Тёмный

Slab Design Accordance with Eurocode 2 

ANIS AZMI
Подписаться 991
Просмотров 25 тыс.
50% 1

By Ir Basir Noordin
Faculty of Civil Engineering
UITM Shah Alam, Malaysi

Опубликовано:

 

7 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 23   
@rahmanrahmani2896
@rahmanrahmani2896 4 года назад
Excellent work and thank you !
@ikhsanhjsirat4697
@ikhsanhjsirat4697 3 года назад
Salam Ir. Penerangan yang mantap...
@hanisahapendi4680
@hanisahapendi4680 4 года назад
please add more videos. your video is very helpful
@luisafernandagarzongarzon9745
@luisafernandagarzongarzon9745 4 года назад
good video
@ibrahimibrahim6512
@ibrahimibrahim6512 4 года назад
Pls I need a video about the reliability based code calibration of the eurocode 2 design criteria of reinforced concrete flat slab
@bayankawamleh3447
@bayankawamleh3447 5 лет назад
can you please, explain the method of designing the beam according to Eurocode 2 .
@rahmanrahmani2896
@rahmanrahmani2896 4 года назад
Watch Mike Bather structure design u Tubes videos which cover beam, column and slab. They are excellent. Rahman
@anisazmi5461
@anisazmi5461 4 года назад
Bayan Kawamleh link for beam design according to EC2 ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-iSOKk0g-eHo.html
@davidcivil1651
@davidcivil1651 2 года назад
@@rahmanrahmani2896 you are right Mike's videos are good if you already know and just want to revise the course. Or if you are an experienced engineer. This is good for students I reckon.
@kaungmyat5546
@kaungmyat5546 4 года назад
thanks for recap
@ahmedal4861
@ahmedal4861 10 месяцев назад
Hello sir, every thing clear, thanks , but just provides (how get ?) Tqvm sir
@angelaonwuka1987
@angelaonwuka1987 8 месяцев назад
Sir, What's the reference to the formulars of design shear resistance? Eurocode or BS?
@Itsjikri
@Itsjikri 4 года назад
good video but i think the voice could be louder . thanks
@naimayusuf9563
@naimayusuf9563 8 месяцев назад
why are you usind bs8110 while you are using ec2
@DZspeedbird115.50
@DZspeedbird115.50 8 месяцев назад
SAME QUESTION HERE
@syamthehero
@syamthehero 4 года назад
i Can't get the right answer for the shear resistance value. Could you please explain where you get 94.9 kN?
@anisazmi5461
@anisazmi5461 4 года назад
There is miscalculation for shear resistance value. Actual value is 46.3 kN. Since Vrdc value is less than Vmin value, therefore you need to compare the Vmin value with Ved.
@saleemhasif7782
@saleemhasif7782 2 года назад
Hello sir, I have small doubt in the play time 14:58. can you explain how to get the As, provide value 262 mm^2/m.
@ahmedal4861
@ahmedal4861 10 месяцев назад
Hello,, same my question.
@davidcivil1651
@davidcivil1651 2 года назад
Hi, really appreciate your work. Just wanted to know where we use yeild line method? and which way is more accurate? Thankx in advance.
@jesustabor4669
@jesustabor4669 Год назад
Ygug🎉😊vu
@kaungmyat5546
@kaungmyat5546 4 года назад
one way slab please
Далее
Design of 2 Way Slab (BS 8110)
28:18
Просмотров 8 тыс.
Прохожу маску ЭМОЦИИ🙀 #юмор
00:59
Simply Supported One-Way Slab Design To EC2
22:21
Просмотров 6 тыс.
Difference Between One Way Slab & Two Way Slab
3:19
Просмотров 1,1 млн
Column Design Accordance with Eurocode 2
12:22
Просмотров 25 тыс.
Slab Design to the Eurocode 2 | Step by Step Guide
12:02
Concrete Learning - Introduction to Eurocode 2
17:14
Просмотров 16 тыс.