 7 месяцев назад
Hello sir I have one query I am using a v20 drive to run the conveyor speed setpoint I am giving on an analog input channel via plc 0-10 v ...now I have problem that when I gave 7 rpm which is my upper limit of rpm plc is producing 27648 counts but conveyor is running only on 5 rpm...can you tell me what should I do... thanks and pardon my English
@jasonwattsae
@jasonwattsae 7 месяцев назад
I will look up the V20 parameters and post more, but I would first make sure the voltage at the drive is 10v. What is the gear ratio?
@vatsalthaker2122
@vatsalthaker2122 7 месяцев назад
@@jasonwattsae 570:1 and yes I am giving 10v
@jasonwattsae
@jasonwattsae 7 месяцев назад
I looked up a parameter. Look at r754 and make sure it says 100 when you are trying to run at full speed. If it is saying less (71.4 for 5 rpm) then you can scale this value using p760. This difference seems like the difference between expecting to run the motor at 60hz (1785rpm) but it actually running at 50hz (1350). Make sure p310 and p311 are set correctly if you are trying to run 60hz.
@vatsalthaker2122
@vatsalthaker2122 7 месяцев назад
@@jasonwattsae ok sir thanks I will go to machine and let you know thanks...apart from that at p0760 the default value is already 100 I checked that parameter
@vatsalthaker2122
@vatsalthaker2122 7 месяцев назад
@@jasonwattsae hello sir value shown in r754 is 100...even after changing value of p760 I am not getting any good results I have one question can you tell what I have to enter in p757 ,758 ,p759,p760
@shabbirahmad6524
@shabbirahmad6524 Месяц назад
Dear sir please explain next instruction like mc_cam and all others
@jasonwattsae
@jasonwattsae Месяц назад
I am trying to catch up on edited videos, but check out the livestream below for a little bit more info. ru-vid.com4OgkwM2zseE?si=g9hv174MQKh_SL2r
@michalkall9206
@michalkall9206 4 месяца назад
Hello Jason, can you in next stream make tuning of Technology object for example for Position Axis? I think there is need some calculation as well, or in the end there is need to check trace if tuning its okay :)
@jasonwattsae
@jasonwattsae 4 месяца назад
I think I can definitely talk about it because it really comes down to how well your mechanical system and motor can respond. There are some things in the TO that are important to talk about in order to avoid errors. Thanks for the suggestion!
@michalkall9206
@michalkall9206 4 месяца назад
@@jasonwattsae Thank you very much! :)
@jasonwattsae
@jasonwattsae 4 месяца назад
Thank you for helping this community grow!
Далее
ПОМОГЛА НАЗЫВАЕТСЯ😂
00:20
Просмотров 1,4 млн
Beginner Siemens Drives Training: SINAMICS Drives 101
2:55:59
How to Set Up an Active Line Module
2:34:43
Просмотров 1,1 тыс.
Why The Windows Phone Failed
24:08
Просмотров 242 тыс.
Siemens Motion Control 101: Introduction to Motion
3:42:51
Update on Upcoming Siemens Drives Content!
4:17
Siemens to Allen Bradley Communications
2:37:19
Проверил, как вам?
0:58
Просмотров 364 тыс.