Gd day bossing tanong ko lng po nka dual membrane ano po ang ideal pressure kc itong tubigan ko ay nag po produce ng 2.7 gl ok n po b un ang reading pressure niya ay 135
Hi Sir Isidro, Hingi po sana ako ng advice sa inyo sir. May WRS po ako yung water source ko po is deep well TDS-850ppm. Machine setup is dual membrane - Specs: Feedpump 1.3HP, MMF-10x54, ACF-10x54 and Softener-16x65, Brine tank-130Liters, RO Pump-1.5HP, then the output product(Premeate flow @10LPM). Last Dec 2021 nag pa upgrade ako to triple membrane, then sabi ng technician kaya padaw ng RO pump, at 100Psi ng RO pump yung flow rate ng product is only 11LPM. I saw your youtube vidoes nnu po sir, sa triple membrane an setup yung RO pump is 2HP and at 110Psi mataas po yung flow rate ng product.
Mas mataas na tds mas mataas dapat na osmotic pressure sa r.o membrane...if 1.5hp ka na vertical ay meron sia 105 meters of head times 1.42 to convert it to psi it would be 149psi...if dalawa membrane mo 149psi devided by 2 equals 74.5psi...ang isang membrane need po ng atleast 100psi if gumamit ka ng ultra low pressure na model..kaya bitin po qng 70.5psi bawat isa
@@hezwatertreatmentandsupply8431 thank you po sir. Sa dual membrane at 74.5 psi each ito npo yung optimal pressure ma supply ng VRO? Plus may pressure pa from feedpump na 1.3Hp so more or less ma hit po natin ang 100psi operating presure each membrane, tama po ba sir?
Sir may tanong lang po sana ako. Yung Inlet pressure ko po bumabagsak.. pero after ko magbackwash nagiging normal naman ulit pero ilang minuto lang ganon na naman. Ano po ba sa tingin nyo ang problema?